HomeMy WebLinkAbout45 Connecticut Avenue - Building Plans &amp; (3) i 6 SPRINKLER NOTES 1.)SPRINKLER SYSTEM INSTALLATION SHALL BE IN ACCORDANCE WITH NEW 6"2 TEE SPECIFICATIONS AND DRAWINGS. CODES.NFPA- 13 GUIDELINES.AND ALL APPLiCr\BLE.STATE AND LOCAL MECH.TEE - T ''m/TTERFLY D EXISTING FEED TO CROSSMAIN A B C CHAIN OPERATED p E F G H _.)ALI.PIPING PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED TO MAINTAIN INTEGRITY OF ITS FIRE RATING. 3.)PIPE&FITTINGS:ALL NEW SPRINKLERS SHALL BE NFPA 13 APPROVED. ' SCH.40 BLACK STEEL ASTM A135.THREADED WITH STANDARD CAST IRON ' SCREWED FITTINGD OR ROLLED GROOVED WITH'ViCTAULIC'OR EQUAL GROOVED TYPE FITTINGS.OR SIZES 2"AND UP SCH. 10 ROLLED GROOVED '1-0 WITH'VICTAULIC'OR EQUAL TYPE GROOVED FITTINGS. 1 - _ u-'� `" ULLJ - -- -- ---- 4. OW R IS RESPONSIBLE SPRINKLER TOMAIN T N 40 MINIMUM TEMP. IN ALL _ _ -� o-� `- °- °_N d� 9 4.)OYVNERISRESPONSIBLETOI.'L41NT41 deep i � � --- - -- — �l � AREAS• H ET E. ® ® ® ® ®® ' � ® ®Is ® ®® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ®® ® ® ® ® ® ® om � ® � s® ® � ® ®I® ® s® ® ® ® �1 ® ® ® s® ® ® ® ® ' = 21-0 21'-0 �qII '� �. 5.)BUILDING CONSTRUCTION IS COMBUSTIBLE �. 2LL 0 5h tl �. s J31-0 _... uj A. STEEI. 63 B. WOOD C METAL STUDDED PAR7'1'rION p° z C.FIRE RESIS7:4NPACOUSTICAL AND SHEETROCK CEILINGS. a a a ° a a (1) 6."1 ALL COMBUSTIBLE CONCEALED SPACES ARE TO BE PROTECTED PER ° IX NFPA i.'13 —®— ° _ 3'-7% s•-2 Fi •_t ' 'a -� a ° a a — a a 4 4 r.)ALL SESIMIC RESTRAINT REQUIREMENTS OF LOCAL AND STATE rpm^ JURISDICTION WILL BE INSTALLED PER CODES ON NEW PIPING. I' —I °RED ° ° N 4'-10 [ 3 HYDRAULIC CALCULATION SUMMARY_ o ® EXISTING CEILING SPRINKLERS : 4'-10 +�' NEWADo1rION EXISTING CEILING SPRINKLERS [ RISER BODYCOTE THERMAL PROCESSING ® _ a \' , �' 17 O 11/4" MAIN DRAIN w 45 CONNECTICUT AVE. SOUTH WINDSOR CONNECTICUT N a'-7Y, s'-2 3�-1 - I E 3 1"TEST& DRAIN RIG E 1 (PARTIAL MAIN FLOOR) 05/21/12 zZ) as EXISTING SPRINKLER VALVE R OM rr, C 3 �v ® @ ALARM VALVE �16 BRAZEOFFICE CiW --®- - �. ;D2 d I' 1 WATER SUPPLY DATE: 05/21/12 TIME: 11:30 am — _ - — - --- ,II �o Ordinary Group ll•0.200gpm/ft2 for 900.00 +2 ° PROVIDED BY: MFPD&D �Lc3----_ r --Bg— . STATIC PRESSURE' 84.00 PSI Ewb RESIDUAL PRESSURE. 66.00 PSI - yti7o1B3 f 1 FLOW�A 1250.00 GPM E Z B JLER - - rn: v 106 v 111 2 M, I �L L~ EXISTING SPRIN FI ERVICE 11 ' E BOOSTER PUMP C u�i° 7 -� ,o,� -0� 1t'�i I CHURN PRESSURE: 00.00 PSI 6 RAZE ROOM D.LC.L. PI E& FIT S BRAZE ROOM- 12 Lo 13 1D ma o I E 4 RATED PRESSURE: 00.00 PSI L UjW i 1s v 6 0 as _1? 0 6,-0 a r RATED CAPACITY. 000.00 GPM -_ z -- C � _ 6 -T DC SPRINKLER-C_ALC�JIAILQN— 3 0 0 --- �'a � , — - --- - -- - o' TYPE OF SYSTEM: WET 1OB 11D s•-s t,'-toz ' CONSTRUCTION: NON-COMBUSTIBLE _ t L��' 1a r 1Be ,B7 PI- O], UP NE -SIDEWALL 24'-0 5 ) I " ff SPRINKLERHEADS UNDER STAIRSI ti I HAZARD`'CLASS: NFPA 13 / ORD. _ In m �I U :� I , �- — — — -_ -"— — J_ I 'J / - �- E DESIGN DENSITY: 0.20 GPM/Sgft. I _ _ 4 REMOTE AREA: 900 SQft Ia 9 Y0' v; -- - • uj s 4Y2 r 9 L NUMBER OF HEADS CALC'D 22 