50 Andrews Way - Life Safety System Test (3)
CONTRACTOR'S MATERIAL TEST CERTIFICATE FOR ABOVEGROUND PIPING PROCEDURE Upon completion of work,inspection and tests shall be made by the contracor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners and contractor. It is understood the owner's representative's signature in no way prejudices and claim against contractor for faulty material,poor workmanship or failure to comply with aproving authority's requirements or local ordinances. PROPERTY NAME DATE Continental Residence at Evergreen 8/21/2017 PROPERTY ADDRESS 50 Andrews Way South Windsor CT 06074 ACCEPTED BY APPROVING AUTHORITY('S)NAMES Walter Summers ADDRESS PLANS 232 West Rd South Windsor 06074 INSTALLATION CONFORMS TO ACCEPTED PLANS X❑ YES NO EQUIPMENT USED IS APPROVED X❑ YES NO IF NO,EXPLAIN DEVIATIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION 0 YES NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT IF NO,EXPLAIN INSTRUCTIONS HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS YES X NO AND NFPA 25 BEEN LEFT ON PREMISES The builder has been notified that Hart Mechanical,Inc does not perform the required NFPA 25 quarterly inspections and that they need to hire their own inspection company. LOCATION OF SYSTEM SUPPLIES BLDGS. Building 6-Wet System MAKE/MODEL HEAD TYPE YEAR ORIFICE SIZE QUANITIY TEMPERATURE RATING Tyco-LFII Res Concealed Pend 2016 1/2" 186 160o Tyco-TYFRB Standard Pendent 2016 1/2" 25 200o SPRINKLERS Tyco-LFII Residential Sidewall 2016 1/2" 80 155, Tyco-DS-1 Dry Sidewall 2016 V. 24 155, PIPE AND PIPE CONFORMS TO NFPA13 STANDARD AYES ❑ NO FITTINGS FITTINGS CONFORM TO AWWA STANDARD AYES NO IF NO,EXPLAIN ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST PIPE ALARM VALVE TYPE MAKE MODEL MIN. SEC. OR FLOW Pressure Switch System Sensor ESP-40 5 INDICATOR Low Air Switch System Sensor EPS-45-2V DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. Victaulic 768-NXT N/A TRIP POINT TIME WATER WATER AIR AIR REACHED TEST ALARM OPERATED DRY PIPE TIME TO TRIP* PRESSURE PRESSURE PRESSURE OUTLET* PROPERLY OPERATING TEST Iou MIN. SEC. PSI PSI PSI MIN. SEC. YES NO Q.O.D. With Q.O.D IF NO,EXPLAIN *MEASURED FROM THE TIME INSPECTOR'S TEST CONNECTION VALVE IS OPENED. HAProjects\2015\Continental Residence @ Evergreen\Fire Protection\Closeout OocumentMbove Gound Certificate 1.xis (OVER) CONTRACTOR'S MATERIAL TEST CERTIFICATE FOR ABOVEGROUND PIPING OPERATION PNEUMATIC Lj ELECTRIC HYDRUALIC rFMQ SUPERVISED YES NO DETECTING MEDIA SUPERVISED S NO DELUGE& DOES VALVE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIO YES NO PREACTION IS THERE AN ACCESSIBLE FA EACH CIRCUIT FOR TESTING PLAIN VALVES YES —150—ES EACH CIR DOES EACH CIRCUIT OPERATE SUPERVISION VALVE MAXIMUM TIME TO OPERATE M MODEL LOSS ALARM RELEASE___ ELEASE RELEASE YES NO YES NO SEC. HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi(13.6 bars)for two hours or 50 psi(3.4 bars)above static pressure in excess of 150 psi(10.2 bars)for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. TEST All aboveground piping leakage shall be stopped. DESCRIPTION FLUSHING: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outles such as hydrants and blow-offs. Flush at flows not less tan 400 GPM(1514 Umin)for 4-inch pipe,600 GPM(2271 Umin)for 5-inch pipe 750 GPM(2839 Umin)for 6-inch pipe,1000 GPM(3785 Umin)for 8-inch pipe,1500 GPM(5678 Umin)for 10-inch pipe and 2000 GPM(7570Umin)for 12-inch pipe. When supply cannot produce stipulated flow rates,obtain maximum available. PNEUMATIC: Establish 40 psi(2.7 bars)air pressure and measure drop which shall not exceed 1-1/2 psi(0.1 bars)in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi(0.1 bars)in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HRS. IF NO,STATE REASON HYDROSTATICALLY TESTED: :: 1/26/201-7 DRY PIPING PNEUMATICALLY TESTED AYES ❑ NO EQUIPMENT OPERATES PROPERLY [g]YES ❑ NO TESTS DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST PIPE: RESIDUAL PRESSURE WITH VALVE IN TEST TEST STATIC PRESSURE , PSI - . PIPE OPEN WIDE G ;PSI Underground mains and lead in connections to system risers flushed before connection made to sprinkler piping. VERIFIED BY COPY OF THE U FROM NO.85B AYES ❑ NO OTHER EXPLAIN FLUSHED BY INSTALLED OF UNDER- BY Others GROUND SPRINKLER PIPING ❑ YES ❑ NO BLANK TESTING NUMBER USED LOCATIONS N/A NUMBER REMOVED GASKETS WELDED PIPING X7 YES NO IF YES... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCUDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR-3 X❑ YES ❑ NO SO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELERS QUALIFIED IN WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,AR-3 © YES ❑ NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN PIPING ARE SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED,AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED X YES NO HYDRAULIC DATA NAMEPLATE PROVIDED IF NO,EXPLAIN NAMEPLATE X YES NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: REMARKS Date Tested Date Left Open: , NAME OF SPRINKLER CONT art Mech ical,Inc. TESTS WITNESSED BY SIGNATURES FOR PROPERTY WN TITLE DATE ZZ 1.7 FO S R KL C NTRA T TITLE �� DATE _/ r ADDITIONAL EXPL\NAligAND FOTES 85A(10-80) H:\Projects\2015\Continental Residence @ Evergreen\Fire Protection\Closeout Documents\Above Gound Certificate 1.As (OVER)