HomeMy WebLinkAbout151 Sand Hill Road - SFMO Modification - STATE OF CONNECTICUT Department of Administrative Serv' es ANNED Division of Construction Services �'xxxny x"s� - Office of State Fire Marshal MODIFICATION REQUEST # FM-0423-14 PROJECT NAME: SOUTH WINDSOR(SBA/SPRINT SITE CT33XC555) ADDRESS: 151 SAND HILL ROAD TOWN: SOUTH WINDSOR STATE FIRE MARSHAL In accordance with Section 29-338 of the Connecticut General Statutes,the decision of the Office of the State Fire Marshal in this matter is: This modification request that seeks relief from the Connecticut Hazardous Chemicals Code effective January 24, 1997 specifically NFPA 50A/1994 Section 4-1.2 which requires electrical equipment within 15 feet of hydrogen cylinders located outdoors be in accordance with Article 501 of NFPA 70 for Class I, Division 2 Locations. With consideration of the conditions that exist with respect to the location of the Reli-On HSM16 fuel cabinet containing 16-510 SCF hydrogen cylinders, totaling 8160 SCF, is installed within the Class I, Division 2 location of the electrical equipment, the proposal to install and 2 hour rated constructed CMU wall between the HSM16 Fuel Cabinet and the electrical equipment, this request is being APPROVED without the installation of the CMU wall. It is of our opinion that the properties of hydrogen allow for rapid dispersion and would not be a hazard in this type of installation. Evaluated by JPD Reviewed by: , Joseph. Kingston Decision endorsed by: 4t/ �� William Abbott State Fire Marshal Date: "In accordance with Connecticut General Statute 29-340, any person aggrieved by any such regulation or act of said commissioner in enforcing the same may apply for relief to the superior court for the judicial district of Hartford or for the judicial district in which such plant or equipment is located or, if said court is not in session, to any judge thereof,who may grant appropriate relief.." a _ DPS-0927-C Rev,1/2001 State of Connecticut,Department of Public Safety Division of Fire,Emergency&Building Services Office of State Fire Marshal i APPLICATION FOR REQUEST FOR MODIFICATION OF A REQUIREMENT OF A FIRE SAFETY REGULATION ADOPTED PURSUANT TO CHAPTER 541 OF THE CONNECTICUT GENERAL-STATUTES Reference No. Facility Name:.South Windsor(SBA/Sprint Site CT33XC555) Facility address: 151 Sand Hill Road, South Windsor, CT 06074 Number Street city Stale zip Facility owner: SBA Towers II, LLC Telephone: 561-226-9523 Owner's Address: 5900 Broken Sound Parkway NW, Boca Raton, FL 33487 Number Street city State ZIP Applicant's Name: Hudson Design Group Telephone: 978-557-5553 Applicants address: 1600 Osgood Landing, Bldg 20N, Suite 3090, North Andover, MA 01845 i Number Street city State Zip Contact Person- Derek Creaser, PE Telephone: 617-306-3034 z UtilityTelecommunications Tower with Hydrogen Stora a for backup Type of Facility: " g p generator j Office Building,LP-Gas Bulk Plant„Automotive Service Station,etc, This Facility is:❑ New;W Existing; ❑ Renovation; Date of Construction: 2012 :Date of Present Use:current Previous modifications for this Facility: s❑ Unknown; ❑ No; ❑ Yes, Modification Numbers: ❑ Check if a Modification Request to the State Building Code is being submitted to the Office of State Building Inspector. I,the above named applicant, being a lawful agent of the owner,request modification/relief from a requirement of the CT: C> ❑ Moving Picture Theater Code pursuant to C.G.S.§29-109 ❑ Gas Equipment&Piping Code pursuant.to ❑ Amusements/Tentavd Portable Shelter Codes pursuant to C.G.S.§29-329(c) C.G.S.§29-140 ❑ Liquefied Petroleum Gas&Liquefied Natural Gas Code r ❑ State Fire Safety Code pursuant to C.G.S.§29-296 pursuant to C.G.S.§29-333 ❑ Oil Burning Equipment Code pursuant to C.G.S.§29-317(c) azardous Chemical Code pursuant to C.G.S.§29-338 J j Oi reworks and Special Effects Code pursuant to \ i ❑ Flammable&Combustible Liquids Code pursuant to C.G.S.§29-357(c) i I � C.G.S.§29-321 i i \ ❑ Model Rocketry Code pursuant to C.G.S.