FIRE ALARM SYSTEM RECORD OF COMPLETION
To be completed by.the system installation contractor at the time of system acceptance and approval.
1. PROTECTED PROPERTY INFORMATION
Name of property: PI 2 n 5 rJ!\2'T yc.1 I�e v C'n ri o m e n il to Q
Address: !9q 9 el!C4LGOT v Ra -Sn,,tk yJ,nds c- l T,
Description of property:
Occupancy type: c s: A,,A: \
Name of property representative: A c c 'e c� ma a��e m4 n+ G o J, c_� Or rri C\
Address:
Phone: (e n- (oH 9y a7 Fax: E-mail:
Authority having jurisdiction over this property:
Phone: Fax: E-mail:
2. FIRE ALARM SYSTEM INSTALLATION,SERVICE,AND TESTING INFORMATION
Installation contractor for this equipment: 5�m I2x
Address: %0k c l a.c l< O c-: .n. 66.sf �O L O' i
Phone: Fax: E-mail:
Service organization for this equipment:
Address:
Phone: Fax: E-mail:
Location of as-built drawings: Location of historical test reports:
Location of system operation and maintenance manuals:
A contract for test and inspection in accordance with NFPA standards is in effect as of
Contracted testing company:
Address:
Phone: Fax: E-mail:
Contract expires: Contract number: Frequency of routine inspections:
3.TYPE OF FIRE ALARM SYSTEM OR SERVICE
NFPA 72 Chapter Reference of System Type: W P
Name of organization receiving alarm signals with phone numbers(if applicable):
Alarm: 5,c�, �_x�s n a_„ ( e .� �.` (�"10 Fo{ Phone: 9S fS- 7 H G-753 9
Supervisory: Phone:
Trouble: S_ m?Loy 6y C: r\,-"a_„ Lg.may t I rn.:,,k o� Phone: T q 9 - 7"/6 '7 5 3 q
Entity to which alarms are retransmitted: Phone:
Method of retransmission of alarms to that organization or location:
Reprinted with permission from NFPA 72,National Fire Alarm Code@,Copyright 02002,National Fire Protection Association,Quincy,MA 02169.This reprinted material is
not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety.
0 2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.1 of 5)
NATIONAL FIRE ALARM CODE
3.TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued)
If Chapter 8,note the means of transmission from the protected premises to the central station:
❑ Digital alarm communicator ❑McCulloh ❑Multiplex ❑2-way radio ❑ 1-way radio ❑NIA
If Chapter 9,note the type of connection: ❑Local energy ❑ Shunt ❑N/A
3.1 System Software
Operating system(executive) software revision level: J 3_3 (14 n y. E-A/P
Site-specific software revision date: Q JA 311-4 Revision completed by: r T; „
4.SIGNALING LINE CIRCUITS
Characteristics of signaling line circuits connected to this system(see NFPA 72,Table 6.6.1):
Quantity: Style: Class: ` 8
5.ALARM-INITIATING DEVICES AND CIRCUITS
Characteristics of initiating device circuits connected to this system(see NFPA 72, Table 6.5):
Quantity: Style: Class: (�
5.1 Manual initiating devices
5.1.1 Manual Pull Stations Number of manual pull stations:
Type of devices: ❑Addressable IN Conventional ❑Coded ❑Transmitter ❑N/A
5.2 Automatic Initiating Devices
5.2.1 Area Smoke Detectors Number of smoke detectors: 9
Type of coverage: ❑Complete area W Partial area ❑Nonrequired partial area ❑N/A
Type of devices: ❑Addressable [�Conventional ❑Coded ❑Transmitter ❑N/A
Type of smoke detector sensing technology: ❑Ionization ❑Photoelectric
5.2.2 Duct Smoke Detectors Number of duct smoke detectors:
Type of coverage:
Type of devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter ❑N/A
Type of smoke detector sensing technology: ❑Ionization ❑Photoelectric
5.2.3 Heat Detectors Number of heat detectors: / 3
Type.of coverage: 0 Complete area 14 Partial area ❑Nonrequired partial area ❑N/A
Type of devices: ❑Addressable 5/d Conventional ❑Coded ❑Transmitter ❑N/A
5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: NIA
Type of devices: ❑Addressable ❑Conventional ❑ Coded ❑Transmitter Zt N/A
5.2.5 Alarm Verification Number of devices subject to alarm verification:
Alarm verification on this system is: ❑Enabled 14 Disabled ❑Set for seconds
Reprinted with permission from NFPA 72,National Fire Alarm Code@;Copyright 02002,National Fire Protection Association,Quincy,MA 02169.This reprinted material is
not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only.by the standard in its entirety.
