HomeMy WebLinkAboutApplication Files_85048_pg0110 Lanes, Volumes, Timings Fed-Ex Distribution Center, South Windsor ' 7: Route 194 & Rye Street 2013 Combined AM Peak Lane Group EBL EBT WBT WBR SBL SBR Turn Bay Length (ft) 200 Base Capacity(vph) 409 2220 873 670 Starvation Cap Reductn 0 0 0 0 Spillback Cap Reductn 0 0 0 0 Storage Cap Reductn 0 0 0 0 Reduced v/c Ratio 0.22 0.26 0.75 0.51 ' Intersection Summary Area Type: Other Cycle Length: 60 ' Actuated Cycle Length: 50.3 Natural Cycle: 50 Control Type: Actuated-Uncoordinated ' Maximum v/c Ratio: 0.82 Intersection Signal Delay: 13.1 Intersection LOS: B Intersection Capacity Utilization 65.9% ICU Level of Service C Analysis Period (min) 15 # 95th percentile volume exceeds capacity, queue may be longer. Queue shown is maximum after two cycles. Splits and Phases: 7: Route 194 & Rye Street 1� 2 ' 12/31/2010 Synchro 6 Report Bubaris Traffic Associates Page 2