Loading...
HomeMy WebLinkAbout75 Evergreen Way - Building Plans &amp; Draw (3) PROJECT DIRECTORY L.L. BEAN REQUIRED VENDORS Owner Fire Alarm System, Security Cameras and Be n® ® L.L. Bean Intrusion Alarm System 15 Casco Street HSM Electronic Protection Services Freeport, Maine 04023 300 Bear Hill Road Contact: J.D. Schnackenberg Waltham, MA 02451 T: (207) 522-7907 Contact: Rick Weiss, CPP \A/ F: (207) 522-7773 T: (781) 487-0330 F: (781) 890-2780 Arch ect Lighting Supplier The Shops at Ever reen alk Bergmeyer Architectural PC TBD 9 51 Sleeper Street Boston, MA 02210 ■ David Tubridy, Principal in Charge Project Coordinator: Lewis Mulfelder Contact: Rachel Zsembery, Project Manager T: 617.542.1025 F: 617.542.1026 South W i. ndsor , CT Owner's Project Manager Exterior Signs TBD North American Sign Company 3601 West Lathrop Rd South Bend, IN 46624 Contact: Dick Copeland T: (800) 348-5000 F: (574) 234-0019 Land Developer Storage Systems Poag & McEwen Lifestyle Centers Pipp Mobile Storage Systems 6410 Poplar Avenue, Suite 850 2966 Wilson Dr NW Memphis, TN 38119 Walkes, MI 49544 Contact: Scott Kern Contact: John Ritter T: (901) 761-7604 T: (616) 988-4074 F: (901) 761-5325 F: (616) 791-9916 t r M/E/P/ Engineer � $ �-,� ��ti r ��.�, N Henderson Engineering �' 7330 North 16th Street Suite A110 Phoenix, AZ 85020 Contact: Omid Mottahed t T: (602) 957-3050 ,� � . F: (602) 957 3012 LANDLORD REQUIRED VENDORS Structural Engineer Fire Protection Odeh Engineering, Inc Professional Electric Contractors of CT 1223 Mineral Spring Avenue 100 Access Rd North Providence, RI 02904 Norwood, MA 02062 Contact: David J. Odeh Contact: Gerry Malloy T: (401) 724-1771 T: (781) 769-7767 F: (4010 724-1981 gjmalloy@snet.net Commissioning Engineer Roofing Synergy Consultants, Inc. R &S Construction Services, Inc. 54 Front St., Suite #7 2072 Straits Turnpike Fall River, MA 02721 P.O. Box 121 Contact: Jim Fikiet Middlebury, CT 06762 T: (508) 646-3663 T: (203) 758-8500 F: F: (203) 758-8440 Lighting Designer LAM Partners, Inc. 84 Sherman Street LV Cambridge, MA 02140 Contact: Dan Weissman } T: (617) 354-4502 F: (617) 497-5038 Fixture Contractor Utopia Designs, Inc. P.O. Box 1966 Biddeford, ME 04005 LJ Contact: John Thibeault T: (207) 282-8474 1 F: (207) 282-8475 Specifications Consultant Kalin Associates, Inc. of coNNF 1121 Washington Street �����Pp°HTF0T%G Newton, MA 02465 Contact: Lisa Goodwin Robbins �J T: (617) 964-5477 l o i1 W i F: (617) 964-5788 D • „ v5 D \ : 1 V 9 r Ac` Bergmeyer Project Number: 06125.00 CONSTRUCTION DOCUMENTS ISSUE FOR BID / PERMIT : FEBRUARY 9 , 2007 _ Architecture and Interiors Bergtneyer Architectural P.C. 51 Sleeper Street Boston,NLA 02210 Phone 617 542 1025 Fax 617 5421026 www.Uergtneyer.com @ Copyright 2007 Bergmeyer Associates, Inc. i I -- -- - ------ — -- — ------ -------- -- --------------- vu•nl!jeooj aseQ gZ�\jospu!M tpnosm 03f02!d`llA3as0 Jil 0N3J31108WAS lb01bUO313 40£3 831n03HOS 13Nbd WMI10313 £0Z3 S3lna31-10S l3Nbd IbOINiO313 Z0Z3 213ddOO a3UbO0 0b31 001 2101�131XM UXM 030Nb H-ld3l Hl 03SOdX3 dX3 A2ibWWnS abOl 'SNOIIbin0lb01lnbd 'Wb2IJbl0 3NIl 3N01b 01�1U0313 40Z3 0 0 UN011binSNI ONnOS SNI (INS Nbld lOOd 2ib3Nli di ISnbHX3 HX3 W31SASblba l3131 5043 zM111VIS WIS Nb SONnOd sal JNIISIX3ISIX3 ld 1N3Wd1n03 JNIBWnid/O bnH ibOWiO313 b043 133HS 1HS ANOlbnbl nbl b31000 �:131bM 01�110313 0M3 NV]d JNIIH011 IVONIOM313AM 2:OMO1 _E04 (133d) lOOd 321bn0S dg 3 31b'NIWbi WVi 1N3Wdin03 din03 N01103S t03S 00'SZ490 :ON q°r ' Nbld JNI1HJIl lb0121103i3 i3n31 ?�3ddn Z043 NOVbJl1HJ11 In ibn03 032)0103t30 3>IOWS 0g (HiON3l) JNOi Nbld l A0N3%J3W3a3W3 �a�oay0 .�9 Pa>Ioe40 i I3MOd 1b01�i10313 4043 Q C�d023d}JI2iaM Ibi�n1 n211S ON.SL3i�31 L 'S301n�13S 3WO OIIOS OS 31b1dNOIN id71 2�Olbn3l3 n313 01Sb8 SMJOiQNbI 3H1 WOW 031newisia SW3ISAS iVMJ-L0D13 0Nb JNIBWnId 'NOUO0 I tld 32i1d 'W31SAS a3ab312131bM NIb2I lM2i 2IOliNbr Nbr NOIlbn313 i3 ObnH M3N b 38111M 383H1 -S3L1n1Xld 3S10Nb'H0 J3W 0Nb S3HSINId aNb SN0111-f-Wd W1831N1 'S1N0WERJOIS a00M09H 0M?! �lORi3UNi 1Ni S31n03H0S IbOINHH03W 40£W 80183IX3 M3N JNIaniONJ -831N30 31A1S-3d11 M3N b NI UNbN3i 1ib13b b i80d dn-lld 2101831Nl 1b10�13WWOO JNIN3dO HJn0a 0� lb0RI10313 0313 N011binSNl lnSNl 1NIOr NOISNbdX3 r3 Sllbl3a IbOINtJH03W 40ZW ANiNumS 103r0ud WOOd Wa o3aniONl IONI WMISAS HSINW V NOI1binSNl 8OPd31X3 SdIM Nbld 1b01NbHO3W 13n312iMMOl Z04W aNdH iHJRI Hsi HONI NI H0b3 b3 133HS 31111 Nbld iVOINVH03W 13n3183ddn 404W 4 03ZJ 3NON : 4'Z06Z 318b1 NOISIn38 AM2I JNIMb2ia JMQ 2I3MOHS 2i313Wb1a 301SNI 01 4 ' 4 4'Z06Z 318b1 NNIS 3OIn�13S 1NMIliS32I 11S32i 8Oi0Vd1N00 i dE]N3J A8 0311b1SNl 0081 JNIN3d0 NOOa JNdO Zia bL09010 `�ospulM y}nog MOTIH 4 : 0001, 4 4'Z06Z 318b1 NlbtNnod JNI>1NI�10 30N3N3JM d32i 2I31bM lOH MH 2300a �a 5L a�ing `0 6u1p1lne S2i3S1�1 8 SiIb130 'S31naMH0S JNIBWnId 40Zd X38INn I/WZ/dZ W 05Ll4 8 d 05U4 4'Z06Z 318b1 AUOlbnb-I amnn032i003U JNI1000 '8 NOIlbillN3n 'JNI1b3H OVAH 2i3SN3dSl0 dS10 anb NoeJewei 5L lGSIN V Nbld -8601d JNIBWnId a39?]VIN3 Z04d X3SINn 1/lbNwn 4/WZ '8 d£ : W 009/4 '8 d 009/4 : 4'Z06Z 318b1 13S010 2I31bM 30N3�i3d32I SS02I0 d3bX 03SS3O3a 0Mi 1HJI3H iH NOISN3WI0 Wla NIeM U9aJ6Ian3 le sdoyS aqi I Nbld �IOOid JNIBWnid 404d (SA 3AOldW3 OZ S311111Obd JNIBWnId 1NiOd `>NI>1�IOM d Snl0b2i 0b�i iVINOZ18OHMOH M H3SRI d 3INVHA 1b13W MOiiOH dWH b31MW`dla Via b31b3H 83UVM HM 311i U:NVn0 10 ib1MW MO1lOH WH i1b13a 130 O SSblO 5'E08 318b1 NOIUbOIdISSbiO HSINid 0188bd llbM evim NOIII18Vd Ntd S332IJ30 030 Nbld b3l>1NI2�dS NOIlO3lObd 3�IId 404dd 3NON : 0M2i OMA 3NON : 4'9401. 318b1 : 800R)b00 SS30Ob11X3 3JNbld 301M dM McJVMGUVH 8M0H 2i31N30 �IlO dr3�w N011112Ibd 3>IOWS NOIUII21bd 3>IOWS 4'1, 4'Z0£ 103S : NO1I U2ibd S31VS /W002i>10OIS OOOM 0M a31b32I13i inSSMId Id a00M(18VH 0M0H 311101Wbi83O lO 1NIOd Id bOOa DOOM M2i00 MO1lOH OMOH SWb38 WOOb JNillid '8 W2IOdlbld 21b3NllOOd - S31bNd311b 00b E08b tQQH 4 OMI 3NON : Z'£'ZO8 318b1 Sllt/M JNISIW301Nb N31 13SO10 2i31bM 0M >INnS�131NnO0 >i10 \ J 2IOH0NbllbM bpl� UNIbd id 3803MOiiOH OH i3dWO 1dO jc SV0JOdlbld - S11V13a NOIi0nb1SNOO Z08b SNOIlb2Ibd3S 3n11SIS3U 3�IId al'o'd ZId a3ddb01aNb'H 0/H SnonNI1N001NOO b321b dOHS 3>118 - Sl1b130 NOIlOn2IUSNO0 408b NI 0£4 = 459 X Z'0 1nOH11M O/M a00MAld aMAld WnSdAJ dAJ HAM /M 31b1d 1ld 02Ib08libM WnSdAJ 8MJ NOIU0n2I1SN00 211SN00 Slibl3a NOIliSNb2i1 aNb aN3J3l HSINid £09b NI 94Z 000/NI Z'O 4'S004 318b1 HiaiM SS3�IJM 2131Sb Id 2i33N3n do onUISNO0 ONOO Sllb'130 0Nb 31n03HOS 3UVM021bH 0Nb 2)OOa Z09b id bL =id ZZZ X £/4 JNIBWnid J81d 0131d NI AdlaMn din 31VNIWbi 011Sb1d Wbld 3ab21J �J NWn1o0 100 ld rLG4 1bNOJblO XbW £/4 4'Z'b404103S : NOIIV'dVd3S i1X3 NM 1b011�i3n 12IMn JNIZbiJ Jo SSbiJ iJ JNIN3d0 03SV0 00 Sl1bl3a N011il�lbd 409b ld ,ZZ4 ; tMMd 05Z 311SOddO ddO WnSdAJ 030UOdN1MJ 8381d SSbiJ J�1dJ 4'S404 318b1 Hlbd SS3aJ3 XVW Mlil NOI11SOdWOO lANln IOn 03i1VISNPR 03HSIN2Ind U3NM0 Id0 313�10N00 a3ObOdNl3�i 21M81d-SSbIJ O�IdJ b31Nn002IIN0 j Sllbl3a 2IOIN3INI 605b £ 4'8404 318b1 S11X3 d0 H38WnN amjin03�1 a310N 3SIM�13H10 SSM1Nn NOn 03llbISNI �13NM0/aMHSIN2ind �IMNMO 10/d0 IINn A�INOSt/W 313210NO0 nW0 SWIM NWMll1W L05b SSMbJ3 3SIM213H10 0310N SSMiNn ONn 11b1SNl tIOlOb2iINO0/aMHSINand tI3NM0 10/d0 ?3010ba1N001bi83NMJ OJ 311SOdWO0 1SdWO b32Ib 968 JNId331S/ S00 - Siibl3a Xi 10MllIW L05t1 Un0?j30Nn On 8313INVIG 3a1Sin0 00 OMZINInIbJ nlbJ �Ib310 810 Sl1b130 NOb2I AbldSIG NVAb>1 905b ` " = 1b101 ObOI 1Nbdn0001b101 ib0IdA1 dAl 3JbJ bJ 1HJI3H J _ 831N30 N NI1130 1`JH 01O L 4 = 00£/6505 : dS 0.0£LOO� 4 ^)IJOl '_ 0 O O U3SN3dS10 83dbd 131101 Odl lIV83AO b0 JNliOO=l J2Ind JNI1130 010 ., ,t ilb'M�l`dAb>i Sllt/i3a X230MilIW 505b bE9 0£/Z4054 • dSO£/O�bS3lt/.S�� : Z'4'b004 3i8b'1 : 30NbMOlibb3�ib' 21001d JNIlOOd Jld 3NIl b31N30 l0 Slib130 aNb SNbld SNOIlbn313 iibM W3J b05b S:6f 9;a� llbM d0 d01 Mol 31b0S Ol ION SIN bMbb 2)OOid SS02IJ 1331S d0 dOI Sol (U3Md) lOOd ld 1Nior IMUNO0 r0 lbNiWON WON DOOM 031b3�Ii 1Nb0�Jbi32i Mald NI12id JNIHSbId 2131Nn00 JIdO ` UeeB '1"1 S1ibM dV30 - Si1b130 MOMi11W E05b (]Vol 1Nbdn000 BbiS d0 d0l. SOl 1HJI1 ANON IN Sllbl3a N1 10Mii1H Z05b ' anlS do 30bd sod aogduaseo a{e0 �e oN "'3A AUNOSVW d0 dol WOi i3Vi IINOO NI lON 01N ONINV38 `EM13 ------- 9*Z'£06103S : CIM31ANIHdS AHNOSbW d0 30bd WOd oiaaod3nsSl Lo6oZo nN Sllbl3011210Mi11W 405b 1SIOrd0d01 rOU -f"nibN iVN Wb38 W8 (JNlalln8) SMIaO1S d0 'ON 31MON00 d0 dOl 001 HSINid d0 30bd 0Od Jfta-fi i8 EMS Sllbl30 3JbNJIS bOI2I31X3 50bb Ti 1 - Z'Z091O3S : MdAU NOIlOn2iiSN00 Wb38 d0 d01 80U HU�JON N 3U32i0NOO d0 30bd OOd JNi0lin8 J018 60C 103S : dn0uE) 3Sn 010HS3ZcIH1 ?�Hi lbl3W 11W NOIlbaNnOd N103 SnONIWnilB Wn118 Sllbl3a eII83A MiV 031NnOW 01W ONI1HJIl 1N30S3wnld wnid Sl1b130 31n8►1S3n EObb 1ba3N3J SS3NN01H1 Mi NISV8 30ARtl3S dOW 8SW 08VO9 08 3nOObJ '8 MnJN01 JSl WOid �Ild iN3WlbM21I 11bM 1b011Snoob 1Mb Sllbl3a 31n811S3n ZObb O3SOdO'Jd 1N3W32�inb32/ 30N-98333cV-000 NOUdIdDS30 JNIN3dO AMOSVW OW M in1Xid IXId wdn10311H0W H02ib ab32iU 1 sn03Nb1130SIW OSIW HSINU Nid S OU0 31n811S3n 40bb W3lSAS SAS WnWINIW NIW NOI1bn3lM 2)OOId HSINid 13 dd 31VWIXO 1ddV XO:Iddb SNOIlO3S JNlalln8 40Eb EOOZ 0031 AJ113N3 lANln 1MMHS AS �13bn10bn[ Nb'W 2idW WnNiWnlb Wnib 3000 MZ11d 3tb1S l0 90OZ : NOI103IMM Maid 3111 133HS OAS 30bd HSINid dd llNn JNIiONbH UV nHb db2iMHSbO Z4Zb 90OZ 03N 30001b012ilOMl3 MNINbZZ3W ZZ3W 13NI8b0 i83HSn0N11X3 32iid 03d 318biSnrab rab SNOI-LVAB13 0Nb SNbld 030iJViN3 - SNyn13W dOHS 3>118 4 4Zb 1NMWMlddnS 31b1S 10 500Z HIM £OOZ 0WI 30001b01NbH03W NIVIS NIS iVOINVH03WHO31N 213HSnE)NI1X3 M 11=1 3d 8001d HSINId 3n08b ddb iNMW3lddnS 31biS t0 500Z HIM EOOZ 0dl 3000 IbOINb HO3W 30 I JN18Wnld 1331S i1S Abla3AO AI1SN30 Wn103W OaW Nlbi_IO NOOld 0d 10b S311111OVSIG /M S,NVON31NV bab j SNOIlbn3l3 02ib0NblS aUS ANbJOHbW JOHt/W 2iol0bi81NOO M21n1X1d 0d aNb SNbld a3J2IblN3 - W21 JNIWWb2IJONOW '8 'W21 llln 'SWa1S321 04Zb £OOZ 4'L 4 4 ISNb/ 0OI 3aoo A IMISS300b 133iS SSM1NIb1S 1SS 3111 JNI11301b011Sn00b lOb (011N00) Sllbl3a '8 SNOIlbn3l3 - 3SnOH d0>lObB 60Zb 1N3W3lddnS MlbUS i0 500Z HUIM £OOZ O81 3000 JNlailn8 WnWiXbW XbW S2GH10 A8 03HSINi jnd 08d 3n08b 1A8V M21bn0S 0S lbRiMtbW ibW Wbblb 3bld bd SNOIlbn313 - 3SnOH d0>lObB 80Zb S3000 3i8b01lddb NOI1bOId103dS O3dS :>NIN01110N00 �Ilb 0/b W002I NOOIS LOW IV @n SNOIibn3l3 0Nb Nbld a3J21t/lN3 - WOO?d JNlllld S,N3W 90Zb A2lb�WWf1S 3Q0O SNOIlbn313 aNb Nbld 03J2IblN3 - SWOO�1 JNlllid SKMOM 50Zb 1SI1 N0IlbU\32188d SNOUVAD-13 2JON31N1 bOZb SN011bn313 2JOW31N1 £OZb �h{ � r - x ' SN011bn313 2JON3UN1 ZOZb � , :, t a= ,� 1 � k rr . s�l�' �° �f ` &s t , .: 'k tU.-' n �`,.�^,• �s�v' d >Y{y; SNOIlbn3l3 ZIOIZI31X3 40Zb ! ~; � - ' ' a ry,��� � _ t sk rl ORIJ NWnl00 sslt Mom^' U F :NG�`Gi3J6^ � ..'= 4t ."F rSr <- e ';i,� .. inoAbl SaabONbiS '8 Nbid M inixu 504b ' d ' '. �r '� a" m i n ti r ' '}" s ur4' � �. - - - - Nbld ' a~ HSINId bOlb s ,P•,. :3, ,' .s' Nbld UN3Wdin03 '8 301n30 £04b �J ,. 138VI W0o21 3WVN W00N �,' �c �,-�;:- i�.�^it"�d°r-st•E��vt ' ' ��','_y r l ,,;.ra,r.wj\�,: Nbld SN11130 MU031d3Z1 ZOIb ! ` w �a LSw '' r' r�'r,'. " bz+.�+�-raT# tii ` }fir r E f',-�.ni }t�� • Y j„ NYid NOItomu SNOO 404b 4 5p yr m e, r . 4 u NOIlbn3lM rr•� r. >arrt _ <, 1¢ +n-�a s <., lld 1HS wunio3iwouV - 3�S'. SN01103SNOI-LVNU :, 6 6 h dNOO 3Sb31 b00J .. , ,` A t , „s.. > r ,- N. Kam? N s,,, 5 p ka;: ,a • ,... <, s �i�A,,, .f Mn1X)d / 3�In11N2ind NVId yv hl,2r_} ,4r..- -. ` ..'t�i 1 ti -=':`• ? Y tii '.Fa7.l•t _ TxhY(` -.`yilA lbW2IIdNOO 3Sb31 EOOJ rr , r. . 3a3f 4 7 a ,t,. t ,: } , k & N."' ,;yd,}n. 3x'?r } • r�• .. z - v'S` va„ f�-, ", G'1rMaF I ,,:.• :, .. e n i � 3ina3HOS A111181SNOdS3�l Z 00J +_ti �'ti : d�F�..`5'. 3 .- '(r r4.•y},J't'f ,x•M ^y },t^)J,�" �i 31'� SfZ'r `r.Y��e +oFt,- i �'u yr "�4+. -. I I � � 1HS 139HS MILL 400J ,t � �� U ln011bO 11b13a Su k �l ,� 4,.� x ,,r" 1`�� � .�. �n'`..� rs`1r>, M�'�,�5� -�"�f '- �� NOW� 4"`7 m, �t o- � � lla �-r " n y .ti rta v. ^ : '�- :est HlaON ❑ ❑ .e 133HS 213n00 OOOJ w, - #! ,�. u k r Yrf h r HlaoN ❑ ❑ _ " 44 :]•�I ,,��i� tfIry��Y '4 F 7SY^.•�" A ,•y 'A , g'3q �M'1:F Y *a^r~<< r:'`,`,^r•� Y•;" _-a',m�'," ej�. i c`��dl `",' ' ,, anal iO3r0ad °' us'd.�,yF }}"�H,� 4 tEI ) »{f Y ,L(4L .;' �,�' _� ��r'F^, 1 1HS 1V83N3�J AS y.._ ? n� ' 'x-"4,. r.. '(F.:� , - '- ::'' �' n +? " ^ �a : :�• s.G' -F,sa -. 5 y �r �,sT s._` .� '. ' 3a _, ft , Gl D"d s61E1 a -> a� N01103S GwBN }aayS �a UIn P `t h S`vx T s r , �_ 5 r` 7ak� L .-,5 i' a `�2 "r •t,., ..t..<-", !; `n , 'd,.' -si�L�[i'13�"J;11 ,'• <. i. :cam t 44x s�J:`y�r �, `* j `:.,, -Szc� n: q N + , nxR 9 tit t y,t aT m_ � r w:'3� Y .^} Nto Gar t .''� Nam as 'ice k7S}''`ty .:'�h l'y,11 f-{"'7V Cr.Fy n �? I141u?.4.,, j.'r+ ' p si:. '..b_ ) Y..a u, `� `�'�f.KJ>'x /\�/\�y��//\]/ yS t,_� %l 4. a i�4 *-{ sy� 4' � L-r ¢` ,, •�'Y' >a. x { `{} �i 3 U{j ��'`�iX �Y/ �j ❑ �;< q n �r 7 € :5 .. ,F.,,��:� t.>r 4 k h L ''�w''1` t� t {' 3�t5f'�rA ❑ ❑ a stSs;aq. cil, .;, ..�, Nf^ "". 'j` r,7L 'r:3' r 4 >~ fa i`ri sl.y ,� ¢ o�i.r "=S ISI-1 JNIMb21a � Y:_... ,•. E �',.r r a 4 J2r . _ .v`pE�d�rybt R � E's i_ . 'Ss . ?,f',i `!Wvr2- ,,, t iz " � �r7}✓,t7r. ��4 -h :` s� %s` Ca 9 1HS llbl30 Nbld ,G -,,,-.. G{}L�.-yd {Y�sj. 1t� v.. I( "..5,.-�, , 3� 4 ht.:•..{ y"',k �'`� a r. i. 4"`� �lL •'r•' {w^' ,{F'' F�'RM.-.' ni Fl}yt, L'?�^.,\.i3-.,� V 1 M1 { eh .k': 9Y). :i Y l). f'",,•ll F :1::.. `�I a` W,M 7. 5. -.'".v"'St :" `C„"' fil•. tt+r�l ;ty r`>� ;vim'. .; .�� �.�$'.YG,., O w , ,`ft ., 4� > )",s?y ..+ <k<: ;F,r` ••"�,t "Kvy't{{•k - ''"'•B�Hee`��' '' yP :�{jii .i,. m {.Ff.,v„ `c;n,j. n, .r - .i, r �... .c f ,r.qr »..'4 ..Yt+'7- raJ•_ !Xe n..'Cl..ati -rt,a, 0Vd 0NV 13daV0 WVl-nl`J'DOOM k^ ,,..'��.t a;;, - .,''�,,..�. ''y,_ z,�=�^rr.4 1 .. e%-.I e a -r.. ir • I I ' � <.'S' „:"Y 032d1`J�N0la8 -'�.._. •t '�' c ;'s._x:. `�i# - n n. - ...s ...ss4 _..:rr Lr"v }., •kF .,-•'a,!.-.45 's''t,.' ' I��II� W� 1 �':. 'r-... :�.,.. _ ii.:.., �.�."; #;l 1 +•:Y5 �°v'+'w t::-. � z}1":^. ..<......r.Lx inn l.• L '"'Gr•1���fap�'�.��.'- HSINI� r w, tP` s.:.., a-:. ,;,, !y..; 3� , r�.; -'•�;- �' �.,,r'±4F+r+n� 'v: '=t:r ++sr ,vz trch�'�a r �r �- �}: ,f Pez,yr. �0 ld rF .i Ott .1 'dd .':..'s.",.„ k '.i >!tl.- r: 3. I-"_�.• .9. :r.PI ,r.r:. 1 .re�v,(. .,x. a -7. .c-G.v, tr. 3,..,, Ktr,:,;+.i 1 >'-Fi. -n't bT.,:,, �JNILi00 WIHS �JNINO >:t1t . Ali: ,.s ry�r k��,; :�„ -,..-a. ..L.•,.7+.. v ��-''r "n,.._. ,. .. � c_v., . ,.i.-,•^4 'Ar.-71' .K tt ' -•,c� ' ld DOOM 0l8 y... :'* tr' -_,., yXT ,_ ,, Y ' �. � ."-i ..�``. . P :+- _ a . 1 _v?-V'. v"•,n"n = I•raf t�.-rr+^.. s. ,:,'sytx'`a ..d .a G , �r.. .:F- v. ry r.t+.,, aG,._S r..,.,, s- -. .:v:'.:cµ [ILLLl1J11114 �'� +._^ t }I`f c ,. .Crn. �"ssi''y it. � '•, •::Cmvlu-.4 r. i OOOM �j�I� N0WW00'N0IaB : a :"" r ,.,<. .,.-t. ,.�s+ - ^:•. �' '• ,�.. :h, y tt .n- }. -4 I�_.J a n' "t• ,.+--,, ` �t ,r "1 },[�,3 Pr h ,,.s �,,t 'rx r, . < ,t r Na , .`. , Y.,<. �::} .4 Y. �' �/7/ /�//�I .du}.•,.cr r " 4rt ;l 'li r �, i +s" 1r,3n. '7' `c,">`• 2 �» '`.` fi d "•.n'f .; I_/_L/J� �:�,• ti, r �- �+,�'�' ^' ;�, ..; _s�, � 4 ''� _ . � 'z,}�f d'`� '� .5. ,p 4 �� ''�• NOIS1nM2i � x ,r°� � , �t � ; r;� � _�-�, �n7 try N 1.�b F' •' �?G..t �8 :rxa:. T. �. .>. <�:. x y,..,, •1 .+.;. =,iv ;'*+1� f,e @ 6i3 �1. . 5= '� ctkr�m .rn•-rt,..r,..-,y... .ky r•:r,. =.it7 nh:.. -ef I �.t. s_x_..r .,G e+fi,. .v.> 1n'T t :k ,-+,.+ 'T, <s... r.n ::<: r., t,. .N ,?. '1N0'J'`JNIWHa `4• `tr: .,•-.:,• ,.+ .p "°4�5 '3 s +: r.ai-. a ,�,. '} h t e:" - t:k_ I t- .r V+!, .4 10V 3111 ® :q�r..<_: -, r.�:x. .l . : - qs,' is Imo). -^" ,.a.,l t�> 4i t ' v. „r«,S;^ .,t.'<•b .t .,✓ .>;:. ;},. of ena ��kk .,�;.r_.: ,... •, ,..r; . . ., C, �.��.4 ,:' ,, ._ � 3 - '�'1 -u�, `.: Ci:.=•- ,',sib' ":' r �>`? �:"' . A�,. .u` .,,.R ff.Y. +,m�.� .� I3 1n0a0 ^:._<_`:,.,- ,_y,3< .., . ,f E d. ... e : ,_. li-7="� -' �.F.s•: r_. �t`� ,' f. rtlq t P 11 �i< ,1 :z: N� rr '. ijc k. 1, r OOOM , . q..--;Ft'.•, '' .- :N�'w. n. ., h --' ,- : i F • 1 t �:r.rr t. - .y+r. .�� .,L ., ..,i ..tlyimtfa ,„a yr� v- ti$C• W :. fi .:., - .., u, , T. „t. .s, niba Nollt/n313 �y. �t ..v.�t ns S" 6- F;. '- :V"-•' .^v R1 ,.Y :t w 'r,+ ,,n4: ;.:5, :. :';; '.T:,.'-,•YS -y",a`�!°'$ :?" 7;tf3 yh '2. ! '�- r;�-.k� :7'�CP x'F ..`�:u� .rt :s} .l: ..>:. .w t l,,f :.nt. ;Y°4.i;, _� "`�� .kys >_.�fA k r ,r, > 1_.g�,'i'� .�,, aUae rY rr^... ��-rf! :. �;..vry `•'�.'Sy"bd r '-'1r zrdA`�V- !�y�'� "'�.. ,5;�(�, � p z 1:.. 7tr 't .�1N` zd5-: �'�< y,. _ `.'`�,.+ i �1,. y }r.'4s,JYl,. �.. . '� N ... vva#. Y -;•.,+,1 ""� �,+.' ✓ ..,y „ SS,_ ,c „"...:, +' : ::F, 5?C+. i .r;;�t' 5. .+ s,r11:;1., .r'C,.a'„_, *i,•�t-i1.2,•` u!r,:z. ",'L'n':. » j-:yC.....kv+-' I..t�. ;'"'r•', xr "a 'r5it' __z .,t� _ a^r .r"n-_. ''„<.r', - i1}Y` P.r w?•4a :T+ -. ,f:rw-_z_31 S-=,3%„ '1... . .1'F;.:-• f`. i f I "�... u•.r:^ �.r' ,'.Zf "�,., ..,.z, . . t<q. f'4 a�I ,k_n.. •!...::'•�.-on+;^. ' ,h 1•ti,;.z .,.,. ,1= 3iw:;^." ,t, , lb'-- -•S.i ,r.G-: a-. 'r+n, t,,,. ..vl`n�r ,':t•. yr" rh rG•;E ,{!. 09 .e . . , .:, 'RJ. dA0 . .. . . .. ".. . r �1 . .,. .... 000 - ... r:-!y. .. r _.._ , w. .. "vrrc�!•' ".v,t.. - -..�tk'm. �p�""s .� .., . MAId .-,..:, 3:- . ta• .�4 ,'*"'i"': .;•x. e n �Q 1, 1. ,r -,. .. ® _. .-., : f .:r rA:` <•pr >�"n,., : " Ju �, a ,r. ......_a• .-0 .}..•, ,,• sf. " �' r .,;e?•a '-s" ar .� o r:u ,t f v1- HSINij`Jl0 1H013M1 .,... . ;:. ..t�,A -s•rn' _..s:. HS Hon 313aoNoo � . ,�-t I:s � ( r,,��.�•, ;'= ,� r ��,a 7 ti k rx� �} �'- �-: INId �JNIIiMO"P.t• ; H12i0N n, l,# : _; 1g ... ^> y� eyt,_ n, •�.,"IRML t ,,, E s,as 1H 910 HJ ii G ,i. - 'Y. `+5� S1V13Wa "'*u a . ,-A`-y-,� ,f .t ...,� icrt ea:. .."ky ",r.: F�: r ,..;ei•. pis;i s., i. t ,9i,.,,$,� L ...v;''..4`^-'e?d:.">;§Sul,�, �_�, " cwayT ,v: �5yp.g�G a3N0V8 1NVlb3S 3H10 ... .. r.. � :: , '� �' . ^• :. :.�: '�� `#':4..e<� �- -4., ? a�n.. _ � � Y; -"T f�-s"., ., i 3N01S'313a0N00 :'.. .. .• fir ,, - .'a,"u� "`"'�f7„ J �' ,••§�r..-xiw` - �-= .� ,,., ,,, r " + 4 •: "P>a ry ,t >m:tr ?, r � r �.L1V11L F 1331S s�. 's4� _ w r r -•�a'• ti' :: .G -fc, r t+u- r �r �{ , :" 1 r'pl ,- II�/j////)/////�/�J . .: �,.-� .�^J, ..,,. � �- r p pp ti ,cam• ��� y r��z „ , � MdAl N \, _"�. � �r�1L'v i`ZrG S'��.. ^:-�` +•{ ,rj} � „F`K�$:.La .r n •f-. _ ��',��T. v�'t..':h+a� n'>15'r-. �t.' isy I�}�+i,` ��fs OI111Obd , F`. � s�,Z',?,',-:•:•_ �b d ��' i i::1 r �' � r tl:�',- T+Vy,�- y''4„z. r L ���h -y a L C' ra-i-;,� �. '�yE;lvy,,rt°x !� 4"voFm�� i' ""F.f�' :IVV t '1 h< { •+-� r``". '-7� ),:.u'�3 .rr7 0101H'N0uvinSNl - - W ,ri ,�"��tK'A`.v' '•.�S} 3 k� iY i'1 't e,N�`�'t't:� fs�'��;'*x"ke�: <^. , 9?.�,b 55 �.+`^�3 M00NIM ;t nNIWn1H ///� ONUS _:1�,.'/.,_}ti ,u$c?,r svry�i..., -x�s,:7J60 .as-�`'-.. ak:'1�..�cs .eE ;x'>91�.c"�z_} :1-`.t•:hiu' :!L,s -C:� ' -'�",ss?-, t�.'r._>=`z';ti�,�.!xztz'`.bs.�'�.r:l 35001'N0u'vgnSN1 ® 3N01S TId10VdW00 aooa 101 'HiW3 _ NVId Sf1O0"1 Nbrld A3M 4N303� �0SWAS a38Wnl HSINIj ® NVId'NOOIB SSM'J � 039an1SI0Nn'H12iV3 30V31d'000MJ.ld NVId'niNo ® 13AVa0'HIUV3 GN3031 1d12j31dW � hn wags � H v an N � n K_ O � H n O 0 O a K N O O V W m f0 al K D1 N O n N N N O I -- - - - - - ----- -- - - _------ ---------. --- --- -- - - - -- - - - - -.. . - - - - - -- - -- - -- - - --- - ---—- -- - -- - - -- - - -- — -- -- - RESPONSIBILITY SCHEDULE RESPONSIBILITY SCHEDULE Ui G.C. Owner G.C. Owner a * Note: All items contained within these contract documents are to be the o 0 0 * Note:All items contained within these contract documents are to be the o 0 o m responsibility of the Genral Contractor unless otherwise noted. w T w responsibility of the Genral Contractor unless otherwise noted. of w w E O ¢ O rn ce m CSI DIV. ITEM / DESCRIPTION g U OK E z z REMARKS CSI DIV. ITEM / DESCRIPTION g U ? LL K R REMARKS N 01 GENERAL DATA 10400(coni'd) Interior Signage ! a Building Permit(Interiorfit-up) Sales Area Signage and Graphics X X X; G.C.to assist in the graphics installation during store setup,allow 8 carpenter hours U File X > By Owners Vendor Utility and Rest Room Signage X X X Per plans and specifications Pickup and Pay For X X 10523 Fire Extingushers and Cabinets X X Sign Permit and Fees X ::X: X By Owner's Sign Vendor 10810 Toilet Accessories X X X All Other Permits and Fees X X X Including Security Deposit to Landlord If applicable Shower Room Mirror X X X G.C.to provide blocking 01000.9 Temporary Untilities X X 11 EQUIPMENT Site Communications X X Includes:Phone,Fax,Email,Digital Camera and Cell phone Security Equipment(Loss Prevention) F 0 insurance X X Per Landlord Requirements Conduit,Electrical Boxes and Pull Strings X X G.C.to coordinate with Owner's Vendor E Inspections and Certificates X " X Including documentation for LEED Wiring,Equipment and Devices ::X::::-X::` By Owner's Vendor bC N p O O u Testing X i.e.Xraying Slabs,Fire Alarm etc. Audio-Usual Equipment Storage for Owners Vendors Material and Equipment X Conduit,Electrical Boxes and Pull Stings X X G.C.to coordinate with Owners Vendor Debris Removal and Clean Up X Waste Removal System as required by specifications Wiring,Equipment and Devices X X`. By Owner's Vendor M w° a. w 3 Lease Confirmation Plan X X X G.C.to submit field measurements to verity dimesions Mercantile Equipment ....... ..... :::: Dumpsters X X To be used by operations at store turnover-confirm#required with L.L.Bean P.O.S.and Back of House Equipment X.`X: Conduit by G.C. 01000.15 Final Cleaning X Performed after all work is complete(including owners vendors work) Office Equipment 01000.15 Close Out As-Builts X G.C.to provide close out plan with square footages. Lockers X X' _ . _ 02 SITE WORK Safe X ; :;?;: Landscaping X: X X . . Per Tenant review and approval UNO-Additional work by GC as specified on plan Employee Time Clack X Irrigation System X` Per Tenant review and approval UNO Furniture X Cutting and Patching X X Server/Computer Equipment X. X. See Division 16 Electrical for Additional Information 03 CONCRETE Refrigerator .:.X: 03300 Cast-in Place Concrete X X . X Microwave X: :X Slab on Grade X X X Vending Machines Footings and Foundations X X X For Porch and Vestibule Office Accessories X -X- Footings Concrete X X X Loading Dock Height Leveler X' i 04 MASONRY 12 FURNITURE Unit Masonry Systems X': Hang bars/mirrors in filling rooms X.'. X::: G.C.to provide backing 05 METALS Furniture X `X: 05400 Cold Form Metal Framing X X Plasma Screens 05500 Metal Fabrication X X Conduit,Electrical Boxes and Pull Stings X X G.C.to coordinate with Owners Vendor 06 WOOD & PLASTICS Wiring,Equipment and Devices X 'X:% By Owners Vendor 06105 Rough Carpentry 12482 Entry Mats X X FRT Wood In-Wall Blacking X x See elevations 13 SPECIAL CONSTRUCTION FRT Wood Backing Panels X X For the mounting of equipment,see MEP sheets and elevations Not Used _ ... 06200 Exterior Finish carpentry X X 15 MECHANICAL 06402 Architectural Woodwork = X X X Utilities Serving Lease Area(Chilled Water Lines,Gas,Sewer) X: Brought to Perimeter by LL.Coordinate with MEP Drawings Sales Area Millwork&Hardware X X X See millwork details 1 finish schedule Gas Piping X X Il to bring gas to meter manifold location Fixture Blocking X X Coordinate with Project Manager and fixture shop drawings and details Plumbing Fixtures and Accessories X X X Back of House Shelving&Hardware X X Per plans and specifications. Rolling shelving installed by owners vendor. Water Coolers and Drinking Fountains X X X Back of house,Countertops and Hardware :: X X Per plans and specifications Domestic Water Heaters X X X Standing and Running Trim X I X X Equipment Rough-In X X Coordinate with MEP Drawings Perimeter Fixtures X X ;XT See millwork details I finish schedule Final Connection X X Freestanding Fixtures X :X: Floor Drains X X 07 THERMAL & MOISTURE PROTECTION Air Conditioner Drains X X 07210 Exterior Wall Insulation 54 X Supplied by Owner,installed by GC Roof Top Units X X X Coordinate with MEP Drawings 07210 Interior Wall Insulation X X Roof Curb and Sealed Roof Connections X: 07410 Metal Panel Roof System X X ;t _: X Distribution System:Duct Work,Fans and Diffusers X X X 07530 EPOMRoof X X At Vestibule Thermostats and Controls X X ;; : :;i.';i X 07600 Flashing and sheet metal X X Testing,Adjusting and Air Balancing X X X Certified Independent Contractor to submit report to Architect,Project Mgr and Owner 07840 Fire Stopping X X Fire ProtectionfSprinklerSystern 07900 Caulking and Sealants X X Pumps and Sprinkler Main Piping Connection stubbed to space by LL .... ...... 