528 Evergreen Way - Life Safety System T (2)
L j FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY INFORMATION Name of property: GARBANZO MEDITERRANEAN GRILL Address: 504 EVERGREEN WAY , SUITF 598 SOUTH WINDSOR , CT Description of property: RESTAURANT Occupancy type: Name of property representative: Address: Phone: Fax: E-mail- Authority having jurisdiction over this property: Phone: Fax: E-mail: 2. FIRE ALARM SYSTEM INSTALLATION,SERVICE,AND TESTING INFORMATION Installation contractor for this equipment: Address: Phone: Fax: E-mail: Service organization for this equipment: Address: Phone: Fax: E-mail: Location of as-built drawings: Location of historical test reports: Location of system operation and maintenance manuals: A contract for test and inspection in accordance with NFPA standards is in effect as of Contracted testing company: RED HAWK FIRE &SECURITY Address: 55 ROBINSON BLVD , ORANGE, CT Phone: 1-800-888-5197 Fax: 203-891-8858 E-mail: Contract expires: Contract number: Frequency of routine inspections: 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: FIRE ALARM Name of organization receiving alarm signals with phone numbers(if applicable): Alarm: DIALER EXISTING Phone: Supervisory: Phone: Trouble: Phone: Entity to which alarms are retransmitted: Phone: Method of retransmission of alarms to that organization or location: 2 PHONE LINES 0 2007 National Fire Protection Association NFPA 72(p.1 of 5) FIGURE 4.5.2.1 Record of Completion. 2007 Edition ^ 72_34 NATIONAL,FIRE ALARM CODE 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE(continued) If Chapter S,note the means of transmission from the protected premises to the central station: Digital alarm communicator ❑ McCulioh ❑ Multiplex ❑ 2-way radio ❑ 1-way radio ❑ N/A If Chapter 9,note the type of connection: Q Local energy ❑ Shunt 4N/A 3.1 System Software Operating system(executive)software revision level: EST3 5.12 Site-specific software revision date: 17.00.22 Revision completed by: RAY ESTELL 4. SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this system(see NFPA 72,Table 6.6.1): Quantity: 2 Style: Class: B 5. ALARM-INITIATING DEVICES AND CIRCUITS Characteristics of initiating device circuits connected to this system(see NFPA 72,Table 6.5): Quantity: 1 Style: Class: B 5.1 Manual initiating Devices 5.1.1 Manual Pull Stations Number of manual pull stations: Type of devices: Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: Type of coverage: ❑ Complete area ❑ Partial area ❑ Nonrequired partial area ❑ N/A Type of devices: 4Addressable ❑ Conventional ❑ Coded Cl Transmitter ❑ N/A Type of smoke detector sensing technology: ❑ Ionization Photoelectric 5.22 Duet Smoke Detectors Number of duct smoke detectors: G;�, Type of coverage: Type of devices: 4Addressabie ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A Type of smoke detector sensing technology: ❑ Ionization Photoelectric 0 5.2.3 Beat Detectors Number of heat detectors: Type of coverage: Q Complete area ❑ Partial area ❑ Nonrequired partial area ❑ N/A Type of devices: ❑ Addressable ❑ Conventional ❑ Coded U Transmitter ❑ N/A 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: Type of devices 4Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ NIA 5.2.5 Alarm Verification Number of devices subject to alarm verification: Alarm verification on this system is: ❑ Enabled vDisabled ❑ Set for seconds ©2007 National Fire Protection Association O 6 ele / SZ NFPA 72(p.2 of 5) FIGURE 4.5.2.1 Continued `M 2007 Edition FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-35 6. SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of valve supervisory switches: _ Type of devices: Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ NIA 6.2 Fire Pump Type of fire pump: ❑ Electric ❑ Diesel Type of fire pump supervisory devices: ❑ Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A Fire Pump Functions Supervised ❑ Fire pump power j Fire pump running ❑ Fire pump phase reversal ❑ Selector switch not in auto ❑ Engine or control panel trouble ❑ Law fuel Other: 6.3 Engine-Driven Generator Type of generator supervisory devices: ❑ Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A ❑ Engine or control panel trouble ❑ Generator running ❑ Selector switch not in auto ❑ Low fuel Other: 7. ANNUNCIATORS 7.1 Annunciator 1 ❑ Local ❑ Remote Type: ❑ Addressable ❑ Directory ❑ Graphic ❑ N/A Location: 7.2 Annunciator 2 ❑ Local ❑ Remote Type: ❑ Addressable ❑ Directory ❑ Graphic ❑ N/A Location: 7.3 Annunciator 3 ❑ Local ❑ Remote Type: ❑ Addressable ❑ Directory ❑ Graphic ❑ N/A Location: B. