Loading...
HomeMy WebLinkAboutApplication Files_85048_pg0235 POST DEVELOPMENT- DP1 2007-058 Jones-POST D1 Type l//24-hr 100 year Rainfall=6.90" Prepared by J.R. Russo &Associates Printed 12/27/2010 ' HydroCADO 8.50 s/n 002386 ©2007 HydroCAD Software Solutions LLC Page 35 Subcatchment 12: To Basin#5 Runoff Area=2.330 ac 85.84% Impervious Runoff Depth=6.07" Flow Length=350' Tc=17.1 min CN=93 Runoff=11.09 cfs 1.179 of Subcatchment 13: To Lower Basin#5 Runoff Area=0.930 ac 80.65% Impervious Runoff Depth=5.96 Flow Length=398' Tc=10.9 min CN=92 Runoff=5.15 cfs 0.462 of Subcatchment 14: To Treatment Unit#2 Runoff Area=1.520 ac 91.45% Impervious Runoff Depth=6.42" ' Tc=5.0 min CN=96 Runoff=10.56 cfs 0.814 of Subcatchment 15: Entry Drive Runoff Area=0.400 ac 92.50% Impervious Runoff Depth=6.31" Tc=5.0 min CN=95 Runoff=2.76 cfs 0.210 of Subcatchment 16: Direct to Basin#5 Runoff Area=6.240 ac 5.77% Impervious Runoff Depth=3.23" Flow Length=430' Slope=0.0100'/' Tc=39.3 min CN=67 Runoff=11.64 cfs 1.678 of ' Subcatchment 17: Direct to Basin#6 Runoff Area=3.520 ac 24.43% Impervious Runoff Depth=4.17" Tc=5.0 min CN=76 Runoff=17.81 cfs 1.223 of Reach 3R: Basin to MH Avg. Depth=0.59' Max Vet=4.07 fps Inflow=2.61 cfs 2.693 of D=18.0" n=0.012 L=1,250.0' S=0.0050'/' Capacity=8.05 cfs Outflow=2.61 cfs 2.693 of Pond B1: Basin#1 Peak Elev=86.58' Storage=77,050 cf Inflow=24.05 cfs 2.504 of 12.0"x 76.0' Culvert Outflow=2.76 cfs 2.467 of Pond B2: Basin#2 Peak Elev=86.65' Storage=59,324 cf Inflow=23.13 cfs 5.839 of Primary=8.00 cfs 5.706 of Secondary=1.78 cfs 0.109 of Outflow=9.61 cfs 5.815 of Pond B3: Basin#3 Peak EIev=86.30' Inflow=8.05 cfs 5.765 of Primary=8.05 cfs 5.748 of Secondary=2.40 cfs 0.017 of Outflow=8.05 cfs 5.765 of Pond 64: Basin#4 Peak EIev=84.93' Storage=46,931 cf Inflow=25.47 cfs 9.429 of Primary=20.91 cfs 9.412 of Secondary=0.00 cfs 0.000 of Outflow=20.91 cfs 9.412 of Pond B& Basin#5 Peak EIev=84.35' Storage=95,762 cf Inflow=40.01 cfs 5.328 of 24.0"x 26.0' Culvert Outflow=10.34 cfs 5.311 of Pond B6: Basin#6 Peak EIev=84.07' Storage=332,111 cf Inflow=69.54 cfs 19.492 of 15.0"x 94.0' Culvert Outflow=12.05 cfs 19.410 of Pond CB35: CB#35 Peak EIev=84.10' Inflow=10.77 cfs 5.521 of 24.0"x 46.0' Culvert Outflow=10.77 cfs 5.521 of Pond CB36: CB#36 Peak EIev=84.14' Inflow=10.77 cfs 5.521 of 24.0"x 26.0' Culvert Outflow=10.77 cfs 5.521 of Pond CB7: CB#7 Peak EIev=85.95' Inflow=8.66 cfs 6.376 of Primary=8.66 cfs 6.367 of Secondary=1.53 cfs 0.009 of Outflow=8.66 cfs 6.376 of Pond C1138: CB#8 Peak EIev=85.63' Inflow=9.49 cfs 6.606 of Primary=9.49 cfs 6.606 of Secondary=0.00 cfs 0.000 of Outflow=9.49 cfs 6.606 of