08 DOORS & WINDOWS Branch Piping and Heads X X .` X Submit layout to Architect for approval before starting the work 08110 Steel Doors-Exterior Service Door&Frame Xt Weather stripping and hardware by GC Testing and Tie-in with Base Building System X X Coordinate Work with Landlord-include LL shutdown fees 08110 Steel Doors&Frames X X Shop Drawings I Hydraulic Calculations X X Coordinate Work with Landlord-include LL shutdown fees 08210 Wood Doors and Frames X X X Annotators/Stobe System X X Coordinate Work with Landlord-include LL shutdown fees 08310 Access Doors and Panels X X See plans for locations 16 ELECTRICAL 06330 Overhead Door X' At Loading Dock Electrical Conduit for Switchgear X1 L to provide conduit to perimeter of space 08410 Aluminum Entrances and Storefront X X X At vestibules only Electrical Service and Meter X X j Base X X At vestibules only Transformers and Switch Gear X X X Kv 02.09.07_ IssuE FOR BID Gaskets&Accessories X X At vestibules only Panels,Circuit Breaker and Accessories X X X No By Date Description 08410 Storefront System(including glazing) X'- Coordinate with Section 05500-Landlord to provide complete except at vestibule Distribution Wiring,Raceways,Boxes and Devices X X X L.L. Bean Base X At vestibules only Exterior Luminaires X X.;; .,. X C)p CC), ,,, Gaskets and Accessories X. At vestibules only Lighting Control Panel X X X 08710 Door Hardware X X X Emergency Lights and Exit Signs X 08740 Power Door Operators X X X Telephone Panel,Cabling,and Distribution X X Conduit&pullstring to space by LL I ' 08800 Glazing X X X Telephone Service and Equipment Sunfilm X X X Luminaires Sales Area Mirrors X: .X G.C.to provide blocking Interior Luminaires X Xt i Fitting Room Mirrors X X.' G.C.to provide blocking and power Conduit, Boxes and Pull Strings X X �.; Toilet Room Mirrors X X' G.C.to provide blocking Wiring;Data Wire X X 09 FINISHES Data Wiring and Devices 09250 Gypsum Wall Board and Accessories X X Conduit, Boxes and Pull Stings X X Include 1112"conduit to LL Telephone Room Demising Walls X X G.C.to ensure 1 hr assembly Wiring,Equipment and Devices X -X: fi Interior Partitions X X Sign Conduit and Wiring X X .._.. ...... Acoustical Insulation X x outlets and Switches X X ai ; The Shops at Evergreen Walk 75 Tamarack Ave 09300 Tleand Grout X X X Security System X: X;: Conduit by G.C. Building C, Suite 75 09510 Acoustical Ceiling Tiles and Suspension System X X AudioNisual System X`:. Conduit by GC South Windsor, CT 06074 09637 Stone X X X Speakers X' .X', Conduit by GC RESPONSIBILITY Floor Leveling X X Speaker Wire Conduit,J-Boxes,&Pull Strings X X SCHEDULE 09640 Wood X X X Uninterrupted Power Source X X 09652 Resilient Base X X X Computer Cable X X Adhesive X X Temporary Utilities Charges X X 09662 Carpet X X X POS System X. X Conduit by G.C. Checked By: Checker 09910 Paints,Stain and Transparent Finishes(Field Applied) X X X GENERAL NOTES: Job No: 06125.00 10 SPECIALTIES 10100 Tackboards X X X G.C. shall employ superintendent with onsite laptop and digital camera email ready. Each Thursday superintendent shall submit 10-15 digital photos to 10161 Metal Toilet Partitions X X X Project Manager illustrating the progress of the project and any specific issues that need addressing. Sufficient jobsite lighting is required to ensure clear images. GOO-2 10260 3"Stainless Steel Comer Guards X X X Provide on outside exposed comers in stock only G.C. shall provide dumpsters to be used by operations at store turnover. 10400 EzteriotlEntry Signage X: ::X G.C.to provide power and final connection *Vital Information for the successful completion of the work is contained in the Specifications prepared for this project.* ---.. ------------ _.. _ ... . . - _ ._ _ -._._.--- -------_... ---. -- --- ..__. _ _ __- ... - - . . ... _ _ _ . _. _. .__.. . _-. .. _ __ . .. - -..-... _ ._. .....__.-- ----- - --- --- _._ _. _ _. .. . ------ _ _------- --- _ C.1RevitlSWi ndsor1125-base_local-sh(Recovery).rvt 2/9/2007 12:49:27 PM LEASE CONFIRMATION NOTES TYP. BEFORE STARTING CONSTRUCTION,THE GC IS REQUIRED TO VERIFY THE INFORMATION REQUESTED ON THIS DRAWING.UPON COMPLETION OF THE LEASE CONFIRMATION DRAWING,THE GC IS REQUIRED TO SUBMIT ONE COPY TO THE ARCHITECT. IF THERE ARE ANY SIGNIFICANT16 DISCREPANCIES BETWEEN THIS FIELD VERIFICATION AND THE DRAWINGS,THE GENERAL CONTRACTOR IS TO NOTIFY THE ARCHITECT IMMEDIATELY. o FURTHERMORE, IF THERE ARE ANY ITEMS THAT CONFLICT WITH THE SCOPE OF THIS PROJECT THAT DO NOT APPEAR ON THIS LEASE CONFIRMATION m DRAWING,IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY AND COORDINATE WITH THE ARCHITECT. (D ro E 2 m o 0 N L m •T O. U i 40'-0" 40'-0" 35'-0" 40'-0" 17'-6" CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED V C. — — 173'_6" 0 E - I I �L-�� CONFIRMED � G004 v ¢� n � no pmp v ', 1 � So CONFIRMED CONFIRMED I p u e. C q a O a - — — — — — — — — — — — 5 W r p a Q w F fi 6"ROOF DRAIN 6"ROOF DRAIN O t O a7 LL U U T � I I I I I I I I w L - w LL .d K aD O Z U 50 o W Z N p U I w _ p w d' E 4, 6„ ,6 -1„ Q o - p I I I I I p LADDER TO LOWER ROOF BY LL CONFIRMED CONFIRMED — — — — — — — — — — — — — — — — — — — — a I � LL Z I I I I I ih w _ M ¢ z NIE 0 p I I I I I i - Z 8"ROOF DRAIN I 8"ROOF DRAIN w U I — — — — — — — — LL � 3 � U U I I I I I I I I I I I I I I I I I I 0 O Z e{ U ' u _ 0 G004 i 0 I I I I � o � U — -- — — — — - — — — — — — — — — I I I I I I I KV 02.09.07 ISSUE FORBID No By Date escriplion ❑ L.L. Bean pFF co'tC\,� 0 U , I I I I I I I 1' I,r CONFIRMED9. 6"ROOF DRAINS CONFIRMED CONFIRMED IVVVN \\1 J 8"ROOF DRAINS coNFiRMED I CONFIRMED pi I I I Z CONFIRMED �I'L t a — v wit 0 7t U 9n au — — — — — — — ' — — I — — — — — The Shops at Evergreen Walk 6"ROOF DRAINS 6"ROOF DRAINS kj 6"ROOF DRAINS I 75 Tamarack Ave CONFIRMED CONFIRMED ; Building C, Suite 75 28'-9" a'-4° 6' s" 8'-4" 18'-8" 8'-4" I3'-5" South Windsor, CT06074 0 0 0 0 l u D I 0 0 I LEASE CONFIRMATION CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED CONFIRMED PLAN F E D C.7 C.2 C B A Checked By: Checker Lease Confirmation PlanConfirmation Plan Job No: 06125.00 �118" - 1'-0- 1'-0" I _ _ ._. - _ .- -- G003 _ _ _ _ - - __. ._ _ .__ _. --- C:1RevitlSW i.ndsor1125-base_local-sh(Recove_ _ _ _.. . ._ - -ry).rvt_ . 2/9/2007 12:49:32 PM .--.-__. - _._ - ----- ---- I to CD Nam: S i N W N a m N 1� 1 A : al ; y : S Aj I fD ', N ' I 2 .+i I I i i i i - N N N O? N cq0 II (D II (D C-) 0 O O Q O C om 1 1 3 3 1 O O CD '.y. 0 j Z m o m rn 29'-01/2" UNDERSIDE OF DECK 29'- 1" UNDERSIDE OF DECK CONFIRMED CONFIRMED 26'-8 1/2"B.O.STEEL JOISTS 26'-7"B.O.STEEL JOISTS CONFIRMED CONFIRMED i 26'-7"B.O.STEEL JOISTS 15'-0 1/4"TOP OF WINDOWS, TYP. CONFIRMED CONFIRMED � I I i i I i i 1 Z 37'-0" UNDERSIDE OF DECK CONFIRMED I — — — — — — � 349" B.O. STEEL JOISTS 0 CONFIRMED 26'-7"B.O.STEEL JOISTS 27'-9"B.O. STEEL JOISTS CONFIRMED CONFIRMED 35'-4"B.O. STEEL JOISTS CONFIRMED 37'-0" UNDERSIDE OF DECK — — — — — — N CONFIRMED 35'-0" B.O. STEEL JOISTS CONFIRMED I G I 26'-7"B.O.STEEL JOISTS -11 0T0-i G�7C�x 26'-7"B.O. STEEL JOISTS ��m W CONFIRMED z m v 0 G)gDOo CONFIRMED m 0 m nrnz-1 mx DZ =Xmm"a0 mmmoo zz com DZ zz„*c \� = co =z �s ;mum i o =:t6)x x0- c) ozzmN Zr—> cm m--i m Co 0 -4m C C � -1M0a W r- Z 0z A�0C0 c > Rr1 Om��< m 4' B.O. STEEL JOISTS 27'-7"B.O.STEEL JOISTS n 0 m X m � n z�� 0 (� 0 C - � - cn — i0cnz� z z_n N D � 0 0 � � � {mxmm CONFIRMED CD w - a o m m C) rZ N 00 N XO zmmo- 0-I +0TZ — 0 C)xm-< n 29'-1"UNDERSIDE OF DECK 0 A O M Z Z�o 6 m CONFIRMED A n z z m mm � 49 irn — — — � 00-.Ol CO , x0X-'-1 mz�n 0 0> mz C C x-ozm- X m N m rn �O�Da to � cn - mcn zmz<� o o 0 0 =DrnZ CD s Om s Om �-)n0P < OO X0 Z—ta O (p fV -n -n n 0 mozo 0 10 T m -ro Ao_ m DD -1 O -i m z z 0 o n (� (� Cn CO -4 -i r o O CCD 7 ny � . >v � Bet., z m fn X- vR > m ' ® n m 9 Ti o u' i v7 ' ' o Architecture and Interiors p C oA Bergmeyer Architectural P.C. GC) 51 Sleeper Street n D Boston,b1A 02210 N m Phone 617 5421025 Fax 617 5421026 C) xx. Z I www.bergmeyer.com ©Copyright 2007 Bergmeyer Associates, Inc. CONSTRUCTION NOTES A. GENERAL 6 1. SEE SPECIFICATIONS FOR ADDITIONAL NOTES AND REQUIREMENTS 2. SEE RESPONSIBILITY SCHEDULE FOR DIVISION OF LABOR. a IL ) 3. G.C. IS RESPONSIBLE FOR MAINTAINING THE FIRE RATING INTREGRITY AT ALL DEMISING & FIRE RATED WALLS AS WELL AS AT THE SLAB, TYPICAL E THROUGHOUT. m 4. G.C. IS RESPONSIBLE FOR THE INSTALLATION OF FIRE RETARDANT BLOCKING o IN THE WALLS AND CEILINGS, SEE ELEVATIONS AND DETAILS FOR LOCATIONS OF BLOCKING. COORDINATE WITH FIXTURE CONTRACTOR FOR FIXTURE BLOCKING REQUIREMENTS. 5. G.C. IS RESPONSIBLE FOR THE INSTALLATION OF PLYWOOD BACKING ON WALLS FOR THE MOUNTING OF EQUIPMENT (I.E. TEUELEC PANELS). REFER TO CONSTRUCTION PLAN AND ENGINEERING DRAWINGS FOR LOCATIONS OF EQUIPMENT. e e e e s e e e e e e s s e e s s e e e e e e e e 1 B. LAYOUT WALL MOUNTED 1 1. LAYOUT PARTITIONS STARTING FROM CONDITIONS WHERE ALIGNMENT WITH ER I EXISTING CONDITIONS IS SHOWN, U.O.N. FIRE EXTINGUISH la 2 I 1 2. DRAWINGS ARE NOT TO BE SCALED, DIMENSIONS GOVERN. IF DIMENSIONS A301 65'-11 1/4" I ARE MISSING G.C. SHALL NOTIFY ARCHITECT FOR DIRECTION. p, 3. ALL DIMENSIONS ARE FROM FINISH SURFACE TO FINISH SURFACE, U.O.N. DECORATIVE MATERIALS ARE TO BE APPLIED AFTER THE FINISH DIMENSIONS o o -o _ - - _ _ HaA HAVE BEEN CONFIMRED. � �" N H— LEH 4. G.C. TO VERIFY THAT ALL EXISTING DEMISING WALLS ARE PLUMB. IFNOT, G C.TO PROVIDE AND INSTALL FURRING AND GWB TO MAKE PLUMB. ya It STOCK ROOM I OFFICE O WOFE RM UCOM EMPLOY E LOUNG ^ °127I' RM C. COORDINATION 0 -0- 1. G.C. SHALL VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT IMMEDIATELY OF - 12512a - - - ® 111 ANY DISCREPENCIES. 2. G.C. TO NOTIFY ARCHITECT AFTER LAYOUT AND PRIOR TO FRAMING IF: - DIMENSION LABELED +/-VARIES MORE THAN 2" FROM ACTUAL FIELD O' DN I MEASUREMENT. 32'-10 vz° 3'-53/ " 9'-10" 3'-51/2". z9'-81/z" UTILITY CLST - i - DIMENSIONS LABELED "MIN" CANNOT BE ACHIEVED. 1 16'-41/4" A203 - o A203 117 I -ANY DISCREPENCY, OMISSION OR UNANTICIPATED FIELD CONDITION 1 ( 32'-73/a" 1 ` ' 1 ALTERS THE INTENT OF THESE DRAWINGS. 29 N M'EN'SR 1 5 9 N 128 1 A204 a OOM 1 3. G.C. IS RESPONSIBLE FOR COORDINATING ALL LAYOUT ISSUES WITH THE r W I A502 o g - 0 116 1 MILLWORKER TO ESTABLISH MILLWORK LAYOUTS CABINETS PORTALS DOORS & a 1 M 2 s� I FRAMES ETC.). G.C. TO COORDINATE MILLWORK SUBMITTALS PRIOR TO ANY A24� RETURNSO i Azo3 � 134 A2oa 3 \ I, I I FRAMING. I— :o 8 d'� ` N �o` 121 O HAr 4. G.C. SHALL SUPPLY FIELD CONDITIONS AND DIMENSIONS TO THE ARCHITECT, L MILLWORKER, OWNER AND OWNER'S CONTRACTORS UPON REQUEST. A203- 5. G.C. RESPONSIBLE FOR ALL PREPARATION WORK REQUIRED TO INSTALL NEW A203 14r3 1/4" A203O FLOORING TO MANUFACTURERS SPECIFICATION. 6. G.C. TO COORDINATE WITH OWNERS VENDORS TO ALLOW FOR PROPER 21/2" SIMa6 6 O INSTALLATION OF ALL OWNER SUPPLIED ITEMS. G.C. TO SCHEDULE DELIVERY INSTALLATION DATES AT THE BEGINNING OF THE JOB TO GURANTEE 1 3 TYP.@ ALL 7 A211 A502 �03 A502 r _ 1 OUTSIDE CORNERS a - I OMEN S RESTROOM A509 IN STOCK ROOM i c COMPLIANCE WITH CONSTRUCTION SCHEDULE. A2o3 a r 7. REFER TO SHEETA-601 FOR PARTITION TYPES LEGEND. j Nlc �� s 11s POS M - 11s I i 8. REFER TO DEVICE PLAN & ELECT. DWGS FOR FLOOR POWER BOXES. a N 9. SEE ENLARGED PLANS FOR DIMENSIONS, PARTITION TYPES AND DOOR KEYS 1 @ TYP. FIRE EXTINGUISHER WHICH ARE NOT SHOWN ON CONSTRUCTION PLAN. 2'-3"3'-0" 23'-21/2" jj r - A509 CABINET DETAIL I ti9 s I I I 5 A203 3 @ COLUMN CALLOUT 4 i @ KAYAK WALL 1 Al 1 A101 °C COLUMN CALLOUT DETAIL A503 �� A20a I I 1 HOUSEBACKOF 6'-11" _ _ _ _ MONOGRAM ING RM 1'-1 1/2" re re i � 7.75 e e e e e eee re e e e e e e eeele e e eee e e r e e e e e a ee e e e eee ee a er e e e e e e e ee e r e ee ele eer eeeeeee ED _ �07 PAN WALL PHASE LEGEND a'-a" 1s'-s" 8'-3" e e e e e e e e e r e e e r + e r e e e e e e r e a e e r re e e e r e e e e e e e e e e e e ^ r .: 0 EXISTING PARTITION BY LANDLORD A203 — — Ir. ee ere �l ` -- — � — \ 1 — eew NEW PARTITION - SEE WALL TYPES ON A601 17 -s° NEW LOW WALL- SEE WALL TYPES ON A601 i 1 / 15,-0" ♦ A507 P BIKE SHOP \ AL 7 ;G +1'- 1 3/4" J I 3 D GEAR WALL ♦ / A 1 DETAIL \ 5' `! I / ♦ , 1 /. ;� �,; '' � A502 �~�. i h9 /�1 F 2 A201 /a 21'-4" 1 ; A503 ` 143 // 1 A204 8 / ILL 2'-7 112"VIF UP DETAIL TYP. FOR 24'-7" 16'_2" ENCLOSED COLUMNS ;,;/,': 1A a A503 FIE] 4 ---C2 I l ---- A503 I 5 ROOF DRAIN LEADERS -I e e e e e e s e e e e a eee e e e e e e e er ALIGN WALL FACES i 7A COLUMN BY LL, ENCLOSURE BY GC A203 1 z I n COLUMN0C1 I 3 @ FIRE EXTINGUISHER 1 @ CASH WRAP I A802 A504 ALIGN CABINET DETAIL A212 ENLARGED PLAN _ __ KV __0_2.09.07 ISSUE FOR BID i SALES AREA @ HIKING I CAMPING PLATFORM D _ e e A203 I i 00 00 ENLARGED PLAN No B Date Description eee I A204 L.L. Bean 1 2 00 / , 5 iv 76 @ MEN'S FITTI q A204 RM ENLARGE ( \ 1 / , A202 VEST a f o 1 @ WOMEN'S FITTING RM PLAN 137 + 1 @ VESTIBULE I I I 1 A205 ENLARGED PLAN CASH WRAP ` 4 A202 1 A401 ENLARGED PLAN ( I 1 I f 1 1 N I 1 A203 5A , 113 112 111 110 I0 BIKE RACK BY OWNER MEN S FITTING ROOM I 138 - I 5 I I A 01 @ COLUMN CALLOUT — A202 1 e e e1 1 e e r e eee ( SIM I I IQ ROOF DRAIN LEADER r r A202 6 f - T - T - - T - T - T - - T - T - T - T - T - I FE — 78 A2041 I 9 I� 139 140 ASH WRAP CL 1 r A509 106 107 108 109 I ° ENCLOSURE BY GC 7 0 2 �12b2 103 104 I SIM l 5 e I — _ _ — _ a— — ST BUL — r f _T_T -1 -T - T - T - 1 A509 r _T o I COLUMN BY LL ` eeeereee e --_. A202 -- —� -� - - eeeeeeeCOLUMN3D 7A 26'-0:: — — — A202 — — — — — — — 7A 34'-10" �29'3� 2'-3" g 10l a 1oz 1 WOMEN'S FITTING ROOM' -I} e — eee ® — eee e. , - - - - - - - ® ® PLANTINGWalk BED BY LL ;O The Shops k Evergreen a 75 Tamarack Ave - - - - - - - - - - - - - - - - -I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - fi - - - - - - - - -- - - - - - - - - - - - - - - - - -r - � I Building C, Suite 75 29'-41/4" South Windsor, CT 06074 F C 2'-8"VIF D C.7 C.2 C g A ! CONSTRUCTION PLAN 1 M �N Azo1 _ checked By: Checker \ Job No: 06125.00 12"DIA.DUCT PENETRATING SLAB ROOF DRAIN LEADER --- --- — COLUMN BY LL ENCLOSURE BY GC n COLUMN 3C Al 0 1 CONSTRUCTION PLAN C:NReviH125-base IocaIjen.rvt... 2/9/2007 1:39:09 PM ...... _. LIGHT FIXTURE LEGEND & SCHEDULE VMMM TYPE DESCRIPTION LOCATION MOUNTING 0 ® Pendant linear fluorescent downlight with blade baffles Perimeter walls Hung with aircraft cabal at 16'-0"AFF m L1 over sales floor and 14'-0"AFF over fitting rooms. Finish per architect. Industrial(3)lamp cross section linear fluorescent work light BOH Stockroom Fixture quantity, spacing and mounting E 0 with wire guard. height lobe verified by client and/or m L4 electrical engineer. r` 0 Bare strip linear fluorescent in architectural mirror detail Fitting room mirrors Coordinate 2',T&4'lengths with N L5 architectural drawings. a o Linear fluorescent stacklight Cashwrap&Bike Mounted centered between wood U L6 Area joists in cashwrap and bike shop. O U Linear fluorescent square form wall-bracketed downlight w/ Above bike shop Mounted to soffit above on inside of L7 blade baffles counter shop area 0 Linear fluorescent wall slot Bathroom wet-wall. L8 High-bay spun alunimum pendant compact fluorescent General ambient light I6-0"AFF @ lower roof,20'-0"AFF Qdownlight+(1)compact fluorescent uplight w/internal reflector @ clerestory. P1A &lens. Dual switched with daylight. LL Bean Green, / Decorative compact fluorescent or metal halide Porch&Vestibule Hung from J-box on hang-straight 0 uplight/downlight pendant. swivel. On porch,coordinate spacing 8 O P2 to fall equal between rafters. Y o 0 0 ° 12'-8" 12'-8" 12'-8" 12'-8" 12'-8" 12'-8" 12'_8" IT-8" ' 12'-8" 12'-8" 12'-8" 12'-8" Fitting Room,general ro o N � >" Decortative compact fluorescent pendant with custom shade: g 9 10'-0' AFF „ 1 1 LL Bean Wallpaper. area y � . . 1 . . . . . . . . . . . . . . . OP3 r- Recessed 2'x4'troffer with acrylic lens v o ---- - - - O R1 BOH Staff areas ACT ceilings-8'-0"AFF wQ w� 5 ( ;I � __ II n II II II BIKE LIFT LOCATIONS, - - - - - R2 Recessed 2 x2 troffer with acrylic lens. BOH Staff areas ACT ceilings-8 0 AFFTYP. FOR(3) It @ B.O.H. ENLARGED -- - - - -- PLANS Recessed compact fluorescent do g Restrooms, Hall to GWB ceilings-15'-0"AFF o R3 estrooms&Return '— — - — -_— - — _. — - — - - — - ---_ - �L - - --- - u - -----__ - ------- -- -_-- wl I I .___ . —_ __ ._ _. _ ..-_ - II-----� ----- _ I "lantern" R s L4 L4 L4 L4 ( 14 L4 L4 �� L4 _ .. _. I _._._- i 1 -- _-- __--- _.-- . ____._ _ --_ . ._ _ ._ - - -..____. _._._---- _-__. .. - . �. -_._..---- ___. .___ I - I._____ -- ---r_ --_i_ _ _ o Surface mounted decotrative lantern with opal glass Cashwrap and Returns Mounted to wood decking ceiling ° I I 8 @RETURNS _ _ - e _ - _ - _ e - _ _ - - - e e _ _ _ _ _ = _ - _ it T - _ r S1 compact fluorescent tamping- between joists-V-0"AFF. —-1 -' A211 ENLARGED PLAN I I t I r Pendant mounted(2)circuit track with V-0"suspension Sales area @ 15'-0"AFF @ Lower Roof - - - - - - - - - - - - = I I i i L- -� TAspacing. Black finish. - - L4- - - - r - -L4r - -L4 - - - - - - - - - - L4 L4 0 EQ EO = r 1 I —� r o I r -. _ _. _ - _ _ _ a ^ r 4 L4 Track mounted Metal Halide object fixture with adjustable Sales area Attached to track(TA),four heads v 1 I i I i r ;p 24 B.O.H. m spread knob,concentric ring baffle, n/off switch and per track _ 1 -6" - r- A210 ENLARGED T1 beam d ob c ffle o i black finish. ---- - _._----. __ . ____. _._!- ._-_. i�----- - .__. 1l.__._- - __ . ._ _. <"o _. . - ------- .._.....-- -- ....-.._ .. ._ - .. ._ L4 - _.. .__ ..... ._...- ' _�___- --------____ '-- -____.... - �- -- --- ___.._. 00 PLANS I - - - - - - - - I '- - - - - - - - - - - -I- 1 i I I I - 4 ;p, - - I L1 - �l - . --L1 -p -- i L1" L1 i l i -- -_ j i - - " 0 3 Gooseneck bracketed k ered ch pact fluorescent sign light w/angle cSignage ashwra at entry and Wall mounted above graphics - - - --' G s N L�' - - - -� o (- - reflector. Fm p r It p F T 4 3 TA TA L4 4 L4 L4 L4 ii L4__ r N _- - B I _ L1 Jill 11 _ i i 1 r o Compact fluorescent decorative opal sconce. Over fitting room doors 6'-8"AFF I — -- --- — -- ._. -_-- -rTE _ — r-- 4 oI ' 0 6'_2' 4, I I L1 W4 o ",3' 4" - 'o _ �P1A I L7 .r '0'• ® PIA I I -- r ... �:�o --- --- -- -------------- -----=1 ---- I-- 1 ---- -- �, -- _ 1. _-. - -- -- r I o zo Compact fluorescent decorative sconce with opal lens. Bathroom Mounted between public bathroom = TA TA I L1 � I ( W5 vanity mirrors,CL @ 5'-0"AFF. See --r,-.- _.- .__-__. _.- ------------ '--.-_.__..--_.-__-_I-----.___-__--._-- ---. . .____ -.I ,_...j---_------------• --= ------- If) -- - I - ------- 1 -------_I-__ o _.. j1..__._ ...... -. ..I '�" elevations. 1 �1L4RCP NOTES I I -�- - --- h - -- TA 1 I TA I I I I 1 r v LI 1. ALL DIMENSIONS TO CENTER LINE OF FIXTURE U.N.O. �P1A _ I o _ PIA 2. OWNER TO PROVIDE TRACK HEADS GC TO INSTALL. -- -- _ i 12'-0" 7 -9 _ I I - � ( , ANY CONFLICT BETWEEN STRUCTURE MECHANICAL I 4. CONSULT ARCHITECT FOR DIRECTION WITH r-r, I 1'-5" - , I N I i _ I V7 1 511_ __ . .., � --ZD -- - ---- --- --- - ._. ._ I I - - - -- ----- ------- _ .. _ � EQUIPMENT, SPRINKLERS, ETC. & LIGHTING I I - ^ 6PIA I - i- — + — - — - 1 I I -- L1 a 5. LOWER LEVEL LIGHTING SHOWN ON ENLARGED PLANS, AS INDICATED. L1 I I - PIA I �P1A _ _ — 6. HATCHED AREA REPRESENTS THE CLERESTORY CEILING. \ P1A TA N TA 1 OP1A I 1 I I 7. PAINT UNDERSIDE OF ROOF DECK ALL JOISTS DUCTWORK FRAMING, CONDUIT ETC. PT-02. -_ ` �✓ 1 T-6'---._ Li 6'_5"---- 5'-9 i---7'-6"_.__ T-5' -10'_9„ -5'_4" --- 11-_7.. -- 4' 2" --7' 8"— -5'_0„- 6,_4„- 3 _2" 4'"0„ -- - - - o -.9 C i- -- -�---- - ---- I` �- - ----- ---- — 8. PAINT ALL MAIN BEAMS IN CEILING (AS NOTED ON PLAN) PT-07. _ v ^ I \\ i \� CH 29'-01l2" I I 1 - C11 -- PT 07 - \ -- __ - -_� I I PT 02 i Ll I I JI i r t 1 1r _ 1_0 .. TA TA /l." \ ' , TA ' ♦\:`, '` -TA.. \12.'-8'" \ ` `T8A'-, 11"♦ //r„r ^TA11_'-_1"`.` `\ TA10`.y'r-;2•: - TA9 -`1\1T"A \\—` — -, TA I PIA__,_ PIA 102 '-10 6 I — RCP WALL LEGEND 3 i I ( PT 07 , v '♦ O.-a- y\ ` \.TA \ ♦. . r ' ;:\♦ \ . 'v I l = = I ALIGN` \ ♦ 'v '\ �\ O N \ x \ PIA. \ / .♦ - - ------ I L ------"----- — ----� . ' ` �. •: \ ..\ @BIKESHOP L1 1 j I ♦ \ �/ TA `\ I'` Oii `\' \ jb ` `ENLARGED o : WALL BY LL, FULL HEIGHT o ?! P 1A I I N . TA ,I PIA �, \ I '` \\\ :5 \: ` .�, \,.f... ii - ' `♦ ,I� `N"iN PLANS', 'I PIA TAN \ \ J _\ o. P1A. ,, . . I - 17) - N. LI I ' r 1 ' I — -1 — I o -\ r. ` ^7C, `\ ♦ .P1A `� ♦ `\ '♦ I `. -.I I` P1A `. - o. — .. ------ ---- 1 ------- ------- --__--- i I-i TAB \, , 5'-0 3/4" `, , ♦ •, 6 , r `,, \, \ ',., ., \ ., \ ``..TA ., \\., \ '` '\ 'rt.' o � , . _ _ , ," ' WALL 8Y G FULL HEIGHT .,\ .� ♦\\ :..`` ♦ `� � \\\\ ;''♦ � Oo . �.\ __ _—�----I--_�•. 'r a1..'...g..4_fijr�F;.:� CI PlA rim I) ( PARALLEL 0 TA T I \♦,.... \ '.II - - - - - - - - - - 1 I \ ` ALIGN' .- \ > \ -" . %. I ` o 1 r t T �o i• I P`. .. WALL BY GC PARTIAL HEIGHT O WALL I ; , i I I i \ I I 1 \� i1, � T \ _ y I _ ,., .� ,�:` PARALLEL,-I' PIA - t L1 I I I I \v p,. 2'_0'4 \ TA ♦`'��` i� h \ T - - — - ?`'I� TO WALL a } —i n I AI b ,Tq I I \ i / TA. o I PIP I PIA ' TA` t. I,\ \ \ \ ♦ TA o = - - -- zo i --- --......... - - ' \ ll J-r l L1 PARALLEL I'`- \ _,;\ 1 . I `\ CH 36 11".. 14 - I \ 0 TO WALL �'• \ PT-02 `,:.` . L, \ ..�y \♦ �o _ m. l = I I 1 \ \I`\ PIA. \ N \ I I1 _ CPIA I PIA \ I, m Y ,ro`t' M ♦ `60 \ \\' \ .I r i.- kf• `♦' FQ, \ .I \_ ITAI -1---- ----- io - `- N - -TA r \ ' N kb \ \\ n �. C \ `to\ TA T . '\ TA ;y�CF L1 TA I n TA A Pi w PIA Q �' `\ A TA PARALLEL \ P• \ ` \ .' \ o \ \ r, < `PIA 0 11 I I TO WALL I \ `♦"i, \ \ ` \ 1 \ \ -� \\ e 1\\ x TA ' o y I \ o < TA \ \ \ \ PIA i 11 _�„ \14' 6 �?� `\ 14 -4" \ 14 -5"rK 'TA . 1 '-5'1'.., O" \ \ : 11'_0„ I .. L1. 17'-5 P1 l L -TA = 1 i .4'-7 9'`-I1" \` ' '10 -2" \10 1' \ ` '`9'-7" \7 -11 `,.7 3 m `TA _. : TA -- - TA_ TA ' \\`\ 2 0 -'' �= - - - -'TA- TA '— --TA. TA G - PIA TA - - 1 - - j((pp�� - - - - - - - - - = \ ♦ \\ ,. `. E(� • -� 10,_2„ - rI 10,_Z„ --- PIA l� \ \ \ EO �- - -1----- --- to \ \ , i i L1 TA I _`i \ I ... \\ 0�1: 1 I S), -1 TA II -- -- - 1 1 \ I PT 07 -- -- - - -- - - -- --- -- -- ---L --- --- ir � — — - - lP1A- — - 1 \ \ \ I PT 07 ; m �P P1A N PIA j I P1AI - - I -I— - f 1 N TA ,,\ \ \ i\ \ \ L \ TA I I L1 r N I I I v t0 ' \ - - \ h —__-- - - - - -- E o `\ b S)ol j I M - _TA_ .._. .. -- - - I ---- I I --I--- -- I I TA I'` PIA \ TA. PIA ` `` --- - - T - ---`- --- --- - -- - . _ . _ - No By Date9.0 Descript o R B I '` t�P1A TA j� KV 7 ID .i o E I I' - -� I I --.I 1 \ \\ \\'\ �\ \ ` \ i j I � TA it �P1A- J - I j - -TP1A-I— - + - I \ 8� \ \\ \ \ I \ \ \\ \ TA L-_i I I TA I a L L. Bean-, \ f 1 TA I- TA ` - - -- - --4 1 I I r Lei 1 PT 07 \ 1 ` r \. v TA I I I TA `7 1 I I I I I TA 1 L � , P1A- I- - � � I TA : 1 \\\ \' \ \` '` `\0 1 I I A 1 L1 1 LI 1 r \\\ r- r r- N P1Aj � I i \ TA \ . MEWS FITTING10 ♦ I I .r1 Q L1` \ \ I ♦ \ \..(� I N 1 ROOM ENLARGED PIA PIA\\ M I i, I I r PLANS r 11I 6 I I I I 1 \ \ ' - --1�---------.._.II I I� /---- -- ---I--- --- ---I- --i I i- - --�----_ i - -- ----I---- �,.I `.\ I -♦\, I . - TA -------I ---I---- -------- -I------ -------- ---- -i - 1---- - --- =dl ll \ m _ 7i I L L1 - I io TA I j P1A- - — - P1A• \ `♦, \ \ `. \\r I I iir I I�.j.jl ( I I , � 1 I � ,�� \ ♦ ` `, eo I L - r L1 TA `;' I `,I� 3i`;P.� \ \`\\ \ oTA i I i ri I I I I I r o, A805 NLA ENLARGED PLANS FITTING ROOM ♦ , c� ( L1 I I i i I: L1 - I I L1 I I` L1 - - 'I L1 �\ y� � � , \ � .