HomeMy WebLinkAboutApplication Files_82693_pg0890 #1B Vanasse Hangen Brustlin,Inc. Transportation, Land Development,and Project# 72189-CT Studios ' Environmental Services Location South Windsor, CT 54 Tuttle Place Design Storm(Years) 25 Middletown,CT Date 3/9/2010 ' Revised Designpd By GAA Checked By Checked By F'D: MINIMUM MEDIAN STONE DIAMETER(1350)AT EACH FLARED END STRUCTURE(FES) MINIMUM DIMENSIONS OF FES APRON 4EN: 1. EQ. FOR LENGTH OF FES APRON: (source:RI Stormwater Design Manual) ' 1.7 Q Q= pipe discharge (CFS) La = 3/2 + 8Do ; where Do Do= maximum inside culvert width (ft) 2. EQ. FOR WIDTH OF FES APRON*: (source:RI Stormwater Design Manual) W= 3 Do+ La where La= minimum width of FES apron (ft) *Note: Assumes tailwater depth Do= as described above is less than 1/2 of Do 3. EQ. FOR MEDIAN STONE DIAMETER: ' (source:RI Stormwater Design Manual) 0.02 { Q 4/3 TW= tailwater depth above d50 TW \ DO where invert of the culvert (ft) Q DO= as described above 4. Tailwater Depth =0.2-0.4 feet. (Assumed value used to reduce the effects of tailwater on velocity dissipation to neglible levels) 5. Values of Q at each FES. (Source:HydroCAD hydrologic model by VHB)