0 2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.2 of 5)
FUNDAMENTALS OF FIRE ALARM SYSTEMS
}
6. SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUITS
6.1 Sprinkler System Number of valve supervisory switches:
Type of devices: ❑Addressable ❑Conventional ❑ Coded ❑Transmitter lP N/A
6.2 Fire Pump
Type of fire pump: ❑Electrical ❑Diesel
Type of pump supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter JI N/A
Fire Pump Functions Supervised
❑Fire pump power ❑Fire pump running ❑Fire pump phase reversal ❑ Selector switch not in auto
❑Engine or control panel trouble ❑Low fuel
Other:
6.3 Engine-Driven Generator
Type of generator supervisory devices: ❑Addressable ❑Conventional ❑Coded ❑Transmitter IQ N/A
❑Engine or control panel trouble ❑Generator running ❑Selector switch not in auto ❑Low fuel
Other:
7.ANNUNCIATORS
7.1 Annunciator 1 U Local ❑Remote
Type: ❑Addressable ❑Directory ❑Graphic ❑N/A Location: LL P Ml,P
7.2 Annunciator 2 ❑Local ❑Remote
Type: ❑Addressable ❑Directory ❑.Graphic ❑N/A Location:
7.3 Annunciator 3 ❑Local ❑Remote
Type: ❑Addressable ❑Directory ❑Graphic ❑N/A Location:
8. ALARM NOTIFICATION DEVICES AND CIRCUITS
8.1 Emergency Voice Alarm Service
Number of single voice alarm channels: Number of multiple voice alarm channels:
Number of speakers: Number of speaker zones:
8.2 Telephone Jacks
Number of telephone jacks installed: Number of telephone handsets stored on site:
Type of telephone system installed: ❑Electrically powered ❑ Sound powered ❑N/A
8.3 Nonvoice Audible System
Characteristics of notification device circuits connected to this system(see NFPA 72, Table 6.5):
Quantity Style: Class:
Reprinted with permission from NFPA 72,•National fire Alarm Code@,Copyright 02002,National Fire Protection Association,Quincy,MA 02169.This reprinted material is
not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety.
0 2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.3 of5)
NATIONAL FIRE ALARM CODE
8. ALARM NOTIFICATION DEVICES AND CIRCUITS (continued)
8.4 Types and Quantities of Nonvoice Notification Appliances Installed
Bells: With visual device Horns: i T With visual device: y
Chimes: With visual device Bells:. With visual device:
Visual devices without audible devices: Other(describe):
t 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED
❑Hold-open door releasing devices ❑Smoke management or smoke control
❑Door unlocking ❑Elevator recall ❑ Other
0. SYSTEM POWER SUPPLY
10.1 Primary Power
Nominal voltage a a VAC. Amps
Overcurrent protection: Type Amps
Location(of primary supply panelboard): Cj P Q m.
Disconnecting means location:
10.2 Secondary Power
Location: C 0 Type: F2��fl e-rP_rly Nominal voltage: aH Currentrating:
Number of standby batteries: 1 Amp hour rating: t a AN
Location of emergency generator:
Location of fuel storage:
Calculated capacity of secondary power to drive the system
In standby mode: In alarm mode:
1. RECORD OF SYSTEM INSTALLATION
Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper
branching, but before conducting operational acceptance tests.
The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.)
ULNFPA 72 ❑NFPA.70,National Electrical Code, Article 760
CkManufacturer's published instructions ❑Other(please specify):
System deviations from referenced NFPA standards:
Signed: Printed name: Date: 2-11%�b 1
Organization: Title: 11*-r Phone: gbh-Ai 3k-i•u•C
2. RECORD OF SYSTEM OPERATION
All operational features and functions of this system were tested by or in the presence of the signer shown below,on
the date shown below, and were found to be operating properly in accordance with the requirements of:
NFPA 72 ❑NFPA 70,National Electrical Code, Article 760
} Manufacturer's published instructions ❑Other(please specify):
❑Documentation in accordance with Inspection and Testing Form(Figure 10.6.2.3)is attached
Signed. U'" Printed name: Sex.n J,c c y Date:��1"Al b a-
Organization: S, ^v,; (gxGr 4"'rla.l j Title: 7Lenk Ra,3 Phone: T&0 N3k-3aM
Reprinted with permission from NFPA 72,National Fire Alarm Code%Copyright 02002,National Fire Pr ection Association,Quincy,MA 02169.This reprinted material is
not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety.
2007 National Fire Protection Association SG24-2-014 Rev.(10/07)(p.4 of 5)
FUNDAMENTALS OF FIRE ALARM SYSTEMS
A
3.CERTIFICATIONSAND-APPROVALS
,13.1 System Installation Contractor.
- This system as specified herein has been installed and tested according to aWN17PA standards cited herein.
Signed: Printed name: 4�P �s Date: A/I's/f a
Organization: S�. Q x���,�,c� \\ Title: Y-U_._T Phone: Ir,,0-4 3 g-
13.2.System Service Contractor
This system as 'specified herein has been installed and;tested according to all NFPA standards cited herein.
Signed: Printed name: Date:
Organization: Title: Phone:
13.3 Central Station
This system as specified herein will be monitored according to all NFPA standards cited herein.
Signed: Printed name: Date:
Organization: Title: Phone:
.13A Property Representative
I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein.
Signed: Printed name: Date:
Organization: Title: Phone:
13.5 Authority.-Having Jurisdiction
I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly
in accordance with its approved plans and specifications,its approved sequence of operations,and with all NFPA
standards ci d le-
Printed name: Date: I-A-
Organization: Title: F✓.-VOW6 L-L ( Phone:
f
Reprinted with permission from NFPA 72,National Fire Alarm Code@,copyright 02002,National Fire Protection Association,Quincy,MA 02169.This reprinted.material is
riot the complete and official.position of the National Fire Protection Association on the referenced.subject which-is represented only by the:standard in its entirety.'
0 2007 National Fire Protection Association- SG2472-014 Rev.(10/07.)•(p.5 of 5) ,_