�� . •. \ \ 1 I � _r, 1 i T Ll I!rn ( I o L1I �. I - il� J I n j �tTA. D \ \ , ♦ `\ \\� a i o L1 L1 L1 c r I r I TA n I - - 21 TA The Shops at Evergreen Walk 1' 75 Tamarack Ave I I 2 6" 2�V!,f 11" I � t.T. ' 1 \\ \ \ \• \ ;' I` ` \I � � :J. \ 1 \ � .\ I I I I I I 1 1 I I I I 1 i Building C, Suite 75 i ( I I I I South Windsor, CT 06074 - -- - - ii 1 4- 0" 4'-11" 7'-0" 4'-8" T-1" 5'-3" 6'_6„ 3'-8" � 8'-1" L3 _11"b3'_6" �4'-4" �4'-2" � 4'-11" �2'-8"� �3'-0„� 4'_6" �2'-9'_-3"4'-11" ,4'-0" 1 9'-4" T- 11"2'-5" 4'-9" 2'-10" 4'-0" 1 1 �- I i REFLECTED CEILING 2' 1" PLAN C•7 C•2 A401 VESTIBULE NLARGEDPLANS 2 @ CASH WRAP Checked By: Checker A212 ENLARGED PLANS Job No: 06125.00 Al 02 n UPPER LEVEL LIGHTING PLAN 1/8" = 1'-00, C:\REVIT PROJECTS\South Windsor\125-base_local_kv.rvt 2/9/2007 1:26:04 PM GENERAL NOTES 1.WALL MOUNTED OUTLETS SHALL BE MOUNTED VERTICALLY 18 2 INCHES TO THE CENTER OF THE OUTLET ABOVE FINISHED FLOOR, 0 U U.O.N.OUTLETS LOCATED ABOVE COUNTERS ARE TO BE MOUNTED ° HORIZONTALLY AND CENTERED AT THE SPECIFIED HEIGHT, U.O.N. `m 2. ELECTRICAL RECEPTACLES WITHIN SIX FEET OF A SINK SHALL HAVE m GFI PROTECTION. OUTLETS SHALL BE SPACED PER REQUIREMENTS E OF NEC. m 3.ALL WALL MOUNTED TELEPHONE/DATA OUTLET LOCATIONS SHALL o BE 4 X 4 JUNCTION BOXES WITH SINGLE-GANG TRIM RINGS AND PULL 0 STRING TO CEILING PLENUM. rn 4.COORDINATE ALL TELEPHONE AND DATA SYSTEM POWER AND a DISTRIBUTION REQUIREMENTS WITH OWNER'S TELECOMMUNICATIONS U VENDORS. 5.ALL EQUIPMENT SHALL BE NEW AND LISTED BY AND BE APPROVED BY A TESTING LABORATORY AND SHALL BE INSTALLED AS PER INSTRUCTIONS INCLUDED IN THE LISTING AND LABELING. MATCH EXISTING TYPE AND FINISH WHERE APPLICABLE. 6. PROVIDE FIRE CAULKING AS REQUIRED TO MAINTAIN RATING AT ALL NEW PENETRATIONS THROUGH RATED PARTITIONS AND ENCLOSURES. 7. FURNISH ALL LABOR AND MATERIAL FOR A COMPLETE AND 121, OPERABLE ELECTRICAL SYSTEM.ALL LABOR AND MATERIAL SHALL BE o GUARANTEED FOR 12 MONTHS AFTER ACCEPTANCE. 'a �+ U y , o u O Pi 8. UPDATE ALL PANEL SCHEDULES TO REFLECT ALL CIRCUIT b 2 ; �I o N u a u vN �Lo CHANGES. LABEL ALL NEW DEVICES(LE. PROVIDE A COVER PLATE LABEL FOR EACH NEW ELECTRICAL OUTLET REFERRING TO THE d CIRCUIT AT THE PANEL). u o OUTLETS ATTACHED TO LADDER SPURPOSES ONLY. Uo ° 0 5>5 RACK,TYP. FOR BOTH SEE 9. RELEICTRICALL DRAWINGS PREPARED TECTURAL DRAWINGS ARE FOR BOY O HIERS FOR ADDITIONAL a w 5 VENDING MACHINE I INFORMATION AND CLARIFICATION. SECURITY KEYPAD10. INSTALL COVER PLATES OVER WALL _zTn,,.rM..,.-m.. „_-._� _-.�_-..,,-�,. �..�__ -.-, . -,,-.�-:�..r,�__. ,:,tr_�-,m.,rm �-,�vn.--, - ---��- - -------- - ----- - -- -- -- --- -- -.-- ES - ----- ---- ---- -- - -- - ---- -------- ---- ----- -- - --- - - . - - - - -- AND WIRES, INCLUDING POWER.COVER PLATEPENETRATIONS SHALL MATCH BL - - - - - - -- - - i Pc g - - �� i- I,- - h ' OUTLET AND ITC H PLATES.(WHITE IN BOH,ALMOND IN ALL OTHER --- z--z----- 2----z A z g Q_z �z tD Pc - LOCATIONS U.N.O. PC PR PC PR LP I I IF,. ® I % ,,/ GFI+44. OFFIC WORKROOM ssAFER 2 cL EMPLOYEE\C.OG113'GE SHOWER RM 11. INSTALL JUNCTION BOXES WHERE NOTED OR REQUIRED. FRAME MOUNTED I � JUNCTION BOXES FOR FIXTURES SHALL BE COORDINATED WITH SENSORMATIC TO BE Pc ® f\'� - FIXTURE VENDOR AND INSTALLER FOR FINAL CONNECTION. INSTALLED BY OWNER'S -�- =- LMICROWAVE OWN VENDOR z. _ _- zi Y 12.ALL MULTIPLE SWITCHES AND OUTLETS SHALL BE GANGED AND l C ,� ® - - ; I I r - - - - - - - - - - - -- � I I . : I l ©. ��aGFII+44 I FINISHED WITH ONE COVER PLATE U.O.N. _ _ _ + -- 13. COORDINATE(2)OUTLETS&(2)TEUDATA FLOOR LOCATIONS IN - ; FIELD FOR THULE KIOSK&MAP MACHINE WITH SEAN SALTER OF _ GRESS HALL -'-- --- - - - L.L. BEAN z STOCK ROOM @ 15- A F, HORIZ ORIENTED. L r 8 1/2" r - - - - - - -1 1- - - - ' - _ _ ; j�0" - M ELECTRICAL DEVICE LEGEND & SYMBOLS EN'S R M_ SYMBOL 00 ESTR 1i AP -z .. - ® \ :GFI+44 III (3)BIKE LIFT LOCATIONS, ' ( ► u RETURWCCST �I DESCRIPTION RETURNS —,' - III @1V-8 1l2"AFF HORIZ ORIENTED ryl 7 6T16TY CLST GFI Ii �,� - I WALL MOUNTED DUPLEX OUTLET KEEP CLEAR TO 12'6"WITH - - - - - - 220V POWER IN CLG,TYP. - ---- - I @ 15'-8 112"AFF, - - ❑ rr WALL MOUNTED TEUDATA JACKS HORIZ ORIENTED - Vic- - - - - i,i FLOOR OR CEILING MOUNTED DUPLEX OUTLET { CL z � -MCL ® _. _ - Pic 'v HOPPER TRAC OUTLET F ®ZN'S R �s O S - •\ GRAM I zI , _ OM; WALL MOUNTED QUADRUPLEX OUTLET ICL ✓ FOR SEASONAL REGISTERS \ I _ i 4 0 TO 6 0 AFF -----„ , „ r O v le DOOR BELL •>-� �-; , , %' � ,-- I `: .• --.__, \ i \ i - !� �E CL OFTV EAT 8 { - .Z . '! `r`' �,,,: -i' -= ` -- I ' ' 1© � %' FLR OR CLG MOUNTED TEUDATA OUTLET , ra ;'. !i GFI +44 i I � I I — J-BOX 2, rev -I �� ACCESS POINT, MAINTAINED HIGH ON WALL UNDER - i �\ STRUCTURE , L 1 I \ ,' 1 15' 8 1/2'AFF VERTICALLY ORIENTED, % \ . ;! 0 AIR MANAGEMENT y AM LOCATED DIRECTLY OVER CL OF STD - - - @ 15-8 1/2' AFF,VERTICALLY ORIENTED, %_41 , >; /` �, r LOCATED DIRECTLY OVER CL OF STD -- - -- a, i I' I B- LEGEND , @ 15'-8 1/2"AFF, HORIZ ORIENTED. _-_-.. ...____ _ @ 5-81/2 A HORIZ ORIENTED FL FLOOR MOUNTED SU TEXT CL E Wyt .. �,,;� '` -- - ^•^ ,;y� ' ;� _ " i I ILING MOUNTED ftAM , -- I c GFI GROUND FAULT CIRCUIT INTERRUPTOR ac..:, �.`, - _ 2 DOUBLE TEUDATA JACK ❑P = .i. I / � '•' n;'INSTALL OF FLOOR OF UPPER LEVEL IYC I @ 7'-0"AFF J AF VIDEO MONITORS V-0"AFF, // °eZ' 0" T LEGEND F > EQUIPMENT '' --- OUTLETS FOR MONITORS @ CL -- All, , / •� I-\ -� /%\' / --i / / PC OR POS UNIT Pc, UPS BIKE,SH ' P ,' _ 7 --- ---- DESK TELEPHONE ALL MOUNTED TELEPHONE 'I L-11_ !�=1 •.. `. i ,.i Jl..; \, /^;i, J ;I,LPJIN , ` r ,,,, > ,; /- i / / ZEBRA PRINTERS 'i -- ��„A --- - I I LASER PRINTER 7 SURFACE MOUNTED FF JUST 2 2 BETWEEN STUDS LP ------------- ABOVE BASE r ; , % / \� -I - FAX J __. @ 15'-8112"AFF, HORIZ ORIENTED EIFES FES rr _ .. .;.1 ff� 4I �_ - EN.,P, ;, , %"„%'';;,;,;,,,,,,, �',',;,,;,,/,•;' � ' VIDEO MONITORS,SIZE TBD, MOUNTED Y 0 @ 7,_0„AFF U.N.O. r - , . -.___--_, '- .. II 1 fir,-%. %;y '•';;',','';,'j �,, + ' ! ._.I: -'ti INSTALL OUTLETS WITHIN OPEN FLANGE OF COLUMN. CONTACT ARCHITECT I{ ORIENTATION DIFFERS FROM '� •� �,•'(j}'r., 1 IF COLUMN �.,•, i � PLAN,TYPICAL. i. N PC @ 15'-81/2"AFF, HORIZ ORIENTED —, i _.\ •_i :;�, j n I : I ,� KV 02.09.07 ISSUE FOR BID ---- t j I C. '`>.; : . .'( :` - .. -., .: ;i' ` No By Date Description 4. , \ \ L.L. can �FL - ... - e _ SAP '✓ .� \\ -.i \/ � " 1�,. � i � � ; ' - � i'I .� - �C � Iij '' ��i \ - � � I I� I D ES TO BE LOCATE '� I - . \ - ? DATA&POWER INSIDE CASH 2'-3' FROM CL OF DESK''`•,. MEN S FITTING ROOM < WRAP FOR SEASONAL UNIT IN ALL DIRECTIONS '` = @ 15'-8 112"AFF,VERTICALLY ORIENTED, � ' LOCATED DIRECTLY OVER CL OF STD J SALES AREA Po T 15'-8 1l2"AFF VERTICALLY ORIENTED, . ! ` � CASH F`�L FL •..- LOCATED DIRECTLY -- - ! --- �-- .\ > _. I .I I e2 PFL OVERCLOFSTD -II > i IL 2 V,� 2 PC i� �' „I `!� i I �,\ r` '` 'I _ -! ✓ _- �: ... -, I ✓ .ram '- FLZ, PC 'Fi- FAQ - (2) BOLLARDS BY GC, T F VFL _ FL P :o. rrSECURITY [� i CONDUIT RECESSED INTO L ` r 1 3C <.,(, Fi. ® r,2� os !KEYPAD _I CASH WRAP DEVICES 6'6"OFF ''` F e CONCRETE SLAB BY GC �. _- �' HE FACE OF THE BACK WALL ON A STUB OUT Pos -� 3'-10" I I M y„ -"FES P I / - WO EN'S FITTING ROOM `c r - - -: _ - - /@7 0"AFF - „ - T a - z r J, > > - C� s J f - 1- T - , I -©Z - _- -, i i ?T', / \ I I 5. PC , I \.... := CASH WRAP CLST i - I-'' ram❑ - _ , , - The Shops at Evergreen Walk �-�-m -- - 75Ta rack Ave I - -- - - -GFI - - - Building C, Suite 75 GFI -I- I- g _ _ ;+— - I _ _ - / n \ South Windsor, CT 06074 DEVICES ON BACK WALL OF,-j @16-81/2"AFF,VERTICALLY ORIENTED, I CASH WRAP@2'-6"AFF,TYP., I �/ DEVICE & EQUIPMENT LOCATE DIRECTLY OVER CL OF STD EXCEPT FOR TWO OUTLETSI FRAME MOUNTED SENSORMATIC TO BE FOR VIDEO MONITORS @ 7'-0"AFF (1) BOLLARD BY LL, INSTALLED BY OWNER'S OWN VENDOR /� CONDUIT RECESSED INTO PLAN l; C:Jni,RETE SLAn 3''r GC !;+, L n I I I I I I I QDVN Checked By: Checker F E D C.7 C.2 C B A Job No: 06125.00 Al 03 n Device Plan C:1RevitlSWindsor1125-base_local-sh(Recovery).rvt 2/9/2007 12:39:22 PM Cl C . . U84 N N a . U O . 0 Q I Ut � a1 9 N E m N co Q N M 'C a 0 U TEUCOM RMU o v F I � V o _ a-< o u V ... , .r,... r... - bw 0 r_ , ...,.. -\_ .,. nx.,t. . ..,:- .., ,,>.. ".,, .,.e?-':S. _ 2' - (.' .,. e a, ...,, i•: ,t - at„J'. 7 J trf ( ,-. @.... . s, �. VL 'i'.. .nr. at k ,., hd. .. ,. ::.._t: M LL , N. _ d ...w,. . ,. .: 'tar .._..rta .,. .. `ti R 4.. , ..!'., .,: ». , . : E d,*.. C '.J,J.; d .w,.. .-1,,r 4. - 1� tir , n _ _ay i ,.. ,_ �., _. _ _ .� rvi .,,: , ., ' , a .,... . ...1-a. .- <I-. +r , "i, r.. , 6:4i,_ V.. V: .1 y SJ_... -v .- ,. ,A t„ ,.R'4... . n. .. .. �. 'S ,• r-, _r. .. . .{{_ , .. `i .:r:�,: +..:., r i.. -S. t- _f/,-:= rrrt Cq .-_,.. n,' .. ., z , ,. . _.. r,i/_.r, .. ,} _„_. r' '`i . .7: f -_:.o. _,f a. .. a•; :gis a.... <.,:+•X 1 4.. J 09_ ., .r ,,.. :yC,. ... n^.S,. _..,... .... [ , , E. ,. _,.._ __�, . . _ M. . , .,. .,. . _.., e..-.y .n k': Y .. _,, o- .:t-,.,c � S. t l ,'Y .,F".,T"� +� vl a ,.iU, ,. ., : :Y }. ,al' i, k.?i + 14 „ r�, suv. v `rS1, .�`, r,- c, t ,L» I.4. +, C a`} Z H n.. rtz; Y.,:. .,4. -...r ,,�.._ ,-. rd-, , ..-„}� ,,. ._,.. ..,mac♦ r. ... .. \_..,- .. . . ,. - . s.. . ,,K-, zw r s: a"" ,: ant:-. � pLbY�EL UNG-•t -J<. -J _ .,. ., + _ _ ih.1.k . '4., i - . .r. _, ,. .t.�_..-„ _ a13' .>: 3 ,a.. 5:. .. qr. b ,.,, L .L, r. •S •,,. � : w.. r M 1 O _, .r. ,.,�.,. .>.. ,7 ,.. .! •4`.' f „e: v r. r", P.,.,, .d . , .{ r:. a rr- t, - _ A .s (:: u c :, ,, . .v r . . ,, 3. .r-, : .< . .,.-.,. i _. '1 {' r._.r4,a,. 'Y.. t e. __,r >_ i >.., �` ,,.I- ::� 1: -h't _ „ T_..5 ,., C 1. -.. 3.. .k, r } a _ ! ,.-:. )J 't ... _ ... 6,..hs e5 - �.. .. ,s ,. -, r :,,-. S. �. ,rF>Ce - ", O. .,O v ..r;'a-. n _ r.v cr } t rrF - , J.. _ ,Nt ,� r _ , o. ..T. .., ,. 'u r .. l J.- 'f.. t.,. 5'e, ,. t .� ... .. .. >r c _... ,�- .2 ... ri*.. _ a_ 1 ., F ._ .. F ._1.nx :. r r. .�., .. ur. ,. , . Ss ... -: '„ ' t" ++,: ,.o.... N t` .. ,. ._..h., „ . . J.. Y.. f r ,: ,. a. .%co- .k.. -. "n•. i.. .,_ ., t ,.- 3.-i,t -v,. , -1'. r,:. . r !� - :u .. d'r r .. , .. ,.. , .,-. .< <. ,-„1 e _� - .. ,.. a '-, 4 tr..J n.v. n - u...._ v, _, , .. ' ,.:F' .t '.a _ 1 .5. n 1P „� U h x r-k„ .,..+ t. J , n, i rs. . 4 a -.5 _h :, I< ,-b L -c .. .. J ( -_,. ".:,.. i Lr1 1 4t , :- OFFICE WORK ROOM SAFE RM 4 C . -,a r _, _.., 2 _ _4S5 A..E , ,... ,. +b', a' F. v>:-r.r, .,: .-.6' .35' }. _. .._ • w'l_ 5 C.-..:.r »r_ :.t, n.: 1,: f J 2. f: ,,LS r•(.. E ,-< 1] r. uP ,R } -. JL_ .. _ ai.,i<,a '., .. , -t 4 x .._. l ,i 3,.. -.i..y s J. :. t.`,4rz . ,.. ': t'.. :,:off r , , 4=�` :.wM1,..:, v ..1. .,Y� .. .1, .i. - .. ., -..<. ,w `-t,J ,. �., ,. o _ 'i' .L. F .l'.,., f, Alt.[ _ M. J t ,L t„i4., o-,,,.,3 ,. 4- -rY _ I, _,.a. U.. :, .._. _ .,s-.. .. ., .* S' _ ._r_,. F :. s.f ham., _a �,� ?C --r I m . . _5 v^. .. .. �¢. >, .,.:. r. .. :.. „ .-..�,. ra .i _ .,t, es-..,., -vim-_ t i , :ti ,e- i. -,tA. O ,7. _'r,-�,'a± r.. ]. `,7_' S. 4_ '$t t et:. Ic+ v 1. t 1 z,t as +_,,y��,,yy L ,C' C' v ' ;'.; .. ? e , n .., - .. , .,.'..',r 'S .., .:' ;:._% - II,^, C . uwS, , ..Td ..wT, t"' . ,+ 7,F .-.crA s Y'i., b $„r,.n, .`S ,�U1'4l: a', :>,� S5n, o r r„ I I I I NS 3_,. .r ,_-•-n,-,n y1...-,._ .3 ,. er. ..>. ,r _ �.r.d�.< r 0 , s.J ..,,,....;.r., 4 ,T... .. t. s i .\:ca=. v,. 3} e v? t. .'L,� --F , h'S c .._i;4 `•af It ,a i _ _-, , ',:..., . .. , ,- ,.e.r�.» c: 4, ..L - 4 r ,:,;,. 1 L i ..ry ,...,, 3.. �+' n 5 _,. i^ .t ,:,: . . i- , ..,. a .._ nn. , „ , -;:: •__=. .. .. 1 { ,. r t :t 4•. .&r .. ,_� _.t...�! . t..__ .. ., .. , � b ;-', ...,r � ,fr;r. ,.<.>f.. . ,.-Its, '$ .. , ..n fi`, .x }i . _ .: . .b d?S 1 ._ ,,r. .>•� •, c+ - r. Sr, v_ n..l..c v -. _ u. C ..:,tc �� :l .., a 1t.-, \+ . ...?, .. 2v ., ,_ << u. ? S > l+ r. . 'v:. ":^, .. .L , -A. , a �.: ". r V] H_. . E:.�.._._ t ...t . ,. t,-. r .0 _�.. _ a. LS ... r. t. vim, ..D -r!a... RJ f. n .. s.f ' Y. ,.-. ,,, ,n. .,_ c f O r �. __ ,<•-, r..S vu. 4, S a.Y 'u-, { a t a. '+, , Y 1 :,,. J "t ._. . h .. .. 1 C. „ .!' _ .A. 4a 4t •i w K ln�.. Fx tS .,k � YS ti r rf i , v ,ds i _•,__. ..+� M _t. _D•s •-yx,•: :4.. I l;1`r V „�...>.., rS,J I J'. F .,?l ,SYJ�.. ..ti», '-1 4,s:`- i-t/I L. `X ,_ r. . -..''1. , L� t. ..n.4-,t _ h ...� .v » �.. ,� 4,_ ._ t..- � . t}."4JC', .. .arr'_ 1>n._- 'r -x ..-3f. , � .r7,. _ . . 1 .Y_ ',". I I I I I I - 11���' ._� _.. r. a=J. __. 6. -� �. _�J, , ... �.>v . ti.,.'=,.. ..,:.� ,=,r .a .,~ _„� _ . .., �� r .,,. ,_ L._ r �: .�.,. _.-. ,_� u, _ e ,a.,, ,.. .. _ CC 01 STAINED C N/+RETE � o � r, �r_.�Sk ..._. .5- , .-,r,'4,h�i _ _. R) '•�' xt'_r _. 6..,,t,. ..., „,t�f:' .� •r, ' ,.. X 4 L. t ra,,,:.s s+a ,.�,If.. .,..F ... .,s _.L S ,. ,s ,n a .+, t.t+a, I C' \.r I . ti s _ { _._ ., J, f .'4 t ..t .. 'N'spa' }. ^rrt ' .,,c ,.0 r- .. .,':• x_ -.:,. a 1 _. ... .',TYC drx r _ ._ _. ti.. .< .,,_- _.._... �. 1 .... ,. n.: .,.:. ._.. ... t , . . . ��a.- ,. r ,,r .r",.,-. „J .:.. k4, 'a :.-;• ✓.,.. , r ��,. �,.. - _., .,. v �_, . ,. , L>, ,� ^ , .. � ,,�, , ., _.z 1 „ � �-va P 02 P 02 P 02 C+w x�2�.� ..`.J•P - t .. . , ,s r. ..N... ;>.. .. -' ,I?., <, " _:,�f,. ,"1" . a a -rS!' d.. _A.. :"n o-.,. tt- aw,, .4, r I,.r., L c .,+, ,-L« _ ✓,, S ¢� ,M1 ,, :. S -� ,rc.n a, 'r,. ,nl .. ,'z ., v_..x„ _L .J: t.. .T._ .c•- ,c' r..+ ._ _ t [ 1 : S� �-T, ,,,_, -.> - I �+ 0.l ui F fz... �-,, .�.... M,v .:.., . .•.:- . , :r-. r,. e4; „ 1. t .� L u x ,., r. 3i Y4... C- - x a>,a 1:. ..la, „l.$tp5 -c_,.,v Cl, 02 1 fA r ».. � �± , J, .t .SY 5. '$, x.- ...r 1; 'ti : „k, a 4,4, r _ i-. M I A�03 Id'^,-A: .. r,c-f•,. .� 4'.,. T. �L.n , u5 1•'. r. k+'.r., L-1J vRR• i 1 .d .. ,• , nn.,r+o+. ,f .,ti - v ?,.,-A , t "r..,. -,' r , zv'-; -•1': ,t :,S'. ..aV'�'nfi 1 +:. . :}. _ .._._, ,><-a. ,Yo' ..[.: ... _.,_ , :.- :-in., �',.,Y ,.. i' ,r[s .:• . •L.5 -.,.- +,..�,Y°x ': _ .? , ...>: e- . -•"'`-: fi .L r r :.1:- ...v - Y. Lt,,... „! . ,-fi"..r2- ;.:.e{ 4 s. n.,.:'M 15 �. r. .:.. a,,. -r -5, c ... S i.. ,. _. " sn,•.>, ,,..,.4ro:.t, ':.r 1:1 = a tg.� .�..F, J .. , . ... ..J, F,.k ,.,,. ., 1 r ,. .FV-c..r.f ,. ..,\.<.A ,t rrc_.. .. S ,. i ,r--...... ,..}sn r Y. a. r.', t L. .. r �::,i e....a ,: ,`xt 1 . .. ,is J. _ <.e,- ,:r.>_.a 1. i .t, ..rr . v sr „ . - -.9. . _ . ,.<1„,,.,,, r" t. a ...,,,. _ tr ,1 -'{._ '( 1 .a$. Yi,}!.."- -i.+. .ax?'r,.a.: -_ _. 1 s .. ,. _,'it- .. � sv_ 3S ::rYr,, 1 F 1. +'C, < 1 ," .... -c ,. ... ?. yr r -,. - .,r ..,' :,,t „,t+. - 4 AN", "�' t_ r .l, ev- ....,-�.a.. l .1... -in„ S `.g. _p� , r . 1�w .. ,... .r .,w ..:,4.,.,. >. .., o,. .. 1. it ..Y:,.a2. ,t_ J - .:1 b__.., 1 1 •f i 2'T'. ? a',.a S.,r ,*,i4:}Hr I.0. ., . .r3:. . .�.r .. ,._x.. ._-u +,. .:'? _ i. ,w•_. ... Y.. ,._., _ .,T' v.ux..5•. . .- n .,,.,,�„ c.k, a',. ,. ,.._ .+r Y, Y.-, a . , n,. ._. -� t_ l i -.�i .I. .. i. a F-,r . d._ r :'!'. ... v ]_.. e Y „ t ,* „ .,_ .t,> .- „ .. n C,.. : - F , t t { k. r.- -.r`N _. n.. +r f`"3,. �,. .. .. .:. ._ -+ .-. tt{{ c _,_ ..,. w , ,_ 1;�Y v ...,.i'. .Lw tik r... .._+r'_ -...y., £., '_ ? n '1 r'r - ,-r' •ir _ -„ L4s _ -t.,.__r.,♦ r.r ,,,....,t... ,�__ 14.- ,.-.Lrf ,.r r5a< K.a r.,. cl. , . ,. _. .,--•,_.}... .,„, ,. r< 1 5',,,, .a-ta. 'I&t.. r a, ,., 3 ,nr ., �. V. .e,. ,., s "}', a."r .. ...t 4 . , , 4. •: ::v t' t c.i(: _, _.L. T 1 r _-- �_ A. xk Y r;rna. < .r ,:3. s'C _..u-• Cz ., t ,.,c ,. ,_ . . , 1,.{,, t ,,.v:. . r , r . v.:>.. .. .r.. xx. rr .',- o-.. 2 -F. rr.%'r is •;Y .., ,_ _. n. . ,,.. - ,a5: i;^ ,r hrL-.. ,s 3 ,- , ,..:� £. -.1 „n'. ' _. 1 z, F t +n, s- t t> _7- 4v I .x r_,». __ n t.,r I,._ 1 ,..y - ..,`,It-:r ",<- • _.,,.»_. r r, -v,. .. k. h . ,4...:._ ,r,( $ ,ti,. . ._ 4. w.. , _t _r v gg �„'., _I _ l r ... k'. is ,t x,,J { 4 .. va ,. _.. 1.., C C ..e -a: b. tK. ,...t , '.:+ . 'r`,.-a - .`2 . .. ... . ,. R..r L uf7 -. y,:... ii5. -x,. >.: I 1 s--r>+ m`k .e- 5 a,. h.._ i,.xl t ..,r ,..,, .. N:. H.. fi ,�. 3._„u.., Y., .,,.-s, nti ?, � a .. J :}._a , :. �._ n }: _,1 - I .. sd -. ..-�_. -. .. rh. .,e. . .:_ .,:, � _. r .e . .S ... ,. �.,, 5n,.. . {•a- . _2,. �., ... . .. 1. eS� :a- _x- .a:.. ,_K ,.t-. , r..il ) 6 3 J:,,x }: _ .'�•.. a. Y-' 1 I v �, i,. t_ 3. it ..r , 'J -...✓-, lat ,>' A _ .P r.., <_-.- .,},.. r J� -:,,,. +., •t.. 1 _a .t r 4 > - J... �.. l f•L._.. r,... -d :v . . rC. ..r . _ _ :,. .. it'. , r _t � ..-. 1. .. ... ,.: 5, ,/. K-a_ e n ..V' v _. e i J ..:. ,. 0. -n eC. , L .., ia..v:.. .2, a.J r:,:w, t �i'ry � - 44. - i»y,{ .,.n. � e ..i. 1 h. .._.,.. S _ _. _ _ ,.. . . ..r t ..[,<�+ ,. . aM1 ..7 bM1 .r,. 'n .4 . , .:s:. n L'� .,.� 6. .r .. ..., 1. .2r� 3.4 "a 5 S� 9 i.. -Ss .„ ry ,Y. . , ._r , ..-n _ ?IY} it < s „_ vt L I, 't f _,. L''., I r ,.r_.. _.iV1 r,� f5 ° aIIV 1 3r._ "::f 5 ... w, _ u _ , ., _ � ♦-. , . f . Yr, F' ,x :r, ... ., _ m ,-e. . I . - � : . ,., Y. . - ,...._. ,r a:, s S'--. _.. _ h 1 I I I I _I_ +t ,.' ._ �r 4r,.S _ -.. :, , .,u .-.a ,_„ ,1., �. . Y l r > yy r 3,. r._:- �/••+�:�. 't Hr. ,•s: 'i.,.: ,.�,_ �' , .<. m .L,: 1 V. r,.. ... .., rr I ,:+ +,. l 4 ,c,n _ �',..,^> a _- 7ua ,�._--_„ , W t„ e3. , Ma _ .aS,;, (R:�? , r .1}. _i Y, 4 i, .. n /. .r � 1 [ Tv rl 7_. .' - k•4. � .,., n'a .. � w :, , , _,•,.._, :..., L Aw ,u•. r „ __ .. ._ _..1 3kr..,'xa, _ .__ar�. 4•.., 'c .. .r` •.✓ :� ., r .,.. � ,... Y .5: L t� ,r.+" `5,.. ..r. .S t>.. , x�io ..�.. •, ,.�, _ _ . : . R .3 _v ..,,, J � t- A r,r.. ..,.. ..1.._, �5k+ h LAif, _..�. :.,n .. .+-. .iF.. :.,.. :.�."' - `J , . _ z ._ _ x T CC 02S LE: . . .� . . ., . �r , _ .,w Ir. .. ._J _- , , . .. r , . . . , .. , :: rl ,, .a f. ;I � _r r :z.. ., �`,:.r. EA D CONCRETE tl. A _ ,.<) .. .. .. ,r r f ,.n „'a}4 r(.r �. i:r. ,. ,?, r- .h Y .. ., ,.ss., �. , _.N'e .-c.xv ,-.:..N ,� ,r. rJ. ,}.c Jt (....(.R.. 1 t ,. ) ..J �,,. .. _ .. . vn.. .'h. ...v r, a- _: v ., s. _ 2f r_v. 3 ,- 1, i' 6a+' -:R(•,:: - lf... r _. _♦ft{t1,. •. - +r-n -t.,r.. , ,r )5 ,f .Y , v J v.- 1 ,.«Y '' .. 1 - Y^ „ ,. c C.. I- , µ,; I I I I I ... ,ro... e: t,}_-,. r•...,rsi :,+.., , �' -,..t ,t,,.1...._.,..,.>, 6 .-.� _. iP. .f r.., ,_ . ,_.r ..,. ..., � _. .. :, , .z.. � "1- _ •1 . . .. ,. ,. - <.n. Z 3. ..... ... end_ _., _.. \ .. n . .. <,�. •�. , .,�_ ., ,.. .._, .. ..- 4. ,Tr Y,•. v r ,. v , _f..._ ( t .. ._. .v ..... ..f S.t.-tv 4.. .r` ,.1 }'S�.: :'r.L.v n: �:. 7 [ L J 6 _. G r ,Z,r: _..t , .v i.v _ ->_:-., ,. r r v. .i Y r, tv i'- Ai t k.:,a ;.L.`a�,•7 , ., ._ v . ... .. .. .c _ , - . , . ,. ai a . .-:__ ,.. . : -�: ,:. , :, _ :., '.._L Jr- 1` :. .. t , , v r_- 4e•.x .."6.: . .v. nw..,ov.x .. _r J: our r ,.n+ xw •. . _ _ .,r n_-, t l _, .e, a.,-, :�. . n.. :r. yr .: � a4. �t� 1' t,a d v .. I' ., r' e a a Y _. __A .; , v. 4 :_c , r. y. a 'vc 4" - .ne, ] ,. ... -r ,. .a.:•c 1fa... '-iF. 54. .. _ .< .. a i a _ ) d .-•. ., , _. , .. .)� f w. a . . r-.,. n.. } \,. A. h ,. A ( ) -:'. .- .. , k _ _ n., 'f _t-. '� :. 1 . .- .. ., £J t_ a - r ... r , _r _:2 Y r .Y _ +. , _. _. :, � ,Y. .Y. a ,d r r { 1. ., o , -, y , , � y}) , .... .J J, :f : . .,i:. . .y t ., r , . , .. y : . ., i.L 1n, d• r a l .. , a Y 1-<,,! I ., d ,. , , J... f. a J' f a '- , -v , ._ L . �, F _ ti,. :, r.:,,. . . �fA.- L - .,, x , .•a ,.. t V¢, r J . .4 ,.. T'� k . . .. , .. .. . J:. - .. s , { cx', r r. . .: ~,Y .. , ,n. , 1-. .T ,,. r .. Yt. ... r, ,. a d ,. Y:. ,.. .. ,. � .. _ ?In , ... 4 � eS v, _ _n... +3: .: .., L. 't,., j'I a -" , r r r- s 1 _ a� 1 r t -=, .c_ ix r , - .Y t}:- 1 r ill:.V ... r, h_ .>.. , -'._ v •i %.. fi .., , ,ka ... .�. „ _ « ., ,:.. :. _ lw.. ._ s ,,.[ „rx..<:. .'1'- .L r Y,. .. :- k., .l J.., a ,. . .,.. , �_.. _ ,. . n. +. ., , -a, _ - , .. _ .,.,__,-r..r-,- .E ,vk: .r . a_ _ , I. a . . / c :..e . ,. .. 1: rti t:_ 4- . ... ., ..Y �., ,.. ,. .,.r.... ,> ._..'k r . c ry.l.,, r$ . .,... ,x. _r.ra .-> _ 'L r ri ... _, 4„ . . - u� ,. r .s ... .. :-: e -_ S _ ..-, a- 5 ' i t ,.�. _. � F I.'�.IS. _ _.v_-iLG r .,{ e - !. _ a r Y .-_ .S. 1 "53 , . � { „ i _,. ., L. .., , .1 -,. .� L: ,. 4 _ v..l S 11 ,s1t.: fh ''Y:. Iv, ., , i ,. M1 Y. .__ } \ ., ,- n , � ,.{ /...0 F .♦ ,.,t � , 7'..rssil ,.., r t. v., .. I -. r c :r,.,. . t.J ,. ... v Y ... _ r L - w .�., ! ra : • v ,. _ ,v C . 3a ___.i.> a� � v -. � , 3' t- , _ , `vn. .i'S.,.. _: r_ ]f� t ., .-, _- .. V._ r, -,J _ .. ,, s _,._ s. t. , ..-, a +t,. n .S. .F ,.1, w i- ..x.. . ,. , I. , < .. �.'c ,,r... -. ..4' Y .r _ > , ,., , 7' <f) < _., . ,� Y.,. ',. a r, ., , <, ,. J_.. .e ...c f, 1_ 17 n.i . v J ._ -...+� : ,, _ -{n, .4 e J,.t' .(h^ er:: . f , -, _-} , 3 _r�: - .,l , } . r , i lw 4. , , -� Y .Y ,, r V ,. , A � a 'U. , E..>. L Je -... 11 tYsc : 4' r M1, x -, .. t. _ F. _ ,. 4 .:'. . , >: :. : Ix „�. 6. 3 ,. ,- ,., r •,<� o- ,C � J ,:� x C .,s t t.,.r § 'i �`tr ..,.' M: t x. ,a-, x i n. t-. 0., k �. „ti,._ a43, .,.-T---__ ,L I ..J '•`ricT. y3. U:.,.,.. t -4. ..U-.Pv I. .,(^: 'S - i_ i. '{. _rz=,a+.Y L 4 -t,.,. ��` _rl:, ..v-,l- _, .. ''�. rya a ;b, c. e•..v Y_l. .,, : ., rs ry., ,v_ - e. -. ., ..r ,. •v,: r .... ."1 ra 1 , e 1. } i. 2 ,i'?( �1.. .,'l,'.c , ,n G I r : i. , tc ...6 .f.. , "ti _ u ... t 'n ."`. '.,\.. ,.. .; >.. _ -. .. 1 , _ ,..° t' 1,... 1.:�• 'l.a. _ .- . t csvl Y , t Z ,, .. r :Jzf c, _ 3_ , rt . . c .. L. :, _:,_,:r--_ ,..' .. i L .-:� - :_ tr:, .:a - h Y , �.4F , Y. v a. , IvS. .. „vi .. �., F 4 . :. .... ��` ..w. .. .....,. . .. . ,-: r, ,,, , .. _-,.,. ,. F a -.t,-, ....4, J S. v'S• '4' -A ,_ r. r. . -v+r? .u. _ .:. S._ .s , r..-_, __'.. k.... ... . .,v _ ,. . , „ 4.:- tt r .ry :. ,,. . r, a.. k'y s . ln. �4'cW,. x y1�:._n } , J. `•, .. .t� - :1 _ 'li.. -t sa _c .. .. .3 ,.. T. . .L. .. -.. T _ �_ „}' ./ .... _j. '''>[ ,,fr 1 ::f_ ,L ._$, i`, i<., ._. S. . ,. ^t.,. c _v. , <. :. ! .. r r A,. 5 a. b 5��.. , , r INl `SI .. irk _ . .., u t v e. ». _ -. .2. ...-y wi 3 - o- - -_• --. _m , vtl.. a M1_, ,t ...1 • , • • - , „ n _ Y,^ ,. , I, r , ,v ri:, 1 J , kr +S _.__ ... , -, �;"_ ...j 'S 'rtl•, a _._:.V. } f -,M� v�'_ f,v r, , ,. ,.rm--: n S , r ✓• ..J a , r r. , 4. Y a..__. , „- , ." , ! i .}' a y ,l v - M1 _ tf _ _ 1,.Y,. h ,, , r L{ .. n..f a.v- .-A , ., _ r __. . vai. f 12.:=1. ._ w :M .. .. a :, r-. n,. d. v .... ., .., IV: -., f SC , a .. e, � r "r. _ l.. _ -,.. -. r .-., r . ,t .. n sa 1 r __ �.i .... .. _ 5 , ,. .. .. t ,,, r. a � r r . . . ._. � ._:..,....: .,. ..,. .�i r< a' f: �r' -•-, t , YY _ _ -,. .... ,. .: -., . ...-.. , e. fY f ,.. ,. .... , 1 . .. ._}.. .. ,. $ , r. . .. F .. .. .. "%i - r,n 5.-v . 1 :i.�s . . , .. », I wr _ . ,� � �r _,L , ,, . rA, . . - ,., � _ . , ,., ., _ .� ,. CPT 01 PET .. ... ... ,.._ .., u a .r . . ... .,_, . . �� , ,. , ._ . ... , .... , . . .,_ _� _ _ •,..1, _ ._- '4 . .1 -.rtl. Ik ,1.,, CAR n 1 _L. `1 , _-L.J 1 _rn.1. ., 1 „v L ,"t , r W:, , ..0 ,- .... , 4.,4: 1 ,_r _„i.. :. ,L $ Y Y.J,- ,3-u A u .C3 1 t t•. "`1 .. -,:t•� i Y . r r � _ _. , •: f., .. , -_ :r a` .. './" 4 ,a F } ,,'..,. � �„ t._ (-a 1 _ -. , ,. •nl ♦ t , _..._r , x n U u 1 tt w� �. A f ,-. .. �.. 14 .. .,- Y .F e.a.., r. .v. ,. __+., rc 'i __ 1 _ �, : ,.. h ,u. :: C-,. , ". .. .�"n:. ., .vl .. l ,. ., ��n', .,. .. ,. 4. 5. r3. Y . _4.k_ , -: .. a. ,ti* L. _ v _ x .: :, -. ,. .. . _ i. . e:. ,x e _i^-r r dM1 .. , ,V'. _ ,. ra,. ,.4... _ .f { �- a -T r . . t .,, s. ', , < I. ,._ .d. S 1. ,b:. ( t , Y, 37 l rl ♦.� iF �� tRil ,. �., , r , �. Y.. , ,_ ., RL URNS CLST_ , , _ z . - , a.. „r. . . , . .. _. ,._ . .., w ., :,,.: _ , <. , �. .. a ,,- , 7 . . i , «_t .. .. . .. - :' ,.. . , -r.., r ... .,..- .. r . � J. .. ... ., ..-r.:_ .�f ..x -'v,.n 2-t. [r ."i_ . . ,,, GRESS HALL a d.A ._ i,.. � t _ d, : a. . .t _ .t _ ,. ., Yr. _r'!• ,+G . ':�. ,. v. : ,l r ..._ t ._ .. „3 . ...G-:. Nx t. , :3.._ 4 r .r. ..M a f" 1.<. .. , .�.. ':;i+ .. a r. , ,.a.l _ .- _. _ ,.. .. _. c :. ,.r .. .,..:. ., _ ,.. V. e 3. _ , ,. .. _. . ., f at.. .-".., - r'y. ...., .r ., t..• ., L ,. .. .: , .,<... r ,. _ r . 60 / .5.._L n , "4 _ , ,. v L+ ,. n , ... .. t. , ,.- < , r _= e ,. .w _. .,v, }n.,. .,. r- , !. _ ,. h � ,... .� �'. ,. r `-oh"Ta .... ., .. .. f rd.. v Y r-. ,. ., l _ 2 , r .., .� c - .v -v _ , n YY .., m 1< I , - ._ 'c, d.