HomeMy WebLinkAbout63 Gerber Road - Building Plans & Drawin MATERIAL LIST - NOVEC 1230 SYSTEM 15 1 6 ITEM OTY DESCRIPTION PART NUMBER REF. DWG. 14 ICJ 1 1 200 LB. NOVEC CYLINDER 45-100200-001 K-45-2040 17 2 199 LBS. NOVEC AGENT 47-190000-001 K-45-1900 16 ROOM INTEGRITY 3 1 OUTLET ADAPTER WK-283904-000 K-45-2100 The Stuart L. White Company does not assume any responsibility for the integrity of the q 1 STRAP WK-235317-000 K-45-8130 15 12 13 protected hazard/s. The owner or general contractor must insure that all penetrations, holes. cracks. and openings are sealed prior to the system startup. Any doors or windows in the 5 1 CRADLE WK-235431-000 K-45-6150 protected space must have weather stripping in order to assure a tight seal against leakage of the NOVEC a ent. All ductwork must have tight fitting dampers to stop any airflow into or 6 1 24V ELECTRIC CONTROL HEAD 62-466500-010 K-45-8017 out of the hazard: Any floor drains must be sealed and tested for tightness prior to any room integrity testing. 7 1 AEGIS CONTROL PANEL 64-732001-001 64-100 9 ll 8 2 12 VOLT BATTERIES 06-115915-013 64-100 9 2 PHOTOELECTRIC SMOKE DETECTOR 71-570000-001 70.02 10 ll 10 2 IONIZATION SMOKE DETECTOR 70-540000-001 70.01 11 4 2 WIRE DETECTOR BASE 70-501000-001 70.104 12 1 MANUAL PULL STATION 64-330001-001 71.55 13 1 ABORT STATION 64-678752-010 K-84-10 14 1 MAINTENANCE SWITCH GEMCOM GEMCOM 31'-0" SERVER ROOM SEQUENCE OF OPERATIONS 1 15 3 NS-24MCW-AR HORN/STROBE DEVICE HSR-A K-75-020 16 1 El-NI180-NOZZLE SERVER ROOM 45-194716-192 K-45-2150 I ) First Detector: A) Panel shows "Alarm" B) Horn sounds (slow pulse) 60 bpm. 17 2 WARNING SIGN 06-231866-760 K-45-9030 C) HVAC shutdown occur 2) Second Detector: A) Panel shows "Alarm" B) Horn sounds (fast pulse) 120 bpm. C) Panel starts 20 second delay ® � NOVEC CALCULATIONS B) Upon release, timer continues to count down to zero. 3) Abort Function: A) Upon activation. timer resets to initial value. HAZARD VOLUME CONCENTRATION MINIMUM AGENT ADJUSTED AGENT 14 I� SERVER ROOM 5.243.81 4.20 % 198.8 199.0 4) NOVEC Discharge: A) Horn sounds (steady) B) Strobe activates 16 5) Manual Release: A) Panel show "Alarm" Shutdown t f T. 9- E' C) Horn sounds (steady) NOVEC NO SUSIFLUDIR NovEc�P - NOVEC AEGIS CONTROL PANEL D) Strobe activates E) Overrides the delay functions ® - NOVEC MANUAL PULL causing the Immediate release ® - NOVEC ABORT STATION FLOOR PLAN VIEW of agent NOTES: (MECHANICAL) rtS - NOVEC MAINTENANCE SWITCH SCAM VC r- O_ 1 ) Pipe. fittings and installation as per N.F.P.A. #2001 (2012 Edition). - NOVEC ALARM HORN/STROBE 2) System design is based on doors closed. ventilation off. and the protected area well sealed to prevent leakage. O - IONIZATION SMOKE DETECTOR 3) Piping and nozzle calculations on separate sheets. © - PHOTOELECTRIC SMOKE DETECTOR 4) Pipe to be rigidly supported by U.L. listed hangers. Pay particular attention to bracing at nozzles. NOTE - PIPING OFFSETS FOR CLARITY ONLY 5) Piping must be run as shown. Any deviation from the arrangement shown, will require a complete review of the pipe and nozzle calculations. 