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker zones: 8.2 Telephone Jacks Number of telephone jacks installed: Number of telephone handsets stored on site: Type of telephone system installed: ❑ Electrically powered ❑ Sound powered ❑ N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system(see NFPA 72,Table 6.5): Quantity: . 2 Style: Class: B ©2007 National Fire Protection Association NFPA 72(p.3 of 5) FIGURE 4.5.2.1 Contituted 2007 Edition W 72-36 NATIONAL FIRE ALARM CODE 8. ALARM NOTIFICATION DEVICES AND CIRCUITS(continuer!) 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device: Horns: With visual device: Chimes: With visual device: Bells: With visual device: Visual devices without audible devices: Z Other(describe): 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED ❑ Hold-open door releasing devices ❑ Smoke management or smoke control ❑ Door unlocking ❑ Elevator recall ❑ Other 10. SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage 120VAC Amps 8 Overcurrentprotection: Type BREAKER Amps 20 Location(of primary supply panelboard): Disconnecting means location: 10.2 Secondary Power Location: IN FRCP EXISTING Type: Nominal voltage:_24__ Current rating: Number of standby batteries: 2 Amp hour rating: Location of emergency generator: Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: In alarm mode: 11. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens,shorts,ground faults,and improper branching,but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards:(Note any or all that apply.) lqfNFPA 72 V-NFPA 70,National Electrical Code,Article 760 ❑ Manufacturer's published instructions Other(please specify): JOR SPEC , ADDS EXISTING System deviations from referenced NFPA standards: / Signed: Printed name: A r;.tstA- Date: 2/��L— Organization Title: ���{^��� Phone: W —I-YWb 12. RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below,on th date shown below,and were found to be operating properly in accordance with the requirements of NFPA 72 ❑ NFPA 70,National Electrical Code,Article 760 Manufacturer's published instructions ❑ Other(please specify): ❑ Documentation in accordance with Inspection and Testing Form(Figure 10.6.2.3)is attached Signed: // � � Printed name: Raymond Estell Date: 2/26/2014 Organization: RED HAWK FIRE Title: SERVICE TECH Phone: - 7 0 2007 National Fire Protection Association NFPA 72(p.4 of 5) FIGURE 4.5.2.1 Continued ��„� 2007 Edition r FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-31 13. CERTIFICATIONS AND APPROVALS 13.1 System installation Contractor This system as specified herein has been installed and tested according to all NFPA,standards cited herein. Signed:Ze& Printed name: 7C,r5a.c� er:cr� e Date: 2C Organization-o /_e_/ f� ,," Title: Phone: 6 eZ.(`C�-6kA 13.2 System Service Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. Signed: Printed name: RAY ESTELL Date: 02/26/2014 Organization: RED HAWK FIRE Title: Service Tech Phone: 13.3 Central Station This system as specified herein will be monitored according to all NFPA standards cited herein. Signed: existing Printed name: Date: Organization: Title: Phone: 13.4 Property Representative I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications,its approved sequence of operations,and with all NFPA standards cite here' . Signed- Printed name:� ���// 1 �%1 Date: Organization-��ls Title:�/�K ;W'#''fAs Phone: ©2007 National Fire Protection Association NFPA 72(p.5 of 5) FIGURE 4.5.2.1 Continued 2007 Edition W 0