LOWER MEZZANi NUMBER OF SPECIAL HEADS: 0 E co E o ((D HOSE DEMAND (inside): 0 GPM L, N OJ I' nIM1 �y FaeeABwsrs � Z HOSE DEMAND (outside): 250 GPM j ^J ti 1 RACK SPRINKLER DEMAND: 0 GPM r 12'-0 s'-„7•_g 2'-10' / w. AVAILABLE PRESSURE: 80.814PSI ; to TOTAL SYSTEM FLOW. 490.24 GPM @ SY M ' Lo 8 (including hose demand) F17 1 M r F7 M M 711771 F17 III OPERATING PRESSURE- 48.312 PSI U a'-si a 7oiL PRESSURE REMAINING: 32.502 PSI 1 wm BREAK ROOM - 0 N o Co ORDER ENTRY �, - -- -- - SPRINKLER HEAD CALCULATED SYMBOL: 115 O z EXISTING SPK. RISER SECTION NTS JUNCTION NODE SYMBOL: 23 - 1 , a FILE CABINETS ' 4'-6 7'-10% ti' 1 4'-4'/, SWAITHL W IL%C�SPACG FOR LATEMU S,LND LONGI'TUDLNATS SILV.L BE 40',WO SO' --_I RESPECTIVELY FOR ALL NEW MAIN PIPING. G UND LEVEL I SfiYH01� 1¢HDI� EIAREGL[NGi111 1]IH'[1ApEG LFN3FIQ p FIG O FIG BID ¢ .„ YPICAL U 1%•OVFKCIEELEBE �CN a4''9 1'BLACK STEEL PIP us ILO:GTBBOxrLEKCEED T01 ILn+GTHNGTTOSE:EEGT{p p k.� UPPER MEZZANINE HGIU]0 Ho.1. FASLCweP v I -kASTCWAO LATERAL BRACING LgiERAL BMGING FOR M41N56'60' FORINUNSUP104 ' L Hot IXG __. _ IXHDI Is LEN3TH1 11C.I. FIG.B18--- 10 WACA` TYPICAL SWING-ARM DETAIL -`- Q 20-O 24'_11 2 IH'DLACK STEELD.40,PIPE POLACK D.40)TEEL PIPE - 19-'I'I p'-<} 19'-0 ISCHEOAOI (3CHEGA01 212PIPECLMIP 213 PIPECLNAP �� LONGINJUINALBRACE LONGITUDRNLBRACE VV FOAIAAIN50•&P FORAWNSUPT04- I r ^\ \ N KLER PLAN SCALE: 1/sll = 11—(� FIG IBM FIG.IBOO -�//// �,\ 1� F0.5TRWAP FAST CLN.IP STEEFIG L PIPE. FIG.1000 � / ���/ T N FAST CWAP FASTCWAP /\\/\����/� I-BLACK STEEL PIPE S 0— (SCHED.401 - 1-eLACK STEEL PIPE IS[HEDA01 'IN "- ' WPIC \ TYPICAL FIG 910 IYPICAL­ 12V,'EIABED LENGTHI TYPICA - FIG.010- - RY.'EMOEULENGTHI PICAL FIG.IOOOFASTCLPAIP RISER BRACE FIC 1000 FAST CWAP (FOR ALL FWN RISER OWAETERSI RISER BRACE E DATE REVISIONS SYMBOL HARTROUAICE.SWAYDRACE DETAII 4 AND COMBIONF.NTS SWAYBRACE LOAD CALCULATIONS PIPE BRACE BRACESPACING ASSIGNED NFPACI3 --""---"- — -- - SIZE SIZE EAT LONG LOAD TABLE4-6.4.3.53 TYPEWI Im&) BRACETYPE MA%LOAD VALUE MULTIPLYING FACTOR=0 8' I%•SCHAD 10. fi0' 2196 TYPE B• , W'DOLT 2857 NKLER HEAD LEGEND 6' I%'SCHAO AD- BO' 2088 TYPE-W SM'BOLT 2857 _ 5CHAO B0' 392 TYPE-W In'BOLT=i782 SYMBOL TYPE �-RESPONSE ACTION MANUFACTURER MODEL TEMP ORFICE 'K' FINISH COUNT 3• SCHAO 41' aO' 3a TYPE'B' W-BOLT=1782 1.SCHAD 4D' BO' 1256 TYPE•B• In'BOLT-1702 ONNECTICUT PIPING & TESTING, LL N PENDANT QUICK NEW RASCO F1FR 155"F 1/2 5.6 CHROME 6 T 355 SACKETT POINT RD. QUICK NEW RASCO F1FR 155'F 1/2 5.6 CHROME 19 NORTH HAVEN, CONNECTICUT 06473 UPRIGHT �\ !� TEL: (2B3)2aF�p502 Q A Cr.uc NO: r't BOIfl 388 FLulE: ---T NG SCALE: 1/9 = 1'-0 %ISTIN L-kB& FEEC /NEW CAFETERIA ERI O E5 CONNEC"FiCUT AVENUE \` C?SETERL4 LTC.NO OOOo24 - -'-- ---- ----- ..._.— --- ---- JASO IMMONs O' �� �C� ��� SOUTK WINDSOP.. CONNECTICUTSTATE OF NNECTICUT v DMt\MB1': is 1011 NO: A-TE[ D5/14/12 - - TEC ICIAN clmLUB m': A, SCAT.E: ASNOTED " I N.0 t N A.L I M BRAZING RMS.FIRE SPRINKLER PLAN TOTAL THIS PAGE 25 O 1 TOTAL -- - - - --- - m �q EW:IDDITION FIRE SPRINKLER PLAN 11/ V S