Loading...
HomeMy WebLinkAbout1559 Main Street - Building Plans & Draw REVISIONS MATION FAN UNIT FAN UNIT MODEL ! MODEL HC:FM ESP. RPM NP. P VOLT FLA NI I I I I I I GHT OLDS) A BACKSPLASH 0 I NCAHOFA NCAIOFA 1500 4550 1207 0.500 1 230 4A 10623 13A UNIT OPTION (Oty. - Des(r)FAN WALL I I I m Naor I 1 - Grease Box \ I - /loge Mat - SWps Loose for Curb Supplied by Others lilt 111 III II II BACKSPLASH PANELS ' SLIDE INTO DIVIDER BAR U > - AVAILABLE IN VARYING HEIGHTS .- AND LENGTHS ® a - EASILY CLEANABLE ONE PIECE BACKSPLASH AVAILABLE ` AT HEIGHTSO 1 FT. OO LESS AND L AT LENGTHS OF 6 T.FT. OR LESS v+ 11 W , Fix 01 NIMUWA- rnHusT FAN x a S 30 1/4 FEATURES, -ROOF MOUNTED FAMS .i RESTARAO "m ULM AND mm AMG SOUND AND AIR CERTOtCB VIRING FROM MDTO(TO DISCO SWITCH SWIT FACTORY C-CFWOEL - WEA� DISCONNECT -FOOT TEAT OPERATION 3WT 049Ya WRAPPER Fl1C lTED WALL a -CEASE HEAT PERATI IIN IESf 14 W ¢f vI SCREW OR NORIML TDIPOWTURE TEST PCIP-RIVET 9 12 E*KW FAN MUST OPERATE COTTRIUMMY WHILE EAAUSTDI6 AIR AT 300T(14M ppS ITIIH SOTTO( TO+ IF Fm0 F TD SII�WALL R UNTIL ALL FAN PARTS HAVIC REACHEDLpNGE ppS SIDE WRAPPER A TO THEFAN WHICH TD VAL{. REASE DRAIN WOULD CA16E UNSAFE O+ERATIOL / ¢ AlAetaAL rLARE-UP TEST FTRCH REWIRED INSIDE 1F FRONT PANEL Emv= PAN Oai aPmTE CONONIDUSLY SIDE 6 HOW WHERE SEAM !EFTS WHILE EANUSTING ROaONG GRL%= VAPORS T13P SEA( ON !® WALL AT MOST S WITH FOR A PCW®6 IS 60117 S 1M FO THE FAN BELONG 13 1114 DAMAGO TO AMY DIONT THAT COLD CAWS INSIDE 11F SIDE PANEL 16 1/4 32 1/2 AM UNSAFE CONDITION. 21 � 0 MX �KITT SMM LOOSE FOR CURB SINFL®BY OTHERS WRAPPER DETAIL REAR WALL ATTACHMENT TOP HOOD SEAM DETAIL SIDE WALL ATTACHMENT F— U DUCTVORK BETWEEN E%NWIST RISER ON H®D AND FAN (BY OTHERS) '0 O INSTALLER70 DT PLACE FRT PANEL FASTEN WRAPPER WRAPPER PANELS OF SIDE 90 DEGREE BEND POP-RIVETINT13 POS AND IT ON ON C-OOANIEL RIGIFLANGED FOR 6 = 3 DITY WALL- S —WRAPPER END O -P In 3 �g � 0 DATE: 7/20/2012 OWO.aYT WRAPPER 1556964 FRONT SIDE WRAPPER PAEL CAtGPY H® FAD DRAYM By.SAC PON-RMTS SCALE: FRDNT PRESS F17 UNTIL 3/4e - 1'-0- WRAPPER PANEL FACES ARE FLUSH CUSTOMER APPROVAL TO MANUFACTURE, PANEL VITH HOOD AND POP RIVET ON SCREW PANELS TO C-CNMNEI. Approved as Noted ❑ Approved with NO Exception Taken ❑ FRONT CORNER ASSEMBLY COMPLETED WRAPPER ASSEMBLY Revise arW Resubmit ❑ SION7m SHEET NO. Your Tmw Date 2 C.L.WARD e Forms WC High Temp 9 Access Doors a.vs w eu an N t� W s m o _ IL �� N mo6s n 12X12 MUA DUCT WITH INSECT SCREEN G . ,, orE O m b m-o m ° AND ELECTRIC DAMPER TIED INTO SUPPRESSION SYSTEM C m uo� Qa V O N m E o -v � °mS W «bmm ma U) 71 v O m9 U-K-6 aUr m4 E 9 0 �3- u - — N rU2- ma_a9 QK E o C r SEE EF DETAIL 16XB EX DUCT •Ia U ' o t 8 _ J Fes' NEW STEEL STUD AND DRYWALL v ..Eb u pmrj = mEn u� ue --------- ---------- --- ------ _ ----------------- -------J m m N m C (n r-N V..NNNm / �C ZERO CLEARANCE WRAP w.�bcamesemt Liam ACCESS DOORS yxw.-Ieyr r.ro na.w:y EZ 1��Rp ,5 DUCT HANGER Duct Insulation — Single—Layer System v�llF�Ep FAN & LIGHT 't SNITCHES C S'L I111 a ma::we auo-m 'n pLAIJ VIEW — Hood Al Puo 6' 0.00- LONG 4218SND-2 6� 3 �g S Sk C9 Y � o' s r• �m8 c= d ig ILa1 � m3� N`j AM Q O ^ E It 3 T6a5�5 " TS REVISIONS s °"AN°' T. DUVAL 8/4/12 24 MAINLINE DRIVE REVI DESCRIPTION DATE gTDTD — A ORIGINAL RELEASE 8/4/12 CHECK T. DUVAL 8/4/12 WESTFIELD, MA. 01085 MASSACHUSETTS LICENSE: CS 6 PHONE: 4139954 ( ) 568-4663 NOTES; CONNECTICUT LICENSE: SMS #68 FAX: (413) 568-4665 1. GREASE HOOD EXHAUST DUCT TO BE 169a. STEEL WELDED LIQUID TIGHT. MASS JOURNEYPERSON UNREST. 95011 "".:"' ""'�'.........''"""`""'' '' DRAmN°N0. 2. MAKE—UP AIR DUCT TO BE 24go. GALVANIZED STEEL INSTALLATION DRAWING 0000000-00 3. 10' MINIMUM BETWEEN EXHAUST FAN AND MAKE—UP AIR FAN. ALL INSTALLATIONS WILL MEET NFPA96 4. WALL—MOUNTED EXHAUST FANS TO BE A MINIMUM OF 10' ABOVE GRADE. AND IMC,2008 EDITION CODES. SITE INFORMATION: PROJ.No. 8858 5. BOTFOM EDGE OF HOOD FRONT TO BE A MINIMUM OF 6'-6- ABOVE FINISHED FLOOR. o REVISION A 6. 3/8- THREADED ROD TO BE USED TO SUPPORT HOOD AT HANG POINTS. THIS DRAWING AND ALL INFORMATION CONTAINED WITHIN IS SITE LOCATION: MASONIC LODGE 7. ZERO CLEARANCE DUCT WRAP TO BE USED WHERE 18- TO COMBUSTIBLES CANNOT BE ACHIEVED. 4 THE EXCLUSIVE PROPERTY OF ALLSTATE HOOD & DUCT INC. DWO.SIZE C 8. CLEANOUT (ACCESS) DOORS TO BE INSTALLED IN EXHAUST DUCT AT CHANGE OF DIRECTION. ANY REPRODUCTION OR OTHER USE FOR ANY PURPOSE SITE ADDRESS: 1559 MAIN ST SCALE9. EXHAUST FAN DETAIL WITHOUT WRITTEN CONSENT IS STRICTLY NONE 1 PROHIBITED. *ALLSTATE HOOD & DUCT INC. 2008 CITY,STATE: SOUTH WINDSOR CT SHEET 1 C.L.WARD O 4 PAi18YMC High Temp Access Doors w.sewaav Y! � as W Ym IL d q a C m m v v o m $E m yn O �s m 3 O C M p V V m g D an d H moEwoo2 2ND FLOOR � d 3/8 ALLTHREAD d C n o;:a sa w E•Cc o� �9 s" c o TTnn art wulcr nlan () N.n i� v a.