Loading...
HomeMy WebLinkAbout946 Sullivan Avenue - Life Safety System Pre-Engineered Restaurant Fire Suppression Systems Report SERVICE COMPANY DATE OF ER CE TIME A.M. P.M. ANNUIkL SEMi•ANNUAL RECHARGE I7ION RENOVATION -4, 1Cl LOCATION OF SYSTEM CYLINDERS ,�J UL 300 ) ` V L C7 T �'`-l: 1'� r3Ca CJ ❑YES ❑NO IJ r �r ' MANUFACTURER MODEL NUMBER WET DRY CHEMICAL C)� Gu � CYLINDER` R SIZE gTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE CUSTOMER FUSE LINKS 3W'F. FUSE LINK 7: 1 FUSE LINKS 500°F OTHER C .Name 7 Vti .. 'k- t�1 S_ -� ' �c o. /y FUEL SHUTOFF ELECTRIC____ LECTR C GAS SIZE Address C�f �' SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE �h o�1+�j Q.-V I E City �'` State ZIP MANUFACTURE 'S MANUAL REFERENCE I Telephone Store No. PAGE NUMBER: DRAWING NUMBER: DATE Owner or Manager COOKING APPLIANCE LOCATIONS./LEFT TO RIGHT 1. All appliances properly covered w/correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w/correct nozzles 21. Check travel of cable nuts/S-hooks 3. Check positioning of all nozzles. 22. Piping&conduit securely bracketed ` 4. System installed in accordance w/MFG UL lusting 23. Proper separation between fryers&flame r 5. Hood/duct penetrations sealed w/weld or UL device _� 24. Proper clearance-flame to filters 6. Check if seals intact,evidence of tampering _V 25. Exhaust fan in operating order 7. .If system has been discharged, report same 26. All filters in place 8. Pressure gauge in proper range(if gauged) - 27. Fuel shut-off in on position _ 9. Check cartridge weight(If applicable)_ 28. Manual&remote set/seals in place 10. Hydrostatic test date - 29. Replace systems covers 11. 6 year maintenance date 30. System operational&seals in place 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link 32. Clean cylinder&mount , 14. Test for proper operation from remote 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service&Certification tag on system Y_ 19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW 4- COMMENTS: On this date, this pre-engineered fire suppression system was inspected-and operationally tested in accordance with the fire suppressio Syst m requirements of NFPA17 or 17A, 96 and the manufacturer's manual- th the results indicated above. Yz� SMVIINIt TECHNICIAN PERMIT NO.. DATE: TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUTHORITY HAVING JURISDICTION