Loading...
HomeMy WebLinkAbout949 Pleasant Valley Road - Life Safety S (5) FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY INFORMATION Name of pro ert PL4L�SGi\ Vc. k1J (c�rYJ0min%,-.rr" --_LAY b Address: CiHq ArJ. Description of property: Occupancy type: Ra,.% A Name of property representative: mGnaG e m?, cn(Zi l�a r r,nY Address: Phone: Fax: E-mail: Authority having jurisdiction over this property; Phone: Fax: E-mail: 2. FIRE ALARM SYSTEM INSTALLATION,SERVICE,AND TESTING INFORMATION Installation contractor for this equipment: Address:_S6� C\c.c , {�c . 'Cc.5'v CT 0`3a3 Phone: 5((.Z- LA' q- asp Fax: E-mail: Service organization for this equipment: S;a.,?hc Gr: r\oua \t Address: "6� C\,,k Or r C.,s+ flse< l -N LZ- 06c»3 Phone: ck 6 0- Fax: E-mail: Location of as-built drawings: Location of historical test reports: Location of system operation and maintenance manuals: A contract for test and inspection in accordance with NFPA standards is in effect as of Contracted testing company: Address: Phone: Fax: E-mail: Contract expires: Contract number: Frequency of routine inspections: 3.TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: Name of organization receiving alarm signals with phone numbers (if applicable).: Alarm: S; _xly r,r.c�\\ �.� nC c a\ f�'1�„c 1 c; .d Phone: 7+-I[- 75 3 Supervisory: Phone: Trouble: S 1MC4 .x G s:PI(\k :e y"'k k C f Z) Phone:_';MK-7'16 -73 3 ci Entity to which alarms are retransmitted: 5 r Q Phone: Method of retransmission of alarms to that organization or location: Reprinted with permission from NFPA 72,National Fire Alarm-0ode®,Copyright©2002,National Fire Protection Association,Quincy,MA 02169.This reprinted material is not the complete and official-position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. 2007 National Fire Protection Association SG24-2-014 Rev.(10l07)(p.1 of 5) NATIONAL FIRE ALARM CODE 3.TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued) If Chapter 8,note the means of transmission from the protected premises to the central station: Digital alarm communicator ❑McCulloh ❑Multiplex ❑ 2-way radio ❑ 1-way radio ❑N/A If Chapter 9,note the type of connection: ❑Local energy ❑Shunt ❑N/A 3.1 System Software Operating system(executive) software revision level: 41.-3. 3 Site-specific software revision date: all 3I f a. Revision completed by: s. To r r r 4.SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this system(see NFPA 72, Table 6.6.1): Quantity: a Style: Class: to 5.ALARM-INITIATING DEVICES AND CIRCUITS Characteristics of initiating device circuits connected to this system(see NFPA 72, Table 6.5): Quantity: < Y e Style: Class:' L3 5.1 Manual initiating devices 5.1.1 Manual Pull Stations Number of manual pull stations: Type of devices: ❑Addressable V Conventional LI Coded ❑Transmitter ❑N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: Type of coverage: ❑Complete area 10 Partial area ❑Nonrequired partial area ❑N/A Type of devices: ❑Addressable In Conventional ❑Coded ❑Transmitter ❑N/A Type of smoke detector sensing technology: ❑Ionization ❑Photoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: N A Type of coverage: Type of devices: ❑Addressable ❑Conventional ❑ Coded ❑Transmitter 'Q N/A Type of smoke detector sensing technology: ❑Ionization ❑Photoelectric 5.2.3 Heat Detectors Number of heat detectors: Type of coverage: ❑Complete area ❑Partial area ❑Nonrequired partial area L11 N/A Type of devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter W N/A 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: Type of devices: ❑Addressable M Conventional ❑Coded ❑Transmitter ❑N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: Alarm verification on this system is: ❑Enabled K1 Disabled ❑Set for seconds Reprinted with permission from NFPA 72,National Fire Alarm Code@,Copyright 02002,National Fire Protection Association,Quincy,MA 02169.This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. ©2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.2 of 5) FUNDAMENTALS OF FIRE ALARM SYSTEMS 6..$UPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of valve supervisory switches: Type of devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter N/A 6.2 Fire Pump Type of fire pump: ❑Electrical ❑Diesel Type of pump supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter O N/A Fire Pump Functions Supervised ❑Fire pump power ❑Fire pump running ❑Fire pump phase reversal ❑Selector switch not in auto ❑Engine or cotrol panel trouble ❑Low fuel Other: 6.3 Engine-Driven Generator Type of generator supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter IQ N/A ❑Engine or control panel trouble. ❑Generator running 0 Selector switch not in auto ❑Low fuel Other: I 7.ANNUNCIATORS I 7.1 Annunciator 1 id Local ❑Remote Type: ❑Addressable ❑Directory ❑Graphic ❑N/A Location: L/_P Rrm. FRCP 7.2 Annunciator 2 ❑Local ❑Remote Type: ❑Addressable ❑Directory ❑Graphic ❑N/A Location: 7:3 Annunciator 3 ❑Local ❑Remote Type: ❑Addressable ❑Directory 0 Graphic ❑N/A Location: 8.ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker zones: 8.2 Telephone Jacks Number of telephone jacks installed: Number of telephone handsets stored on site: Type of telephone system installed: ❑Electrically powered ❑ Sound powered ❑N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system(see NFPA 72, Table 6.5): Quantity: Style: Class: Reprinted with permission from NFPA 72,National Fire Alarm Code®,Copyright©2002,National Fire Protection Association,Quincy,MA 02169.This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. 0 2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.3 of 5) I NATIONAL FIRE ALARM CODE 8.ALARM NOTIFICATION DEVICES AND CIRCUITS (continued) 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device Horns: With visual device: Chimes: With visual device Bells: With visual device: Visual devices without audible devices: Other(describe): 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED ❑Hold-open door releasing devices ❑ Smoke management or smoke control ❑Door unlocking ❑Elevator recall ❑Other 0. SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage ICI yAc Amps Overcurrent protection: Type Amps Location(of primary supply panelboard): t_L P ern. Disconnecting means location: 10.2 Secondary Power Location: �A(-P Type:i-j1 cJ e r) Nominal voltage: Iy A)L Current rating: Number of standby batteries: .1 Amp hour rating: I a A H Location of emergency generator: Location of fuel storage: Calculated capacity of secondary power to drive the system 4 f, In standby mode: In alarm mode: 1. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) 4kNFPA 72 ❑NFPA 70,National Electrical Code, Article 760 IV Manufacturer's published instructions ❑Other(please specify): System deviations from referenced NFPA standards: Signed: ��-- Printed name: _fie ;R \ �,..� Date: a1JL La_ Organization: Title: T ,11,r Phone: Srgo-H 3X-31Oo 2. RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below,on the date shown below, and were found to be operating properly in accordance with the requirements of: dW NFPA 72 ❑NFPA 70,National Electrical Code, Article 760 54 Manufacturer's published instructions ❑ Other(please specify): ❑Documentation,in accordan ce ection and Testing Form(Figure 10.6.2.3)is attached Signed: 1 Zpw Printed name: S Pl c Date: ;015Ll Organization: S; + ��, try:sell Title: Phone: Reprinted with permission from NFRA 72,National Fire Alarm Code®,Copyright 02002,National Fire Pr tection Association,Quincy,MA 02169.This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. ©2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.4 of 5) FUNDAMENTALS OF FIR�ARM SYSTEMS 3.CERTIFICATIONS AND APPROVALS 13.1 System Installation Contractor. This system as-specified herein has been installed and tested according to all NFPA standards cited herein. Signed' Printed name: ,1 <5 1 r�mac[ _ Date: I � Organization: Title: Phone: 5f6 0-H15%-31.co.> 13.2 System Service Contractor This system as specified herein has been installed and tested accordingto all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.3 Central Station Thinsystem as.specified herein will be monitored according.to all_NFPA.standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.4 Property Representative I-accept this system as having been installed and tested to ifs--specifications and all NFPA standards cited herein. Signed: . _ Printed name: Date: Organization: Title: Phone: 1:3.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in-accordance with its approved plans and specifications,its approved sequence of operations, and with all NFPA standards cited 2erein. Signed: Printed name: Date: Organization: av//! �/•� r� IeiJ'�V Title: /71-s14 / Phone: Reprinted-with permission from NFPA 72,.National Fire Alarm Code@,Copyright d2002;--National Fire.Protection Association,Quincy,MA 02169.This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by standard in its entirety. 0 2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.5 of 5)