HomeMy WebLinkAbout2 Collins Lane - UST - Fire Marshal Tankworks June 6, 2018 Dorothy Collins 2 Collins Lane South Windsor, CT 06074 Re: Removal and Disposal of(1) 1000 Gallon Underground Heating Oil Tank & Installation of(1)275 Gallon.Basement Heating Oil Tank At: 2 Collins Lane South Windsor, CT 06074 I Dear Mrs. Collins, Thank you for the opportunity to service the removal of the buried oil tank and installation of the new tank at the above referenced address. The tank was located on the left side of the house. The soil in the grave showed no signs of contamination and was backfilied. Before backfilling one final confirmation soil sample was collected and tested at an independent lab for CTETPH(extractable petroleum hydrocarbons). The results of the soil sample we obtained indicated that any trace of oil was Not Detected(ND). This letter, along with the attached soil sample results, should be stored safely with all legal documents pertaining to this property. Please feel free to call us if you have any further questions. It has been a pleasure working with you. We hope that you are pleased with our services and that you will recommend us to others. Very t yours, Rosent&y Viola Rainville Owner CC: Town of South Windsor Attn: Fire Marshal 1540 Sullivan Ave, South Windsor, CT 06074 PHOEVIX�k*,;. al. Environmental Laboratories, Inc. Tuesday, May 15, 2018 Attn: Mrs. Rose Rainville Tankworks 360 East Center Street Manchester, CT-06040 Project ID: 2 COLLINS LANE SOUTH WINDSOR Sample ID#s: CA46533 This laboratory is in compliance with the NELAC requirements of procedures used except where indicated. This report contains results for the parameters tested, under the sampling conditions described on the Chain Of Custody,as received by the laboratory. This report is incomplete unless all pages indicated in the pagination at the bottom of the page are included. All soils, solids and sludges are reported on a dry weight basis unless otherwise noted in the sample comments. A scanned version of the COC form accompanies the analytical report and is an exact duplicate of the original. If you have any questions concerning this testing, please do not hesitate to contact Phoenix Client Services at ext. 200. Sincerely yours, Phyllis hiller Laboratory Director NJ Lab Registration #CT-003 NELAC -#NY11301 NY Lab Registration #11301 CT Lab Registration #PH-0618 PA Lab Registration#68-03530 MA Lab Registration #M-CT007 RI Lab Registration#63 ME Lab Registration#CT-007 UT Lab Registration#CT00007 NH Lab Registration #213693-A,B VT Lab Registration#VT11301 587 East Middle Turnpike,P.O.Box 370,Manchester,CT 06040 Telephone(860)645-1102 Fax(860)645-0823 Page 1 of 6 Environmental Laboratories, Inc. 587 East Middle Turnpike,P.O.Box 370,Manchester,CT 06045 Tel(860)645-1102 Fax(860)645-0823 Analysis Report FOR: Attn: Mrs. Rose Rainville Tankworks May 15,2018 360 East Center Street Manchester, CT 06040 Sample Information Custody Information Date Time Matrix: SOIL Collected by: 05/09/18 9:30 Location Code:` TANKWORKS Received by: LB 05/14/18 16:19 Rush Request: 24 Hour Analyzed by: see"By"below P.O.#: Laboratory Data SDG ID: GCA46533 . Phoenix ID: CA46533 Project ID: 2 COLLINS LANE SOUTH WINDSOR Client ID: BTM RL/ Parameter Result PQL Units Dilution Date/Time By Reference Percent Solid 96 % 05/14/18 AP SW846-%Solid Extraction of CT ETPH Completed 05/14/18 JBNCK SW3545A TPH by GC (Extractable Products) Ext.Petroleum H.C.