-. .,. � v ., f - �} a ., r t. t,'L'ir c , Lv}.. -S'S. , _0 .t cF. - _ -, 4, .. .-,. LL , ,.r , rt• _ . . ,_r , : a t . r. _ , .. _ .r' • r - .. .v , x -.a' _1% b� 4.'1 .. _ , Y n^Ir. . - e ._ ,. .rT 7 , .I .: s.. _ A i. , :+. ..+ .Y, h n .�> :. .. J _c s .Gf"`.. i... r Ye n -. . .. r. ,. .. ,. . . ., .. -. .. .. at ! _ .1. _. _.. �". C'r`'l. ,.,, s _ .. . . c . ., ..=h a.� , �+. 4,.. .. � s J, -.-._ n.. ,.. ,i, „ .� __ i .i. i .r „_ ,- ,".. _7, _ i . t. v.. �. a >z,. s,_-,rt _ r..,, s ..< _ L 7. ..n...3 ,. f e .__. 1 :. A ."-,,, .c -'} .. , iz `: ...<.. } ,, +. .f 'd Y , S a kr ,�:.- -. ._ �.. a5 .t y, tit i ,. _.... ,7k ..Y, J.. , _ ,...s: 't _,-. , v ,.: rv. ..Lrs ,.. ,c .."[. i 4.Sr. ... .. ,. TU,- ,. ,, . ., e3 -d�t, r J , .-. , ....... .r - , ,_. :_ , r L. , ,. ee . .. , .. , 1 ,L x„ i Y`i ry 1 �. .. - -, i.... f n : �.. r '.'. , .a , . .rF �. -,. . _,, ._nee. • ,-a :,-t: :r. , .., ,+, , } ,•. t :vY .. v _ .. . , _ .. R ,. . . ._ : , ,Y „J 1. u. .a „ s :: , ..r-11 , F .. F s a. .: . .x1 Y-`' ,✓? .. � Y. :1 .. c ..... _..`}Y._.,,t., �,.... „o.. _ _S _c:3-,. a : .x, ., .'c ': rx _ -.G... � t.. ,,, , _r. c. .,.R. .. .. . .,. ,. .. ,.r_ ,., w .,; �` )'�Y:L.. £{ ¢ J .t ..>.� {..a��a J•�,^, s a -� t u d,. - CC 0� ,a, Lt ..t w." :, ram : >.P,'. ... .-.-•r,.<. -...-..... x 'v ,k . 1, ter_ pp.7. n:'cv�,.. t't'+,.� c ....-, ,.-z,-..- .> , . ,: .,k_ .,- :,?+L. v:, :i. - ay. I k. 4 ,.c. ,..A -.,vy- :�Z. ,w>iv } �s.+ v..z .. � ,.5.. y <. � x,.,,,tv:-, w..An! �F i,. r••SS .,,. ..;',n..hr . ,.-:-. <'.^. - :v r 4 ? - - w x .: , .,STd.CK.Rd(!M .a , N :. : _. - -, -- � w 11 .JA}',�,J, '- '_.....,..-d 3 v .-«:x,a r1'"u..�.�r- :G.. t4_> , kP,°,w.,`t6 ✓r.a• .�' ,f7 ty y?-. . y .d,, 5. .,,. 4 bryV: 't::., v_ ., hYv x ._ % ,4 .e, , .. n-...:'. - nn}.� V 5' sl__? '' n' , +.. .1. .:.-_, r .._. ,ri. '4�Vn .•:i•, ..,, ¢;,f,= "•R ,.. r a ..a a r _, .1._ tl'. . >.... _. r a , {. - .. .rc•= t. ..a,,..-., ->,- rr-h <.-. .. _£ .h .n,sr...n,..v ,.;..: f... ... .r�. �. . .,,.1t§ ,- -. ,,. .. :,.,Y .n' -P` .c - Inly,..- �' k '+, 9 _ _K ,.ti,,'t ._ .. "Y i. .,.ay. .,, . _ Y �S: •G.. r . ),t... .,, ,,. .-c,r ) .d r,�. ,.. - '. < - t*J.iP1:' ,}: .... d x .. ,?.. as ♦ _..y: _. .u. r'.., ,k. a#• , �. L S£. .:.. .4.._ 't' - �`',71r. _ v< ;L , tr y .. r $ tn. 4 f. S . ._,- -,.a_. .. _.": 1_a T'1'i:u. ,1 1'. - ,h tl .,: .,:. ~'r.1 t T ,tm.. -4ti ...„h '� 4 t. e. -n,._. __ u .r ,_a-2 ,.>L'3.._.:, .t , .�i is ,. , t f w. .,...5: CPT 02 CARPET ,. :,.. .-.,> r 1r.. ... c_ , . v.. - _, _ .N _ ;1 f 3 ._s „ :t._.. ,.1 a .,L., - ,.. _ ..r . . ,>a . k l , 'i; ,.t n . -.i.3Y. Y_,,, n• .'S ,&. r n-.:a . P ,I,,/i.- , hn3. tun.,.,.1. . .,. .. - ,,-,..s. ., h.•:x .- .L+- / -a r t +r r, :a ' ,,,k --r c "h it. , lAirt .r. .jj. Lv" -.-,t .. -5 1 t,_ r„ ,:+.:�,n. .r,; -.....laSu 7 .,.,. , _ _t,,. ,^r'N'S::J+ t.. L. :' [�r1° l_....,r. aYT '<.3. v-N,...9 .: Y_.. :,,f L _,. ,2- :`-'✓ F E,,... `-_ T ... ,.-x Y 1. ,. .r:K -. _ 4 f t. cs, .r... j .. l E , •f a, - -5, _, .. TY r _.. ... '1 h.. �,C , .:? IM r Y.L t `F. a }' y} ,.xc...-,I ..._. _ c.. _ `.>,. j.. ..5."d'•:a,s ..,rs .., .] _. , -.,3: ',3.e5 5,. ..__ :c.. .:rn__ r .. f ,.•f . : ',c:,s ._d. -'a rNw i9. ru5..,..�.:c-1£'�`. ,�: .".s. . xr... ::.r^, r. i ..3:,'t7'Ir-J.^,_-.,7 ' Y�,+>,J.>s ..+^, .,.'R�.. i _v.J. : - t - .rd. .s=.- - ,1. .«1, ® _ 'L', .,. _.{ir rru? s .lw.l• _f, - Mrv. , ,.,.a __. ,- Srs ,!- e [ d i.- . _yl' - • _ ..x ya _ _ ,,r`t,: t.- ,:.s„ a 1 n,q '�. 1"`v. > rtiM. - ::, "{, .,,_,. _ ..410 3{ < �. _ .++.v.,._ .Ei-+. K L,.. e"-". r>,c:-_. ,.65,x ..7`,..3. -,,.- _,:l` - , -tXr tom' S ..t.y n2 v;"h tl�t•4:` r .t „C<,a3-L+ _ ,YS rJ n,Y,)_N .0 .0 r•. rA.ti s`<L !7',*`-F Stir .„ i. _ _ _ .x>L..r+.+r Y..sl t 7 s z, 'v• 51,, SSY 6. t ,t ., rl Fv - , Ho-::4n .'vim ..#, i i.- c:, 2.r,tq, q. ,.�. - .1 ,I;: 1 1 ` s •1 ,>•nl:.,. n'Y .e r s1, J s a _.. .• . : - _t.,, T 5 9 -4' E-. A.r}:',•�, t.. .:.)1, '.n=. -' "T-a .Jn ,T.: { A. "if, S: TI..R.. t' ` r rr_s _> „�... � . . _ Eyr_-.. _ +c.. 3 .- -, .. -A603 rer- ,:: .N-rx' a,= .f ..'£'/. .l, ,>,, ., 3. __'T'J�'Y' ..r: G:s .Y`n ac`�Y a. + r E.:. t- Y'". .J ri.5 .,_a ., r 3. K-,. 5.. -,-r\ . ,z - ._0..F-:',. {'^ .5. :r z••o YCfa. S,- �Y, .•� -.#1 ! r ;.,F'�'n _ L: - L,S. .,.L+. A.•r2. . -,rva'S. �•.',Ly �F�C.r. C _ .:Lt. ..1"„-4. ) y;�`t.: E'-n _v..S''. .P),. \% _3 .Iai', le Ck N'.,::`1 4:/'_ 5..'4p: ,1'r',v `4. ..a < ''S .,., '_;. a :, ...¢__ht<+ r:_3 „'y$. ., :, 'v, ,.,_ -. .. ,;, .. _ •. .• - -. . _ _ L r �A60 '., / jI , _ ¢ ti j- a- , Y.. ,. 4. ... . - _..__--.---- r t,r. }... _ .. _ .. _ .: .. - - - -..,..k a n l -v. � s.:: rr'2 : .e-:::.x� r':v_:�.1 .:J ..n.._r (ty_ '�{ ,Ix. K ll... „J.. � _S'i ..�. :k.. �> Y:1 .4 i'*i', i f".r M1 .`l. 'iK.... ,�,.. u.,,�k{lY. r,.'v„3, .,�)', J`t r t 1?,4 a:.,}e y:1-.t[y� ,-«.Y,a ikA a,:",... ?,zr -^c' w 1,.:-r?v .p -<,ir Lvc. . }: F'j=, n!, F - �. r-,tf-4. :.'fi` „w, ,_y ,k i`4, t"a:. - . ,: ,, .r=•.,.. r. _ . ,y ,f _ ,<> ,,.,���,_ . .__:. ,;_.:, „, _ CT01 C RT I T t_ , ,�:, c �s x .; E AMC ILE ,vL. a R TU NS LA' 7 �. ,�:',. �t _�:� �. E R - �, srM` r4 1- k F'- s: t .r ., •>1 . , " , .'I1P i�,. it Y u,. ..- -�-"•{. s.. e.. .:... .,, o' , ,.: ..l�r,r• r I-.. r 1 .r3'�: . y'4.a _d�,<,.�. . ,<_ . "^,.tr. c ,.., ..1 „✓_ t _�',. •,. a.6i..v„ 5 - �_� .rr` •,S'.. sn r P �01 ,,.,., kr, ny'v'r"k't ,. + 2- .. -:..u• i v, ... :/n..,x� c,.. ^r',�J _ t:� . .S ,. v. , .'< .,.\4 .r �i 5f" :.1.. ,'v '+'f- ..,Y..,, _, _f}n..vm h: -._.,n _ _ ,:F ,.t c :,i'tY!f'33•? i•t .,5.-i.•T,•' .tr h ,.qT. 7 \*ppr.-I , 1 I .u._...,.}.'+ 1e,a_a.Y.-,1_",�:'.,a-.,.2... cv./ ..rY.., i6 r., v-.c. , , ..w... - - I - .6.JY. 1 e,. rtSl .. tJ:L'i-.•t' ] !at i:,.. Jl _..s... S., -i-- .,,, - i,� -u a„�': 15X 3 .�L ,u r s.: :t'.r x'.1 i 6 ,Iz. r.r „1- tT• - t • L"C - `1 � c.YF L 4't".F-ram'- v,t - '.il: �" I. +s,-'1.,. ,7'. is .n.-.. `rl , r I tv ad. s a v. •s, f -L.h s. 1 '.r t t .r r:�Jt r� v.�- .yq.V ..J C.v %T4 . l.'_� t't,r �.rY , �� I yy ,d-r Y, a. :.x as _ � , a _ MAT-01 WAL -OF GRILLE :' x. .-�".a9-,tee s,.,,.,.,'l-4.:,u fit.,.r. .F-k'eV.t 'F• �v__'•t J,v..,-a,rs :f:¢::1.: itvf3�.:Iz�xm .Y :'?te,i:: �t;;.:, :, .:. � •• .' :. �, }`r.., +,;,. r Yv-,IST. - K F ..-:I..r�-`-'- .�Qt.•gy e.. ax,�.:4l,c-,­ --:t. v,'c, ci - - -_ ,.}' ,._' - •� --•r"J A- , _ r , -- { � v x.vt iv :a,. � „> •L! ,_ rz. ?.^�`G• , =.... r'_zt_-;J'_ s_<. ,A<. .- ,,_ .,_ - .T - - t .^ri. - .!-ir, ...,..,.Y p. , 7= •.� 1._2r .,,,,.b IIt Y _., .., , .1 r.. -v., t='t, ... -Y.A , - - - _...__-_--___.._- - 4 :"k_ = t 3. .S'.,r a�� � .,, - _ 'J t •l - x _ .. - , -,v a. t; lt,Y :,,ar}r,.r.A - . _ _ �I •1t3, Y>,� - .� v,t'. �55x �`� ,rta ", r: - ' ` ,tv.�:`, -v., ,,S .r`J-Y¢ N` - • 5 1 1: j _ f. ! 'T _. , , ( -, i }i' FsSIc:'ynf ,._.. . 'fir•.. ?l,t�` As ti.>.,.,:. rra 7•,y/ L F Ykf nJnr-' n. .a .}� 9 _ . , ' , , , f.tt 7kJ c LS_:�,1 ,,.,. J d<{:�: _ .. _ < i f_5 - r.�}',•,._" :. .:, _1.,1 „ . r I . F s. - - r` F_ -. r� :r £.,.'.`r-!,, J - _, _ . - _ ! . . 7,_.c, ,» u„}'.;.4". rl1 -:r:n,.:•L't L"u :.ri t. .'>-' r . - ,i'�` s-'m, I - I y,.�Z._=:-�- ri. .`c. •.,,-,:,w`+" 4.1vm -,..-�„t. 1, ! a - ,r,rrr-_.:44' ,1 4, }> 5; QT 01 QUARTZ TILE r• I WOMEN S RESTROOM ` r _ 60 '.s ,.��ems;. ]. ,vrt! .< rt 7 o - - - - _ Y - f 0 - - . T r 5 LIGN�,:. x A ,:, s ,:vl '• Crr, 1 .;fir� t r,...r..:. - ALIGN' ..1,. - ♦ 1. fir, ., 1 M n.I: L h 't a ,"fi�=c.a;.,,73M;t�n•s�ar,r _ r4�,<k�. A603 _ � m .. I I I - a.rZ;n'vF:Y:i:{.,J) 'c. .c.. r'S.{:.IYTMr' _ M :A'^+ K.,.,t. WD - :, . FL 01 WOOD FLOORING .. , 4r-,:.,, ,:, m. is .-w:,�- ii•`;:" I I I =rr <+t -> :r ,r - I I I Yw, ..F.c .c_ ._,y,. -,r fiIM .. wr , <.;.,,._ K--,t ALIGN : A603 NBC u l tu'� #, I 14'- 10 3/4" U , 15''_7 112 �' 7: ,_s;'r;.;?„_.,-,,.__ 8' 1 1 .10' 10 -11' 71/2" 21'-71/2" MONOGRAMMING . F'.itrs :� rt.._t.__ :. �, 0 �:: i •t ''; �pr t 5 . a:Y CC 01 . ti�_r - - - _ � . _ - = - : . - ItiyrryI, : . '- - ' ._ - - - - - - - - ` - - - -. _ 28' 9" 6' 0" 7' 10 1/4" 18' 1 1/4" : N cc01 � . 1'-21/4" ^ r� g 15'-10 3/4". ' - n - :, 1 4 . . _ - _ - 1 N r � _ _ _ _ _ m M - _ N O - - - - - 3 � '. 111.6r1 - - ( ) . T 10'- 11/4 10'-81/2" 1,4­ t:� v 1 ' -1 °,Lrray t 10'-8,/4" 0 , , a v3 18'-2' S ' }' }a r, , 'G5 YY.;'F$ 1 �yvr t3r}y 56 K>u- ` , s BIKE S�iOR: 0 4' 9 1I2 ' w 3rr i,.� 'O . , r` kl ,K,'i"tyv9r -T i N - T'} Y Jt r! 5 ,4-z" ,��y ,Y : 5 NIr�Ji 11L�',� 1�IHT�, h:l:L� l� '1 - ' '1 S Y.jl l:{,, :4 - 7 / t 'It , ' A603 • : ' , 1. _. - - - ' - DF 01 Asoa - R :01 ',. : . / , . _ �,.; , , : I - -- " 1 .. . . . - - 1. 111-6' 9'-931411, -. - - -1 - , M. ,I 17 03/4" 0 5'-2'.' .N , '. . - � I. 1� - , . '." '. =' - . '�� 15'-5 3/4" 4� ' . . ,. 14- - _( ) ! " � ,. N' :M 5' 101/4" O1 - v 5'-2 112" v' •9'-9112" °? , �' ' t0 _ : _ : r0 _ _ 9 . 11' - .R M1 rD" ` _ 1. _ _ m. ' �? 0.1 T-81/4' 6'-81/4 N , _' , N , - _ - _ . , - _ . r _ ,• _ _ _ - F(V 02.09.07 ISSUE FOR BID .- - .. . . . . - Date Descri lion S'IM No B P v • . _ . . . • . : '�'�:- : I 5' 4" 15' 7 „2" I:� L L Bean r ' r rorv,l SALES AREA . , . . .i. • . _ �: , , . .. 1. :'44 . ' 7r_8" , ;, . , : • . . „ ',. . :;�. CC 01 . . ' , - 1 . r :, , _ . .. . . - •CASHiNRAP� ' .•slur' `1 �' '- • - . . 2 7' 1 I'" , , 101/4'. N•SFLTTING .bOM - A603 P p1 • - - - - I - - I :'I ., . : -' T j, ;� � I . , - . - . . a '.. - - . - � : .'' *R, . : D: V11 ' MEWS Fa FTING ROOM ` ,, 1 ,fin n , �,-..,4.. . 4 w,•- f. ` YJ �]�,.H( ' '1 •. . . , . I � k I . nL C'. ..'4Ae:�.. Y,•:t R 4r . \x _ "N. �I' .I „4 v ,>v F4 L l 3 -�."a}48`i..y. $ 4.L2'fr:4`;FL :'S •J n - .'f.-fi J" l iFf -'1�l} :i ,X t E�TIBtl a ` - - - I I - - - - _�_ - ___( 97�- -�-�- -�-�-�_ _�_�_L �_ _�_ -�-�- -�-� - � t < n. -� - - 4 - 117� A:: - - - - - i . . ' - "".--t rt, . I I CASH WRAP CL T ° , I I 1 A603 ® m� ® ® 7 01i 16 ® ® The Shops at Evergreen Walk ; 75 Tamarack Ave I I I I I I Building C, Suite 75 South Windsor, CT 06074 F E D C.7 C.2 C g q FINISH PLAN . Checked By: Checker .lob No: 06125.00 1 Finish Plan Al 04 1/8" = 1'-0" --- ---------- _ _ _ _ ___ . , _ __ _ ._ . . - _ , ,. _ . . .. -- __ . _ �... _ _ .-.. . _- __ _ . _--. __._..__ ., -. ._ . _ _ _ _.. _ _ _ _ -.. -_ . - - . _. __ . , . -. ._ . - - _. ....._ _ _ -..-.-_ _ ,_ - .. . . ,- . . _, _ . _ -._ _- - -' ' _ -_ .. _ _- _ - _ ._ .... . _. , , .- ._- _... _ - . , _ "-- _. __ _ -,. _ _.... _ _ _ _- - _ .. _ _ __._ . _ __ _ _,_, _ .. _- _ __... - - _ _ _..._ - ., -_ _ . . __ _ _ , . .-_ C:1Revit\SW indsor\125-base-local-sh(Recovery).rvt 2/9/2007 1:52:50 PM FIXTURE LEGEND 'U 0 WFRB WOMENS FITTING ROOM BENCH N Q MFRB MENS FITTING ROOM BENCH ET m 2W TWO WAY FIXTURE E m O TSS TREE STUMP STOOL r` 0 0 N L m .0 T TNT TENT o U SS SUNGLASS SPINNER C� SB STUMP BENCH CS ROPE STANTIONS FC ROLLING BOX FIXTURE I U HFC ROLLING BOX FIXTURE a � I o � O ��� EMPLOYEE LOUNGE I�_�tl RA HANGING RACK FIXTURE _ o � U I - - - - - - - BC BIKE COUNTER POD POD FIXTURE ° u - - - - --_----- _ _ a ^°' o A ---- - 0 Y Fr FARM TABLE a o _ 5 - - - - - - - w � maw S --- - I I OFFICE - QR�00 I II 0 FTB FARM TABLE BENCH _ ------ FE RM-" SHOWER RM FTS FARM TABLE STORAGE II VENDING MACHINE I -- - - - -I _ GO-02 METAL GONDOLA - - REF i I 7'-8 1/4" ; - I EGRESS HALL HHC HEN HOUSE CUBBY UTILITY CLST 4. 1 III- - - GPS I -] o GPS FIXTURE I RCS I t a ,iI RETURNS I M.EN S RESTROO i of r ODC LAYOUT TABLE -� _ _ FWR I 4 (nal M 2 - III w I — L _ U I — - RCF _ — c� I., II OD ODC DESK CD _ - - - -- - - - � •o -i CC 01II - - - � � I—J' ' M II I —_ _ - I FWR I I FT Fi — — ;UVH GO-01 GONDOLA I FTB __ — _ 4LJ FTB N I S C R I I 4W FOUR-WAY FIXTURE FWR _I GC TO STRIPE FLOOR WITH YELLOW 8 I �l _ BC SHELVov) ING BENCH COMBO I i m FOOTWEAR TABLE PAINT TO DENOTE CLEAR FLOOR � -" . - - i 2 l� AREA REQUIRED FOR ELECTRICAL PANELS WOMEN'S REST OOM � �"/T -B i I 6 g 48 � 4B N I' FWTR FOOTWEAR ROUND FIXTURE B FWR � - 1 c2'-3 3/4" 1 FTS _� FT B Fvvr 0 MONOGRAMMING R --' LL// = FTS FTB 1 FR FOOTWEAR RACK N CC 01 �� FWB FOOTWEAR BENCH I B I I R I u PT FOLDING TABLE _ O 0 0 0 O 0 CAN ` 00 DBP I i I EXTENT OF CC-01 u ✓ I 'B' - — ' „ _ HFC p_p - � -' n i I N I t. < - - - p-p �-^�n O-0 n j I FRF FLY RODS O_p o-0 O-0 I 2TBR 3 FF FLY CASE - p_p O.0 HHi `T � >z i OD I�.., I � FTD FLY TIE DESK y of CONNFC UPS. O-0 �C� �pRCHl1'FQT�cG 8•- O 0 p_p FTD ', , „ OP DBP DOG BED PLATFORM HH ' _ 11-,Z� 111 -- _ I I II , T x MI WALL HUNG MIRROR �� ?J � r S % I FIXTURE TO HAVE j `. ', O-0 r a�> CASEWORK LIGHT L S IBC FTB T I v�, (I I MI-02 FREESTANDING MIRROR Iv MI-03 3WAY MIRRORr., �I-�� I 4 _ MI O FOOTWEAR MIRROR , �I MI-07 FITTING ROOM MIRROR �,,, t . °.. -i FF FRF p° ;TNT .I , ' FG'/�:'';� 0FT Q� �F,�Dr Y FC "\ CAN CANOE FTB C� [Lf o > lV FF O-0 y I j CC CAMPING CHAIR 0 0 - ti c9 RC ROCKING CHAIR O ( `� •~ d3 L Y1^I 4 FOOT BENCH ",ED. i1R��t, , FC O 38 3 FOOT BENCH FTB - - - _ I T f BARREL —FTS � AT ACCESSORY TOWER 1 &1 B � G S FIXTURES SHIFTED TO CLEAR A 3'-0" _ �' 2TBR TWO TIER BIKE RACK CLEAR PATH AS REQUIRED. FTB - �LvI �,I I �c� 1 A B FTB Q�� _ 0 FT t� d FTB r r I Q ` IT-6�" M FT I g B1111111 C I - 1 KV 03.13.07 REV. PER TOWN COM. I POD I /� KV 02.16, 7 ISSUE FOR ADDENDUM I 88R EIGHT BOAT RACK 02.09.07 ISSUE FOR BID -- I B / w/ g 3,_T 314", _ o w w- I r -I ` No By Date Description -_ion L.L. Bean N 1 , �2„ - � a�--� � � N �� I &1 IIIi-- rI I 1 POD T I I RCF RETURNS COUNTER FRONT IT � o B Q � � FTB FT I FTB 1 n I PT `� RCB RETURNS COUNTER BACK FIXTURES SHIFTED TO CLEAR A 3'-0"B /A' r I / CLEAR PATH AS REQUIRED. ` 1 -2 3/4 CRT CRT STAND 01 p 2 3/4" MI 01 I 1 MI-07 _ --� _0 FT � � � �c� n �..' . 7 M MI-07 °' -- - H C ;HHC HHC I IT IMPULSE TABLE - I A`S�RAP CW-02L. -" I ��i - - --FR' 8 CW 01 BW ID MEWS FITTING ROOM I cw-o2R D1 BACK WRAP ' T MI07 'I FR FR Iifnul J MM 4 2001 r I O-07 ID INFORMATION/MULTI-CHANNEL South Windsor - - - - - MI-07. g g II I , i D DESK BUILDING DEPARTMENT B - $I I- II 3„ BW CASH WRAP CL I-- MI-03 MI-07_ � - - - ,�'�I` _ 2,_ I S J I MI 03 B C R I-01I1 SCW SEASONAL CASH WRAP , u _ VESTIBULE- - -- _ ==- - - - _--=- ---- II MI-07 3 '0, 4'-6 1/2" =-_- - ----- - -- - _ -___ _ __ � ' BD I RBR - - - - - -: r MI-07 I ..M- ! � - 2 BAY CASHWRAP RIGHT 1 07 CW-02 2 BAY CASHWRAP LEFT - - —• -I-.1 2 3/ - - - - - - - - R" CW-01 1 BAY CASHWRAP V-23/4" 1'-01/2 0'1' --___ -- - I 01/2' —T— __- ----- NOTE: ALL FIXTURES BY L.L. BEAN The Shops at Evergreen Walk WOMEN'S FITTING ROOM' —O 75 Tamarack Ave I FLYSHEET T GROMMETS, TYP. FOR (4), FURNITURE LEGEND Building C, Suite 75 I I - - _ _ _ _ ATTACHED IT BUILDING STRUCTURE& I South Windsor, CT 06074 - - - - - - - - _ _ _ _ _ _ _ _ _ FIXTURES WITH SHOCK CORD @ 12'-0"AFF. I I I _ _ _ _ _ _ _ _ EXACT LOCATION&MOUNTING TBD IN FIELD BY r ARCHITECT. SBO, IBGC. LOWER SPRINKLER " - - - - - - _ _ _ _ _ _ _ _ _ _ BENCH, SALES FLOOR FIXTURE PLAN & HEADS WHERE REQ. BY FIRE MARSHALL IF _ _ _ _ BENCH, FITTING ROOM F OBSTRUCTIONS OCCUR. I I STANDARDS LAYOUT E i D C.7 CAMP CHAIR C.2 L FIXTURE PLAN B A � DESK CHAIR 1 checked By: Checker ROCKING CHAIR .lob No: 06125.00 TABLE, EMPLOYEE LOUNGE I STACKING CHAIR, EMPLOYEE LOUNGE 3/14/200 PROJECTS\South Windsor\125-base local_kv.vt NOTE: ALL FURNITURE BY L.L. BEAN Al 05 3/14/2007 11:48:42 AM - U C 1 N r 41 N NOTES 1. FOR DOOR SCHEDULE SEE SHEET A602. E m 2. SUNFILM ON ALL WINDOWS ON SOUTH & WEST SIDES OF THE BUILDING. m SEE SPEC FOR DETAILS. 0 N m .T O. O U i U N P. 0 -9 o 0 R MATERIAL CHANGE ROOF BY LLIF T.O. CLERESTORY ROOF 39' - 11 1/2" — - � ROOF LADDER BY LL 48"HIGH INTERNALLY ILLUMINATED SIGN.LL TO PROVIDE STRUCTURAL SUPPORT IN WALL FOR MOUNTING. G.C.TO PROVIDE J-BOX FOR POWER&PROVIDE FINAL CONNECTION. T.O. LOWER ROOF TENANTS SIGN VENDOR TO INSTALL. 4 \� 29' 4 I 2 ,, o A405 TRELLIS BY G.C. Lr � OLO � ALIGN TOP OF TRELLIS WITH TOP OF r� MASONRY BRICK BY LL WINDOWS, COME AS CLOSE TO SIDES OF . . . _ _ _ _ _ _ _ _ WINDOWS AS POSSIBLE USING FULL WIDTH f BOARDS. START VERTICAL LAYOUT USING CENTERBOARD. I 17 Sim — T.O. WINDOW & Azos TRELLIS BOARD&BATTEN SIDING BY LL 15' - 0 1/4" G f i GC TO INSTALL BIKE RACK BY OWNER 1i8 T.O. STONE BASE 2, - 0„ SONO TUBE FOUNDATION - PIER BY G.C. (TYP.) _ ENTRY LEVEL 00" u 2 EXTERIOR ELEVATION - EAST ACCESSIBLE RAMP&RAILING BY LL 1/8" = 1'-0" ALUMINUM CURTAIN WALL 48"HIGH INTERNALLY ILLUMINATED SIGN. SYSTEM BY LL LL TO PROVIDE STRUCTURAL STEEL IN CURTAIN WALL FOR MOUNTING. G.C.TO PROVIDE J-BOX FOR POWER&PROVIDE ROOF BY LL FINAL ELECTRICAL CONNECTION. TENANT'S SIGN VENDOR TO INSTALL. T.O. CLERESTORY ROOF 11 START LAYING OUT HORIZONTAL MEMBERS WITH THE TOP TRELLIS HORIZONTAL BOARD TO ACHIEVE CORRECT HEIGHT& SPACING. SEE ELEVATIONS FOR BEGIN TRELLIS @ THE LAYOUT OF VERTICAL MEMBERS. EDGE OF PORCH ROOF _ T.O. LOWER ROOF KV 1 02.09.07 JISSUEFORBID_ No B Date Description MASONRY, BY LL o ' 1 BOARD&BATTEN L.L. Bean ® A405 SIDING BY LL 1 X 8 FRT DOUG FIR WD 09 W/CLEAR L - - - - J STAIN.TYP.OF BOTH HORIZONTAL 9 e — T.O. Trellis , ?+ R AND VERTICAL MEMBERS. ATTACH \ TO MORTAR WITH 3/8"HILTI HLC-F 3 20 - 8 SLEEVE ANCHOR. A201 PORCH BY TENANT 17 TO TIE INTO LEDGER BOARD BY LL STAGGER BUTT JOINTS FOR VERTICAL STAGGERED SEAM STANDING MEMBERS BEHIND HORIZONTAL METAL PANEL ROOF SYSTEM MEMBERS,TYP. GC TO INSTALL + BIKE RACK BY OWNER i i + T.O. STONE BASE = 2' 01' u ENTRY LEVEL t 7— - o � ii� Ilil 1 102 II Ind u u L J a LJ u u PORCH ROOF DRAIN TO TIE INTO LL DRAINAGE SYSTEM. KNOX BOX BY LL COORD. FINAL CONNECTIONS TO STORM LINE W/LL. The Shops at Evergreen Walk PORCH ROOF DRAIN TO TIE INTO LL DRAINAGE PORCH ROOF DRAIN TO TIE 75 Tamarack Ave CONCRETE PIER 1'-4"DIA.X 4'-0"DEEP, BY GC,TYP. SYSTEM.COORDINATE FINAL STORM LINE INTO LL DRAINAGE SYSTEM. Building C, Suite 75 CONNECTION W/LL COORDINATE FINAL STORM South Windsor, CT 06074 SCULPTURE BY OWNER'S SEPARATE VENDOR, INSTALLED BY GC BOLLARD FOR POWER ASSIST DOORS LINE CONNECTION W/LL n TRELLIS DETAIL n EXTERIOR ELEVATION - SOUTH EXTERIOR 1/8 - 1 -01, ELEVATIONS ly Checked By: Checker Job No: 06125.00 A201" 6.1Revinm-base_Ioc L-jen.rvt 2/9/2007 1:36:27 PM I U C N m 0 0 Q m m i E rn m o i N L a) .O D_ O U E 1 E o UNDERSIDE OF UNDERSIDE OF STRUCTURE U o0. 29' - 0 1/2" — �- - STRUCTURE 29' - 01/2" STEEL BEAMrn >, PT 07 �v STEEL COLUMN AND RAIN PIPE I 6oN N o PT 07 I I I PT 02 PT 02 RAIN PIPE PT 07 I I GWB GWB 2"WD WINDOW TRIM PT 08 WD 06 PT 06 I I I i r 12'_7 12'_7" 12'_7" I 12'_7 FPT 01 PLASMA SCREEN FBO, INSTALLED BY OWNER'S i VENDOR, PWR&BLOCKING OA Oq BY GC e STEEL COLUMN - - - - '- - - - - - , PT 07 0 1X6 SOLID WD TRIM 1X6 SOLID WD TRIM PT 01 PT 01 Entry Level _ 1 Entry Level _ _ Entry Level Entry Level Entry Level Entry Level Entry Level O' - Or, 0' - 0" 0' - 0" FOR MILLWORK O' - O" FOR MILLWORK DETAILS SEE 7/A502 0' - 0" FOR MILL­ 0 - 0 FOR MILL- O' - 0" (NO STANDARDS) (NO TRACK) DETAILS SEE 7/A502 `WORK WORK v DETAILS DETAILS V FOR MILLWORK DETAILS SEE 1/A501 SEE 71A502 SEE 7/A502 i n WINDOW DISPLAY WALL n DISPLAY WINDOW ELEVATION n SIDE WALL IN DISPLAY AREA n CW ELEVATION (5) n ENTRY FEATURE WALL n CW ELEVATION ;� DISPLAY AREA U 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-01, U 1/4" = 1'-0" 1/4' = 1'-0" 1/4" = 1'-0" U 1/4" = 1'-0" C C.2 C.7 D UEE I I I I I UNDERSIDE OF — — — — CLERESTORY n 36 - 11 1/2" I I I I I I I UNDERSIDE OF LOWER ROOF - FN 02.09.07 ISSUE FOR BID I -- - -- — — No By Date Description ---_--- L.L. Bean o�'�� PT 02 I I I PT 02 PT 02 I ( TOP OF TRIM 15';-6" PT 01 i I I — I �• ,0 PT 01 z^wowwoowTRIM I I I I ! The a Shops a Evergreen Walk 75 Tam WD 06 PT 06 Building C, Suite 75 South Windsor, CT 06074 I I INTERIOR ELEVATIONS I ' i Ent Level Checked By: Checker N 11 1�� JL I Entry IFOR MILLWORKI, FOR MILLWORK DETAILS SEE 1/A501 (TRACK) I, FOR MILLWORK DETAILS SEE A/212 _-_ FOR MILLWORK DETAILS SEE 1/A501 (TRACK) I, FOR MILLWORK DETAILS 0' - 0" Job N0: 06125.00 `DETAILS SEE�- - — �( ?—SEE 11A501 (NO TRACK) 1/A501 (NO TRACK) 1 ENTRY ELEVATION 1/4 - l-0" k02 A 02004 C:1Revii\SW indsor1125-base_local-sh(Recovery).rvt 2/9/2007 1:26:56 PM - U C N 49 0 ! O N Q i a UNDERSIDE OF D UNDERSIDE OF STRUCTURE 29'-0 1/2" UNDERSIDE OF E _ STRUCTURE UNDERSIDE OF STRUCTURE 29'-0 1/2" e 29' - 0 1/2" — ST29'C 0 1R2" o 04 m a U I • GWB PT 02 PT 02 PT 02 PT 02 PT 02 U GWB GWB o n TOP OF SLAT I6'-7 1/4" TOP OF SLAT I6'-7 1/4" o ,a TOP OF SLAT 1V--7 1/*' PT 02 PT 02 TOP OF SLAT 16'-7 114" a' 0 o rc o Y -0vo o T 3 11 11 rnu o CI Ox w PLASMA SCREEN PLASMA SCREEN PLASMA SCREEN FBO, INSTALLED BY FBO, INSTALLED BY FBO, INSTALLED BY OWNER'S VENDOR, - - - - _ _ OWNER'S VENDOR, 4"DOOR TRIM - - - - " - OWNER'S VENDOR, PWR&BLOCKING ' PWR&BLOCKING PWR&BLOCKING BY GC WD 06 PT 06 - - BY GC - BY GC ' i o ' 129 0 0 � rn \ n 0 ` Entry Level ENTRY LEVEL 0'-0" ENTRY LEVEL 0'-0" — Entryy L 2V21 FOR MILLWORK DETAILS 0' - 0„ FOR MILLWORK DETAILS SEE 1/A502 SFOR EE 1/A 020RK DETAILS O' - O" V SEE 1/A502 FOR MILLWORK DETAILS SEE 1/A502 n 11 KIDS LEFT OF DOOR n FOOTWEAR FEATURE (R) n FOOTWEAR FEATURE CTR n FOOTWEAR FEATURE (L) n FOOTWEAR RIGHT OF DOOR n FOOTWEAR TO STOCK ROOM n FOOTWEAR BACK WALL 1'-0" 1/4" = V-0" 1/4" = 1'-0" ;J 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" U 1/4" = 1'-0" UNDERSIDE OF E UNDERSIDE OF _ STRUCTURE _ STRUCTURE UNDERSIDE OF STRUCTURE 29'-0 1/2" TOP OF STRUCTURE 29'-0 1/2" 29' - 0 1/2" STEEL JOISTS PT O2 STEEL JOISTS I PT 02 PT 02 � PT 02 I PT 02 PT 02 TOP OF SLAT 16-7 1/4" TOP OF TRIM 15'-6" TOP OF WALL 15'-4" TOP OF WALL 15'-4" PT 01 I T-0"MTL STANDARD 4"DOOR TRIM 1 ,)3 ' ,® LINE OF WALL MIRROR FBO INSTALLED BY GC � I I Entry Level Entry Level® _ FOR MILLWORK DETAILS SEE 1/A502 01 - 0„ FOR MILLWORK DETAILS SEE 1/A501 (NO STANDARDS) 0' - 0" FOR MILLWORK DETAILS SEE 5/A501 FOR MILLWORK DETAILS SEE 5/A501 �`(NO STANDARDS)w`-(STANDARDS) n FOOTWEAR LEFT O RETURNS MEN S BACK WALL- LEFT OF RETURNS n n MEWS BACK WALL J 1/4" = 1'-0" 1/4" = 1'-0" U 1/4" = 1'-0" J 1/4" = 1'-0" _-_ K1/ 02.09.07 ISSUE FOR BIO __ No By Date Description 2 3 UNDERSIDE OF 1 UNDERSIDE OF L.L. Bean _ STRUCTURE STRUCTURE -- 29 - 0� e 29' - 01/2" — " lr co STEEL BEAM I PT 07 ,; i' STEEL COLUMN 1 PT 07 PT 02 OPEN y TOP OF TRIM 15'-6" TOP OF WALL 15 4 TOP OF WALL 15'-4 I ` TOP OF WALL 15'-4' The Shops at Evergreen Walk i 75 Tamarack Ave Building C, Suite 75 I South Windsor, CT 06074 i PT 01 „'-o"MTL STANDARD INTERIOR ELEVATIONS zIrI I �- SLIDING BARN DOOR FLAT TRACK CROWN - - - INDUSTRIAL - -- Checked By: Checker "SLIDING"WALL MIRROR FBO MI-01 Job No: 06125.00 I i *—A LLJ[ 136 4"WD TRIM CASING ON DOOR WD 0>6 PT 06 I , _ Entry Level _ _ - - ' `, Entry Level ENTRY LEVEL 0'-o" _ Entry Level O ------ A203 ' - O" ® FOR MILLWORK DETAILS SEE 5/A501 O' - O" 0' - Q FOR MILLWORK DETAILS SEE 1/A501 (TRACK) � FOR MILLWORK DETAILS SEE 5/A501 FOR MILLWORK DETAILS SEE 5/A501 (NO STANDARDS) n WEST PERIMETER WALL ELEVATION n ENTRANCE TO MEN'S FITTING ROOM n OUTSIDE MFR n OUTSIDE MFR (L) ____ _ ._._ . --- -- -_._.. - .. _ .._ . ---.1/4_-.1 -0 -_ _ _. . __. .__ . _ _ _ 1/4 -_1._-0 _ --- .__-_ _.. . ._ _ . . 