Loading...
HomeMy WebLinkAbout80 Kimberly Drive - Correspondences - Fi e East Hartford,CT RD Phone:860-289-1100 Fax:860-289-3272 R U SIS F—i.:L- & DAWSON Stamford,CT A tx C•H t r E C;T u R B & P-x O r rr U R is[rrcr Phone:203-653-2335 Fax:203-653-3526 TO: Walter Summers, South Windsor Fire Marshal FROM: Thomas A. Manning, AIA � Thomas A Manning 2012.03.19 18:46:26 -04'00' DATE: 3/19/2012 RE: Metals Testing Company 80 Kimberly Drive South Windsor, Connecticut File No. 12.038 This is in response to your request for a brief narrative regarding code compliance at this project. This is a mixed business and industrial occupancy using hazardous chemicals. I received a list of the chemicals, which is attached. I have requested MSDS from the owner. Pending receipt, I have classified the industrial occupancy as H-4 based on the information about the chemicals that I have been able to obtain online. They appear to be primarily corrosive and toxic. Methanol is a flammable liquid, but does not cause classification as H-2 or H-3 in the quantity listed per Table 307.7(1). The employee lounge is classified as accessory Assembly. As an H-4 occupancy, the building is able to take advantage of the area increase for sprinklers in 506.3. With the addition it is well within the allowable area for nonseparated mixed use per 302.3.1, so rated separations are not required per Table 302.3.2. There is a requirement for rated separations in 415.8, but it does not appear to apply to this plan. The mezzanine is partially closed, and the closed portion has an occupant load of 6, well under the 10 permitted by Exception No. 1 to 505.4. The common path of travel to the bottom of the stairs from the most remote corner is 75 feet. Although fully sprinklered, the Exceptions to 1013.3 are not available to H occupancies. The area of the mezzanine is 1240 square feet. It is open to a room 8500 square feet in area, so well within the limitation of 505.2. Mezzanines are permitted in H occupancies. If you have questions, please call. I am usually at(860) 679-4197 during the day. I am working on assignment away from our East Hartford office. You may also contact me by e-mail at thomas.manning@russellanddawson.com or tmanning@uchc.edu. c: file Christopher Dougan, Building Official R:\PROJECTS\N-YR-2012\12.038 Metals Testing-South Windsor,CT\R&D Code Compliance\WS120319 Memo.Doc Website:www.russellanddawson.com Email:info@russellanddawson.com RUSSELL AND DAWSON LLC- 1111 Main Street-East Hartford,CT 06108•TEL:860-289-1100-FAX:860-289-3272 CHIRAG B.THAKER,PRESIDENT•DAN LYMAN RUSSELL,ARCHITECT•ROBERT M.DAWSON,III,PROFESSIONAL ENGINEER DELISLE INC.,0115 A,METALS TESTING COMPANY 80 Kimberly Drive,P.O.Box 69,South Windsor,CT 06074 TEL:(860)289-8225 FAX:(860)289-5970 Jim Simmons Allied Construction Inc. March 2,2012 Mr.Simmons With regards to the new chemical processing facility for Metals Testing Company,the processes and chemicals currently being conducted and stored at are facility now will be the same in the new facility only on a larger scale. Below is a brief description of the process in new facility: 1. Parts received in and sent to chemical processing facility. 2. Parts unpacked/fixtured 3. Parts immersed in alkaline cleaner 4.. Parts immersed in water rinse.tank 5. Parts immersed in etching tank 6. Parts immersed in water rinse tank 7. Parts immersed in anodizing tanks/anodized(if applicable to parts) 8. Parts immersed in water rinse tank(if applicable to parts) 9. Parts immersed etching/desmut tanks(if applicable to parts) 10. Parts immersed in water rinse tank 11..Parts immersed in hot deionized water rinse tank/blown dry 1.2.Parts inspected/repacked 13.Parts sent to other departments or back to customer Below is a list of chemicals that will be used and stored in the new facility.These chemicals will either be in drums from the manufacturer or in our processing tanks in diluted amounts. Chemical Approx Chemical Approx Name Amount Name Amount Acetic Acid 150 gal Methanol 110 gal Acetone 110 al Nitric Acid 800 gal Ammonium Bifluoride 300 lbs Phosphoric Acid 100 gal Aricid-B(Acid Salt) 5000 lbs Soda Ash 200 lbs En re 576(Alk-Cleaner) 2400 lbs Sodium Hydroxide 2000 lbs Ferric Chloride 2400 al Sulfuric Acid 400 izal Hydrochloric Acid 800 gal Trisodium Phosphate 1000 lbs Hydrofluoric Acid 200 gal Turco Vitro-Klene(Alk-Cleaner) 2000'lbs Lime 2000 lbs Anthony Bruno Special Projects Manager t t