HomeMy WebLinkAboutApplication Files_72680_pg0003 v
d. Existing and proposed water and-all existing utilities.
e. Present wooded area indicated by foliage lines. Any trees to be saved
should be shown.-
f Existing and proposed contours shall be shown in not less -than two foot
intervals, but in cases of relatively level land,the contours shall be one-
foot intervals and spot elevations:
g Regulated wetlands and 100-year floodplain or note that none are
present. -- ju ti+e R rct�t 3
h. Proposed storm drainage system, showing all catch basins, endwalls
manholes, lengths and sizes of pipes and elevations of structures.
(Maximum distance between catch basins shall be 300 feet and minimum
size of storm drain lines shall be 15 inches,within Town ROW.) If
plan/profile sheet is provided all of this does not need to be shown. Only
top of frame elevations and inverts of open discharge pipe shall be shown
on this plan.
L Connections of all springs
pangs Into proposed storm drainage system as
needed.
j. Location and indications of existingbrook channels,nets, and 100 year flood
limits.
_._ k. A-2&T-2 Certification; P.E&L.S. Seals.
. 6. ' Landscaping.plan -
-; 7. Drainage calculations: -Zero Runoff Increase per attached'guidelines.
. ^ See pr�E_urov� c'i,��'ti ct�ra.J
_AZA 8. Traffic Report
9. Site Lighting Plan
- 10. Plans and Profiles: A plan and profile of the proposed streets drawn on
lan r-ofil p /p apaper-of-sca-1es-l-inch to=40Feet horizontally,--and-lAnc-h-to-4feet--
vertically on sheets not exceeding 24'inches`by 36 inches,-'including ruled
margins-and containing the fotlo-wing:
LaX out of streets in sections coo
bystations_with_the_pr�fite._
-- - - - - -- - - - - — -- -
_ b. Street plan showing roadwa drainage sanita sewer includin house
sewer), foundation drains, lot lines, buildings including all utilities with
- - - -
andinverrts size,
��
3