9l4 _1 C:\Revit\S W indsor\125-base_local-sh(Recovery).rvt 2/9/2007 1:33:02 PM U C m 0 m E I m m m O O 'G 0) 1 � C - U Alk 8 E H i o PI O 11'-0"MTL STANDARDS yy ,^ o o b u q v o ° I SLIDING BARN DOOR FLAT TRACK CROWN INDUSTRIAL "SLIDING"WALL MIRROR FBO INSTALLED BY GC MI-01 105 4"WD TRIM CASING ON DOOR WD 06 PT 06 FOR MILLWORK DETAILS SEE 5/A502 FOR MILLWORK DETAILS SEE! 2 i 11 ENTRANCE TO WFR n OUTSIDE WFR B 3 2 UNDERSIDE OF _ STRUCTURE 29' - 0112" 6 I I I I I I I PT 02 I PT 02 I PT 02 PT 02 2"WD WINDOW TRIM WD 06 PT 06 TOP OF TRIM 15'-6" ° 2"WD WINDOW TRIM _ E WD 06 PT 06 I 11'-0"MTL STANDARDS I — PT 01 0 PT 01 03 ' A it ' FIRE EXTINGUISHER CABINET I LINE OF MIRROR FBO INSTALLED BY GC MI-01 i I � ° I � i i I i m Entry Level FOR MILLWORK DETAILS EE 5/A502 FOR MILLWORK DETAILS SEE FOR MILLWORK DETAILS SEE 1/A502(TRACK) FOR MILLWORK DETAILS SEE 1/A502(NO TRACK, NO STANDARDS) 0' - 0" 1/A502(NO TRACK,NO STANDARDS) 9 OUTSIDE WOMEN'S FITTING ROOMS L n EAST PERIMETER WALL ELEVATION 1/4" = 1'-0" " 1/4" = 1'-0" B A 4 C UNDERSIDE OF STRUCTURE 29'-0 1/2" KV 02.09.07 ISSUE FOR e_ID No LBLFDate Description Kz \ L.L. Bean I I I I I i ce ' i r PT 02 PT 02 PT 02 PT 02 PT 02 I PT 02 \ 4 GWB A509 I I TOP OF TRIM 15'-6" C ` I I 11'-0"MTL STANDARDS j The Shops at Evergreen Walk F PT 01 PT 01 PT 01 75 Tamarack Ave ing C, Suite 75 1 1/2"WOOD TRIM I I SouBuilth Windsor, CT 06074 WD 06 PT os I INTERIOR ELEVATIONS \ 4"WOOD TRIM I \ Q ` \ / / // I WD 06 PT 06 ,' TRIM N� I Checked By: Checker 114� LLI Job No: 06125.00 i ItLL t L1-4— ' ENTRY LEVEL 0'-0" �' FOR MILLWORK DETAILS SEE 51A501 FOR MILLWORK DETAILS SEE 1/A501 (NO STANDARDS) FOR MILLWORK DETAILS SEE FOR MILLWORK DETAILS SEE FOR MILLWORK DETAILS SEE FOR MILLWORK DETAILS SEE 1/A501 (TRACK) 5/A501 (NO�STAND�RDS) 1/A501 (NO TRACK) 1/A501 (NO TRACK) i A 2``6 0 4 n HOME &TRAVEL / ENTRANCE TO RESTROOMS /WINDOW TO MONOGRAMMING n HOME &TRAVEL n HOME & TRAVEL - RIGHT OF DOOR n KID'S (R) n KID'S ANGLE WALL n KID'S BACK WALL 1 KIDS TO STOCK 1/4" = 1'-0" 1/4" = 1'-0" 1/4' = 1'-0" Y 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-01, ------- _ ._ . _ . _ _ _ _ _ _ .. . _ _ . C:1RevitlS'Aindsor\125-base -local _ _- _ _. _ _.__. .._ _._ _ __ .._-_ _.___ ----.._. -.. _..... . ..__ - ._..-..___ __._ _. . _ .._ . _ _ _ .__._ .. ...____. 2/9/2007 1:36:04 PM U C m 5 U N N E I m m I m O I O I N OI 10 ;i O A803 U 4"X3/4"WD TRIM WD 06 PT 06 i PAINT WALL PRIOR TO SLAT �L$ T[ONOF 4"X3/4"WD TRIM PT 08 WD 06 PT 06 SCONCE FV HOOK FBC GC TO INSTALL AND PT 08 ° •; PROVIDE BLOCKING 5 1/2"X3/4"WD SLATS 1/4" 4"WD TRIM i °v SPACING BETWEEN SLATS WD 06 PT 06 n o rt kI BENCH FBO 51/2"X3/4"WD BASE B a Y 5 1/2"x3/4"WD TRIM WD 06 PT 06 w� ; w P. w WD 06 PT 06 i 6 WFR_ TYR FR ELEV. (D) 15 WFR_ TJ. FIR ELEV. C U 1/4 1 -0 1/4 - 1 -0 B B 1 o PT 02 E A 03 Q PT 02 EQ EQ TRIM 4"X3/4"WD TRIM / WD 06 PT 06 4"X3/4"WD TRIM 4"X3/4"WD TRIM — 4"X3l4"WD TRIM 4"X3/4"WD TRIM WD 06 PT 06 WD 06 PT 06 WD 06 PT 06 WD 06 PT 06 WD 06 PT 06 PT 06 scoNCE PAINT WALL PRIOR TO SLAT PT O3 HOOK PANEL FBO GC TO . INSTALLATION HOOK PANEL FBO GC TO MIRROR MI-07 FBO GC TO PROVIDE BLOCKING AND MIRROR MI-07 FBO GC TO i ` PT 08 PT 08 I PROVIDE BLOCKING AND PROVIDE BLOCKING&LIGHTING INSTALL PROVIDE BLOCKING&LIGHTING HOOK FBO — INSTALL 3-WAY MIRROR MI-03 FBO \` 4"WD TRIM GC TO 5 1/2"X3/4"WD SLATS 1/4" PT 08 PT O8 INSTALL AND SPACING BETWEEN SLATS PT 08 BLOCKING&LIGHTING TO PT 08 BE INSTALLED BY GC WD 06 PT 06 PROVIDE BENCH FBO BENCH FBO SIM BLOCKING. WD 06 PT 06 SIM - 5 5 1/2"X3/4"WD BASE 51/2"X3/4"WD BASE a 5 1/2"X3/4"WD BASE 6 ADA BENCH I A509 WD 06 PT 06 WD 06 PT 06 WD 06 PT 06 A509 e 51/2"X3/4"WD BASE ADA BENCH 5 1!2"X3/4"WD BASE WD 06 PT 06 — s 1/2"x3/a"wD BasE WD 06 PT 06 I/Ml 51/2"x3/4"WD TRIMC?t WD 06 PT 06 5 WD 06 PT 06 , A5Sim 09 n WFR - TYP. FIR ELEV. (B) 13 WFR - TYP. FR ELEV. (A) n WFR -ADA FIR (WEST) n WFR -ADA FIR (SOUTH) n WFR -ADA FIR (EAST) n WFR-ADA FIR (NORTH) WOMEN'S FITTING ROOM (EAST) 1/4" = 1'-0" 1/4" = 1'- " 1/4" = 1'-0" ` 1/4" = 1'-0" `J _ " 1/4 - 1 -0 1/4 = 1'-0" 1/4' = 1'-0" 10 B A803 A t7 C7 i� W4 C3 ° '•�' w W4 W4 w W4 w w C, I A B ;, y i a W iJ o i 10 A803 f>, L5 \I L5 L5 1 w L5 ". „i STEEL COLUMN B A PT 02 A803 4"X3/4"WDTRIM wU .` t w /. % w PT 02 PT 02 WD 06 PT 04!X3X'WD TRIM 6 �I EQ EQ i WD 06 w ,y� cr HOOK ON DOOR FBO HOOK ON DOOR I w BY GC, TYP.TALLED 4"WD TRIM TYP. FBO INSTALLED 4"WD TRIM TYP. q WD 06 PT 06 BY GC TYP. I WD 06 PT 06 LW4 m ( I L_0 r )I PT 03 1 PT 03 ___i Ls i! I; ; KV_ _02.09.07 ISSUE FOR BID —_ —--- — co ' 5 1/2"X3l4"WD BASE L5 L5 _ L5• No By Date Description _t W4 W4— W4 0 5 1/2"X3/4"WD BASE `\ WD 06 PT 06 I L.L. Bean WD 06 PT 06 � o -o m m ----- - --- - -- of coin ,,. n WOMEN'S FITTING ROOM (SOUTH) WOMEN'S FITTING ROOM (NORTH) RCP - WOMEN'S FITTING ROOM 1/4 - 1 -0 I. B A 5,_4 2 _3„ 4 _ga 1,_8" 3-_4, 1'-8" 3'-4" 1'-8" 3'-4" I 1=tE 1 111411 /�^�� g w 6 i 2 A205 1 II 6 05 1 The Shops at Evergreen Walk ,, 1 I w zt 75 Tamarack Ave Building C, Suite 75 Sim South Windsor CT 06074 i 6 1 8 � T3 � 112 111 110 _ A509 PT 02 6 I w WOMEN'S FITTING 1 6 ROOMS - ENLARGED „ " " o ^� A205 8 z" 3' o" 2" /— WD 06 PT 06 WD 06 PT 06 WD 06 PT 06 6 a PLAN AND 7 WDTRIM 6 w ELEVATIONS 6\ 4 � 106 I 107 I 108 109 - A205 — - - Checked B Checker I I! I I 3'-0"MTL STANDARDS � I 0 Y� sT-REG I PT 03 _ w .lob No: 06125.00 N I �� WD 10 PT 08 3 A205 2 - 1 Iw � w PT 03 I g w 15 1/2"X3/4"WD BASE 5 1I2"X3l4"WD BASE 5 1/2"X3/4"WD BASE 1 \� I I , , i � m ,� WD 06 PT 06 I WD 06 PT 06 �;• WD 06 PT 06 A20b LU 7'-2" 2'-1" 3'-3" V-8" 4" V-8" T-4" T-8" T-4" 4 WFR_ANGLED WA�mm WFR -AT ENTRY 1/4 - 1 -0 n W R- SHELVING WOMEN S FITTING RM ENLARGED PLAN evil\SWindsor1125-base_loca1-sh(Recovery).rvt 2/9/20071:41:33 PM Cl C N Q m W I m I O O N � C Ql a i Q U — PT 02 CEILING 4"X3/4"WD TRIM $ _ 0„ - -4"X3/4"WD TRIM -- WD 06 PT 06 WD 06 PT 06 PT 08 MIRROR MI-07 SBO GC TO PROVIDE BLOCKING&LIGHTING 4"WD TRIM PT 08 a WD 06 PT 06 °n -A BENCH SBO 61 U n 8 .G v oNO � o . 5 1/2"X3/4"WD BASE v N C U U N N O N 51/2"X3l4"WD BASE WD 06 PT O6jj WD 06 PT 06 E� n{ry Level - 00, _ 0„ rn O n MFR -TYP. FR (D) „ cn a U v 1/4" = 1'-0" MFR-TYP. FIR (C) ` Q " p P" V. 17 1/4" = 1'-0" EQ EQ 4"X3/4"WD TRIM PT 02 WD 06 PT 06 PT 02 4"X3/4"WD TRIM PAINT WALL PRIOR TO SLAT 8'-0"TYP. 4"X3l4"WD TRIM TION 4"X3/4"WD TRIM WD 06 PT 06 - - WD 06 PT 06 PT 08 m m PAINT WALL PRIOR TO SLAT WD 06 PT 06 4"X3/4"WD TRIM INSTALLATION HOOK PANEL FBO GC SCONCE SCONCE PT 08 WD 06 PT 06 / TO PROVIDE BLOCKING HOOK FBO GC TO INSTALL AND \ PT OS HOOK PANEL FBO GC AND INSTALL PROVIDE BLOCKING HOOK FBO 5 1/2"X3/4"WD SLATS 1/4" ` - 4"WD TRIM GC TO 5 1/2"X3/4"WD SLATS 1/4" _ TO PROVIDE BLOCKING PT O8 SPACING BETWEEN SLATS INSTALL SPACING BETWEEN SLATS AND INSTALL WD 06 PT 06AND BENCH FBO WD 06 PT 06 SIM PROVIDE WD 06 PT 06 0 PT 08 rn 6 ADA BE BLOCKING. "' 5 1/2"X3/4"WD BASE ' v ADA BENCH BY GC - BENCH FBO A509 51/2"X3/4"WD BASE ADA BENCH f^ 5 1/2"X3/4"WD BASE WD 06 PT 06 WD 06 PT 06 Entry L vel 5 1/2"x3/4"WD TRIM b 51/2"x3/4"WD TRIM 0 - 0 WD -0 WD 06 PT 06 MFR - TYP. ADA FR (D) MFR - P. ADA FR D 06 PT 06 MFR-TYP. ADA FIR B 16 MFR_TYP; FIR (B) 15 MFR_TYP; FR (A) 12 „ _ „ 11 „ _ _ „ 10 „ _ „ 1/4 - 1 -0 v 1/4" - 1 0 1/4 - 1 -0 0 1/4 - 1 -0 SIM 5 ' 5 A509 A509 F EQ EQ 0 w j% ' EQ P33101, QEQLI L STEEL COLUMN I I W4 \\ I PT 07 PT 02 4"X314"WD TRIM PT 02 I WD 06 PT 06 _10" 6'- a' TYP. rk CEILING �WDI 06 PT 8' - 011 I -- - _------LS- ---- -- W4- - - - 4"X3/4"WD TRIM HOOK ON DOOR 4"DOOR TRIM WD 06 PT 106 BSBO Y GC,TYP.LED WD 06 PT 06 3-WAY MIRROR MI-03 � � FBO BLOCKING TO 8E 'A INSTALLED BY GC MIRROR MI-07 FBO GC TO PROVIDE BLOCKING&LIGHTING 3 PT 03� PT 03 Ls 2'-6" 2'-6" PT 03 1 -L5 - L5 51/2"X34'WD BASE 51/2"X3/4"WD BASE 6 1/2"X3W'WD BASE LI WD 06 P7 06 _WD 06 PT 06 F WD 06 PT 06 OEnt0. Level EQ EQ KV___02.09.07__ ISSUE FOR BID _ No By Date Descripfion n MFR- TYP. ADA FR (A) n MEN'S FITTING ROOM (W) 1/4" = 1'-0" � „ � ,_ „ n MEWS FITTING ROOM (S) RCP - MEWS FITTING ROOM 1/4 - 1 0 1/4" = 1'-0" 6 1!4" = 1'-0" L.L. Bean F04 ir.. G; SIM 1 A509 I o I A206 2 A206 1 J 1 6 -Cn I 8 t / f M 137 6 6A o s 7 _ _ _ 1 6 The Shops at Evergreen Walk Asos HOOK ON DOOR 75 Tamarack Ave FBO INSTALLED - I r , A509 141/ y Building C, Suite 75 South Windsor, CT 06074 BY GC,TYP. PT 02 PT 02 F � 1 2 Azas 1 �L 138 4 MEN'S FITTING ROOM - 2" 3'- z" I " " � " " F ., I sA $ A206 5 _ __ ENLARGED PLAN AND WD 06 PT 06 WD 06 PT 06 WD 06 PT 06 3'-0"MTL STANDARDS —. C EILING - W 06 7 D PT 06 ELEVATIONS FIRE EXTINGUISHER - i 4"WD TRIM TYP- 8' - 0° CABINETmPT 08 D 1 lii I - -- ° I 6A _ Checked By: Checker zo �W0 N 6A 139 140 8 A206 a yob No: 06125.00 PT 03 0 600' PT 03 - -- - �- - O t� cO iv I III 1 l � EEI Ie-5112"X3/4"WD BASE51/2"X3/4"WD BASE5 1/2"X3/4"WD BASE 5 1/2"X3/4"WD BASE WD 06 PT 06 WD 06 PT 06 WD 06 PT 06 ; OEntOry Level WD 06 PT 06 - �m 51_0, 6'-0" 5,_0 n MEN'S FITTING ROOM (E) n MEN'S FITTING ROOM (N) �-ANGLED WALLANGLED WALL n MFR - FROM ENTRANCE 1 MEWS FITTING ROOM ENLARGED PLAN U 1/4" = 1'-01, LJ 1/4"= 1'-0" U 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-01, ------ _ _ ...- 6.1RevitlSWindsor1125-base local-sh(Recovery).rvt 2/9l2007 1:45:43 PM 0 N lu T N E o� LADDER TO GWB PT 05 PLATFORM YGCAGE m BEYOND SPEED RAIL SYSTEM SEE 91207 FOR #5 TEE @ EACH TOP RAIL INTERSECTION N SPEEDRAIL DETAILS I I L rn STORAGE PLATFORMN 0"MAX. SPACING BETWEEN POSTS 49 SIDE OUTLET ELBOW @ EACH CORNER o U -- 1 1/2"D RAIL w 07 CROSS AT EACH MIDDLE RAIL INTERSECTION 1 1/2"D RAIL M w 1 1/2"D POST GWB PT 05 #43 ROUND FLANGE @ EACH POST SECURED TO FLOOR AND SIDE MOUNTED AT EACH WALL TO RECEIVE TOP AND MIDDLE RAIL #94102 4"BEVELED TOE PLATE GC TO PROVIDE& 2'-0" INSTALL 121 TACKABLE _ #49C TOE PLATE BRACKET AT EACH POST WALL PANEL PT 05 FSC PLYWOOD PT 05 PLYWOOD .\ w a GWB PT 05 TYP. --- ,� v o o RB 01 121 120 125 124 122 �� , OPEN .. \` i' 'BEYOND fA nWC� W i LOCKERS PROVIDED BY LL BEAN, n STOCK RM ELEV 3 n STOCK RM ELEVATION INs�LLeo BYG_c 1/4" = 1'-0" " -0" I 5 C B A ! 3'-0" 4'-0" I T-1" 3'-6" 6'-0" T-6" T-11" 4'-1" 4'-3" T-3" 2'-10" 6'-0" 1 6'-0" 2'-9" EQ EQ GWB TO DECK ABOVE 5 - - - - - - - - - - - - - WORK ROOM j SAFE RM TEUCOM RIVI ( � I j SHOWER RM LADDER TO PLATFORM OFFICE I j STORAGEBEYOND j 1 0 I j i i I I R1 WD 08 j R1 j R1I R1 R1 j R1 I R1 R1 IR1 R1 I PT 05 CH s,_o„ N I j GWB PT 08 L ! - - - - --- -- -- - — I------- SHELVING BEYOND o CH 8'-0"j CH 8'-0" j CH 8'4' I CH - 8-0" j CH 8'-01, �- YES LOUNGE I ,l IACT 01 ! ACT 01 j ACT 01 I ACT 01 ACT 01 j MPLO 1 - ! 1 ' ------ - -- -I I --, ------ -------------- I !03 RB 01 - - I Entry Level 0' - 0', SDK ROOM ELEV 1 n STOCK ROOM - BACK OF RETURNS n RCP - EMPLOYEE AREAS C � A CABINET BY GC VENDING MACHINE, 7C BY OWNER 10'-0" 13'-0" /81-0" 6'-6" 1I'-7" 7'-8" 2'-0" I'-0" 2'-11" 2'-0" I 3'-0" I I I GWB TO DECK GWB TO DECK 9"MAX. 2'-0"TYP. 5 - _ i_ ? - - r _ _ - _ - r B 30"x48'" - — PT 05 PT 05 I i - - - - 1 - - - � - -_ - I - - - I - - - - - - - I CLEAR °: _ _ _ _ _ _ _ _ _ _ _ - I m SAFE R 'M I 10 @ SINK 3! o -- I 1A - - - - - - i+� f- - -_- -_- -0" "MAX. pp TYP. 9 JI SHELVING&STANDARDS 10'STANDARDS -I OFFICE I 6 10 WORKROOM 10 � EMPLO EE LOUNGE 12 CLEAR GGe N CONTINUE OVER DOORS& SHELVES I I 2 1 1 TOILET i� OPENINGS 9 A209 @ 10'STANDARDS ANCHORED I WD 08 o I I 5 A208 3 O 7 4 A208 1 18 A208 1 10 5 A209 2 8 GBSO I 11 TO WALL WITH EXPANSION / i 4 127 0 A208 8 1 I 17 q 10A SHOWS RM 7A 0^` BOLTS �., _ PT 05 ' 1— _ TB GO �H SNo \ SHELVES,TYP. -� I I -------__ - v 126 TELICOM ttll 4'- 1" I I o d - - - - WD 08 � � - T - -- T - - o I 2A I�t 38 3B PT 05 T.O. WORK 12s 124 M - _ — SURFACE T -211 9 B.O. STANDARDS _ _ 1 - 6 �I LADDER TO UPPER SAFE BY ' LEVEL STORAGE LLBEAN RB 01 RB 01 EMPLOYEE LOCKERS 4 TYPICAL STOCK ROOM ELEV 3 OPERATIONS / PROCESSING AREA 2 Employee Areas - Enlarged Plan INSTALLED BY GC U 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" i _- _KV__ 02_.09.07_ ISSUE FOR BID _ NOTES F E D IC B A No By Date Description C� L.L. Bean RECEIVING DESK ROLLING SHELVING SUPPLIED&INSTALLED ROLLING LADDER SUPPLIED&INSTALLED 1. Fire strobes and other devices mounted to the RETURNS DESK BY PIPP.GC TO APPLY SELF LEVELING COMPOUND BY PIPP.GC TO APPLY SELF LEVELING walls should be laced in areas which have TO ENSURE LEVEL SURFACE FOR INSTALLATION COMPOUND TO ENSURE LEVEL SURFACE ^ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ P (MAX 1/8"DIFFERENTIAL) FOR INSTALLATION (MAX 1/8"DIFFERENTIAL) no standards. _ 2. All shelves must meet in the corners - 1 _ _ _ _ __ _ _ __ _ __ _ _ ._._ ,J - - 3. Shelves must be installed per details r _ o o p - - - - - - LADDER �- 4. Maximize shelf installation in Back of House LADDER —► LADDER ► LADDER ► LADDER —► I L - -- 5. All shelves are 16" wide x 3/4" thick, melamine finished high density particle bd. with 1 Azo7 I - 4 ^ _ _ _ i _ _ _ _ _ _ _ rounded front edge, supplied and installed / o o Azo7 7 I ' by GC. (8 Shelves per standard, U.N.O. TYPICAL_ LADDER LADDER —► LADDER ► LADDER ► LADDER I - - - - 1 6. All work surfaces are 24" wide x 3/4"thick, _ I —'- -- _® melamine finished high density particle bd. 07 _ _ _ _ _ _ _ _ =\ with rounded front edge U.N.O., supplied TYPICAL °D ALIGN a0 TYPICAL TYPICAL L and installed by GC. BIKE LIFTS ABOVE, 3' 0" A207 3'-0" 3'-0" M 4 ih 4 I t TYP. FOR 3 - - ? T Slm - T - T T _ __ _ _Slm_ _ A207 9 ` 7. Center standards on walls whenever possible if O e J r T _ -- 3'-a" T-a' �\ I I \ distance between last standard and the �' a A207 - - - - - - -- - , ^ - - - - - - - - - + ___ _._____ __ A207 corner or end of the wall is less then 8". SPALLTORAG I r r4 I I 1zs 1za I 3 a 8. All walls to be PT-08 r * 3 f - FIXED SHELVING I A 9. All walls to have rubber base RB-01 \ ; I --� - - I A207 BY PIPP,TYP. I I The Shops at Evergreen Walk rgre LADDER TO ROOF,BYLL - - - - - - - - - - - - � I -- ( 4 A207 If \ y -slm- - I B Tamarack Ave 135 134 I .i TYPICAL SHELVING LEGEND I 1 Building C, Suite 75 4 _ - _ - _ _ _ - _ �_ _ _ _ ,,i� _ - _ ' _ _ _ _ _ `, _ _ �10 South Windsor, CT 06074 r_i ' GC TO PROVIDE& .- ;' I I STOCK ROOM ELECTRICAL V_ t� _ PANELS TYPICAL sex _ . �� INSTALL TACKABLE L J1 SHELVING ON STANDARDS Azo7 r Az11 I PANEL 12'Lx 6'H I O I BINS, RETURNS --- 0 ! 1 ELECTRICAL I PANELS - ; Checked By: Checker . . _ . ... _ _ _ _ _ ... FIROLLING SHELVING __ - 24"DEEP SHELVES .lob No: 06125.00 PROCESSING DESKSBY LL FIXED SHELVING TYP.OBEAN, 3 N, awl I& RECEIVING PALLETS A207 n STOCKROOM C.1Revk\125-base_IocalJen.rvt 219/2007 1:45:47 PM Gl C N t0 U O N a N E m m 00 ti O N s m 5 5 T a 0 U CEILING oL CEILING CEILING CEILING 1 8' - 08' - " - 8' - 0" I 8' - 0" 8' - 0" o - v o � o o � / 7 C 124 � m rn zG o o � PT ]05RB PT 05 PT 05 RB 01 RB 01Ar RB 01 \J II TEUCOM WEST 1 TEL/COM SOUTH �TEUCOM EAST 15 TEL/COM NORTH J 1/2" = 1'-01, ;J 1/2" = 1'-01, LJ 1/2" = 1'-0" T 1/2" = 1'-0" 5 5 1'-4"TYP. PT 05 CEILING _ _ CEILING n _ CEILING 5 _ CEILING n 8' - 0" 8' - 0" 8' - 0" V UPPER CABINETS �,' .'" .' ` 36"CABINETS 12"DEEP, PREFAB UPPER CABINETS WHITEWALL INSTALLED BY GC. SUBMIT CUTSHEET TO ARCHITECT. I ATTACHDT WALL WITH UTY STANDARDS A CHOREDD ED TO WALL EXPANSION BOLTS SHELVING WITH EXPANSION BOLTS � SHELVES WORK SURFACE � $ 1� T.O. SAFE RM ON STANDARDS T.O. SAFE RM ' 126 STANDARD I WORK SURFACE WORK SURFACE } PT 05 3' - 3 1/2/2" V ,a T - 3 112" ~ CPU SHELF F T.O. CPU SHELF 2' - 11, V � T.O. CPU SHELF n METAL CABINET BY L.L. BEAN SAFE BEYOND PT 05 2' - 1" RB O1 SAFE BY OWNER B.O. STANDARDS LV I 1' - 6" RB 01 � RB 01 n SAFE ROOM WEST ,�, SAFE ROOM SOUTH n SAFE OOM EAST 11 SAFE ROOM NORTH RB 01 1/2" = 1'-0" U 1/2" = 1'-0" 1/2" = 1'-01, 1/2" = 5 5 I CEILING n CEILING CEILINOG CEILING ® j — — — 8' - 0" 8' - 0" B CABINETS 36"TALL CABINETS, 12"DEEP PREFAB WHITE WALL BY GC.' CABINETS ` 41V `�T ��' � ' _ B.O. CABINETS n WORK SURFACE PT 05 PT 05 \ 5' - o„ I `\ `\ 1'-4"TYP. SIM ` 3 125 , SURFACE 126 , A209 T.O. SIT DOWN WORK WORK SURFACE ' CPU SHELF ' 2 - 6 KV _02.09_.07 _ _ISSUEFORBID I No By Date Description T.O. CPU SHELF j RB 01 STD I 2' - 1" L.L. Bean RB 01 B.O. STANDARDS c- CPU SHELF , , „ 20"HEAVY DUTY STANDARDS ¢n' RB 01 I RB 01 ANCHORED TO THE WALL WITH EXPANSION BOLTS WORKROOM WEST n WORKROOM SOUTH n WORKROOM EAST 7 WORKROOM NORTH ` 1!2" = 1'-01, U 1/2" = 1'-0" U 1/2" = 1'-0" r 5 C V-4"TYP. ' c l' I fCc I ` CEILING CEILING CEILING SHELF CEILING ' 8' - 0" 8' - 0" I 8' - 0" 8' - 0" /' ,' . 36"TALL 12"DEEP PREFAB ,' I ,' /' I 75 TamaThe pack Aves at rgreen Walk WHITEWALL CABINET BY G.C. , , 36"TALL 12"DEEP PREFAB ` SHELF HEAVY Building C, Suite 75 WHITEWALL CABINET BY G.C. � g ' South Windsor, CT 06074 DUTY WALL HEAVY DUTY STANDARD 11 11 11,, 11 . 11�1., 11 ���� ' B.O. CABINET �� �� ' I `�� ��,. ����,, WALL STANDARD B.O. CABINETS I BACK OF HOUSE - 5' - 0" PT 05 5' - " WORK SURFACE ! ELEVATIONS 1'-4"TYP. PT 05 I \` WORK ALL WALLS TYP. T.O. WORK I T.O. WORK 127 / SURFACE PT 05 SURFACE ® SURFACE 3' 2° 3' 2 I SHELF PT 05 i 1 Checked By: Checker CPU SHELF Job No: 06125.00 � SIM _— B.O. STANDARD6S B.O. STANDARDS I M �„ RB 01 Azos I I RB 01 TYP. RB 01 I t N RB 01V L A208 6'HEAVY DUTY STANDARDS ANCHORED TO 20"HEAVY DUTY STANDARDS ANCHORED TO i WALL WITH EXPANSION BOLTS. WALL WITH EXPANSION BOLTS n OFFICE WEST n OFFICE SOUTH n OFFICE EAST OFFICE' '1 NORTH _ --------- C:1Revit1125-base_localJen.rvt 2/9/2007 1:35:13 PM d C Uri 0 I N RESTROOM ACCESSORY SCHEDULE it URM BC BABY CHANGING STATION KAOLA, HORIZONTAL, RECESSED E 27, CH COAT HOOK BOBRICK B-682, MOUNTED TO PARTITION DOOR a) GB GRAB BARS BOBRICK B-6206, CONCEALED MOUNT, 1 1/4" t DIAMETER, STAINLESS STEEL WITH SATIN FINISH a a 0 GBS SWING UP GRAB BAR BOBRICK B-4998, WALL MOUNTED, PER CT STATE REQUIREMENT HD ELECTRIC HAND DRYER EXCEL 'XCELERATOR' SURFACE MOUNT MH MOP & BROOM HOLDER BOBRICK B-223X36, SURFACE MOUNT SCB SHOWER CURTAIN BAR BOBRICK B-6107X36, COORDINATE IN FIELD WITH SHOWER OPENING WIDTH BEFORE ORDERING SD CUSTOM SOAP DISPENSER BOBRICK B-8226, INSTALL IN LAV COUNTERTOPS � 6,d u oo � o SDW WALL SOAP DISPENSER BOBRICK B-2111 G v o E SNV SANITARY NAPKIN VENDER BOBRICK B-43500, RECESSED, 25 COIN OPERATION (on :1U n vgvq1i- 6o y o SND SANITARY NAPKIN DISPOSAL BOBRICK B-270, SURFACE MOUNTED TB TOWEL BAR BOBRICK B-550X24 TPH TOILET PAPER HOLDER BOBRICK B-76867, DOUBLE ROLL HOLDER NOTE: SEE SHEE A210 FOR ADDITIONAL RESTROOM REQUIREMENTS I 5 5 CEILIN0G CEIBLIN 8 p I CEILING 0LING � I 11 PT 05 `\ I ADA SHOWER STALL MIRROR BY G.C.sce PT 05 I CH CT 01 m` C� / 1,_4„ n a I \ CT 01 ALIGN SULLNOSE CT 01 GRAB BARS&BLOCKING ALONG TOP EDGE BULLNOSE sow IN WALL BY G.C. CH — �[fh ' GRAB BARS GB ti ALONG TOP EDGE &BLOCKING 2 6„ ❑ ❑ GB ces BY G.C. 123 1,_6' - ro o N TPH CT 02 ° N C CT 02 COT 02VE BASE N I I COVE BASE I to to rq- ��. n EMP. RR WEST ® EMP. RR SOUTH 1/2" = 1'-0" 1/2" = 1'-0" n 1/21' OEAST B 5 PT 05 1'-4"TYP. 8" CEILING CEILING n 36"TALL 12"DEEP I CEILING „ `1 — PREFAB WHITEWALL $ - 0 I $ - 0 CABINETS BY G.C. ' ` 8 - 0 T.O. 2ND SHELF — T - 3„ SHELVES ON STANDARDS ' PT 05 SHELVES ON STANDARDS -Jill / i REFRIGERATOR \ / 6'STANDARDS CASED OPENING I I � / , 4'-0 114" ANCHORED TO WALL CT 01 WITH EXPANSION BOLTS BULLNOSE ALONG TOP EDGE I IM MICROWAVE I I 3 �,qq,, HD I I A209 OPEN TO Ifl W WORK SURFACE PREFAB BEYOND WHITEWALL BASE ; T.O. SIT DOWN PT 05 CABINETS BY G.C. , 2' - 6" - KV 02.09.07 ISSUE FOR 81D o wry. 122 ------------ No By Date Description T4 B.O. STANDARDS L.L. Bean M CT O2 COVE BASE — _ RB 01 1 - 61 r \I r APPLIANCES BY OWNER RB O1 j n EMP. RR NORTH LOUNGE WEST n LOUNGE SOUTH U 1/2" = V-0" U 1/2" = 1'-0" ,< �T ' 5 B c, PT 07 4" 4" V-4"TYP. 4" n - oL CEILING n CEILING — 81 0,t I — — 8, 0,t T.O. SHELF 2 The Shops at Evergreen Walk TUPPER CABINETS — — 6, - 7„ i 75 Tamarack Ave VENDING MACHINE, Building C, Suite 75 SHELVING ON STANDARDS 1 BY OWNER I South Windsor, CT 06074 I T.O. STSHELF _ i WALL MOUNTED STANDARD, SEE ELEVATIONS FOR LENGTHS I 6' HEAVY DUTY STANDARDS BACK OF HOUSE - ANCHORED T® WALL WITH ELEVATIONS & 24"D X 3/4"THICK MELAMINE FINISHED DETAILS (CONT'D HIGH DENSITY PARTICLE BOARD 123 \ / WITH ROUNDED FRONT EDGE T.O. SIT DOWN WORK SURFACE O PLYWOOD 2 - 6 I I PT 05 Checked By: Checker 16"D X 3/4"THICK MELAMINE FINISHED __ T.O. CPU SHELF \` / B:O. STANDARDS .lob No: 06125.00 r „ r BASE CABINETS HIGH DENSITY PARTICLE BOARD 2 - 1 ` 1' - 6" no n WITH ROUNDED FRONT EDGE ` B.O. STANDARDS � 15 El ' ` A603 ASE TYP. RB 01A209 RB 01 n TYP. WORK SURFACE SECTION 2 LOUNGE EAST n LOUNGE NORTH 11211 = 1'-0" 1/2" = 1'-01, C:1Revit1125-base_IocalJen.M 2/9/20071:32:09 PM - _._.. -- _-- -------- -------- --------- - - - -- — --- - ._ . . _ __ . .- - - - ------------------- -__.. . _ - - --._ . .-- -- --- - .. __ _ - _._.... - - -.._...- - - - - --- -- - I RESTROOM ACCESSORY SCHEDULE X BC BABY CHANGING STATION KAOLA, HORIZONTAL, RECESSED w w w CH COAT HOOK BOBRICK B-682, MOUNTED TO PARTITION DOOR I ¢ C w NOTES T v X 1.THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE,OR OTHER NON-GLARE FINISH.CHARACTERS AND SYMBOLS SHALL CONTRAST GB GRAB BARS BOBRICK B-6206, CONCEALED MOUNT, 1 114" I m W>-cow w U w WITH THEIR BACKGROUND,EITHER LIGHT CHARACTERS ON DARK BACKGROUND OR DARK CHARACTERS ON LIGHT BACKGROUND. DIAMETER, STAINLESS STEEL WITH SATIN FINISH ro m n w to Of 2. IDENTIFICATION SYMBOLS ARE TO BE CENTERED ON DOOR 60"ABOVE FLOOR AND ARE TO BE DISTINCTLY DIFFERENT FROM THE DOOR IN COLOR AND o W w w o w 0 CONTRAST. GBS SWING UP GRAB BAR BOBRICK B-4998, WALL MOUNTED, PER CT STATE N o 0 O g Q z FAUCET REQUIREMENT m¢ ¢ ¢ MOP&BROOM 3. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR. MOUNTING HEIGHT SHALL BE 60"ABOVE THE FINISH FLOOR TO THE CENTERLINE OF THE �Q - HOLDER SIGN• HD ELECTRIC HAND DRYER EXCEL 'XCELERATOR' SURFACE MOUNT MO w _ 4. LETTERS&NUMBERS ON SIGNS SHALL BE RAISED 1132"MINIMUM, UPPER CASE,SANS SERIF OR SIMPLE SERIF TYPE AND SHALL BE ACCOMPANIED WITH I O GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8"HIGH, BUT NO HIGHER THAN 2". MH MOP & BROOM HOLDER BOBRICK B-223X36 SURFACE MOUNT N ' . 5.ADA SIGNAGE PROVIDED BY CONTRACTOR. SCB SHOWER CURTAIN BAR BOBRICK B-6107X36, COORDINATE IN FIELD WITH N A 6. PICTORIAL SYMBOLS SIGNS SHALL BE ACCOMPANIED BY EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM.THE BORDER SHOWER OPENING WIDTH BEFORE ORDERING g of F DIMENSION OF THE PICTOGRAM SHALL BE A MINIMUM OF 6"IN HEIGHT. w w w w o 7. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 SD CUSTOM SOAP DISPENSER BOBRICK B-8226, INSTALL IN LAV COUNTERTOPS O Z� LLO AND1:10. 2 v Ow z 8. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ.THE MIN.HEIGHT IS SDW WALL SOAP DISPENSER BOBRICK B-2111 w ¢ a 550 MEASURED USING AN UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED.FOR SIGNS SUSPENDED OR PROJECTED ABOVE THE FLOOR IN COMPLIANCE _ o U=4 * ¢ m z z a o o ¢U_ = O m WITH ADAAG SECTION 4.4.2,THE MIN.CHARACTER SHALL BE 3". SNV SANITARY NAPKIN VENDER BOBRICK B-43500 RECESSED 25 COIN OPERATION v E c� to to a: m °o o .6 THE INTERNATIONAL SYMBOL OF _ o S 9.CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE ° -a u N N REGULATIONS. DOT DIAMETER SHALL BE.059", INTER-DOT SPACING.090",HORIZONTAL SEPARATION BETWEEN CELLS .241"AND VERTICAL SEPARATION ACCESSIBILITY SHALL CONSIST OF A WHITE SND SANITARY NAPKIN DISPOSAL BOBRICK B-270, SURFACE MOUNTED v tj N v n MOUNTING HEIGHTS FOR TOILET ACCESSORIES & PLUMBING FIXTURES BETWEEN CELLS.395". FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN TB TOWEL BAR BOBRICK B-550X24 U " a o r FEDERAL STANDARD 5958. � � �ox tn TPH TOILET PAPER HOLDER BOBRICK B-76867, DOUBLE ROLL HOLDER B Pr o7 4 CEILING 8' - D" PT 05 MOP&BROOM HOLDER ` PT 05 PT 05 MOP SINK FAUCET - PT 07 B A PT 05 121 I MOP SINK WATER HEATER ,' WATER HEATER RB 01 RB 01 o I RB 01 MOP SINKCY ! ! z I I Entry Level n UTILITY ROOM (W) UTILITY RM SOUTH L8 `y - ,�L n UTILITY RM EAST n UTILITY RM NORTH V 1/4" - 1'-0" U 1/4" = 1' 0" 1/4" = 1'-0" U 1/41 = 1'-0" , " \ I / CH .1 ' 0" \ t GWB -02 8 \` I O W5 6,_8„ 4'-6" EQ EQ - l I > / SHELF BY OWNER CEILING f- �1 \ O W5 OR3 CH 8.0„ OR3 / pR \ F9ASHELVING&STDSGWB PT-02- - - - - - - - - - - � FBO, IBGCPEN TO OW5a SALES _ PT 05 \ \ ..\ •,\ \','. \ \. \\ \ \ 1 1 M \\ — EQUIPMENT BY OWNER PT 05 CH 8'-0" \ CH 15 0 I 1 m _� EQUIPMENT FBO _ GWB PT-02 GWB PT-02 RB 01 PT 05 RB 01 (�zo RB 01 a RB 01 I I I I ' " F \ EQ EQ \ OR Entry Level 0R3 � a 4 - _ - — OF 0 wH MONOGRAMMING (W) n MONOGRAMMING (S) _ MONGRAMMING (E) MONOGRAMMING (N) 1/4" = 1'-01, 1/4' = 1'-0" ," 1/4" = 1'-0" 1/4" = 1'-0" EQ I I EQED j -- - I w I \ OR I \ OR3 \ R1 `v \. O W5 a B \ b 1 I iD LL BEAN'S FC 10"2'-1 1/4'z'- 1 1/4" TO PROVIDE 4"WD TRIM PT 08 iy CH 8'-0" _ MIRRORS;GC CEILING w O W5 GWB PT-02 TO PROVIDE m WD 09 PT 08 BLOCKING PT 03 PT 06 WD 06 GWB PT-02 M I DROP ON GB ` TOILET PARTITIONS,TYP. 4"WD TRIM O W5 05, s' PT 03 PT 03 4"WD TRIM GB �m �m GB �� Im — W 09 PT 08 _ - I ' � it :I . , � I ! �; ! ; I I . � ! . o0 PT 08 Ii ! i ' WD 00 PT 08 - r :i, ;. _ ---� ,_..., 11 "I -=I ' WD 09 PT OS m Bc - _ . r — _ : _- RCP - RESTROOMS, MONOGRAMMING & UTILITY CLOSET 2 1/2"WD TRIM i 21/2"WDTRIM _ 1___L ' - - _ - _= CT 01 _ „ I i r� TPH .. 