0--- - NOZZLE & PIPING 6) Before assembling, pipe to be reamed and blown clear. Teflon tape to be applied to male treads only. 7) WARNING: Anti-recoil plug must be installed in valve outlet at all times except when connecting to system or when filling. Detector circuit 2 Do not attempt to remove cylinder from installation if anti-recoil plug and protection cap are not available for safe 0 H 1-I 0 handling of cylinder. r o a Abort Stotion Manual Release O S O S Entl-af-Line Resistar Err ;!-n ?.s Wr ,``-�z , NOTES: (ELECTRICAL) 5.ik+/-5%,0.5W 1•, ° 1•, 1.1 ° 1•, ELECTRIC CONTROL HEAD SEE CONTROL PANEL Endo(-Line Resistor DIAGRAM FOR WIRING I ) Power supply to be dedicated service. 120 VAC +/- 10%. 60 HZ. 5.1 k+1-5%,0.5 IN CYLINDER VALVE 2) Earth ground must be connected to cold water pipe. Make sure SAFETY CAP that water meter is properly bypassed. ® Detector Circuit 1 3) Install all wiring in accordance with local and national electrical codes. soen°cry suprnmy I O 1 zem aw ws.r o.mr r_ 4:1-0 Ft N 1-, Fire Alarm : x t t - , s r s Trouble Relay 6 % 0v1 _,3 -a mE 4) Be sure all wiring is free of shorts and grown foots before a O Sa O S PRESSURE applying power to control panel. GAUGE Fire Alarm 0-a 0 ;� O"""`•:` P P Y Programmable Relays O"��••" 5) Do OOt insert Or remOVe a Wlre Or anal COm Orient WITh On o,",:_,:,.0 g LIFTING Relay-Contact Rating 3 = o-• o•~�° 0.8'L x 1 1/4"D 1' power on the control panel. OA@30VDC(fresistive) re„� o — , o„;,,= o .a ,s E _ LUGS 3.0 A @ 120 VAb(reslshve) o O O - O "" 15 o" = o ° "" 5 6) Alarm and trouble contacts are rate at 2 Amps. -- S ° ° ° =: ° Q� (]O El-NI CYLINDER r r 0 0 0 0 1' 7) Mount batteries and relays. If an inside cabinet. 4 NAMEPLATE UNISTRUT 8) Observe all polarities and wiring details as shown. Batt ry Battery BRACING �` 9) No parallel branches or splice taps are permitted on ® ® 6.4' ALL PIPING IS 52.75" supervised lines. SCHEDULE 40 47.50" AC Supply Select Svntch BLACK IRON CYLINDER 10) Do not run s stem low voltage wiring in the some conduit rri (s6) ; CYLINDER with AC conductors. yt� Rego Auxiliary Output refs a Regulated 24 Vc STRAP White Current1.0(max.) '� s.e�, a.e.wz nu envx ones " + + Entlof-Line Resistor 1' 120 VAC,50/60 Hz,3.2 A Black i 5.1 k+1-5%,OS W i 6 3 2 or SB 240 VAC,50/60 Hz,1.6 A reen - is Orel° Horn/Stwite 12.75" To Earth-Ground Notification-Appliance Circuit stud an side of back box ISWITCAH CE 1 SERVER ROOM THIS INFORMATION IS THE DES. C. WHITE 200 LB. CYLINDER PROPERTY OF THE STUART THE STUART L. WHITE CO. Main-solenoid circuit [I)\10 W/199 LB. NOVEC 1230 L. WHITE CO. IT IS HEREBY 61k ENG. C. WHITE FIRE PROTECTION ENGINEERS Red SUBMITTED IN CONFIDENCE 543 BOSTON POST ROAD IMusleRGosein Deile,sPok ud22 0 0 23-001 AND NOT TO BE DISCLOSED DWG. K. FLYNN enclosure) OR UTILIZED WITHOUT MILFORD. CT. 06460 AEGIS WIRING DIAGRAM ISOMETRIC PIPING CYLINDER DETAIL - 200 LB. WRITTEN PERMISSION. CHK. E. KOZAK TICKET NETWORK ` , it T. NO SCALE , SCALE AS NOTED MFG. KIDDE-FENWAL 63 GERBER ROAD NO SCALEWaMCAI_ LICENSE - F3m ISSUED 01-30-2012 SOUTH WINDSOR. CT 06074 IZECncAL LicssE - w5546 AS BUILT 06-13-2012 KIDDE NOVEC 1230 FIRE PROTECTION RVS. SYSTEM FOR SERVER ROOM CD RAL70R MACX FIRE DWG.# 12-006 ENG.# SWN-21118 _ Ill