(C9-C36) ND 51 mg/Kg 1 05/15/18 JRB CTETPH 8015D Identification ND mg/Kg 1 05/15/18 JRB CTETPH 8015D QA/QC Surrogates %n-Pentacosane 79 % 1 05/15/18 JRB 50-150% RUPQL=Reporting/Practical Quantitation Level ND=Not Detected BRL=Below Reporting Level QA/QC Surrogates:Surrogates are compounds(preceeded with a%)added by the lab to determine analysis efficiency. Surrogate results(%)listed in the report are not"detected"compounds. Comments: All soils,solids and sludges are reported on a dry weight basis unless otherwise noted in the sample comments. If there are any questions regarding this data,please call Phoenix Client Services. This report must not be reproduced except in full as defined by attached chain of custody. AOL Phyllis hiller,Laboratory Director May 15,2018 Reviewed and Released by:Bobbi Aloisa,Vice President Ver 1 Page 2 of 6 PHOEIVX Environmental Laboratories,Inc. 587 East Middle Turnpike,P.O.Box 370, Manchester,CT 06045 QA/QC Report Tel.(860)645-1102 Fax(860)645-0823 May 15, 2018 QA/QC Data SDG I.D.: GCA46533 Rio pro Blk LCS LCSD LCS MS MSD MS Rec RPD Parameter Blank RL % % RPD % % RPD Limits Limits QA/QC Batch 430332(mg/Kg),QC Sample No:CA46770(CA46533) TPH by GQ (Extractable Products) -Soil Ext.Petroleum H.C.(C9-C36) ND 50 92 98 6.3 102 73 33.1 60-120 30 %n-Pentacosane 93 % 95 102 7.1 102 75 30.5 50-150 30 Comment: Additional surrogate criteria:LCS acceptance range is 60-120%MS acceptance range 50-150%.The ETPH/DRO LCS has been normalized based on the alkane calibration. r=This parameter is outside laboratory RPD specified recovery limits. If there are any questions regarding this data,please call Phoenix Client Services at extension 200. RPD-Relative Percent Difference LCS Laboratory Control Sample LCSD-Laboratory Control Sample Duplicate AOL MS-Matrix Spike MS Dup-Matrix Spike Duplicate Phyllis hiller, Laboratory Director NC-No Criteria May 1 ,2018 Intf-Interference Page 3 of 6 Coder: Yes No Coolant: IPK EFHCE No CHAIN OF CUSTODY RECORD TemP3.0 C Pg of PH01 VIX Data Delivery/Contact Options: L/1 587 East Middle Turnpike,P.O.Box 370,Manchester,CT 06040 E:]Fax: Environmental Laboratories, Inc. Email:info@phoenixlabs.com Fax(860)645-0823 Phone: Client Services (860) 645-8726 ❑Email: Customer: ::::nAXM 1A S M Project: 9({t e- Project P.O: Address: Report to: 4t tJ.JA4&'f This section MUST be Invoice to: completed with v,40-W 0-eu Bottle Quantities. Client Sample-Info Identlfleation Sampler's Analysis a F� Signature 5 o 0 Date: Request �ry � Matrix Code: cti oti �ZG DW=Drinking Water GW=Ground Water SW=Surface Water WW=Waste Water Qp° 0�a RW-Raw Water SE-Sediment SL=Sludge S=Soil SD--Solid W=Wipe 01L=Oil F �� S=Bulk L=LiQ uid ° P,:a\`�.p�0�>ryyo`,ry ry�ti`ryhp�•,���,o�°a° PHOENIX USE ONLY Customer Sample Sample Date Time �� SAMPLE* Identification Matrix S d Sampled GAP �o� c, G bpF 4cn 533T RolI Ac by: Date: Time: Rl CT MA Data Format O ❑Direct Exposure ❑RCP Cart ❑MCP Certification ❑Excel (Residential) ❑GW Protection ❑GW-1 ❑ PDF C' ❑Gw ❑SW Protection ❑GW-2 ❑GIS/Key Comm ,Special Requirements or Regula ns: '� , ❑Other ❑GA Mobility ❑ GW-3 EQuIS Turnaround: er ❑GB Mobility ❑ S"1 Data Package 1 Day* El Residential DEC El S'2 ❑Tier II Checklist ❑ 2 Days' ❑I/C DEC ❑ S-3 ❑Full Data Package" ❑ 3 Days. ❑Other ❑MWRA eSMART ❑ Phoenix Std Report ❑Standard ❑ Other { ❑ Other ❑ Other State where samples were collected: !_ SURCHARGE APPLIES 'SURCHARGE APPLIES C ,N AC C090'4 YOENIX Ot .h Environmental Laboratories, Inc. _ 587 East Middle Turnpike,P.O.Box 370,Manchester,CT 06045 NY#11301 Tel.(860)645-1102 Fax(860)645-0823 Analysis Comments May 15, 2018 SDG I.D.: GCA46533 The following analysis comments are made regarding exceptions to criteria not already noted in the Analysis Report or QA/QC Report: None. Page 5 of 6