HomeMy WebLinkAboutApplication Files_82693_pg0558 Conduit FlexTable: Combined Pipe/Node Report (72189 Pipes.stc) Label Start.: Stop.. Upstream.. Upstream Upstream Totai Capacity Velocity invert. °::Invert Length. Cover Cover; Slope : :Section Size Manning' Material Hydraulic : Hydraulic ensi Inlet -:-Inlet C Int et-Area-- Flow- --Full.Flow AVEra a .: U stream- Qownstre - ft -(Start)-. : Sto Node. - : Node tY _.... (....... ... ..) ..( .......g..). ..(.p.....,. . .(....... (. ).. . .. (...p} (ftlft) = _ :s n -:- -- ---Grade Line- -Grade-Line- ----- - ----- -- - - -- -- - - -- �n/h -acres it3/s #t3(s 4/s. .:.. .. - ::. am .: : . ft ..:::: €k In - Out ::.... Corrugate P-405 DMH-8 TEE-401 (N/A) 7.533 (N/A) 2051 30.71 6.70 55.10 54.78 67.0 2.10 2.71 0.005 30inch 0.012 ( HDPE Smooth57.03 56.96 ( Interior) Corrugate P-406 CB-25 DMH-8 0.830 7.800 0.860 5.61 6.14 4.57 55.30 55.10 26.0 2.75 3.35 0.608 15 inch 0.012 d HDPE 57.19 57.03 (Smooth Interior) Corrugate P-408 CB-22 DMH-8 0.900 7.800 0.240 1.70 2.65 3.58 56.60 55.70 191.0 3.00 3.00 0.005 12 inch 0.012 d HDPE 57.35 57.03 (Smooth Interior) Corrugate P-410 T-403 DMH-8 (N/A) 7.757 (N/A) 13.45 10.72 7.61 55.68 55.10 65.0 2.52 3.10 0.009 18 inch 0.012 d HDPE 57.93 57.03 (Smooth Interior) Corrugate P-411 CB-24 T-403 (N/A) 7.800 (N/A) 0.00 13.48 0.00 56.00 55.68 23.0 2.20 2.52 0.014 18 inch 0.012 d HDPE 57.93 57.93 (Smooth Interior) Corrugate P-412 CB-23 T-403 (N/A) 7,800 (N/A) 13.45 11.05 7.61 56.30 55,68 66.0 1.90 2.52 0.009 18 inch 0.012 d HDPE 58.86 57.93 (Smooth Interior) 1 Bentley StormCAD V8i(SELECTseries 2) 72189 Pipes.stc Bentley Systems,Inc. Haestad Methods Solution Center [08.11.02.35) 7/25/2011 27 Siemon Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 4 of 4