1/4" — 1 -0 WD 09 PT 08 I I I ' I i : _ �' Entry Level107, n B A MEN'S RESTROOM W MEWS RESTROOM S ST 01 MEN'S RESTROOM E)f ST 01 ST 01 0' - 0" n O n O n ( n MEN S RESTRO M (N) 1/4" = 1'-0" U 1/4" = 1'-0" 1/4" = 1'-01, 7'-6" 2'-6" 3'-5" 2'-11" I GB -- - - - -I - - - T EQo EQ ` `E —EQ' 3B 6 TO PROVIDE PULL DN GB \ ' 10"2'-1 1/4'2'-1 1/4" TOILET ROOM o MIRRORS,GC ` \ \ ! \` \ \, '� KV_ 02.09.07 ISSUE FOR BID _ '\ 4"WD PARTITION,TYP. _ _ CEILING \\,y \ \ \. , \" \ `\' _ _ BLOCKING PROVIDETO PT 03 DROP DN GB pT 03 WD 09 PT 08 8' - 0" ° \� TPH' ' \\ Bc 3'-2" 1'- 10" m No By Date DescripUDn 5'-8" I I 4"WDTRIM \\ • PT 03 PT 03 4"WD TRIM r \ 1 _ _ J 1n L.L. Bean ' II WD 09 \ 4"WD TRIM GB - , 2A 1 p PT 08 WD 09 PT 08 ' M1 . mESS H L- _,_T:.. ,. : 2112"WDTRIMr=I 'T SD- -- � ' : I � : I , , ' ; � I � , . 08 __ ' � ,. ,' O , . : ..( /. ..:. _I.. H. _ r-- - ' f I '' e 2 1/2°WDTRIM m ^ r p 3 N RESTROOM : __. ry 21/2"WDTRIM r r r 1 r t —�—L - ' --�- \I SIM ST 01 ST 01 WD 09 PT 08 - co ST 01 I� _�.. t I� I i : I' ' I ! I i _ _ Entry Level °0 1 WD 09 PT 08 ST 01 0' - 0" s A509 3 A210 1 O9 _WOMEN'S RESTROOM (WEST) WOMEN'S RESTROOM (SOUTH) WOMEN'S RESTROOM (EAST) WOMEN'S RESTROOM (NORTH) :1 ` ° 1 1 1/4" - 1'-0" U 1i4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" P1�LL DN GB GB i I 4 UTILITY CLS v _ THCo _ t �~ 3B ! A 121 O O � N t i A I aD I 4 1 A210 1 \\ CD 2 !, ' O ' S _ _ _ n _ i HULOW DRINKING ////,� \\ \ ` WOM�N'S RE T.ROOM FI 5 A210 3 FOUNTAIN GWB. .. CLG I (J, t-- \ — wH — ` \ _TPH SND Ci t 4 —7 E _ — 15' - 0- 0" 1 �� \\ \ O w M The Shops at Evergreen Walk HALL 75 Tamarack Ave PT 07 NO RAM NG - \ w r Building C, Suite 75 ® South Windsor, CT 06074 HULow I PT O8 I PT O8 I 1zo SND W ® ! 7A RESTRMS, UTIL RM, & PT 08 DRINKING FOUNTAINS PT 08 m PT 06 �, w m I MONOGRAMMING RM - WD 06 0 7 A210 1 6 ji s Az10 I ENLARGED PLANS 9 AND ELEVATIONS ' PT 08 DRINKING FOUNTAINS \\ PT 08 i A509 Checked By: Checker PT 08 1 115 Job No: 06125.00 \� - - - - - PT 06 PT 06 PT 06 PT 061 06 WD 06 WD 06 WD 06 WD 06 M ® PT 08 3 3A N 06 _ Entry Level Entry Level I Entry Level 7 vz" a'-o° 12'-6" 0' - 0" 0' - 0" OF - OF, A21 0 _o„ I 18,_ 1,: r-z' � W) HALL (S) n HALL (E) n DOOR TO EGRESS HALL n Restrooms, Utility Closet, Monogramming Room 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" C.\Revft1125-base IDcalJen.rvt 2/9/20071:48:46 PM U C N N l6 U O N Q T al E m `m m 0 N L .0 T a 0 ' U Sim 12 A502 12,_p' , 3 PT 05 1 -0" A801 PLATFORM 7'-11 1/4" TOP OF WALLS 3'-6"MIN.ABV. PLATFORM �U ��Isrs� SEE ELEVATIONS FOR OVERALL HEIGHTS o 6 z �I`J� s w o �� o WD 06 � � No 1 Im c utic OPEN TO o STORE BEYOND PT 06rn ` 1 STAIRS O ¢� n Min aw 3 1 FRONT COUNTER RB 01 WD Og _ w WD 12 1 (SEE SHEET A508) 1 - WD 11 IIIIIIIIIIIIIIIIIIIN SEE 10/A502 FOR MILLWORK INFO *A108 n OUTSIDE BIKE SHOP WEST �, BIKE SHOP INTERIOR AT COUNTER d 2X2 TS W/ BASE PLATE TO SUPPORT Sim o WM 01 12 RAILING 2"X2"TS UPRIGHT WELDED FLUSH WITH ` FRONT OF TOP&BOTTOM RAILS.WELD 1/4" IT-7"� PLATE TO CLOSE TOP OF UPRIGHT (TYP) — — -_ 112"STL. ROD WELDED STAIR BEYOND PRTO TOP& BOTTOM RAILS.WIRE MESH 2X12 JOISTS 9'-0"�WELDED TO ROD 9'-0" �TFORM 4"TRIM PLATFORMA Fps _ _ _ _ _ _ _ _ _ WIRE MESH(TYP) 11 11 1�9 \ SOT.OFJ054T \ CEILING _ WD 06 PT 06 8' - 0" EDGE OF I I I BELOW(TYP)LL Q BEADBOARD PT 05 -L PT 05 III I I I \` l I UPRIGHTS WELDED TO Z \ STL BASE PLATE BOLTED INTO TOP 143 RB 01 \ RB 01 BIKE SHOP 2ND FLR STORAGE PLATE OF WALL BELOW � Z 14 1/4" = 1'-0"I I i i 51/2"TRIM I i I � ill lily i li WD 06 PT 06 � Entry Level _ I SEE 10/A502 v 0' - oil 135 FOR MILLWORK INFO FIXTURE O will BY OWNER FIXTURE BY OWNER n RETURNS -WEST n RAILING DETAIL @ BIKE SHOP n OUTSIDE BIKE SHOP SOUTH n BIKE SHOP INTERIOR WEST T-11"TYP. 4'-0"TYP. U 1/4" = 1'-04, ` ' 1 112" = 1'-0" LJ 1/4" = 1'-0" 1/4" = 1'-0" l Sim 2x12 JOISTS(TYP.) 13 WD 09 - A21z - - - i ill • ; II -- ', I � 1 N 5 WD.JOIST PT 05 Ls I Ili " iiII ' o : I � 4"TRIM PLATFORM PLATFORM S OF CEILING 11 1 WD 11 WD 06 PT 06 8' - 0" 1 : BOT.OF JOISTS I, II WD 06 I I I I VISIBLE FROM WD 06 BELOW BEADBOARD OPEN TO BIKE PT 06 OPEN TO PT O6 ' STORE WD 10 PT 08 SHOP BEYOND BEYOND L6 OPEN TO I ! T- STOREBEYONDFRONT COUNTER— — —— — — — ' Iliii ' i I ' Ilill Ili 5 1/2"TRIM (SEE SHEET A508 OF STAIRS COUNTER RB 01 Entry Level WD 06 PT 06 ( ) (SEE SHEET A508) EXPOSEDjpA I I 0 - 0 t 30 E SEE 9/ 502 FOR MILLWORK INFO 9 i ! I I I ! lir A508 O j l 1 1 y_g q _p p_g° L6' n RETURNS - SOUTH n OUTSIDE BIKE SHOP @ COUNTER n BIKE SHOP INTERIOR SOUTH i i �7 1/4" = 1'-0" I U 114" = 1'-0" 1/4" = 1'-0" II ! , � I O R3 Q R3 r;' ''. -— =--- - --- - - CH 8,_0„ ;' 13 Sim GWB PT 08 A212 RCP - BIKE SHOP COUNTER BELOW CH 8'-0" 10 _ KV 02.09.07 ISSUE FOR BID GWB PT OS 1/4" = 1'-0" - -- - --- No By Date Description - -- --- ------- --------- 2X12 JOISTS � L.L. Bean_ O COI A C � _S1 — 9'-p" PLATFORM 4"TRIM 4 -' CEILING -- '- -- 7'-1 WD 06 PT 06 j� - '--- � r ,.�,;' i PLATFOR 80T.OF JOISTS , � �✓ �'' 8' o11 MTL WALL STANDARDS 2 0 O.C. I � I i { III : III I �i A211 l � a BEADBOARD „ 3'-21/2" 9WORKTABLES, i �•� n BYOWNER WD 10 PT 08 "'�, ---- - PT 05 WORK TABLES,ETc 1 II II i ( j I FRONT CASH WRAP,FBO, I' I IBGC, SCRIBE SIDES&TOP � - ------- T7ri4 O WALLS RCP - RETURNS I;! 8 1/41' = 1'-01, RB 01 UP I 1 A801 III( II I I I 51/2"TRIM =i 17 RISERS till. l. WD 06 PT 06 rh Entry Level il FIXTURE BY OWNER 134 FIXTURE BY OWNER E SEE 9IA502 FOR MILLWORK INFO. 9'-0„ 6'_7"VI F v "1 1 N n RETURNS - EAST n OUTSIDE BIKE SHOP EAST n BIKE SHOP INTERIOR EAST 1 7 A211 ^p`""..'` U 1/4 - 1 -0 I 1/4 - 1 -0, U 1/4 - 1 -0 yl n 1 2 i- _. 'rr; n — , u � n — , n � n — , n - II 12 Sim --- sim c- -- __ __ �� 1 5 A211 6 .� The Shops at Evergreen Walk 75 Tamarack Ave 12'-7" 3 1 o A212 —1 �I 14- , \ Building C Suite 75 -"" a _ 1 South Windsor, CT 06074 135 7 A211 9 134 11 I _ II _ BIKE SHOP & :n o 50 2X12JOISTrr______ I 1 / N -1 II ( 1 / ` RETURNS - ENLARGED 4"TRIM u PLATFORM PLATFORM it 1 PLANS AND CEILING WD 06 PT 06 i A _ — — 1 — NOTE: _ BUT.OFJOI5T5 BACKCOUNTER 1` -ram 1 // 1,</ / ELEVATIONS `t 7'-11 1/4" i; ]ji- b `1 8' - 0:, i I I I _ .__ _.___._.. _ .__. I - MTL WALL STANDARDS FIXTURE ( / i' ` �{ IIj RB �1 PT 05 i PLASMA SCREEN I I I I I i I l i I III BEADBOARD FIXTURE BY OWNER 1A3 , � /�' BIKE COUNTER' i Checked B Checker FBO, INSTALLED ` ' "' I ON AL\WALLS IN CLOSET WD 06 BY OWNER L _ _ 13 a m/���d (SEE SHEETA507) 1 PT 05 Job No: Y 06125.00 { I I' I WD 10 PT 08 130 — —:-,..T-- PT 06 ., / a 12 L It :L -------------- BY OWNERS ! � I , I ____.. -OPEN TO_-- VENDOR, PWR _ III j l l j ------------------ STAIRS o / &BLOCKING 0 1 I' • I - �i—I "BEYOND. : 2,_3„� BY GC n I { I ( 1 BACKWR4P FIXTURE FBO, ( "I= - GC TO INSTALL EYEE 1 ILL I ! I • I I L ' IBGC, SCRIBE SIDES&TOP TO 6" 8'-0" " T_ --: HOOKS IN CASED RB 01 8 * 1 I { I I i WALLS I OPENING @ 2'-6"AFF FOR _ I j I I I{ I I I I 5 1/2"TRIM CHAIN/SIGN BY OWNER ( : { IIIII. I III � i! WD 06 PT 06 A211 Entry Level m SEE 9A2 11 /A502 FOR SEE 10/A502 0' - of MILLWORK INFO F R ILLWORK I F, n RETURNS - NORTH n RETURNS ENLARGED PLAN O OUTSIDE BIKE SHOP NORTH n BIKE SHOP INTERIOR NORTH 1 BIKE SHOP ENLARGED PLAN 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" CARevit1125-base_local_jen.rvt 2/9/2007 1:29:05 PM I N I � 2 1 U I N Q I ! ! T 4 PEELED LOG WD 12 WD 12 WD 12 WD 11 I WD 11 m N GROOVES GROOVES FACING DOWN ! r WD 11 FACING DOWN T • • - - : ,-:- � FRT STUD S STE GROOVES FACING DOWN " "' " ' u. .' ONTO EXISTING METALci i-•..,.. m eu•••ae-i{�'?tit it'. t ;u,�} rr•} ';}}}'t `7r hr.}}mr - .. ,. ... • • ' rr. rr.� - •rrn •- � STUDS I 8"DIA. PEELED LOG 13 O 2X12FSCFRT F> ?FrF4i83 -r• •: �•�r�rj} 3/4"PLYWOOD DISCONTINUOUS WD 12 A212 WD JOISTS(TYP.) FRT 2X12 BLOCKING EDGE OF 2X12 FRT WD. BAN JOISTS JOISTS IN CLOSET THRU BOLT I BEARING ON TOP PLATE ON 3/4"V-GROOVE OF PARITION(STAGGER I FRT 2X12 LEDGER PLYWOOD D I�' I WITHCASHWRAP FASTENED TO IWD 11 JOISTS) SISTERED WD.STUDS (GROOVES FACING DN) WM 01 RAILING (rYP) I V 2X12 FRT WD JOISTS I EDGE OF 2X12 FRT WD. JOIST HANGER (TYP) BEARING ON TOP JOISTS IN CASH WRAP / a PLATE OF PARTITION JOIST HANGER(TYP.) B o . C ^yUy vN � O v CAULKkI T ti vbi nt "' PLYWD. FINISH IN CLOSET �� w WD OH GWB WALL FINISH / n . o WD.TRIM y v o -C! ti Pvt f-0P. F4 LADDER I � X SECTION OF 42" SPEED RAIL(SIM.TO OPEN ABOVE OFFICES IN TO BLW. 16 PEELED LOGS AT CASHWRAP DETAIL n CASH WRAP JOIST DETAIL 14 JOIST CO NECTION @ LANDLORD'S WALL STOCK ROOM) 4„ = 1 -0" 3" _ 1'-O" I I I I I I 1X2 STEEL TS SECURED INTO BACK OF PEELED s LOGS 1„ WD 12 n CASH WRAP PLATFORM PLAN WD 11 U 1/4" = 1'-01, D GROOVES FACING DOWN WM 01 FRT WD STRAPPING PEELED LOGS VARIED HEIGHTS WELDED TO TOP @ 2'-0"O.C. — — — — — — — — — — — — — — — — — — — — — — — TOP OF POLE TO BE 13'-0"MIN TO / &BOTTOM RAILS N 16-0"MAX .= 13 2X12 FRT WD JOIST A212 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" / FASTENED INTO FACE OF STUDS — WM 01 RAILING(TYP) / Af 2x4 FRT WD STUDS CAULK 1X2 STEEL TS SECURED INTO BACK L6 L L L6 IL6I IL6I OF PEELED LOGS j WD.TRIM OPEN TO OPEN TO OPEN TO OPEN TO 8"D PEELED LOGS T WD 12 1" f WD 10 CASHWBEYOND BEYOND CASHWRAP BEYOND AP BEYOND i4'-0" 4'_0" 4'-0" WD 11 ' - V GROOVES OF GROOVES FACING DOWN ODG WN rxr i WD 11 W3 Hw3 Lw3 W3 VISIBLE FROM BELOW n RAILING AT CASHWRAP n CASH WRAP END JOIST CONDITION n FRONT OF CASHWRAP ` n OPEN a L-6/ TO ABV. L6/ ` i y 0" 2'-0" .C.TYP. 11'-6"XZ'-3"MTL LADDER I WD 08 I O.C. .� PT!02 8 PT 02 TYP. 14 / =WD08 Exisrc RCP 1ASH WRAP ROOF DRAIN EXISTG ROOF DRAINS MTL WALL STANDARD PT 02 I PT 02 MTL WALL WD 08 PT 02 STANDARD i RB 01 I RB 01 I _ _ _ � RB 01 RB 01 I fN 02.09.07 - ISSUE FOR BID_--_ _ ' No By Date Description 1a2 L.L. Bean A212 n CASHWRAP CLOSET NORTH n CASHWRAP CLOSET WEST CASHWRAP CLOSET SOUTH 1/4 1 -0 n n CASHWRAP CLOSET EAST 11 = Eo EO EO- - - - - - - - - - — — — - - - - - 1 ALIGN C.L.OF PEELED LOG W/ " o INSIDE FINISH FACE OF WALL D -v 14 A502 ' r- - - r�- -Ir - - - - - - - - - - - - - - - - - - - - - - - / I Ilr- - - - - - - - - --I F- - - - - - - - - - �I '' • , a. , I III r WALL CONTINUES TO ro I III UNDERSIDE OF DEC 13 Sim MT 01 RAILING v � — - - I- ---- L - - L- - - - -1 - - 1 - - - - � - - A212 TOP&BOTTOM RAILS 13 Sim o> CASHWRAP&BACKWRAP 5 A212 3 a, BOLTED TO WALL A212 TOP&BOTTOM RAILS FIXTURES BY OWNER WM 01 BOLTED TO WALL 4 8"D PEELED Locs 11 METAL AD WD 12 24'-6° The Shops at Evergreen Walk METAL LADDER Sim RAILING WD 12 WD 11 - - - - - - - - - - - - - - I 4"TRIM 15 4"TRIM WD 11 8"D PEELED LOG 75 Tamarack Ave � A212 � � I Building C, Suite 75 WD 06 PT 06 , 2x12 FSC FRT WD 06 PT 06 South Windsor, CT 06074 WD RAFTERS 9 CASHWRAP WMM15 / Sim 12 III I � � � � , ; � �, � it it i t.l. . 11l_� ' III ' I 4��TRIM � A212 � g A212 I r, ! A212 I + j I I I WD 06 PT 06 ( I I BEADBOARD 1 11 ' I ! I I A212 ill I ! I ' 1 j I I I I I I I I A212 WD 10 PT 08 i I I I I I I I I I I I i I I I. I i I I I I II ' r I I I , I �62 SECURITY KEYPAD A212 6 BEADBOARD A212 0° OPEN PT 08 � 9 / I I I l I I I I I ( III I I III �I I j I I ! I m OPEN ( I I j l BEADBOARD / n 5 1/2"TRIM j 1 1 I I ! I I I !f I I I ! I I v Checked By: Checker jl I ' I F OSNSTALEDN i II I i II III II I !o I j11 I , I I uml mr IMWD 06 PT 06 L— I BY OWNER'S I Job No: 06125.00 5 112"TRIM I (M03 ' ' 51/2"TRIMVENDOR, PWR& i ; I it I WD 06 PT 06 II I I III BLOCKING BY GC PT 06 ter\ A503 SIM 142 r �5 �F ASH WRAP WEST n CASH WRAP SOUTH CASH WRAP EAST = 1'-0" n 1 CASH WRAP ENLARGED PLAN 1/4" = 1'-0" = 1'-0" 1/4" = 1'-0" C.1Revit\12 - I - - A212 - ------._.. _.. ----- - - --- - - --- ---- --------- _.- .. -- --— ---- - - -------- -- - --._._ . _ .._..._ __ _. _.._. __._ ase_oral en.rvt I U 2 N N 'U O 41 Q T N E O) N Q1 O N L O) 'C a 0 U U 4 Y O N O Urn 4 C <h bA 2 c a qq a ! " mom o3 R ,[s i i 5 4 3 GC TO INSTALL GWB PT 02 AROUND PT O2 CLERESTORY WINDOWS BETWEEN TOP OF CLERESTORY STEEL&UNDERSIDE OF 1 1 ROOF STRUCTURE(TYP.) I I I I I I 1 UNDERSIDE OF CLERESTORY n 1 36' - 11 1/2" PT 02 TYPICAL ON ALL BAR JOISTS&HVAC DUCTS TO BE COLUMNS&BEAMS PT 07 PAINTED OUT TO MATCH THE CEILING, I I I j UNDERSIDE OF TYP. IIL _ 1 _ LOWER ROOF LINEOF SPRINKLER COVERAGE - - - - - - - - - - - - - - - — — - - - - - - - - - — - - - - - - - - - - - - - - - - - - - - - - — - - - - - — — — I I I 1 I 1 I lb IS IMISE"911i 'L 1 I 3 Sim 1 1 ap Aa �P i 0 I i 1 1 1 1 Entry Level I1 1 — o, - o„ r r - - - - -�—I_ - - -- - i r - -I—I- - - r - - - 11 - - - i L - - - J L - - - - - - - - - - - J '- - - - - - J 1 j 2�g Section East 1/8" = 1'-0" i i I F E D C GC TO INSTALL GWB PT 02 AROUND B A CLERESTORY WINDOWS BETWEEN TOP OF CLERESTORY STEEL&UNDERSIDE OF ROOF STRUCTURE(TYP.) - KV 12.28.06 Progress Drawings No By I Date Description I I I I UNDERSIDE OF CLERESTORY L.L. Bean� '; 36' - 1- 11 112112"-V E BAR JOISTS& HVAC DUCTS TO BE I PT 07 TYPICAL @ ALL COLUMNS c; } PAINTED OUT TO MATCH THE CEILING, &BEAMS UNDERSIDE OF TYP. _ _ LOWER ROOF — - - — - - i LINE OF SPRINKLER COVERAGE — — — — — — - - - - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I - - — — — — — — — — — — — — — — — — - - - - — — — — — — — — — — — — — — — — — — — — — — _ f L The Shops at Evergreen Walk 75 Tamarack Ave I Building C, Ste 75 South Windsor, CT 06074 _ _ Entry Level 01 - o" BUILDING SECTIONS L _ _ _ _ _ _. __ - - - J Checked By: Checker I Job No: 06125.00 A3 0mok 1 I I 1OBuilding Section North 1/8' = 1'-0" I 6Revit\125-base-Iocalijen.nrt 2/9120071:44:03 PM ------ -------- 21'-7" c VESTIBULE ROOF VESTIBULE ROOF B.O. CURTAIN Ida WALL 5 A402 FALSE ENDS FALSE ENDS 12 - 0 FRT WOOD FASCIA ON ALLEDGES,TYP. T N E STEEL WITH STEEL WITH WOOD CLADDING v WOOD CLADDING v m �— FRT PLYWOOD DECKING o N STOREFRONT BY GC STOREFRONT BY GC a rn a 0 U BREAK METAL BY LL � BREAK METAL / CURTAIN WALL BY LL CURTAIN WALL BY LL / VESTIBULE COLUMNS _ _ _ _ _ _ _ _ _ _ _ _ _ _ rn A403 0 io io U VESTIBULE COLUMNS 71 a nn u N G BOLLARDS FOR 2 o 0.POWER ASSIST DOORS MEMBRANE ROOFING ON u o v DN HP TAPERED INSULATION w eEo 1/4"SAFETY GLAZING ? � o ' 0Gr � � � oa h 1"INSULATED SAFETY GLAZING SAFETY GLASS ON GLAZING t` 1/4"SAFETY GLASS LP Entry Level O' - O" SCUPPER WITH DOWNSPOUT n VESTIBULE - EAST n VESTIBULE - WEST n VESTIBULE ROOF PLAN U 1/2" = 1'-0" U 1/2" = 1'-0" 1/2" = 1'-O" FRT WD- FASCIA ON ALL EDGES,TYP. STEEL TUBE WITH WOOD CLADDING STEEL TUBE BEAMS IN FRT WD- CLADDING,TYP.FOR 3 VERTICAL I VESTIBULE ROOF FALSE END FALSE END,TYP. FOR 4 i FALSE END VESTIBULE COLUMN VESTIBULE COLUMN / / / _ FRT T&G CEILING WD-_ /. 5'-3"CENTERED ON DOORS 8'-0" 5'-3"CENTERED ON DOORS C CHANNELS WITH WOOD CLADDING L.L. BEAN PADDLE ATTACHED TO DOORS ' I ON PULL SIDES WITH I f� ' TWO BRACKETS,TYP. 1"INSULATED 1"INSULATED SEE SPEC FOR DETAILS. ' o SAFETY GLAZING SAFETY GLAZING 60 TYP. EXTERIOR \ TYP.@EXTERIOR r� m co ACCESSPANELFOR o RECESSED HEATING UNIT 1 2 9 8 9 7 1 2 Entry Level eve_I n 0' 0" V 101 102 DOWNSPOUT n VESTIBULE - SOUTH— 2 VESTIBULE RCP 1/2 — 1 -0 A401 --— I(V 02.09.07— ISSUE FORBID C.7 4 C.2 No ey Date Description STEEL TUBE W ITH 19'-2"CL OF TUBE STEEL TO CL OF TUBE STEEL L.L. Bean WOOD CLADDING - 18'-10"INT FACE LJ� ,f o FALSE END n VESTIBULE ROOF I I . i FALSE END'A' MLLn I I iv N ALN WITH STEEL Y LNT. BY GC,TO r i\I NOTE:ALL VESTIBULE TYP.ON BOTH SIDES VESTIBULE COLUMN FRAMING&DOORS TO MATCH KAWNEER: ' n ANTIQUE BRONZE i LI w TUBE STEEL COVERED IN BREAKC CHANNELS WITHBOLLARD 131 WOOD CLADDING METAL TO MATCH SF FRAMING, BY GC 1 CURTAIN WALL,BY LL POWER ASSISTDOOR CLOSERS ' ` L i _ 4 A402 2 i�VESTIBULE COLUMNThe Shops at Evergreen Walk ve co BOLLARD FOR POWER _ _ _ _ Building C, Suite 75 ASSIST DOORS N N LINE OF VESTIBULE ROOF ABOVE South Windsor, CT 06074 — @ PADDLE I HANDLE i VESTIBULE DETAILS 0 1/4"SAFETY GLAZING iv I - I/°� i @INTERIOR TYP. � •� �•1 I N � —!—N 1 / \ 7 ; A402 Checked By: Checker 7'� g - - _ - - -_- - - - - - - - - - -_- -- - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - \ Job No: 06125.00 Entry Level_ 0',-- 0" i 104 103 5 6'-0" 2" 1'-5" 2 6'-0" �2 2 _1 [A401 A401 BOLLARD n VESTIBULE - NORTH n VESTIBULE - ENLARGED PLAN 1/2" = 1'-0" U 1/2" = 1'-O" C:1RevitlS W indsor\125-base-local-sh(Recovery).rvt 219/200712A5:08 PM U C N m lII U O N Q N m all rn iu m 0 N t rn C a 0 U CURTAIN WALL BY LL MEMBRANE ROOFING ON TAPERED RIGID INSULATION ALUMINUM STOREFRONT ATTACHES TO PLYWOOD BLOCKING,TYP. j CAULK JOINT FSC FRT PLYWOOD DECKING — SEALANT p METAL FLASHING BY GC a N 2 o o o � METAL FLASHING b y F 1 X CEDAR CLADDING,TYP.ON ALL v B.O. CURTAIN - - 4slDes a o[ p TUBE STEEL CLAD WITH WALL __ 7"C CHANNELS @ 2'-0"O.C• HSS 5X5X.500 ° o x 5 BRAKE METAL BY LL 12, 0„ — _......--- ..- ._...... .. — m o s K FRT WOOD FASCIA N w MEMBRANCE ROOFING ON TAPERED RIGID INSULATION / UNDERSIDE OF 3/4"FSC FRT PLYWOOD 3/4"FSC PLYWOOD BLOCKING FSC FRT 3/4"PLYWOOD B.O. CURTAIN VESTIBULE FRT T&G CEILING WALL CEILING _ - 12' - 0" ® v IV - 23/41' N _ cl fV UNDERSIDE OF to VESTIBULE DRIP EDGE CEILING ` 11' - 2 3/41' WOOD CLAD STEEL TUBE BEYOND FSC WOOD BLOCKING 61/2"— INSULATION TO CURTAIN WALL 8 MITORED CORNER ' FRT WOOD CLADDING ON THREE SIDES SEALANT FRT TONGUE&GROOVE CLG HSS 5X5X.5 i n VESTIBULE ROOF SECTION CURTAIN WALL n VESTIBULE ROOF DETAIL @ EXTERIOR n VESTIBULE COLUMN, TYP. 1 1/2' = 1'-01, FRT TONGUE&GROOVE CLG 8" 11 3/4" STEEL TUBE WITH WOOD CLADDING, WOOD CLAD STEEL WELDED TO EXISTING TUBE STEEL BY LL SUPPORT STOREFRONT BY GC BREAK METAL COVERED STEEL BY LL CURTAIN WALL 8Y LL BREAK METAL @CURTAIN WALL BY LL WOOD CLADDING TO CONTINUE OVER BREAK METAL VESTIBULE COLUMN, / CLADDING PARTIALLY 1 COVERS STOREFRONT,TYP. 1 X 12 FRT WOOD FASCIA BOARD TO METAL CHANNEL FRAMING Q WRAP ALL EDGES OF VESTIBULE ROOF 0 , CURTAIN WALL BY GC WHITE EPDM ROOFING I I A402 1 1 B.O. CURTAIN WALL 1 12' - 0" - 1 s 02 i Entry Level I' 0' - 01, _VESTIBULE CEILING FRAMING BREAK METAL VESTIBULE LATITUDINAL SECTION n VESTIBULE INTERIOR WEST KV L02.09.07 ISSUEFORBID No By Date Description L.L. Bean WOOD CLAD STEEL SUPPORT WOOD CLAD WOOD CLADDING STEEL SUPPORT PARTIALLY COVERS TOP MULLIONS UNDERSIDE OF ' VESTIBULE d CEILING ALUMINUM STOREFRONT 11' -2 3/4" STOREFRONT BY GC STOREFRONT BY GC BREAK METAL VESTIBULE COLUMN, CLADDING PARTIALLY / The Shops at Evergreen Walk COVERS STOREFRONT,TYP. ,' `� / ,' `, 75 Tamarack Ave Building C, Suite 75 South Windsor, CT 06074 VESTIBULE DETAILS ' Checked B Checker Job No: 06125.00 Entry Levu _ Entry Level ® — _ Entry Level 0' - 0" 0' - 0" 0f _ 01, A402 102 101 103 104 n VESTIBULE INTERIOR SOUTH n VESTIBULE INTERIOR EAST n VESTIBULE INTERIOR NORTH C:\ReviNS Wind sor\125-base_local-sh(Recovery).nrt 1/2 2/9/2007 12:45:21 PM i STOREFRONT NOTES N 1. U.N.O.ALL STORE FRONT FRAMING TO BE VISTAWALL FG-3000 THERMAL MULTIPLANE SERIES-FRONT SET. U O 2.ALL EXTERIOR GLAZING TO BE 1"THERMAL GLAZING. ALL INTERIOR GLAZING TO BE 1/411. m i 3. USE LOW'E'GLAZING AT ALL EXTERIOR STORE FRONTS 4. U.N.O.USE OPTIONAL SILL @ SIDELITE BASE,VISTAWALL#H0914 0 m 5. USE VISTWALL#V0911 90 DEGERE OSC AT OUT SIDE CORNERS. ! r, i o 0 6.ALL GLASS TO BE TEMPERED WHERE REQUIRED BY CODE, INCLUDING BUT NOT LIMITED TO GLASS WITHIN N THE SWING OF DOOR rn T 7.ALL ENTRY DOORS TO BE RUGGED MS-375 ENTRY DOORS WITH CONCEALED CLOSERS U 8. ONE LEAF EACH PAIR TO BE POWER ASSISTED WITH A PUSH BOTTON DOOR OPERATOR.SEE PROJECT MANUAL FOR OPERATOR&DEVICE PLANS FOR BOLLARD MOUNTED PUSH BUTTON LOCATIONS. 9.ALL METAL FRAMING MEMBERS TO MATCH EXISTING CURTAIN WALL MATERIAL&FINISH: KAWNEER ANTIQUE BRONZE. j 10. INSTALLER TO FIELD VERIFY ALL DIMENSIONS 11.GC TO SUBMIT SHOP DRAWINGS FOR ARHITECT'S REVIEW PRIOR TO FABRICATION&INSTALLATION. CURTAIN WALL NOTES wa o 1 Q LANDLORD TO FURNISH CURTAIN WALL. 1 .aJ ro �j � N o ry u K � u N O N N N ' i �N�❑1 W Y J � .O W� O I I I I I I I I - - - - - -Le 1 I 1 3 I A404 I i I I I 1 I 1 1 1 I I I 1 I I I II ® see - - — �-) I �1 - - - - - - - - - - - - - - 1 1 � I II 1 1 i I 1 1 i ( A402 I i 11 I I I I 1 e I I I 5 I I A404 1 1 1 1' 01/2„ FASCIA BOARD: FRT ROUGH-SAWN KNOTTY CEDAR WITH ONE COAT CABOT CLEAR SOLUTION 9300, ( I I I COLOR:17700"NATURAL" ��� eeee BRAKE METAL BY LL . . e e e e eeeeeeeeee eeee eeee I I I I CURTAIN WALL BY LL I 1 I I � FRT FSC PLYWOOD I B.O. CURTAIN WALL C CHANNEL o ---- - UNDERSIDE OF VESTIBULE _ l<v___ Date o7 _ DsllEFoR FORBID No By Date Description CEILING t:==3 11' -2 3/4" ® L.L. Bean I I FRT FSC PLYWOOD FRT T&G CEILING:KNOTTY CEDAR WITH ONE COAT CABOT HSS 5X5X.5 CLEAR SOLUTION 9300,COLOR: 17700"NATURAL" ,•`", FfiR p� FSC FRT BLOCKING WOOD CLAD J �I C CHANNEL BEYOND � J FRT WOOD CLADDING ON BEAM&COLUMN: KNOTTY CEDAR WITH ONE COAT CABOT ALUMINUM VESTIBULE CLEAR SOLUTION 9300, COLOR: 17700"NATURAL" t STOREFRONT i n VESTIBULE ROOF CONDITION @ INTERIOR TYP. 1 1/2" = 1'-01, c= CURTAIN WALL BEYOND 4 I I I 1 I 1 ! The Shops at Evergreen Walk 1 1 Level 75 Tamarack Ave EntryBuilding C, Suite 75 0' - 0" n South Windsor, CT 06074 3/4"FRT FSC PLYWOOD VESTIBULE DETAILS 1 VESTIBULE STOREFRONT I i 1 I I 1 1 A 03 1 Checked By: Checker i I ( Job No: 06125.00 A403 I r1 PORCH SECTION @ CURTAIN WALL -0" n /Vestibule 0Longitudinal Section - 11 C:1RevitlS W i ndsor1125-base_local-sh(Recovery).nd 2/9/200712:45:28 PM i ----- -- _ . -- ----- ------------ - -- - -- - - - -.._ ------ ------- - ----------- .._ - - _. _ .-- ----- - - _.. ------- ---- - - - tJ C N m I N U O N N Q T N E OI N m O N L Ol OT, I O a C ; r y V1 Cy u I � �o y E 0 o ❑ u � 0 �O v� aa �, caaw I .9 STEEL BASE LET INTO POST AND SECURED WITH THROUGH BOLTS RANDOM WIDTH STANDING SEAM METAL ROOFING PANELS METAL FLASHING APPROPRIATE TO ADJACENT EXTERIOR CLADDING 3 x 12 DOUG FIR JOIST,TYP. STEEL BASE FABRICATION ANCHORED TO CONCRETE FOOTING BELOW STANDING SEAM METAL ROOF PIGEON SPIKES SIDEWALK METAL FLASHING AS APPROPRIATE TO ADJACENT EXTERIOR CLADDING THROUGH WALL BEAM BEYOND STEEL JOIST BRACKETS BOLTED TO JOISTS&WELDED TO BEAM — — — 3/4"TONGUE&GROOVE DECKING 3 X 14 PSL LEDGER BOARD BY TENANT ATTACHED TO THROUGH WALLLVBEAMS BY LL _ _ Entry Level ®1 DOUG FIR PURLINS I 0' - 01, WOOD BLOCKING � I � I 3 X 12 DOUG FIR JOIST BY TENANT,TYP. / � I II � I I � u u GALVANIZED METAL GUTTER -- GALANIZED METAL GUTTER CLIP I w12 x zz Bottom of Steel n I I I I I I � I STEEL BRACING BRACKETS BOLTED TO POST&WELDED TO BEAM I I I HEAD OF WINDOW I i I W14 X STEEL SUPPORT, BY LL I 8 x 8 DOUG FIR POST Porch Connection Detail at Wall Top of Porch Column Porch Column Base Porch Connection Detail at Curtain Wall 3 1 1/2" = 1'-0" 7 1 1/2" = 1'-0" 5 1 1/2" = 1'-0° 4 1 1/2" = 1'-0" KV 02.09.07 ISSUE FOR BID W14 STEEL MEMBER ATTACHED AT BOTH No By Date Description ENDS TO NEW STEEL ON COLUMN LINES C WOLMANIZED PARALLAM(PSL) O W14 STEEL MEMBER SPANNING BETWEEN D C.7 T TO SUPPORT ATTACHED TO THROUGH WALL PORCH �M ROOF. ON RIGHT AND E W14 ON T LEFT E B L.L. Bean COLUMNS 1 &.9 THROUGH WALL BEAMS,TYP. FOR 7 WOLMANIZED PARALLAM(PSL)ATTACHED TO WOLMANIZED PARALLAM(PSL) I 3 W14 STEEL MEMBER WOLMANIZED PARALLAM(PSL)ATTACHED TO THROUGH WALL BEAMS BY TENANT ATTACHED TO THROUGH WALL BEAM y SPANNING BETWEEN THROUGH WALL BEAMS c ON LEFT AND W14 ON THE RIGHT (II) A403 COLUMNS 1 &.9 1 — — — ------- --- — — — — —e — — — — — — — r — — — — — — — ----------- — — — — — ' � I ' I I The Shops at Evergreen Walk 75 Tamarack Ave ' X X X Building C, Suite 75 South Windsor, CT 06074 PORCH DETAILS L4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 6 Checked By: Checker 16' __0'-0" 12'-0" Job No: 06125.00 20'-0" 12 -0 20'- i i A404 1 Porch Framing Plan 1/4" = 1'-01, _ --ocaksh(Recovery)xvt -_- . base - C:1RevitlSWindsor1125 _l 2/9/200712:45:37 PM d C m to U N Q N I a m E rn `m m 0 N .0 LJ1 .0 d O U i i w P. n h Cn H y p N O C U y N p7 O d O C o V o p Pi nw C. w i A 1 I I 5"GLOSS LL BEAN GREEN ALUMINUM RETURN 5"GLOSS LL BEAN GREEN ALUMINUM RETURN I 1"BLACK TRIM CAP V BLACK TRIM CAP I I FLEX FACE, PAINTED LL BEAN GREEN, PANTONE 343 I I LED LIGHTS OPERATED VIA TIMECLOCK PLEX FACE, PAINTED LL BEAN GREEN, PANTONE 343 I LED LIGHTS OPERATED VIA TIMECLOCK i ALUMINUM COVER TO BE USED OVER ANY EXPOSED WIRES TO LEDs. ALL TRANSFORMERS IN LETTERS TO BE HARD WIRED TO JUNCTION BOX. 7"X 7"RACEWAY PAINTED TO MATCH LL BEAN GLOSS GREEN, j POWER SUPPLY PANTONE 343, INCLUDING ALL FASTENERS POWER SUPPLY i - - I I - UL LISTED EXTERIOR SET DISCONNECT SWITCH GC TO PROVIDE POWER - - - STAINLESS STEEL MOUNTING HARDWARE, BLOCKING TO BE USED IF NEEDED. SILICONE SEALANT AT ALL WALL PENETRATIONS. STRUCTURAL STEEL BY LANDLORD EXTERIOR BOARD&BATTEN WALL BY LANDLORD CURTAIN WALL BY LANDLORD EXTERIOR SIGNAGE NOTES I 1. STRUCTURAL STEEL TO SUPPORT 600 LBS DESIGN LOAD. ' i i 2. STRUCTURAL STEEL BY LANDLORD. I i I 3. SIGNAGE BY TENANT, TO COORDINATE / SCHEDULE INSTALLATION WITH LL FIELD TC. 4. SEE MANUFACTURER'S DRAWINGS FOR ACTUAL COMPONENTS AND FINAL COLOR SELECTIONS. 