HomeMy WebLinkAbout233 Sullivan Avenue - Life Safety System DO NOT MOVE BY ORDER OF THE STATE FIRE MARSHAL Pre-Engineered System InspectionReport ALLSTATE UIPMENT , New Engla a er inROLProtection Date of Service: � " ` Time: � a M 15 Robert Jackson way office(866)MN900 Annual/Semi-Annual/Recharge-/New System/ enovatio (circle one) Plainville,CT 06062 Fax(860)793-6906 www.allstatefireinc.com . VALID FOR 6 MONTHS FROM DATE:OF SERVICE Customer/Location System Information Name: Make: Address: .3 ��1fi4��`® Model City, ST,Zip: -5Q— �,✓i�� .t`� " Size: C3 Phone: Control Head: X Owner/Manager: L"`Ys fi Location of system: ! �'r C. Yee No N/A Yes No NIA 1 Hazard unchanged since last inspection ( ❑ ❑ 13 Manual release proper and operable. l� ❑ ❑ 2 System interlocked with building fire alarm. ❑ ❑ 14 Microswitches installed QTY--L-Tied-in QTY 3 All hazards properly covered w/correct nozzles. -3E ❑ ❑ 15.Gas valve connected to system(,t�E ./ELEC..) Q/❑ ❑ . 4 Hood/duct penetrations properly sealed. L ❑ 16 Piping/conduit securely brackete . ❑ ❑ 5 Grease accumulation: excessive heavy � normal 17 Piping obstruction test performed ( ❑ ❑ 6 Pressure gauge within acceptable range. 18 Proper nozzle caps/covers in place. QTY. Z _❑ ❑ 7 Cartridge weight within acceptable range. WT. O❑ ❑ 19 Exhaust fan in operating condition. I ❑ ❑ 8 Cylinder hydrotest due ;W F 6-year maint.due 20 System operational&armed. ;` ❑ ❑ 9 Cylinder properly mounted. Lid L❑ ❑ 21 Fan warning sign on hood. ❑ C;v ❑ 10 Detection line and o operable. proper p Mr ❑ ❑ 22 K-Glass fire extinguisher in cooking area. �v ❑ ❑ 11 QTY Fusible Links/Thermal Detector Installed 23 Personnel instructed on manual operation of system. �r ❑ ❑ f 2120 2800 —&�--3600 4500 500° _other( °) 24 Filters compliant with NFPA96 fa� ❑ ❑ k 12 Replaced fusible links-Mfg Date . C}� ❑ ❑ ❑ 25 System meets U.L.300/1254 standards. ❑ ❑ Hazard Protected: 0 U1 Safety.Notice:Non-compliant systems may fail to extinguish/supress a fire.Below are non compliant conditions which require immediate attention.All State Fire Equipment assumes no responsibility for system performance if these conditions are not corrected and/or verified by an authorized agent of All State Fire Equipment. ❑See Attached Proposal to Correct Deficiencies Comments/Non-Compliance: �� '� !fz f` t All State Fire Equipment Agent: �f� Date: ; f 7 . Customer's Authorized Agent: t Date: CT LIC.#F300.42 MA-CR. 1097 °�" F�� Customer Acknowledgement and,UL-300 Safety Alert on reverse —Rev.111913 This report may be forwarded to the local authority having jurisdiction. NAFm NFPA® MEMBER k.. ALL STATE FIRE EQUIPMENT 15 Robert Jackson Way, Plainville, CT 06062 Ph:(860)793-6900—Fax: (860)793-6906 CT LIC F30042 MA CR 1097 CUSTOMER ACKNOWLEDGEMENT The customer acknowledges that any inspection of a customer's fire equipment by All State Fire Equipment (ASFE) is limited to identification of deficiencies that may impede or hamper the intended function of the equipment and that ASFE is not responsible for, nor capable of, p p identifying by inspection, every defect that may adversely affect the system's performance, particularly those defects of a latent nature, defects or omissions related to the manufacturer's design and instructions or defects which exist in inaccessible areas of the system, whether or not such defect's existence could have been determined by inspection had the area been accessible at the time of inspection. The customer further acknowledges that it is beyond ASFE's ability to determine with any degree of certainty whether any fire equipment is capable of extinguishing any fire as intended by the manufacturer of the equipment, even if such equipment is in perfect working order and properly installed in accordance with the manufacturer's listed installation and design manual. The customer further acknowledges that ASFE is not an insurer and that the customer assumes all risk of property damage and for loss of life to the customer's employees, patrons, guests, vendors, and/or any other individuals on the customer's premises where the fire protection equi ''lent is installed and that ASFE neither bears nor assumes any responsibility whatsoever for ano loss or damage resulting from any causes beyond ASFE's reasonable control, including, without limitation, if the fire suppression equipment: fails to function as intended or expected, is outdated, has been tampered with, altered or has been improperly used, repaired or maintained, or if the hazard protected by the fire suppression equipment has been altered or changed. Regardless of all else, ASFE's liability on any claim for loss arising out of or connected with the fire suppression equipment listed on`?fi;L�---face hereof shall be limited to two times the cost of the inspection and in no cases shall ASFE be liable for special., incidental or consequential damages. UL.7300 SAFETY ALERT (Wet Chem Only) UL-300 is a design-testing standard for manufacturers of fire suppression systems for commercial cooking hazards, which took effect in November of 1994. The previous testing standard was promulgated at a time when the use of animal based cooking fats and oils dominated the commercial cooking industry and at a time when cooking appliances were designed with less thermal efficiency. As a result, the progression to vegetable based cooking oils created hotter burning fires in appliances that held their heat much longer and in effect, systems designed prior to the UL-300 standard are inadequate to protect a modern commercial cooking hazard. As a result of these changes, if your fire suppression system was designed prior to the latest design testing standard for kitchen fire suppression systems, Underwriter's Laboratories Standard UL-300, in effect since November of 1994, it is unlikely that your system is capable of providing adequate protection from fire, even though that equipment, when initially installed, may have complied with the then applicable code and design standards. ASFE strongly urges owners of pre-UL-300 systems`lo upgrade their systems to the newest standard as soon as possible and in no case shall ASFE have any liability of any kind relating to the performance, or lack thereof, of a pre-UL-300 syst&n.