�+.a vo .RfdL V w%M M TNSIMnm EMI., IMALUa tt�W�N¢M OMMTIi[ SWAM W „ O n V•r Hl'SS HILTLC VITA r�, . UIU�NUINO Dfrobw STN IB•IOl Duct Insulotion — Single—Layer System M +er wa OW FO AXE OW wwxw ww emr H&il X 72M Ulf. 0 er Irr iTP. gbgm 8d 6 fi Y by �• & x sR W A� �1 ss SECT/ON F7BII — YODEL 4278SND-2 W 0 s_ n ' U) p a * ; a ; ,$ 9� U 9 Blsiaz__9�S��e k �w»W 16 E REVISIONS s °RAY"I T. DUVAL 8/4/12 ` 24 MAINLINE DRIVE REVI DESCRIPTION I DATE jDFrjApR A ORIGINAL RELEASE 8/4/12 TD TD s� F� CHECK T. DUVAL 8/4/12 WESTFIELD, MA. 01085 PHO NE: 413 MASSACHUSETTS LICENSE: CS 66654 ( ) 5684663 NOTES; CONNECTICUT LICENSE: SM5#66 "'!�" FAX: (413) 568-46G5 1. GREASE HOOD EXHAUST DUCT TO BE 16go. STEEL WELDED LIQUID TIGHT. MASS JOURNEYPERSON UNREST. 25011 0RAWINO NO. 2. MAKE—UP AIR DUCT TO BE 24ga. GALVANIZED STEEL. INSTALLATION DRAWING 0000000-00 3. 10' MINIMUM BETWEEN EXHAUST FAN AND MAKE—UP AIR FAN. ALL INSTALLATIONS WILL MEET NFPADB 4. WALL—MOUNTED EXHAUST FANS TO BE A MINIMUM OF 10' ABOVE GRADE. AND INC,2008 EDITION CODES. SITE INFORMATION: PROD.NO. 8888 5. BOTTOM EDGE OF HOOD FRONT TO BE A MINIMUM OF 6'-6' ABOVE FINISHED FLOOR. REVISION A 6.3/8- THREADED ROD TO BE USED TO SUPPORT HOOD AT HANG POINTS. z gg ' THIS DRAWING AND ALL INFORMATION CONTAINED WITHIN IS SITE LOCATION: MASONIC LODGE 7. ZERO CLEARANCE DUCT WRAP TO BE USED WHERE 18' TO COMBUSTIBLES CANNOT BE ACHIEVED. 0 THE EXCLUSIVE PROPERTY OF ALLSTATE HOOD & DUCT INC. DWO.SIZE C 8. CLEANOUT (ACCESS) DOORS TO BE INSTALLED IN EXHAUST DUCT AT CHANGE OF DIRECTION. ANY REPRODUCTION OR OTHER USE FOR ANY PURPOSE SITE ADDRESS: 1SSS MAIN ST SCALE 10. WHATSOEVER WITHOUT WRITTEN CONSENT IS STRICTLY NONE EXHAUST FAN DETAIL PROHIBITED. 0AUSTATE HOOD & DUCT INC. 200E CITY,STATET SOUTH WINDSORCT SHEET 2 REVISIONS MAX. rASM W I� MODEL LENGTH CDO(BG T17TAL TOTAL CMSTR ET10N RISER END TC Raw QUANTITY LOCATTaH TEMP. EXH. CFM WIDTH LEN& DIA CFH SP. SUP. CFN WIDTH LEND. DMA. CFN S.P. ENHOOD AUST DICAKOE�p(f LIGHT nX11=-)GBH TEMP FRONT ASSEMBLY. INCLUDES CLEAR YIEIMX.AND 1 421H 6. OAO' 450 15� 10' 14' 5500 -0.318' 0 430 SS ALONE ALONE I FAN RIGHT semis NESISTANT ranBE a35 rairm SND-2 DBe Wh+47� ere Expcsetl 1 LIGHT FACE V LAYER OF DaU ATIMN FACTORY INSTALLED I I FIRE HOOD ON TM IF 1®.MEETS H INCH TO NIL TYPE OTY HEIGHT LENGTH TY TYPE WIRE LDCATIQ4 M[IANQ HOOD M;T, OFACES 2 FOt CLEARANCECO TIULE I I D TYPE SIZE N®EL R QUANTITY PIPING VG HT 'H' FIELD%all at ISM MGM 2 20' I6' (SEEOPTIONSO I I 1 SS Baffle with HnmAes 2 20 20 2 Tncandexerrt Light Flit NO Nn 294 FIELD CUT EXHAUST RISER 1® TA1AE) LBS NVAO G ANGLE I I f I E 2 I� 2 � Filter Detail IIIII1 NO, OPTIM 1 FIELD