§29-368 For the requirement as prescribed in: Regulation Number: 29-337 Standard: NFPA 50A Section Number: 3-2&4-1.2 i 29-292-8d,26-317-lb (IfAppllcable) NFPA 30,NFPA 54.etc Identify Section Number i I request this modification/relief due to the following reasons: JJIi ❑e Equivalent Alternative ❑ Practical Difficulty ❑v Requirements Unwarranted Describe area of non-conformance with the appropriate regulation,Its location In the facility,and a brief descrlptlon why code compliance cannot be achieved,specify dimensions as applicable- An existing Reli-On 8000 SCF Hydrogen storage module (HSM) at 3000 psi does I not meet the setback requirements per NFPA 50A-94 Section 3-2.2#11: 50' setback to inlets to HVAC; and Section 4-1.2: 15' setback to unclassified electrical equipment. Reli-On cites NFPA 497 for further information on classified electrical equipment , locations; and seems to claim that the area directly adjacent to the HSM is not a classified location: "Experience has shown that the release of ignitable mixtures from some operations and apparatus is so infrequent that the area classification is not necessary." IM ❑ Separate Sheet Attached t 0 o I i 1 1 I intend to provide the following safeguard(s)as an alternative measure to secure public safety in lieu of strict compliance with the requirement of the 29-337 Section NFPA 5OA-94 Sections 3-2&4-1.2 noted above: - Insert Name of Regulation for which ModilicatioNRelief is being Requested Idengfy seotlon of CodelRegulallon Propose to install a 2 hour fire barrier in lieu of the 15' unclassified electrical setback, and reduce the 50' setback to 25' for HVAC noting that a 50' setback may be unwarranted as telecommunication shelters have a Hydrogen detection and alarm system that notifies the network operations center to call the fire department. I 1 ❑ Separate Sheet Attached In addition the following are enclosed 0 Plans/Drawings/Sketches; ®Photographs; ®Product Data Sheets ❑Supplement Information Sheet Other as necessary for clarification of the in€ aril tion p7p.Vddd. Af1pliC,ait s signafurs&Telephone Numberlug Dale/ I, ❑Support, ❑Do NOT Support, this Request for Modification to Connecticut Identify Code by Name,I-a,Fire Safety Code,Oil Burning Equip Coda ( Regulation of Connecticut State Agency Inclusive;as identified above to Section Insect regulalton Number I,e,2e-282-ed,24317.3a,etc. because ofthe following reasons: Identify code flow i.e.occupancy chapter,core chapter as applicable Vf... VAt V.S Loa,! m Separate Sheet Attatfi-d e Fire Marshal Reviewer's Signature/Title Telephone Number DI is Contact me regarding this Request STATE FaE MARSHAL The response of the Commissioner of Public Safety/State Fire Marshal to this request in accordance with Connecticut General Statutes§29-33�5 is attached on a separate sheet nes Initials Slde 2 of 3 i 1 APPLICATION FOR REQUEST FOR MODIFICATION OF A REQUIREMENT OF A FIRE SAFETY REGULATION SUPPLEMENT INFORMATION SHEET If Modification request is for a building or structure,please complete the following: I i Date of Construction: Date of Occupancy for Present Use: Number of Stories(Above grade) Dimension/Area Per Floor: Attic: ❑ Full Basement—#of Levels: Full ❑ Finished ❑ Partial ❑ Partial ❑ Storage ❑ None ❑ None ❑ Crawl Space Type of Occupancy (Check all that apply) ❑ New ❑ Existing❑ Addition ❑ Renovation of building ❑ Change of Occupancy: From to ❑ Assembly ❑ Detention ❑ Residential Board ❑ Hotel/Motel/Dorm Occupant Load: persons ❑ with locking II ❑ Large ❑ Small ❑ Lodging/Rooming ❑ Educational ❑ with locking III ❑ Prompt ❑ Bed &Breakfast I ❑ Business ❑ with locking IV ❑ Slow ❑ 1 &2 Family ❑ Single Tenant ❑ with locking V ❑ Impractical ❑ Industrial ❑ Multiple Tenant ❑ Apartment ❑ Storage ❑ Mercantile No.of Units: ❑ Health Care ❑ High Rise ❑ Class A ❑ Day Care ❑ Hospital ❑ Underground ❑ Class B ❑Adult ❑ Nursing Home ❑Windowless ❑ Class C ❑Family ❑ Ambulatory ❑ Other: ❑ Covered Mail ❑Group ❑ Limited ❑Other: Type of Construction per NFPA 220:(Check all that apply) ❑ Type 1 ❑ Type If ❑ Type III ❑Type IV ❑ Type V ❑ 1(443) ❑ II (222) ❑ III(211) ❑ (21-11-1) ❑ V(111) ❑ 1(332) ❑ II (111) ❑ III(200) ❑ V(000) ❑ II (000) Approved Systems Provided (Check all that apply): ❑Automatic Sprinklers ❑ Fire Alarm j ❑ NFPA 13 ❑ Throughout the Building ❑ Manual Activation ❑ Occupant Notification ❑ NFPA 13R ❑ Partial: Location ❑Automatic Activation ❑ General ❑Zoned ❑ NFPA 13D ❑ Electrically Supervised ❑ Throughout the Building ❑ Voice Evacuation ❑ CSFSC 7-7.1.2 Isolated Hazardous Area System ❑ Partial Location:. Location:. ❑ Water Flow ❑ Special System: ❑ Emergency Lighting❑ NFPA 96 Hood System ❑ Other Activation Means: ❑ Smoke Control ❑ Standpipe; Class: ❑ Other Systems: . Other Information: Seto 3013.