HomeMy WebLinkAbout27 Spielman Road - Life Safety System Te (2) SECURIff *Quality DMANARK MEMO IF CENMRS Alarm Systems Since 1985 P.O. Box 1170 'Owned 610007--Noo� 0 1 0 A ARK JVS "Notionally Known, Locall " Tolland, CT 06084-1170 LIC #181641 Tel. (860) 872-4050 Fax (860) 875-0493 Rising Stars Child Care DynamarkCT@comcast.net 27 Spielman Road South Windsor, CT 06074 Date: 10/31/2012 I- RE: ANNUAL FIRE ALARM TEST Attached is a copy of the "INSPECTION AND TESTING FORM". This form was completed upon testing the fire system in your building, as required annually. A copy must be kept in a file on the property for a minimum of three [3] years and available if asked for by a building official or fire marshal. Michael G Casieri CC: Fire Marshal WO# 0296 Ofessed 6e the Lord my rock my refuge and my fortress, my stronghofd, my deliverer, my shieffin whom I trust. PSALM 144 INSPECTION AND TESTING WO#: 0296 DATE t®Grl SERVICE ORGANIZATION PROPERTY NAME(USER) NAME: Dynamark Security NAME: Rising Stars Child Care ADDRESS: P.O. Box 1170 Tolland,CT 06084-1170 ADDRESS: 27 Spielman Road REPRESENTATIVE: Michael G. Casieri South Windsor,CT 06074 LICENSE NO.: 181641 TELEPHONE: (860)528-7529 TELEPHONE: (860)872-4050 CONTACT: Jeff or Rene Welsh CHECK HERE IF MAILING ADDRESS IS DIFFERENT MONITORING ENTITY APPROVING AGENCY CONTACT: CONTACT: South Windsor Fire Marshal TELEPHONE: ADDRESS: 1540 Sullivan Avenue South Windsor,CT 06074 MONITORING ACCOUNT#: NOT MONITORED TELEPHONE: (860)644-2511 ext.217 TYPE TRANSMISSION SERVICE ®-Digital ®-Annually PANEL MANUFACTURER: Firelite MODEL NO.: MS 5024 UD DATE INSTALLED: 6/20/08 CIRCUIT STYLES: B NO.OF CIRCUITS: 5 SOFTWARE REV.:N/A LAST DATE SYSTEM HAD ANY SERVICE PERFORMED: Added additional equipment&Fire Test 7/18/2011 ALARM INITIATING DEVICES AND CIRCUIT INFORMATION QTY CKT. STYLE 5 MANUAL STATIONS ION DETECTORS 20 PHOTO DETECTORS DUCT DETECTORS 2 HEAT DETECTORS WATERFLOW SWITCHES SUPERVISORY SWITCHES OTHER:(SPECIFY) POWER SUPPLIES: Primary(Main):Nominal Voltage 110V ,Amps: 15 Overcurrent Protection Type Breaker Amps: 15 Location(Panel Number): Basement Disconnecting Means Location: #5 b. Secondary(Standby): Storage Battery#1: Amp-Hr.Rating: VDC AH: Installed:6/08 Storage Battery#2: Amp-Hr.Rating: 7 VDC• AH: ® Installed:4098 Calculated capacity to operate system,in hours: 24 1 60 TYPE BATTERY ®Sealed Lead-Acid PRIOR TO ANY TESTING NOTIFICATIONS ARE MADE: YES NO WHO TIME MONITORING ENTITY ❑ I ❑ BUILDING OCCUPANTS ❑ '�"� BUILDING MANAGEMENT ❑ ❑ OTHER(SPECIFY) ❑ ❑ AHJ(NOTIFIED)OF ANY IMPAIRMENTS ❑ ❑ SYSTEM TESTS AND INSPECTIONS TYPE VISUAL FUNCTIONAL COMMENTS CONTROLPANEL C - INTERFACE EQ. ❑ ❑ LAMPS/LEDS ❑� Di FUSES ❑' PRIMARY POWER SUPPLY TROUBLE SIGNALS DISCONNECT SWITCHES ❑ ❑ GROUND FAULT MONITORING ❑ ❑ SECONDARY POWER TYPE VISU FUNCTIONAL CO MEN BATTERY CONDITION tl LOAD VOLTAGE -� DISCHARGE TEST CHARGER TEST ❑ 72-115 INSPECTION.TESTING.AND MAINTENANCE SPECIAL PROCEDURES I COMMENTS: ON/ PREMISES MONITORING YES NO TIME COMMENTS ALARM SIGNAL ❑ ALARM RESTORAL ❑ ❑ TROUBLE SIGNAL ❑ ❑ SUPERVISORY SIGNAL Nr ❑ SUPERVISORY RESTORAL ❑ ❑ NOTIFICATION THAT THIS YES NO WHO TIME TESTING IS COMPLETE: BUILDING MANAGEMENT ❑ MONITORING AGENCY ❑ ❑ �. BUILDING OCCUPANTS ❑ OTHER(SPECIFY) ❑ ❑ SYSTEM RESTORED TO NORMAL OPERATION: DATED-&-l TIME �a THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS. NAME OF INSPECTOR: , DATE-.,(O J SIGNATURE: ! s NAME OF O ER OR REPRESENTATIVE: �v DATE: SIGNATURE: ? �'