WRAPPER 1300' Mph Front, Lrft, Right 3•INTEHttMI STANDOFF O'NOL 2 HPCKSPLRSH ROAD' High X 72.00' Long 430 SS INSULATION FOR T13P OF HOOD � w n tOt Zr IGN ICleen-Crud BeBle'!'ylx Fillets arc TJI.OnasiGed Grease EswLcdng Filters. MEA#I6&78-MAlaminumINFORMATfOhr ® LL FAN 4H0'N4X MEA#2i7-96-ESrninlaa = m INt FAN UNIT M®EL R MODEL TAG CFM ESP. RPN M.P. 0 VdT fLA 1GHT HLHS�SDNES � � namTANmvsnBlww-ro�suxru.�tm+ ® W m WITH M WAIM uP ^' 1 NCAIDFA NCAIDFA ISM 0550 1207 0.500 1 230 AID IOG23 134 x 7722m Upa �' Y yp ®® d w Sir An' Tw. A 'ZFAN S OPTIONS UNIT IPTICN (Oty, - De .) NIL ERDPIEIIT 1 1 - Grease Box BY OTHERS n. .u. i 1 - Hinge Xit - Ships Loose for Cv4T SWppUed by Others AMWW(Tpm/m/s) CALCULATIONS UTILIZED to EMW(SIAHDCtx OF HIGH x HBM/IRTI.(U^') SOD ON-EMET CW X RRCERM ROM SECTION VIEF — MODEL 421 8SND-2 row.DUCT ANA.144 X Hri W) rNl.1 NG1(IFA �FIHNIST F/JI IODL 00 NSA DUCT Locr� wCT OPO SO 1/4 FEATURES. 'OM-M MM M M OE MMU M M MW II3mIYR mo-m RR AO A ORT BOOR OF WHO ROF HOUM FANS 110307AlTTMBYfm 11011111 AIOMMLI 98 RESTAURANT HIM M705 AND UL762 BUILDING CODES -AMCA SOSB MID AIR CERTIFIED -VIROG FROM MOTOR TO DISCONNECT SWITCH -WEATHERPROOF DISCONNECT HIGH HEAT OPERATION 300-F C149-0 '�'•Its GREASE CLASSIFICATION TESTING ••r USR* are,fat-4 27 V4 NEIR lAL TEMPERATURE TEST CONTIMUCIALr .emu m e n.m ram 21 1/2 EXHAUSWILE T FAN MUST EXHAUSTING RAT SOOT 04M Y -� I — � IV X Cut :M�� T V U TIL ALL FAN PARTS HAVE REACHED Ex x 14' L — t ms wmmva w�eu THERK%L DETERIORATING EFFECTS AND VIHWTE FA WHICH V0.lD CAUSE VISAFE CPERATICK YIOC1 O EASE I1RA3N NSF. U) -� AHRrMAL FLARE-UP TEST 4e EXIURM FAN MOST OPERATE COUTDAKLIS-Y AT 60WF ®FOR A PENID13'S VAfO� Ill.LMAtetl IneaMtacmt Lvvt 13 KNO E5 WITHOUT THE FAR BECOMING Fhty Hlgh Tang A ZvAtXY 1/2 Pint Grease Cup Detail = �i 13 V4 DANAM TO ANY EXTENT THAT COULD CAUSE 36 1/4 32 1/2 AN UPOAFE C 173 am= ® ® in -}-s GREASE BOX in el HOdE KIT-- SHIPS i.®SE M CIRiH SUPPLIED BY OTHERS FAN & LIGHT 1E ? x 0 1 DATE- 7/20/2012 DUCTWORM( BETWEEN SWITCHES AIDI FAN RISER ON Don theenside mull of the The grcue will 1556964 drain d=ugh a conceeled grease trough and into this=oveilile cap. DRAWN PLAN VIEW - Hood Al BY.SAC 6' 0-00' LONG 42185ND-2 ND-2 HANGING ANGLE DETAIL SCALE: ./ta.0 vme.m Wra town cr 3/4• ea i'-O• fs6'IDAIIO Js e[AW/D et ib ARIG.Iwal IAar if CUSTOMER APPROVAL TO MANUFACTURE. Approved as Notts ❑ Approved eKh NO Exceptbn Token ❑ RwAse and ResdwAt ❑ SIaNTWE SHEET NO. Y. ltde rate .wsemmwuwse wumrw mo.en 1