HomeMy WebLinkAboutApplication Files_85048_pg0110 Lanes, Volumes, Timings Fed-Ex Distribution Center, South Windsor
' 7: Route 194 & Rye Street 2013 Combined AM Peak
Lane Group EBL EBT WBT WBR SBL SBR
Turn Bay Length (ft) 200
Base Capacity(vph) 409 2220 873 670
Starvation Cap Reductn 0 0 0 0
Spillback Cap Reductn 0 0 0 0
Storage Cap Reductn 0 0 0 0
Reduced v/c Ratio 0.22 0.26 0.75 0.51
' Intersection Summary
Area Type: Other
Cycle Length: 60
' Actuated Cycle Length: 50.3
Natural Cycle: 50
Control Type: Actuated-Uncoordinated
' Maximum v/c Ratio: 0.82
Intersection Signal Delay: 13.1 Intersection LOS: B
Intersection Capacity Utilization 65.9% ICU Level of Service C
Analysis Period (min) 15
# 95th percentile volume exceeds capacity, queue may be longer.
Queue shown is maximum after two cycles.
Splits and Phases: 7: Route 194 & Rye Street
1� 2
' 12/31/2010 Synchro 6 Report
Bubaris Traffic Associates Page 2