5. ALL SIGNAGE TO BE FILED UNDER SEPARATE PERMIT BY SIGNAGE VENDOR. KV_jEAST FACADE SIGN SECTION By os.os.o7 ISSUE FOR BID - - -_ n n SOUTH FACADE SIGNAGE SECTION No By Date Description L.L. Bean 1 ;1 3 ' 21'-6"TBD BY VENDOR D ^ A405 ^ n l� C L C q A405 21'-6"TBD BY VENDOR 6,_g„ i I 6,-3" . I � I I STRUCTURE BY LANDLORD c0 ;., The Shops at Evergreen Walk 75 Tamarack Ave B Building C, Suite 75 South Windsor, CTT 06074 J EXTERIOR SIGNAGE O O DETAILS _ Checked By: Checker Job No: 06125.00 LM A40b r;-� EAST FACADE SIGNAGE ELEVATION n SOUTH FACADE SIGNAGE ELEVATION C:1Revii\125-base_IocalJen.rvt 2/9/20071:51:49 PM U I C N � I l0 , U N N E 21 N rn O N of m T a 0 i U WALL SURFACE SEE A601 FOR WALL TYPE c o , 0 PAINT ABOVE TOP TRIM o c 0 u PT 02 y 6 u ti 'Z N A501 RANDOM SQUARE CUT TOPS OF BOARDS 7 _� y e a U M In Vi O 'y( P: R 1X3 SOLID WOOD STRAPPING MAX.BOARD HEIGHT 16'-4� w a w 5 WD 09 PT 01 - MIN. BOARD HEIGHT 15'-4" I cV R RANDOM WIDTH WD BOARDS FINISH NAILED TO STRAPPING FBO, SHOP MTL STANDARD T-0"AFF _ FINISHED INSTALLED BY G.0 8'-0"STANDARD U.N.O WD O1 PT 04 (V m WD 01 PT 04 _ WD 08 PT 01 O v , z a a - 1 1X3 SOLID WD STRAPPING SECURED TO 803 PLYWOOD — -9 WD 09 PT 01 VARIED SEAMS BETWEEN DIFFERENT HIEGHT BARN O - — 3/4" BOARD LOCATE SEAMS ON m STRAPPING z N co co b W N MTL STANDARD(ST-9)(MT- w LOCATE BARNBOARD JOINTS AT STRAPPING TYP. 01)PRE-DRILL FOR EXPOSED NAILS z i` ATTACHMENT TO OXIDIZED FINISH N HORIZONTAL STRAPPING 1/8"NAIL HEAD w o z Z N J U MTL STANDARD(ST-DEEP), PRE-DRILL FOR BOTTOM OF BARN BOARD ATTACHMENT TO HORIZONTAL STRAPPING AT 31Y2"AFF TYP. o SPACING AS NOTED 1X3 SOLID WD STRAPPING ¢ TYP STANDARD 8'-0", OWNER TO PROVIDE 11' SECURED TO PLYWOOD STANDARDS AS NOTED ON ELEVATIONS FOR 1 ATTACHMENT OF FEATURE SHELF BRACKETS ' WD 09 PT 01 WD 08 PT 01 ( N oo SHELF S.B.O � MT 01 1X3 SOLID WD STRAPPING 1X6 SOLID WD BASE j RANDOM WIDTH FINISH NAILED TO STRAPPING WD 09 PT 01 WD 09 PT 01 A5o1 0 WD 01 I ' _' •••• .. _ _.• •• __ _ - BARN BOARD VARYING HEIGHTS N D 08 PT 01 _— AND WIDTHS FINISH NAIL TO N STRAPPING i 1 A501 m 1X6 SOLID WD BASE M 1X6 SOLID WD BASE 10 --— -- — I WD 09 PT 01 } WD 09 PT 01 Li A803 WD 01 PT 04 " — — ' — J.1 m m n TYP. 2'-0" TYP. MTL STANDARD(ST-DEEP) MT 01 n BARN BOARD WALL BASE SECTION n BARN BOARD PLAN SECTION LOWER 6 BARN BOARD WALL SECTION BARN BOARD PERIMETER LEVATION 3" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" 5 1/2" = 1'-0" 2 , A501 1 LAYER 5/8"'TYPE X"GWB 2'-0" 2'-0" GWB PT 02 PT 02 15'-6 SLIDING BARN DOOR TRACK SECURED TO HEADER @ 16"O.C. j -- TRACK FOR BARN DOOR 2 1/2 I 1l4"X2"CROWN INDUSTRIAL FLAT SLIDING WALL BY G.C. TRACK.TRACK LOCATIONS AS NOTED IN ELEVATIONS 2X6 SOLID WD TRIM SECURED THROUGH 2x6 SOLID WOOD HEADER TO PLYWOOD AND BLOCKING n CARRY WEIGHT OF SLIDING AND MTL STUDS BARN DOORS,SECURE THROUGH PLYWOOD ! Kv 02.09.07 ISSUE FOR BID WD 09 PT 01 WD 09 PT 01 No By Date -- Description _ 1X FRT WD BLOCKING L.L. Bean 1X3 SOLID WD BATTEN WD 08 PT 01 �� cn WD 09 PT 01 1x3 SOLID WOOD BATTEN TO CONCEAL PLYWOOD JOINTS 4 � WD 09 PT 01 ' - 1X4 SOLD WO TRIM PLYWOOD SEAM CONCEALED WD 09 PT 01 BEHIND WD TRIM 1X4 SOLID WOOD TRIM WD 09 PT 01 a` r PLYWOOD SEAM CONCEALED - ' BEHIND WD TRIMco 4'X10'PLYWOOD SEAM CONCEALED I BEHIND WD BATTEN WD BATTEN OR STANDARD BEYOND DOUBLE METAL STUD FRAMING DOUBLE METAL STUD FRAMING 1X FRT WD STRAPPING 2'-0"O.C. z WD O$ PT 01 32"O.C. IF MTL.STUD SPACING 32"O.C. IF MTL. STUD SPACING FROM BASE IS 16"OC. IS 16"OC. w Q The Shops at Evergreen Walk 1x FRT WD STRAPPING = MTL STANDARD(ST-REG)SURFACE 75 Tamarack Ave t- APPLIED TO WOOD BATTEN S.B.O. Building C, Suite 75 iX FRT WD STRAPPING D 08 PT O1 INSTALLED BY GC MT 01 South Windsor, CT 06074 wD os PT 01 WD 08 PT 01 MILLWORK DETAILS 1X3 SOLID WOOD BATTEN T-0"O.C. 3 p CONCEAL PLYWOOD JOINTS 4'-0"O.C. A501 S 1x3"SOLID WOOD BATTEN 2'-0"O.C. WD 09 PT 01 n CONCEAL PLYWOOD JOINTS 4'-0"O.C. o WD 09 PT 01 MTL STANDARD SURFACE APPLIED TO i 1X6 SOLID WD BASE so TWOOD BATTEN S.B.O. INSTALLED BY 1X6 WD BASE Checked By: Checker 2'-0"TYP. 2'-0"TYP. 2'-0"TYP. 2'-0"TYP. GC 2'-0"O.C. WD 09 PT 01 -- --i - -- MT 01 __� WD 09 PT 01 Job No: 06125.00 4'_0„ Entry Level � CL 0' - 0" BASIC PERIMETER PLAN SECTION UPPER BASIC PERIMETER PLAN SECTION LOWER BASIC PERIMETER WALL SECTION IN Basic Perimeter T . A501 n Yp U 1 1/2" = 1'-0" U 1 1I2" = 1'-0" 1 112 - 1 0If 11 C:1RevitlSWindsor1125 base_local-sh(Recovery).rvt _ .-_. _ ........ _. . ... .- . - _ ._ __ -- - ... __ _ . _ - -- _ __. . -- ...__. - 2/9/2007 1:46:46 PM I m U N N Q N E m N m O N m a a U 1X8 SOLID WD CAP WD 06 PT 06 1X3 SOLID WOOD TRIM WD 09 PT 01 1X8 SOLID WD CAP u WD O6 PT 06 o Z4 o 1X3 SOLID WD TRIM SOLID WD.TRIM WD 09 PT 01 v z 1/4" 6" 3143/4" u `� v w e tlwu waw 1X FRT WD STRAPPING 8 utl o" X ro M 1 FRT PLYWD A502 BEADBOARD 1X3 BATTEN WD 12 08 PT 01 A502 1X8 SOLID WD CAP 3/4"X21/2"SOLID WD TRIM 2'-o"TYP. WD 06 PT 06 STUD CAVITY - 1"X4"SOLID WD SLAT 1X8 SOLID WD CAP WD 09 PT 01 WD 06 PT 06 12'-7" 3/4. 1/2" 3/4" 1X3 SOLID WOOD TRIM ZXOFROTCWD STRAPPING 1X3 SOLID WOOD TRIM 3 1/2" 3/4" WD OS PT 01 3/4"X3 1/2"WD BATTEN WD 09 PT 01 WD 09 PT 01 ; 1/2" 3I4 „ WD 09 PT 01 -WD OS PT 01 WD 08 PT 01 11 1'W"WD SLAT n CASH WRAP WALL END DETAIL 1x3 SOLID WOOD BATTEN TO 14 A5o2 WD 06 PT 06 1X3 SOLID WOOD TRIM WD 09 PT 01 U 3" = 1'-O" 1"X4"WD SLAT CONCEAL PLYWOOD JOINTS WD 09 PT 01 1X FRT WD STRAPPING WD 06 PT 06 I TOP SLAT 8'-11 1/2" 2'-0"O.C.FROM BASE SIM 9'-0" 13 ® 113 3 SIM A502 - - - D 08 PT 01 A502 13 1"X4"WD SLAT 777 — TYPICAL WALL(CORNER EDGE CONDITION 1X FRT WD STRAPPING A502 BATTENS TO LOCATED AT ALL WALL AND WD 06 PT 06 2'-0"O.C. FROM BASE 1x3 SOLID WOOD BATTEN TO 1x3 SOLID WOOD BATTEN TO CORNER CONDITIONS BATTEN TO BE EQUAL o I SPACING AT END OF ALL WALL CORNER OR CONCEAL PLYWOOD JOINTS CONCEAL PLYWOOD JOINTS EDGE CONDITIONS.REMAINING BATTENS TO WD 09 PT 01 WD 09 PT 01 BE 2'-0"O.C. EQ. 2'-0"TYP. EQ. ; I FRT WD STRAPPING WD 09 LINE OF PLATFORM a 1"x4"WD SLAT SEE ELEVATIONS TT 1"x4"WD SLAT WD 08 PT 01 FOR LOCATIONS WD 06 PT 06 WD 06 PT 06 I 1"x4"WD SLAT 1X3 SOLID WD BATTEN 1X6 WD BASE WD 06 PT 06 -. ... ...... . .... __ ffi WD FINISH FLOOR 09 PT 01 N WD 09 PT 01 1X6 WD BASE 1X6 WD BASE FINISH FLOOR N V%4"SOLID WD SLAT WD 09 PT 01 WD 09 PT 01 n 1X6 WD BASE WD 06 PT 06 WD 09 PT 01 V-011 01 loom n CASHWRAP AND BIKESHOP WALL PLAN SECTION n BIKE SHOP PERIMETER SECTION - 12'-7" n BIKE SHOP PERIMETER SECTION - 9'-0" n BIKESHOP PERIMETER - 12'-7" BIKE SHOP PERIMETER - 9'-0" 1 1/2 — 1 0 n n CASHWRAP WALL SECTION O CASHWRAP PERIMETER WALL 1 1/2" = 1'-0" \J 1l2" = 1'-0" U 1/2" = 1'-0" U 1 1/2" = 1'-0" 1!2" = 1'-0" i GWB PT 02 i 2 GWB ASoz PT 02 BLOCKING SOLID WD UPRIGHT SECURED TO PLYWOOD UPRIGHT TO ARRIVE PRE-MARKED FOR - INSTALLATION S.B.O.SHOP FINISHED BLOCKING 4'-0"TYP. 4'-0"TYP. INSTALLED BY GC WD O8 PT 02 WD 06 PT 04 3" 3"X3/4"SOLID WD TRIM CUT TO GO BETWEEN 3"UPRIGHTS TO CONCEAL GWB AND PLYWOOD SEAM WD 08 PT 02 .,,. _..-.�......,>:,,.,.�rcxr.;�:.F�%- -.�•... n.•..�- WD 09 PT 02 N_ SEAM OF GWB AND PLYWOOD 15'-6 1/4" �c - - - - - - - - - - - - - - - -- — o� — - _ D 09 PT 02 ! - - IP/ _0_2.09.07 ISSUE FOR BID - - - - - - - - No By _ Date Description L.L. Bean. r ; , 3 A502 n OUTSIDE CORNER DETAIL INSIDE CORNER DETAIL N 3�� = 1'-0" r 5 3�� = 1'-0" � N ' i1qN 3"X3"WD SLATS SCREW ATTACHED TO VERTICAL STRAPPING ROUTED EDGE ' ON TOP,CUT EDGES TO BE LEFT 0 UNFINISHED FBO SHOP FINISHED r 3"X3"SOLID WD UPRIGHT SHOP FINSIHED INSTALLED BY GC a'-a"TYP. WD 06 PT 04 WD 06 PT 04 II The Shops at Evergreen Walk 3"X3" WD SLATS SHOP FINISHED S.B.O. LJ SCREW-ATTACHED TO VERTICAL D 09 PT 02 75 Tamarack Ave g WD 06 STRAPPINGIPT 04 D BY GC - Building C, Suite 75 0 South Windsor, CT 06074 CONTINUOUS ROUTE AT TOP EDGE Z TO ACCOMODATE ACCESSORY 3'X3'SOLID WD UPRIGHTS I O MILLWORK DETAILS HARDWARE.CUT EDGES TO BE LEFT UNFINISHED 3"X3"SOLID WD SLAT SHOP FINISHED a ` - SHIM ROUTE AT ATTACHMENT LINE OF ROUTE WD 06 PT 04 LOCATIONS AND BOLT TO UPRIGHT, o FINISH HARDWARE S.B.O INSTALLED BY GC SHIMS AND BOLTS S.B.O. 3"X3"SOLID WD SLATS ROUTED EDGE ON TOP zt 3"X3"UPRIGHTS SHOP FINISHED WD 06 Checked By: Checker SECURED TO PLYWOOD UPRIGHTS TO j FINISH FLOOR h ARRIVE ONSITE PRE-MARKED FOR Job No: 06125.00 INSTALLATION d FINISH FLOOR 0'-0 WD 06 PT 04 F � PARTITION AS SCHEDULED A502 4 FOOTWEAR WALL SLAT DETAIL FOOTWEAR FEATURE WALL PLAN SECTION FOOTWEAR FEATURE WALL SECTION 3 0 1 1/2" = 1'-0" n �OOTW 0 R WALL ELEVATION 6ReviflSWindsor\125-base local-shRe v -_--._._ _._ .-- --- ._ .._. _.___.__.._._._. --__---- ----... _ _ __- _ _---- -_.__...... . .__ .__ _ - _. ... ..---. .-.-.....___ _._ _ .. ._ _- _ _ ._ - -- 2/9/2007 12:46:27 PM U C N N 4 A503 o N Q U1 I a E OJ UNDERSIDE OF j m _ CLERESTORY N 36' - 11 1/2" a 0 U 6 A503 8"D FRT PEELED LOG U STANDARD wP — ` AIRCRAFT CABLE n SUAGELOCK A U. o o -0 :? �p N �^ N it THIMBLE S � v 1„ TURNBUCKLErn y r 2pu° crv � p 1"X4"WD SLATS FINISH E o a w NAIL VERTICAL WOOD SECURED TO LOG V r PCI P.o STRAPPING INSTALLED WITH THRU-BOLTED AND FINISHED BY GC EYELETS BY GC RANDOM LIVE EDGES WD 06 PT 06 VERTICAL 1 112"X21/Z' WD STRAPPING BOLTED TO PEELED LOGS WITH STL WASHERS TO ADJUST PLUMB FBO \ INSTALLED AND FINISHED BY GC fil - - - - - - - - - - - - - - - - - - - - - - - - - - - WD 06 PT 06 - - 41 SLAT WALL DETAIL 3" = 1'-0" CABLE CONNECTION DETAIL 8'D FRT PEELED LOG _ I — — _MAX PEELED LOG HEIGHT 20'-o° 6" — 1'-O" PEELED LOGS VARIED HEIGHTS TOP OF POLE TO 20'0 MAX TO BE 16'-0"MIN �- 1/2"STEEL PLATE WELDED TO BASE&LET MAX FOR CABLE CONNECTION 18'-0' INTO PEELED LOG ORIENT PERPENDICULAR ALL CABLE CONNECTIONS TO BE TO FACE OF"WALL" BETWEEN 14'-7"AFF AND 18'-0"AFF MIN.3 CABLES PER POLE VARYING MIN 2 THRU BOLT PER BASE HEIGHTS AND SIDES OF THE POLE - - - - - - PLATE IN PEELED LOG - - - - - - - - - - - MIN?r-F:IFDLni0" HEIGHTI6' 1 SIM HILTI HY150 STAGGER ADHESIVE 6 - - ANCHORS 1/2"D MIN. SPACED 12" A503} O.C. STAGGEREDW/31/2"MIN MIN FOR CABLE CONNECTION 14'-7" IMBONDMENT INTO CONCRETE UNDERSIDE OF - - - - - - - - - -- s �+ - -yµ- FLOOR 1 1 CLERESTORY - - - - - — 8"DPEELEDLOGS LINE OF STEEL PLATE CONTINUING , 36' - 11 1/2" , FOR FEATURE WALL ASSEMBLY — — _ _ — _ _ — — — _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _MAX FOR VARYING SLATS 13'-0" p, c ' d (.L;• .:. a I ;. ,: 1"X4"DECORATIVE WD SLATS SEE Itt - - - - - - - - - - - - - - - - - - - - T - i A504 FOR REPRESENTATIONAL -- ELEVATION V-0"SQUARE BASE PLATE ON STAND ALONE POLES AT CASHWRAP - _ _ _ _ _ _ _ POST DETAIL (2) _ __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ - - 1 - - - - - - - - - - - 1 - - f — 1"X4"WD SLATS MIN 3 CABLES PER LOG SPACED 60 DEGREES TO EACHOTHER ALL GOING IN 8"FRT PEELED LOG DIFFERENT DIRECTIONS,CABLES MUST BE AT VARYING ANGLES IH 2 THRU BOLTS PER STEEL h PLATE IN PEELED LOG BRACE PEELED LOGS TO STRUCTURE I<v 02_ -- ABOVE USING STANDARD AIRCRAFT os.o7 ISSUE FOR BID CABLE No By Date Description 3/8"STEEL BASE PLATE d LENGTHS INDICATED ON A504 L.L. Bean 12"WIDE(12"X12"ON STAND ALONE POSTS AT CASHWRAP) i OSIM 2 — — — — _ _ _ BASE OF BOTTOM SLAT T-0" HILTI HY150 STAGGER ADHESIVE 5 8"D FRT PEELED LOG FBO INSTALLED ANCHORS 1/2"D MIN.SPACED 12"O.C. A5D3 AND FINISHED BY GC A503 — STAGGERED W/31/2"MIN A EMBEDMENT INTO CONCRETE FLOOR �. .ral.A a L= a •:I 1. bl I:+ n GEAR WALL ELEVATION ` n POST DETAIL U 3" = 1'-01' " POLE DIMENSIONS VARY PER GEAR WALL SEE SHEET A1504 FOR DIMENSIONS zo HILTI HY150 STAGGER ADHESIVE -- 1'-0"O.C. ANCHORS 1/2"D MIN.SPACED 12"O.C. 1"X4"WD SLATS FINISH NAILED TO STAGGERED W/3 1/2"MIN IMBONDMENT INTO CONCRETE FLOOR w VERTICAL WOOD STRAPPING FBO INSTALLED AN FINISHED BY GC •® 3/8"CONTINUOUS STEEL BASE PLATE u WD 06 PT 06 The Shops at Evergreen Walk G BASE PLATE DETAIL 75 Tamarack Ave 1/2" = 1'-0" Building C, Suite 75 South Windsor, CT 06074 A 03 ATTACH CABLE TO TOP CORD OF JOISTS VERTICAL WD STRAPPING BOLTED MILLWORK DETAILS - WHENEVER POSSIBLE TO PEELED LOG WITH STL BASE PLAT ASSEMBLY TO CONSIST OF 3/8"STL GEAR WALLS WASHERS TO ADJUST PLUMB FBO BOTTOM PLATE WITH 1/2"THICK VERTICAL PLATE INSTALLED BY GC WELDED TO BOTTOM AND LET INTO BOTTOM OF LOG SUAGE LOCK WD 06 PT 06 DIMENSIONS VARY PER GEAR WALL <o -- 8"D FRT PEELED LOG FBO INSTALLED AND Checked By: Checker FINISHED BY GC ;o o ( Job No: 06125.00 1 _ — --- VERTICAL WD STRAPPING BOLTED TO STANDARAIRCRAFT CABLE ABLE o ' A503 PEELED LOG WITH STL WASHERS TO ADJUST PLUMB FBO INSTALLED BY GC WD 06 [ A503 PT 06 3 1"X4"WD SLATS FINISH NAILED TO VERTICAL A503 WOOD STRAPPING FBO INSTALLED AN FINISHED BY GC CABLE TO JOIST ATTACHMENT GEAR WALL SECTION 1 GEAR WALL ENLARGED PLAN —� WD 06 PT 06 6" = 1'-01, ` 1/211 = 1'-01, 1/2" = 1'-0" C.\Revit\SWindsor\125-base-local-sh(Recovery).rvt 2/9/200712:46:40 PM U y m i0 •U O Q N m E rn `m m 0 N ADDITIONAL VERTICAL WD STRAPPING BOLTED TO PEELED LOG WITH STL WASHERS TO i ADJUST PLUMB FBO INSTALLED ° U BY GC 8"D FRT PEELED LOG _ V ti rn d F p � C y u m m � U 2 w 6y , o .° w o c Cra PaF� u. 5 GEAR WALL CORNER DETAIL TYP. 1 1/2" = 1'-0" i 4 A802 2 A8 0 5 SIM ,Z 0P' A504 6 5 \ 90. 118° �0�, 3- A ' 5. 3^ SEP� P SIM 12' 2 $ASF P 3 1 ' A603 SATE mil` Z ma`s, � � r 9T 3• 123° 2e \ A I SIM A603 i I n GEAR WALL ELEVATION (2) PLAN n GEAR WALL ELEVATION (1) PLAN 3/8" = 1'-0" 3/8" = 1'-0" i KV 02.09.07_I ISSUE FORBID_ No By Date Description L.L. Bean - - — ------------ Hi I III n '! C Ij The Shops at Evergreen Walk 11 Hill 75 Tamarack Ave Building C, Suite 75 —_ South Windsor, CT 06074 i GEAR WALL ELEVATIONS, PLANS AND DETAILS Checked By: Checker Job No: 06125.00 n GEAR WALL ELEVATION (2) n GEAR WALL ELEVATION (1) 3/8" = 1'-0" i NOTE: SEE A503 FOR TYPICAL DETAILA504 INFORMATION C:\Revit\S Windsor1125-base_local-sh(Recovery).rvt 2/9/2007 12:46:48 PM .....-------------.._._ --- - -. .._ _ c I WOOD POST FOR KAYAK DISPLAY TOWER, SEE PLAN o 5#8 0 BOLTS IN LONG VERTICAL L4 X 4 X 1#4" EA SIDE OF POST a SLOTS IN POST & BOTH ANGLES, FINGER TIGHT WITH SPOILED E THREADS TYP m 1/4' N O 0 i O i (2)3 X 10 FRT WOOD 1"X 3"STEEL 3 X 8 X 12 WOOD METAL BLOCKING TUBES @ 2'-0"O.C. @ 2'-0"O.C.VERTICALLY. VERTICALLY 3 X 8 X 24 @ SPLICES. 5/8"BLACK HEX HEAD BOLT WITH WASHER AND DOUBLE NUT. CUT SECURE DISPLAY RACK TO END OF BOLT FLUSH TO j STRUCTURAL STEEL, SEE S/A505 OUTSIDE F - NUT. p AL JL � N o � o O u C u v 0 o' A 1"X 3"X 12"STEEL TUBES WELDED TO MAIN TUBE Asoe 1/2"+/-HOLES FOR 1/2"EYE BOLT,TYP. rn o v u °pp v' d� � a ENLARGED PLAN DETAIL �t oa u w a u EXISTING BAR JOISTS VIF 27-9 V.I.F. A.F.F. 7 v ° XTOP BRACING DETAIL UNDERSIDE OF 3 = 1 -0 STRUCTURE LJ LJ 3 x 10s,BY OTHERS,TOP PANEL NEEDS TO BE CUT AROUND THEM TOP PANEL WITH ROUTED L J GROOVE 1/2" YP. 6 1/2"CLEAT ATTACHED TO METAL TUBE, BY OTHERS. OPENINGS ON SIDES OF BOX L J _ TO FIT OVER METAL TUBE. 7d SECURE TOPS OF DISPLAY RACK TO STRUCTURAL STEEL BEAM,TYP. I 3 X 8 BLOCKING BEYOND, 8 Asos J o BY OTHERS L N O TYP. L J 0'-0"A.F.F. 4 FINISH FLOOR 27'-9" V.I.F. A.F.F. UNDERSIDE OF I 3 X S X 12 WOOD BLOCKING BEYOND 2 5 STRUCTURE @ z'-0"O.C. L J 6 ROPE BOX SECTION L J 1 X 3 STEEL TUBES @ 2'-0"O.C. 1"X 3"X 12"STEEL TUBES (MAIN TUBES) WELDED TO MAIN METAL TUBE L J 91, 2'-9 39' 9„ 2'-9 3/4" 6. 9„ 2'-9 3/4" 9„ 2'-9 3/4" 9„ 3 X 10 FRT WOOD I NOTE: BOTH SIDES ARE IDENTICAL L J 3 X 8 X 24 @ ALTERNATING SPLICES I LJ — L J 6 1/2"CLEATS WELDED TO MAIN TUBE DOUGLAS FIR 3 X 10 FRT WOOD ON EITHER ROPE COLLECTION BOX SIDE OF BLOCKING 6 Asos LOCKING DOORS ROPE COLLECTION BOX \ Kv oz.as.07 ISSUE FORBID 1 / \ / \ / \ / \ / \ / \ / \ / / No ey Date Descriplian 4"TOE KICK A505 o'-o° A.F.F 0 U " L.L. Bean FINISHED FLOOR \ I n KAYAK DISPLAY RACK SECTION 4 ROPE BOX ELEV U 1/2" = 1'-0" 1/2" = 1'-0" 24"BLOCKING �`•, ' , j ALTERNATING 1 X 3 STEEL TUBE @ 2'-0"O.C., SPLICES,TYP. CENTER ON BLOCKING,TYP. 3 X S WOOD BLOCKING 3 @ 2'-0"O.C.VERTICALLY A505XZnn ROPE COLLECTION gp HOLES FOR 1/2"D.EYE BOLT i 1"X3"STEEL TUBE(MAIN TUBE)WITH WELDED END PLATE WITH EXPOSED q CONTINUOUS WELD 5A505LINE OF ROPE BOX IN FRONT The Shops at Evergreen Walk r-o" a'-o° 75 Tamarack Ave � 9' TAP ! Building C, Suite 75 1"X 3"STEEL TUBES ABOVE South Windsor, CT 06074 STAINLESS STEEL CLEATS @LDED TO MAIN TUBE @ V-6"O.C. MET°TUBE. AC. LIGNWTED OH MILLWORK DETAILS - HOLES&HOLE MID-POINTS. m= LL KAYAK WALL iV N I 4"X 12"X 6"W BLACK STEEL U Checked By: Checker o ANGLE EO EO EO EO EO Job No: 06125.00 0'-0" A.F.F EO 15'-0" FINISHED FLOOR 2'_0" 3 X 8 BLOCKING TYP. T P TYP. 1/2"OPENINGS THROUGH TOP 15'-0" PANEL, SPACED V-0"O.C. A505 Asos/J— i n KAYAK DISPLAY RACK ELEVATIONS & SECTION n ROPE COLLECTION BOX - PLAN VIEW U ... -- - _ - _ . _. __.. . -.._ _ . ._ _ _ _ __ ._ ... -- _-- - --. _ ... ...... . . .. .. ... C.1Revit\SWindsorH25-base—local-sh(Recovery).rvt _ _._.. ._ __ __. _ __ _ _....-_.-"--_.__ _ -_ __.... .. . ....___.._. ._"._. _. ._ ... _ __ _.__ ___.__ _._.. .._ _ _.. . _ . _ _.___ .. ._. _ __._._ . .___.-_-__ _ ..___ _ _ ._ _ _ _.. ..-..__. _.....___ 2/9/2007 12:46:52 PM O C N m U O N Q QI T N E m - m O O N L CA .T p U w P. n U N CC,, N O 7+ N y � � �} N-r-n_ e❑❑ v C [ e v p O .0 GfQ n Pl t~ fr. r ZINC COATED 1/2"EYE BOLT WITH WASHER AND DOUBLE NUT THROUGH 1/2" HOLE IN BRACKET,TYP. 1"X 3"STEEL TUBE BRACKET NYLOCK NUT STRAIGHT ii BRACKET 9/16"THREADED ROD BENT TO SPECIFIED DIMENSIONS. WASHER WELDED TO ROD. PVC FREE VINYL COATING FROM HERE DOWN. NOTES: 1. LOAD CAPACITY SHOULD BE EQUAL TO OR GREATER THAN 40 LBS. 2. QUANTITY: 100 O 3 7/8" 3" O i n ACCESSORY HOOK n MAIN TUBE SECTION DTL U 6" = 1'-0" i MAIN TUBE SETSCREW 1/2" WELD BAR TO U-SHAPED FITTING HOLES, TYP. FOR 3 1"X 3"X 4"(INTERIOR DIMENSIONS) OF U SHAPED ATTACHMENT TO FIT MAIN TUBE ON MAIN TUBES OF KAYAK DISPLAY 1"X 3"METAL TUBE BRACKET 'v WELD BENT STEEL BAR TO EQ EQ U-SHAPED FITTING SETSCREW 3 X 10 1 2" 3" 2" 1�2" 1/8"THICK PVC FREE RUBBER FRT MEMBRANE TO BE ADHESIVE DOUG FIR APPLIED (3) 1/2"HOLES 34'D. BOLTS,TYP. TO TOP THIRD OF BAR SURFACE 1 1/4"D. BENT STEEL BAR N 3X8X24FRT h DOUG FIR BEYOND, CENTERED ON j(?1 SPLICE /4' / �t - KV 02.09.07 ISSUE FORBID n BRACKET PLAN VIEW / No By Date Description U 6�� = 1'-0" 27 METAL BAR ELEVATION 6" = 1'-0" i L.L. Bean SPLICE M CC i f < 1"X 3"X 4"INTERIOR DIMENSIONS OF U-SHAPED FITTING 1/8'THICK PVC FREE 1° RUBBER MEMBRANE SETSCREW TO BE ADHESIVE MAIN TUBE APPLIED TO TOP THIRD OF BAR O 5/8"BOLT SECURING WELD STEEL BAR TO U-SHAPED FITTING SURFACE MAIN TUBE N MAIN TUBE TO 3 X 8 BEYOND 1"X 3"METAL TUBE BRACKET 1-0 = 7/6" 8" 101. N 1/2"HOLES O 1/2" HOLES, TYP. FOR 3 6 4" 1 112" STRAIGHT BRACKET ELEVATION n CRADLE BRACKET -0 n METAL BAR PLAN VIEW — "`� 1 112" = 1'-01, "' 6" = 1'-0" The Shops at Evergreen Walk O75 Tamarack Ave N Building C, Suite 75 South Windsor, CT 06074 s 6 1"X 3"STEEL TUBE(MAIN TUBE) 2a 1"X 3"STEEL TUBE(MAIN TUBE) A508 KAYAK DISPLAY RACK 4„ DETAILS STEEL BAR WELDED TO MAIN TUBE 3/4" i 1"X 3"METAL TUBE BRACKET WELDED TO MAIN TUBE I ❑ _ 4a Checked By: Checker 3a 2b asos MAIN TUBE A506 ASos Job No: 06125.00 SET SCREW 1 1/4" D. BENT STEEL BAR WITH PVC FREE RUBBER MEMBRANE WELD BAR TO U-SHAPED FITTING 2'-7" A506 n STRAIGHT BRACKET CRADLE BRACKET PLAN VIEW METAL BAR „ _ �oL n SPLICE DETAIL j 6 — 1 -0 �J 1 1/2" — 1'-0" U 6" = 1'-0" 3" = 1'-0" _ewtl_SWind. _.. sor1125•base_local-sh(Recovery).rvt 2/9/2007 12:46:55 PM U DASHED LINE DENOTES c SLEEPING BAG STORAGE m UNIT 3/4"X5"WD END PEICE TYP. m WD 06 PT 06 a E TYP METAL OPEN FLANGE rn CLOSET ROD SUPPORT m N WD 08 PT 08 i MT 01 N PINHOLES DRILLED INTO EACH rn v 2X12 VERTICAL STUD 6"O.C. DASHED LINE DENOTES VERTICALLY PINHOLE SIZE TO a SUIT SHELF SUPPORT HEFELE SLEEPING BAG STORAGE UNITS ! U 1X2 WD BLOCKING TO METAL SHELF SUPPORTS ITEM# METAL ROD 1 1/2"D SUPPORT SHELVES TYP 282.38.708 3/4"X4 1/2"SOLID WD SLATS ^kc,-N F: ;*%'t .c:;u. grr e'_, >:rt�.rmr ,_hv-,.r_:,.r,ras _H s: .,_.._.r�., v:..:-_N-z.irv!`.- rsnr. tom. ,:k„r '�-,.:a:arsy., ru,• .-;:�.�•:.:..,.<.+ WD 09 PT 08 i BUTTJOINTED MT 01 i METAL CLOSET ROD BRACKET O.C. GC TO PROVIDE(12) 1"THICKX 8 3/4"X 91/4"SOLID WD MT 01 -_ SHELVES 2xl0 WD BETWEEN STUDS 3/4"X4 1/2"WD SLATS BUTT `� ALL MARKS TO BE SANDED JOINTED U 0 ' WD 06 PT 06 .p •� N 2X4 SOLD WD BLOCKING � I o I I lu rn 0 [ Y o N o / 3l4"X4 1/2"SOLID WD SLATS o o ATTACHED TO FACE OF WD STUDS ° v BUTTJOINTED v a 4 3/4"XS"WD END PEKE TYP. 3 c A WD 06 PT 06 o WD 06 PT 06 5 W n W R. [r ' I I I CV iV I I n SLEEPING BAG - ODC AREA 1/2" = 1'-01, /- 2X4 WD STUDS ALL MARKINGS TO BE SANDED OFF WD 09 PT 06 n SLEEPING BAG WALL 1/2" = 11-011 Z 1"X4"SOLID WD SLATS N WD 06 PT 06 SOLID WD SHELF / 91/4" WD 06 PT 06 3/4"X5"WD END PEICE TYP. ROUTED ON BOTH SIDES WD 06 PT 06 2" 5 1/4" 2 SIZE TO SUIT HEFELE a METAL SHELF SUPPORTS ITEM#282.38.708 n CUSTOM SHELF SIDE ELEVATION n SLEEPING BAG STORAGE SECTION SANDED MARKINGS TO BE LJ 3" = 1'-0" SANDED OFF WD 09 PT F6 i 3/4"X5"WD END PEICE TYP. WD 06 PT 06 GC TO PROVIDE(12) 1'THICKX& 3/4"X9 1/4"SOLID WD SHELVES `r 3/4"X41/2"WD SLATS BUTT JOINTED N TYP 06 PT 06 6 BACKPACK WALL - N WD 08 PT 08 1/2" = 1'-0" 2x10 RESAWN DOUG FIR FRT WD BASE 1X2 WD BLOCKING TO SUPPORT SHELVES TYP - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - " - - - - - - - ._ - - 3/4"X4 112"WD SLATS BUTT WD 09 PT 08 JOINTED ATTACHED TO FACE 3/4"X5"WD END PEICE TYP. OF WD STUDS WD 06 PT 06 N WD 06 PT 06 r I I N I 5'-0"X 6-0"ENLARGED REGIONAL MAP 1X3 WD SHELF FACE TYP 8Y OWNER WD 09 PT 08 , O ODC WALL m I 5"X3/4"SOLD WD TRIM 1/2" = 1'-0" N � WD 06 PT 06 (V I I I 3/4"X41/2"SOLID WD SLATS A507 - ' ATTACHED TO FACE OF WD STUDS r BUTTJOINTED 3 WD 06 PT 06 KV 02.09.07 ISSUE FOR BID_- No By Dale Description 14'-11" L.L. Bean lV N2'-9" 2'-0" 5-5" 2r-0" .2,_9„ -\ MAP WALL r 1/2" = 1'-0" METAL CLOSET f OF Cohh r ', ROD BRACKET �✓ g C DASHED LINE DENOTES LU C! � SLEEPING BAG STORAGE w UNIT 3/4"X5"WD END PEICE TYP. O ". WD 06 PT 06 w g �, c3 SLEEPING BAG STORAGE SECTION 2 METAL CLOSED FLANGE A507 w CLOSET ROD SUPPORT I G a s' PINHOLES DRILLED INTO EACH w 10 SIM 2X10 VERTICAL STUD 6"O.C. A507 10 ICALLY PINHOLE SIZE TO SUIT SHELF SUPPORT HEFELE A507 6 0 w i A507 EQ EQ EQ EQ EQ EQ EQ EQ METAL SHELF SUPPORTS ITEM #282.38.708 CJ 3/4"X4112"SOLID WD SLATS w m zo BUTTJOINTED N The Shops at Evergreen Walk WD 06 PT 06 w 75 Tamarack Ave Building C, Suite 75 GC TO PROVIDE ID 1"THICKX O n South Windsor, CT 06074 11 8 3/4"X 91/4"SOLID WD w A507 == i SHELVES ' 4 A507 7 MILLWORK DETAILS - (A507 i MARS BETWEENSTUDSALL i �+ p �+ iiii MARKS TO BE SANDED OFF ODS � SLEEPING BAG I 2X4 WD BLOCKNG O W AREA �— 3/4"X41/2"SOLID WD SLATS ATTACHED TO FACE OF WD STUDS v BUTT JOINTED Checked By: Checker WD 06 PT 06 Job No: 06125.00 SLEEPING BAG STORAGE ODC - SLEEPING BAG SLEEPING BAG - ODC AREA 1 - 1 -0 4 112" = 1'-0" 1 1/2" = 1'-0" C:\RevitlSWindsor\125-base_local-sh(Recovery).rvt 2/91200712:47:11 PM i U N Q T N E rn m 0 N L GLASS FISH TANK AND GLASS FISH TANK AND a ASSOCIATED EQUIPMENT ASSOCIATED EQUIPMENT BY LL o BY LL BEAN INSTALLED BEAN INSTALLED BY LL BEAN o NOTE: \ BY LL BEAN VENDOR GC VENDOR GC TO COORDINTE ALL METAL FRAMES, \ TO COORDINTE FINAL \ FINAL INSTALLATION BRACKETS, 2 ETC THIS TEMPERED INSTALLATION-4 \ ' 1/2" SECTION TO B MT 01 GLASS TOP& ' FRONT --- - Ell TOP OF FISH TANK BASE CABINET (U- ADJUSTABLE 1' 2" TEMPERED GLASS a _. PLYWD. SIDE 1X8 FRT WD BLOCKING SHELVES SUPPORTED PANEL BEYOND RANDOM WIDTH GRAY BY BRACKETS ON - a 3/4"FRT FSC PLYWOOD BOARD ABOVE PLATFORM STANDARDS 1'-6" / ¢ FLOOR AT VARYING i HEIGHTS 3'-11"TO 4'-3" V SLIDING DOORS d 4 r• T RANDOM WIDTH GRAY BOARD _. -_ _. _ .. _ _ _ _ _ _ _ _ _ _ WD 01 °u b 3/4"FRT — ABOVE FINSHED FLOOR AT g BEADBOARD u o N c PLYWD.(TYP.) TO VARYING HEIGHTS FROM 5'-0" STONES BUILT UP TO BE v ? ; �r o N u PANEL 2X WD - 3'-9"MAX TO 3'-6"MIN v u o o v BLOCKING °o WD 01 . , DIMENSION TO TOP OF ... ..... o TANK ONE SIDE ONLY v v w i j 3/4"FRT FSC PLYWOOD CABINET SECURED TO HOLD UP A50" 8 11 1 3/4" iv DOOR o c u z TO 300 LBS u o y M U CLAD CABINET DOOR o o rq P. w as o WD 01 < 1 V I d a 1X8 FRT WD BLOCKING CONCEALED COOLER AND 13 BIKE SHOP COUNTER SECTION DISPLAY PLUMBING ACCESS FOR FISH 3/4" = 1'-0" TANK PLATFORM 1'-0" - CABINET LOCK REQUIRED PLATFORM 1'-0" Entry v — 0' - 01, LF rm Entry Level i n FISH TANK SECTION n FISH TANK BACK ELEVATION 3/4" = 1'-0" WD 06 SENSORMATIC 12 13 10 EQUIPMENT MTD PT O6 - - UNDERNEATH COUNTER A508 A508 A50 PL 01 I I POS TERMINAL LOCK Owl- !Zw,EHAFELE / _` _ - PULL-OUT SHELF 6 _.. .._._.._. _ R124.02.920 I HANDLEON 3/4' DRAWER L - J A508 DR&DRAWER W\ - - c_ _= SENSORMATIC KEY (TYP.) - - - LOCK @ FRONT ADJUSTABLE Q i SLIDING DOORS s EDGE OF CABINET PLYWO SHELF - = i -vim 3/4"FRT 2'-0" 1 1/2" OPEN_ a PLYWD.(TYP.) \ _ r I SENSORMATIC GLASS FISH TANK AND ASSOCIATED i` iv EQUIPMENT MTD @ 2X WD — M BACK OF CABINET EQUIPMENT BY LL BEAN INSTALLED i BLOCKING I - - BY LL BEAN VENDOR GC TO COORDINTE FINAL INSTALLATION 1 3/4" RANDOM WIDTH GRAY BOARD ABOVE FINSHED FLOOR AT VARYING HEIGHTS FROM V-0"TO 5'-4' n BIKE SHOP COUNTER SECTION @ STORAGE n BIKE SHOP COUNTER - EMPLOYEE SIDE RANDOM WIDTH GRAY BOARD ABOVE WD 01 FINSHED FLOOR AT VARYING HEIGHTS 3/4" = 1'-0" 3/4° = 1'-0" FROM 5'-0"TO 5'-4" TEMPERED GLASS WD 01 FRONT PANEL 9" WD 06 10 13 12 PT 06 A508 A508 A508 POS TERMINAL WD 06 CUTOUTINNES TAPER FROM 2'- PULL--OU SHELF r , r _ _ PT 06 6'HOAT TANK TO FINISHED FOR CABLING I i I FLOOR MAX HEIGHT OF STONE IN FRONT GROMMET I I I I I j ; ( OF FISH TANK PULL-OUT SHELF I I i I - i BEADBOARD - BEADBOARD - PANEL i I � j I I I -. - / --- I ' ll - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ADJUSTABLE PLYWD SHELF I I v I I I � � N - N N li 1 I 1 I I PLYWD.TOE N PLATFORM 1'-0" N N 2X WD BLOCKING I I I ( III I I I (I I I KICK 2 3/4" I I I I I I I I ' ; I ' '! . III I iil II � Ilill � N 1 IL Entry Level — Entry ntry Level \ \ M 0' - Orr _ ° - — 0 BIKE SHOP COUNTER SECTION @ POS n BIKE SHOP COUNTER - CUSTOMER SIDE n FISH TANK SIDE ELEVATION (2) FISH TANK FRONT ELEVATION r" 3/4" = 1'-0" 3/4" = 1'-01, KV 02.09.07 ISSUE FOR BID No By Date Description 1 SENSORMATIC EQUIP. 10 13 12 L.L. Bean MTD. UNDERNEATH A508 COUNTER A508 A508 A508 \ 1 � A508 POS 11/2" 1'-11 , 111/2" Sim 3'-6" 1'-6" \ \ \ \ \\ \\\ TERMINAL EDGE OF PLATFORM \ \ conr 8'-2' MAX DEPTH TO SIDE OF FISH TANK It-4" \ \ r — — — — PL 01 MAX DEPTH TO SIDE OF FISH TANK 2'-4„ 1' 0'\ 6'-�' \ \ 1 0 IF —— PL 01 I I BOARD ABOVE GRAY \ COOLER ACCESS DOORS r WD 06 1 FINSHED FLOOR AT WD 06 \\ VARYING HEIGHTS PT 06 L — — J - -i PT FROM 5,_0, TO 5'_4" — 06r 1 EDGE OF PLATFORM RAMP i - HEIGHT OF STONES i� o ON SIDE OF TANK CUT OUT IN PULL-OUT Sim 1/4"TEMPERED GLASS TOP a w FISH TANK BASE V SHELF FOR CABLING 9 A508 5 A508 C. ( � Q B� I�HOP COUNTER - PLAN U3/4" = 1'-0" - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - 8'-2" z F The Shops at Evergreen Walk $,_o„ 75 Tamarack Ave Building C, Suite 75 STONES TAPER FROM 2'- LL South Windsor, CT 06074 6"H AT 1. FLOOR I— TO FINISHED 0 \ WD - - - o ; MILLWORK DETAILS VARYING WIDTHS - - - - - - 3/4"FRT PLYWOOD 0 i STONE AT BASE OF FISH TANK 0 a i i ST 03 CV O F I I I T 1X8 FRT WD BLOCKING N PLATFORM 1'-0" II I - - - - - -- - - - - - - - - - - - - -- - - - - -- -- - - - - - -- - - --- - - _- - - -- - -- - -- - -- -- - - - -- - - - - -- - -- - - - .. - - - - - - - - - -- - - -.. _ _ .-_-. _ .- -- - - - ' ! Checked By: Checker __.. .. ... _...-- . -._. ---... ._._._. _...----- -. ..__.. . - SET STONES ON Jab No: 06125.00 MORTOR BED MAX WIDTH OF SURROUNDING STONES 11'-10" n FISH TANK PLAN SECTION �1 FISH TANK SIDE ELEVATION n FISH TANK ENLARGED PLAN U 3/4 - 1 0 3/4" = 1'-04, 3/4 - 1 0 - ---- - ewt 125-base_IocalJen.nrt _ _ 2/9/2007 1:53:47 PM I I WD FRAMED MIRROR MS-07 7 1/2" c ui 2, 2 (2)2'-0"L5 FIXTURE BEYOND y a m SPLASH E SS 01 m 1"COUNTERTOP — — — — — — — — — — — — — — — o 04 I SS 01 •c d 3/4"BARN BOARD FACE , , U 14 D 01 I I 11 BARN BOARD TO MEET TRIM O A509 'v I I I (4)4'-0"L5 FIXTURE BEYOND 4"X2"SOLID WD BLOCKING WD 09 I I I II II Q 5"X5"(OR APPROXIMATE) LEGS FOR EACH TABLE SHOULD I I MATCH M o WD 07 I I I I V / I I 7 112"CASING TO WRAP q 4"X4"MTL SLEAVE AT BASE OF o o INSIDE WINDOW BOX II � y LEG TYP. I MT 01 I I I n � N � Cn I60^ 3o " 6 GLIDES TYP. I I I I 1'_2„ rrA n m° w 13 RESTROOM SINK SIDE SECTION I I / I I WD 06 / I 2X COUNTER `° I I I I PT 06 II II II II II II II II II II o II II I I I FINISH FLOOR II II d 1"COUNTER TOP I 1a � A509 I I I — 2'L5 FIXTURE BEYOND 4"X2"SOLID WD BL G L � L -J _ WD 09 5"X5"(OR APPROXIMATE) LEGS -- — — — — — — — — — _ _ __ — — — — — — — — — — — — — (V Q fV FOR EACH TABLE SHOULD MATCH N N WD 07 4 MONOGRAMMING WINDOW SECTION 3/4" = 1'-0" 4"X4"MTL SLEAVE AT BASE OF FINISH FLOOR LEG TYP. MT 01 GLIDES TYP RESTROOM SINK FRONT SECTION 12 1" - 1'-0" 8 FITTING ROOM MIRROR ELEVATION SEE WALL TYPE FOR WALL FINISH FORMED STAINLESS STEEL(CG-50) 96"LENGTHS MIRROR FED INSTALLED BY GC TYPE 430 #4 SATIN FINISH BLOCKING TO 16 GUAGE 0.059" 13 A509 OFFSET MIRROR& _• t 118"RADIUS A509 g SUPPORT L5 FIXTURE - - - -•--- - - • ----- -- - v NOTE: INSTALL CORNER GUARDS 5'-2" FOR ALL OUTSIDE CORNERS IN (V - m STOCKROOM 1'-4" 10" V-8" 10" 6" EQIle . EQ. LS Ile FIXTURE(TYP.) SOAP DISPENSER RECESSED FITTING ROOM MIRROR DETAIL INTO COUTERTOP TYP, O 1 1/2" 0 0 0 0 O - 0 0 4"X3/4"SOLID WD TRIM WD 06 PT 06 CEILING 3 1/2"X 3/4"WD TRIM S' - 0" \ WD 09 PT 08 I . I! I II I ' II I it jI I 1 1/2:X 3/4"WD TRIM n METAL CORNER GUARD DETAIL RESTROOM SINK PLAN �..• I ! ; '; j I j I ! WD 09 PT 08 5/8"GWB SEE PLAN FOR TYPE j 3/4"THICK RANDOM WIDTHS TO FIT �:•.. IIi ' � lii, � ; I ' � ' � j ICI III Ij II iI i � Ii jI WD 09 PT 08 1/2"FRT PLYWOOD 0 \ I j j I ( I I I I I SCRIBE ALL EDGES OF COUNTER TO WALLS a j I I I WD 08 FRONT 11 RIM 10 LL - . 3/4"X1 1/2"WD TRIM FIRE EXTINGUISHER CABINET tcv oz.os.a� ISSUE FOR BID lll cV WD 09 PT 08 I SEE SPECS FOR MODEL NO. No B Date Descri t,on / „ DTRIM m = i I I Y a' .\ L! b &MANUFACTURER SIZE \ \• \ a `� N \' 1"THICK PULL OUT SHELF EXTENSION � � I o \ WD 09 PT 08 0 L.L. Bean ;\ ` \` '• a III 1 I I I 1 III f I l i I l DRAWER WITH 51/2"DRAWER FRONT 0 M WD 09 PT 08 I FIRE EXTINGUISHER 1/2"PLYWOOD SHELFSUPPORT r` AND STANDARD BLOCKING BEADBOARD i Mill I i F I �� ! I WD 10 PT 08 1 ... . . . . . . . . . .. . . . , .'. . ,- HEAVY DUTY DRAWER GLIDE I l FULLL EXTENSION WITH ,\., 5 112"X 34'WD BASE HOLD OPEN OPTION AND n TOUCH LATCH FEATURE \� WD 09 PT 08 PROVIDE BOTH SIDE FOR DRAWER AND SHELF EXTENSION BOTTOM OF CABINET @ 1'-1 0"AFF -n FITTING ROOM BUILT-IN PLAN SECTION FITTING ROOM BUILT IN SECTION 6 - „ FIRE EXTINGUISHER SECTION DETAIL BARN BOARD TO OVERLAP DOOR TRIM The Shops at Evergreen Walk i 1/4"- 1/2"TYP. 75 Tamarack Ave I TRIM WD. SLATS AS 3/4"WD Building C, Suite 75 5" 2'-0" 2" 2'-0" 5" REQUIRED TO � WD 09 PT 06 .— . �. . . . . . ACCOMODATE BENCH � SEE PARTITION TYPE FOR WALL I South Windsor, CT 06074 SOLID WD.TRIM @ FRONT EDGE OF INTERIOR DETAILS CONTINUOUS 2X2 STL. =. - BARN BOARD — — — —— — — —T — — — — BENCH 3 5/8 MTL STUD ' ANGLE FASTENED TO w _ BLOCKING ON 3 WALLS WD 09 PT 06 PROVIDE MTL CORNER BEAD 2"X4"WD BLOCKING � z o WD 09 ( A602 - - - - - - - - - - - - - - 2 t_ \ N t 1X3 WD STRAPPING A509 Checked By: Checker =t FIRE EXTINGUISHER CABINET, Job No: 06125.00 LEGS CONTINUE FLOOR, BASE& SEE SPECS FOR MODEL NO.& WD 07 ^ . . . . s v �'� � WALL FINISHES UNDER BENCH MANUFACTURER SIZE EXISTING CONCRETE SLAB 3/4"BARNBOARD FACE PROVIDE BLOCKING TO RECEIVE WD 01 CABINET n RESTROOM SINK PLAN SECTION A509 n BARNBOARD TO DOOR DETAIL n SECTION THROUGH ADA BENCH FIRE EXTINGUISER CABINET PLAN DETAIL 1 = 1 -0' U 3 = 1 0 _ . 1 1/2 = 1 0 1 1/2 = 1 -0 C.1RevitlSWindsor1125-base_local-sh(Recovery).rvt _ _._. _ ____ ... . .----_.__ - „ 7 12:47:48 PM U 1 LAYER 5/8"'TYPE X"GWB W m s ACOUSTICAL SEALANT y DEFLECTION HEAD TRACK DEFLECTION HEAD TRACK T m E @ 1X FRT WD STRAPPING T-0"O.C. 0 N �- ACOUSTICAL INSULATION L rn T 1 LAYER 1/2"FRT PLYWOOD o 1 LAYER 5/8"'TYPE X"GWB v 1X8 SOLID WD CAP 1 LAYER"TYPE X"GWB BY LL 2x4 FRT WD HEAD ACOUSTICAL SEALANT LL BEAN SIDE FRT WD STRAPPING T-0"O.C. FINISH FLOOR INTERIOR LIGHT GUAGE STEEL FRAMING FRT 1/2"PLYWOOD n NON RATED PARTIAL HEIGHT WALL CJ b N O -- STRUCTURE ABOVE CASHWRAP SIDE SALES FLOOR SIDE V ¢U a o a u v N N o v ACOUSTICAL SEALANT "u FRT 1/2" BEADBOARD FINISH FLOOR u o p K � 'vwv, caaw GF 2x4 FRT WD STUD FRAMING FRT 1/2"PLYWOOD FINISH FLOOR 4 HOURO RATED PARTITION i SEE MILLWORK AND ELEVATIONS CASHWRAP SIDE CLOSET SIDE FOR WALL DETAILS AND FINISHES EXTERIOR WALL CONSTRUCTION BY LL (EXTERIOR FINISH AND STUDS) f EXTERIOR INSULATION PROVIDED BY LL, FRT 1/2"BEADBOARD ,�;;;� NON RATED PARTIAL HEIGHT WALL 12 - 2X4 WD STUD INSTALLED BY GC 2X4 FRT WD STUD FRAMING TYPE 7:ADJACENT TENENT WALL TYPE 7A: BRICK EXTERIOR FINISH FINISH FLOOR TYPE 7B: BOARD AND BATTEN EXTERIOR FINISH TYPE 7C: EFIS EXTERIOR FINISH SEE MILLWORK AND ELEVATIONS FOR WALL DETAILS AND FINISHES ACOUSTICAL SEALANT TYPE 7,7A, 7B: 1 LAYER 5/8""TYPE X"GWB TYPE 7C: 1 LAYER 1/2"FRT PLYWOOD TYPE 3: 1 LAYER 1/2"FRT PLYWOOD BOTH SIDES: n NON RATED PARTITION 16 - 2X4 WD STUD TYPE 3A: 1 LAYER 5!8"GWB BOH SIDE/1 LAYER EXTERIOR WALL 1/2"FRT PLYWOOD SALES FLOOR SIDE TYPE 3B: 1 LAYER 5/8"GWB BOTH SIDES 3/4"FRT PLYWOOD BOH SIDE SALES FLOOR SIDE 1 1/2"STEEL DECK ° SMOKE STOP @ 10'-0" / PROVIDE CORUGATED METAL DECK OVER METAL JOISTS. ANCHOR PLYWOOD TO METAL STRUCTUREABOVE DECK 10"SMF JOISTS @ 16'O.C. INTERIOR LIGHT GUAGE 3 5/8" C JOIST BOLTED TO STUD 16"O.C. EXTERIOR WALL STEEL FRAMING 7C - NOTE: FRAME CEILING PLATFORM TO ALLOW FOR INSTALLATION OF ACOUSTICAL SEALANT FRT 1/2"BEADBOARD FLUOR LIGHT FIXTURES 7B EXTERIOR WALL ACOUSTICAL CEILING TILE 8'-0"AFF EXTERIOR WALL VOID SPACE CASHWRAP SIDE DEMISING WALL 38 'SMOKE PARTITION-3 5I8"STUD 1 LAYER 5/8""TYPE X"GWB 1° = 1'-0" 1"=1'-0" r SMOKE PARTITION-3 5/8"STUD INTERIOR LIGHT GUAGE STEEL 3A --..—..--- ------ NO FINISH FRAMING 1 -1-0 2X4 FRT WD STUD FRAMING 3 SMOKE PARTITION - 3 5/8" STUD FINISH FLOOR SOUND ATTENUATION INSULATION 1 — 1 0 1 LAYER 5/8"'TYPE X"GWB SEE MILLWORK AND ELEVATIONS VIF DIMENSION WALL TO ENCLOSE COLUMN 1X4 FRT WD TRIM FOR WALL DETAILS AND FINISHES DELECTION HEAD TRACK 3X'FRT PLYWOOD - - 1 1/2"STEEL DECK N RATED PARTITION 15 -2X4 WD STUD n NON RATED PARTIAL HEIGHT WALL PLATFORM AT WALL INTERSECTION - 3 5/8" STUD PROVIDE CORUGATED METAL -01, ' 1" = 1'-0" TYPE 6: 1 LAYER 5/8""TYPE X"GWB DECK OVER METAL JOISTS. TYPE 6A: 1 LAYER 3/4"FRT CEDAR ANCHOR PLYWOOD TO METAL SHIP LAP SIDING(ON OPPOSITE DECK 39'FRT PLYWOOD WALL OF MIRROR) 10"SMF JOISTS @ 16'O.C. 1 1/2"STEEL DECK C JOIST BOLTED TO STUD 16"O.C. PROVIDE CORUGATED METAL ACOUSTICAL CEILING TILE 8'-0"AFF DECK OVER METAL JOISTS. INTERIOR LIGHT GUAGE STEEL FRAMING NOTE:FRAME CEILING PLATFORM ANCHOR PLYWOOD TO METAL TO ALLOW FOR INSTALLATION OF DECK FLUOR LIGHT FIXTURES 10"SMF JOISTS @ 16'O.C. STRUCTURE ABOVE TYPE 2A: PLATFORM CEILING ACOUSTICAL SEALANT CONTINUES ABOVE C JOIST BOLTED TO STUD 16"O.C. NOTE: FRAME CEILING PLATFORM FINISH FLOOR RESTROOM SIDE TO ALLOW FOR INSTALLATION OF FLUOR LIGHT FIXTURES ACOUSTICAL CEILING TILE 8'-0"AFF FRT 1/2"PLYWOOD 6A NON RATED PARTIAL HEIGHT WALL-3 5/8"STUD SOUND ATTENUATION INSULATION W_1 02.09.07_ Issue FOR BlD _ 1"= 1'-0" No I By I Date Description 1/2"FRT PLYWOOD INTERIOR LIGHT GUAGE STEEL L.L. Bean VOID SPACE CLOSET SIDE NON RATED PARTIAL HEIGHT WALL - 3 5/8" STUD FRAMING �® '® INTERIOR LIGHT GUAGE STEEL U -0° 1 LAYER OF 5/8""TYPE X"GWB /, o� oon FRAMING /�,� FINISH FLOOR ; NO FINISH SOUND ATTENUATION INSULATION ' 2X4 FRT WD STUD FRAMING FINISH FLOOR DIMENSION %/ VARIES a °•. =; ';; :, ',J . a ' ;' SEE MILLWORK AND ELEVATIONS � NON RATED PARTIAL HEIGHT WALL PLATFORM ABOVE - 3 5/8" STUD DEFLECTION HEAD TRACK NONRATED CHASE WALL - 2A FOR WALL DETAILS AND FINISHES TYPE 5:FURR OUT BEAM AND COLUMN VIF DIMENSIONS 2 NON RATED CHASE WALL 1X4 FRT WDTRIM �` � `• n NON RATED PARTITION 14 - 2X4 WD STUDS 3/4"FRT PLYWOOD `cc U 1" = 1'-0" 1 1/2"STEEL DECK cJ PROVIDE CORUGATED METAL 1/2"FRT PLYWOOD — 1X8 SOLID WD CAP DECK OVER METAL JOISTS. DEFLECTION HEAD TRACK ANCHOR PLYWOOD TO METAL ------ — 2x4 FRT WD HEAD DECK TYPE 1A: 1 LAYER OF 5/8"'TYPE X' 10"SMF JOISTS @ 16'O.C. GWB SALES FLOOR SIDE SIDE ONLY. FRT WD STRAPPING 2'-0"O.C. SALES FLOOR SIDE 1 LAYER OF 5/8"'TYPE X" The Shops at Evergreen Walk C JOIST BOLTED TO STUD 16"O.C. GWB BOTH SIDES 75 Tamarack Ave Building C, Suite 75 South Windsor, CT 06074 FRT 1/2"PLYWOOD ACOUSTICAL CEILING TILE 8'-0"AFF 1X FRT WD STRAPPING 2'-0"O.C. BOTH SIDES PARTITION DETAILS TYPE 5A: 5/8"'TYPE X"GWB ONE SIDE SALES FLOOR SIDE CASHWRAP SIDE NOTE:FRAME CEILING PLATFORM I INTERIOR LIGHT GUAGE STEEL TO ALLOW FOR INSTALLATION OF FRAMING FRT 1/2"PLYWOOD FLUOR LIGHT FIXTURES TYPE 56: NO FINISH -- 3 5/8"STUD PARTITION Checked By: Checker 2x4 FRT WD STUD FRAMING — 1/2"FRT PLYWOOD TYPE 5B: 5/8""TYPE X"GWB(NO STRAPPING) t INTERIOR LIGHT GUAGE STEEL ACOUSTICAL SEALANT Job No: 06125,00 FRAMING FINISH FLOOR SEE MILLWORK AND ELEVATIONS SOUND ATTENUATION INSULATION j FOR WALL DETAILS AND FINISHES 5A NON RATED PARTITION-3 5/8"DOUBLE STUD 1A NON RATED CHASE WALL A601 N RATED PARTITION 13 -2X4 WD STUD �01 NON RATED PARTIAL HEIGHT WALL PLATFORM EDGE - 3 5/8" STUD NON RATED PARITION - 6" DOUBLE STUD 1 NON RATED PARTITION -0" U 1" = 1'-0" U 1" = 1'-0" 1" = 1'-0" __.._ . ... -_._ - - _ _ _ __ _ ... ----- _ ._. _ - _ . . _ -. .. _ . . _ - _ _. ._.. _._.. __. --- --' .._... _.. --------- ---- --- -_ . C:1Revh\s ndsor\125-base-local-sh(Recovery).rvt 2/9/2007 12:48:08 PM N Door Hardware Schedule DOOR SCHEDULE A PADDLE HANDLES TYPE: "BEAVE-TAIL D PULL WITH PLATE: US10B I CLASSROOM/CLOSET LOCKSET: US26D From Door Size Frame CANOE PADDLE",TA48010 FROM LL BEAN PUSH PLATE:4"X 16"SQUARE CORNERS (PAIR) NO Room To Room Wth H t Thk T Mat Fits T Mat Fin Hdwr Set Notes (PAIR) US10B HINGES:41/2"X 41/2"US26D(PAIR) g Yp Yp T PADDLE MOUNTING HARDWARE: LL BEAN HINGES:41/2"X 41/2"US10B KICKPLATE: 8"HEIGHT US26D(PAIR) 101 6'-0" 8'-0" 2" 1 MTL SEE NOTES A FINISH TO MATCH STOREFRONT FRAMING(KAWNEER m PADDLE HANDLE MOUNTING KIT FROM CLOSER: US10B KICKDOWN DOOR HOLDER:US26D VESTIBULE EXTERIOR _ ANTIQUE BRONZE) E FREEPORT HARDWARE(PAIR) KICKPLATE: 8: HEIGHT US10B (PAIR) 102 6'-0" 8'-0" 2" 1 MTL SEE NOTES Al FINISH TO MATCH STOREFRONT FRAMING(KAWNEER m PUSH PLATE:4"X 16"SQUARE DOOR SILENCERS CLOSER WITH STOP: US26D (PAIR) VESTIBULE EXTERIOR ANTIQUE BRONZE) o CORNERS,US10B(PAIR) WALL STOP: CONVEX US108 DOOR SILENCERS(PAIR) 103 6'-0" 8'-0" 2" 1 MTL SEE NOTES B FINISH TO MATCH STOREFRONT FRAMING KAWNEER N POWER ASSIST DOOR OPERATORS: INSTAKEY(PAIR) SALES AREA VESTIBULE ANTIQUE BRONZE) HORTON SERIES 7000, CONCEALED rn OPENER WITH BEA SWING SCAN 104 SALES AREA VESTIBULE 6'-0" 8'-0" Z. 1 MTL SEE NOTES 81 FINISH TO MATCH STOREFRONT FRAMING(KAWNEER Q SENSOR(PAIR) ANTIQUE BRONZE) U CONTINUOUS HINGE SETS:US10B(PAIR) 105 SALES AREA WOMEN'S 4'-0" 7'-0" 1 WD-06 PT-06 CASED OPENING KICKPLATES:8"HIGH, US1oB(PAIR) FITTING ROOM INSTAKEY 106 WOMEN'S WFR 2'-6" 6-8" 2" 3 PINE PT-06 2 WO-06 PT-06 C WEATHERSTRIP SADDLE THRESHOLD: DARK BRONZE,5" FITTING ROOM X1/2"RISE 107 WOMEN'S WFR Z-6" 6'-8" 2" 2 PINE PT-06 2 WD-06 PT-06 C FITTING ROOM Al PADDLE HANDLES TYPE: "BEAVE-TAIL E EXIT DEVICE WITH ALARM: U810B J OFFICE LOCKSET: US26D 108 WOMEN'S WFR 2'-6" 6'-8" 2" 3 PINE PT-06 2 WD-06 PT-06 C CANOE PADDLE",TA48010 FROM LL HINGES:4 1/2"X 4 1/2" US10B HINGES:4 1/2"X 4 1/2"US26D FITTING ROOM BEAN(PAIR) CLOSER: US10B WALL STOP: CONVEX US26D 109 WOMEN'S WFR 2'-6" 6-8" 2" 5 PINE PT-06 2 WD-06 PT-06 C PADDLE MOUNTING HARDWARE: LL CLOSER: US26D FITTING ROOM BEAN PADDLE HANDLE MOUNTING KIT KICKDOWN HOLDER: US26D V FROM FREEPORT HARDWARE(PAIR) DOOR SILENCERS 110 WOMEN'S WFR 2'-6" 6'-8" 2" 3 PINE PT-06 2 WD-06 PT-06 C a PUSH PLATE:4"X 16"SQUARE !NSTAKEY FITTING ROOM ' CORNERS,US10B(PAIR) 111 WOMEN'S WFR 2'-6" 6'-8" 2" 2 PINE PT-06 2 WD-06 PT-06 C S {: CONCEALED CLOSER WITH STOP: °f u US108 q u y N N o CONTINUOUS HINGE SETS: US10B(PAIR) 112 WOMEN'S WFR 2--6" 6'-8" 2" 5 PINE PT-06 2 WD-06 PT-06 C o N v FITTING ROOM KICKPLATES:8"HIGH, US106(PAIR) y d INSTAKEY 113 WOMEN'S WFR 3'-0" 6-8" 2" 4 PINE PT-06 3 WD-06 PT-06 C ADA FITTING ROOM DOOR v G WEATHERSTRIP FITTING ROOM rn S o c SADDLE THRESHOLD:DARK BRONZE,5" 114 SALES AREA HALL T-0" T-0" 4 WD-06 PT-06 CASED OPENING " e X 1/2"RISE wq P2 p' 115 HALL WOMEN'S 3'-0" T-0" 1 1/2" 6. HM PT-08 5 HM PT-OS D WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME RESTROOM BOTH SIDES B PADDLE HANDLES TYPE: "BEAVE-TAIL F EXIT DEVICE WITH ALARM: US32D K PRIVACY LOCKSET: US26D 116 HALL MEN'S T-0" 7'-0" 1 1/2" 6. HM PT-08 5 HM PT-08 D WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME CANOE PADDLE",TA48010 FROM LL HINGES:4 1/2"X 41/2"US32D HINGES:41/2"X 41/2"US26D RESTROOM BOTH SIDES BEAN(PAIR) RIM CYLINDER:626 CLOSER WITH STOP: US26D PADDLE MOUNTING HARDWARE: LL CLOSER:AL DOOR SILENCERS 117 HALL EGRESS HALL T-0" 7'-0" 1 1/2" 6 HM PT-08 7 HM PT-08 E WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME BEAN PADDLE HANDLE MOUNTING KIT SWEEP:AL INSTAKEY HALL SIDE ONLY FROM FREEPORT HARDWARE(PAIR) WEATHERSTRIP: AL 118 EGRESS HALL EXTERIOR 3'-0" T-0" 1 1/2" 6 HM PT-08 10 HM PT-08 F PAINT DOOR AND FRAME HALL SIDE ONLY DOOR SEE SCHEDULE DOOR SEE SCHEDULE PUSH PLATE:4"X 16"SQUARE THRESHOLD:5"X 1/2"HEIGHT AL 119 SALES AREA STOCK ROOM 3'-0" T-0" 1 1/2" 8 HM PT-08 7 HM PT-08 G WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME WOOD FRAME CORNERS,US10B(PAIR) INSTAKEY SALES SIDE ONLY 2"MTL FRAME, PAINTED POWER ASSIST DOOR OPERATORS: DOOR SILENCERS 120 STOCK ROOM MONOGRAMMI 3'-0" T-0" 1 1/2" 6 HM PT-08 10 HM PT-08 G WD 06 PT 06 SEE DOOR SCHED. HORTON SERIES 7000,CONCEALED OPENER WITH BEA SWING SCAN NG RM SEE PARTITION SEE PARTITION SENSOR(PAIR) 121 STOCK ROOM UTILITY CLST 3'-0" T-0" 1 112" 6 HM PT-05 10 HM PT-08 H UNDERCUT DOOR LEGEND FOR LEGEND FOR CONTINUOUS HINGE SETS: US10B(PAIR) 122 STOCK ROOM EMPLOYEE T-0" T-0" 6 HM PT-05 CASED OPENING WALL TYPE WALL TYPE KICKPLATES:8"HIGH, US10B(PAIR) LOUNGE 'v WEATHERSTRIP 123 SHOWER RM EMPLOYEE 3'-0" T-0" 1 1/2" 6 HM PT-05 10 HM PT-08 K UNDERCUT DOOR O SADDLE THRESHOLD:DARK BRONZE, 5" LOUNGE X 112"RISE z z 124 STOCK ROOM TELJCOM RM 3'-0" T-0" 1 1/2" 6 HM PT-05 10 HM PT-08 H UNDERCUT DOOR g g B1 PADDLE HANDLES TYPE: "BEAVE-TAIL G PULL WITH PLATE: US10B L OFFICE LOCKSET: US26D 125 STOCK ROOM WORKROOM 3'-0" T-0" 1 1/2, 6 HM PT-05 10 HM PT-08 J UNDERCUT DOOR w to w CANOE PADDLE",TA48010 FROM LL PUSH PLATE:4"X 16"SQUARE HINGES:4 1/2"X 4 1/2"U826D 126 WORKROOM SAFE RM 3'-0" 7'-0" 1 1/2" 6 HM PT-05 10 HM PT-08 L UNDERCUT DOOR w w BEAN(PAIR) CORNERS US10B CLOSER WITH STOP: US26D 127 WORKROOM OFFICE 3'-0" T-0" 1 1/2" 6 HM PT-05 10 HM PT-08 L UNDERCUT DOOR PADDLE MOUNTING HARDWARE:G HINGES:41/2"X 41/2"US1 DB DOOR SILENCERS 128 STOCK ROOM SALES AREA 3'-0" T-0" 1 1/2" 8 HM PT-08 7 HM PT-08 G WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME BEAN PADDLE HANDLE MOUNTING KIT KICKPLATE: S"HEIGHT US108 KICKDOWN HOLDER: US26D SALES SIDE ONLY FROM FREEPORT HARDWARE(PAIR) WALL STOP: CONVEX US10B INSTAKEY PUSH PLATE:4"X 16"SQUARE CLOSER: US106 129 SALES AREA STOCK ROOM T-0" T-0" 1 112" 8 HM PT-08 7 HM PT-08 G WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME CORNERS, US10B(PAIR) KICKDOWN DOOR HOLDER: US10B SALES SIDE ONLY 1/4" 1/g CONCEALED CLOSER WITH STOP: DOOR SILENCERS 130 SALES AREA RETURNS 8'-0" T-0" 8 WD-06 PT-0 6 CASED OPENING q q" US10B CLASSROOM/CLOSET 131 STOCKROOM LOADING DOCK 8'-0" 6'-6" 2" OVERHEAD COILING DOOR BY LANDLORD CONTINUOUS HINGE SETS: US10B(PAIR) 4"WOOD TRIM ON KICKPLATES:8"HIGH, US10B(PAIR) 132 STOCKROOM EXTERIOR 31.0" T-0" 1 1/2, 6 HM j PT-08 F DOOR AND FRAME BY LANDLORD, HARDWARE BY GC WEATHERSTRIP 133 SALES AREA STOCK ROOM 5'-0" 9'-6" 1 1/2" 7 HM PT-08 9 HM PT-08 I WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME WD 06 PT 06 SADDLE THRESHOLD: DARK BRONZE, 5" SALES SIDE ONLY X 1/2"RISE 134 RETURNS RETURNS 3'-0" 7'-0" 1 1/2" 6. HM PT-08 7 HM PT-08 E WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME n WOOD DOOR FRAME n MTL DOOR FRAME W/WD TRIM CLST SALES SIDE ONLY v C HINGES:41/2"X 4 1/2"US10B H CLASSROOM/CLOSET LOCKSET: US26D 135 RETURNS STOCK ROOM T-0" T-0" 1 1/2" 6. HM PT-08 7 HM PT-08 G WOOD TRIM WD-06 FINISHED PT-06 APPLIED TO FRAME 3" = 1'-0" U 3" = 1'-0" WALL STOP: CONVEX US10B HINGES:41/2"X 4112"US26D SALES SIDE ONLY PRIVACY LATCHSET: US106 KICKPLATE:8"HEIGHT US26D 136 SALES AREA MEN'S FITTING 4'-0" 7'-0" 1 WD-06 PT-06 CASED OPENING DOOR SEE SCHEDULE SLIDEBOLT KICKDOWN DOOR HOLDER: US26D ROOM DOOR SEE SCHEDULE OCCUPIEDIUNOCCUPIED INDICATOR CLOSER WITH STOP: US26D 2"MTL FRAME, PAINTED DOOR SILENCERS 137 MEN'S FITTING MFR 2'-6" 6'-8" Z. 5 PINE PT-06 2 WD-06 PT-06 C SEE DOOR SCHED. 2"MTL FRAME, PAINTED INSTAKEY ROOM SEE DOOR SCHED. 138 MEN'S FITTING MFR 2'-6" 6'-8" 2" 3 PINE PT-06 2 WD-06 PT-06 C SEE PARTITION ROOM LEGEND FOR SEE PARTITION 139 MEN'S FITTING MFR 2'-6" 6'-8" 2" 2 PINE PT-06 2 WD-06 PT-06 C WALL TYPE LEGEND FOR ROOM WALL TYPE 140 MEN'S FITTING MFR 2'-6" 6'-8" 2" 3 PINE PT-06 2 WD-06 PT-06 C ROOM Z 141 MEN'S FITTING MFR N-0" 6'-8" Z. 4 PINE PT-06 3 WD-06 PT-06 C ADA FITTING ROOM DOOR ROOM w d 142 CASHWRAP CW CLOSET 3'-0" 7'-0" 1 1/2" 8 HM PT-08 7 HM PT-08 A m 143 SALES AREA BIKE SHOP 3'-0" 6'-8" 2" 4 PINE PT 06 3 WD-06 PT-06 C 144 SALES AREA BIKE SHOP T-4" T-0" 11 WD-06 PT-08 CASED OPENING S_0.1 N 4" 4"WOOD TRIM ON SALES OPTIONAL VISION FLOOR SIDE PANEL,LOCATIONS 3'-0" T-0" TO BE VARIFIED BY WD 06 PT 06 ARCHITECT VISION PANELS 3'-0" n MTL DOOR FRAME W/VVD TRIM ONE SIDE METAL DOOR FRAME 11-011 311 i / \ El ID 4"X3/4"WD M CASING TYP. ,' s v / \ 4"X3/4"WD PT 06 v A - CASING TYP I WD 06 r to PT 06 3/4" 4 314" 3/4" ` • El \ / n CASED WOOD JAM n CASED WOOD HEADER \ / ` \ � � I El i KV 02.09.07 ISSUE FOR BID � � � ` � � � � � _ No By Date Description U 3" = 1'-0" 3" = -V-0" L.L. Bean 8 7 6 5 4 3 2 1 n DOOR TYPES � t 4" 5'_0-- 4 1/2" v Q q, 3'-33 4„ 2 3,_0, 2„ No/ 4, 8-_0, q q 3'_0„ 4, 2„ 3,_0 2, q„ 3'_0 q, 4, 3,_0, q, q, 3'_0 4 4 2,_6„ q„ 4,0„ q„ -j m -- -- q U V N - — 4 `v v N v C A602 "v v rn to ¢\ C, N� - N\ N N\ N\ N\ co fn N) IT ) 1 1 �, �/I /I o The Shops at Evergreen Walk a a ¢} ¢� c a 75 Tamarack Ave 4 3 75 2 4 3 5 2 2 A602 A602 A602 A602 A602 A602 A602 6 ® 6 A602 Building C, Suite T South Windsor, CT 06074 o a n r o 0 0 A602 A602 DOOR AND HARDWARE SCHEDULE AND DETAILS Checked By: Checker Job No: 06125.00 Li LJ 11 10 9 8 7 6 5 4 3 2 1 r 1 A602 FRAME TYPES 1/2" = 1'-01, C:\RevitlSWindsor1125-base local-sh(Recovery).M 219/200712:48:12 PM i -------- . --_------'----'------ . . ..----- ._._._ --------..__-.... _.._.. .- _..__. -------------_ - _ _ ... ------ -------_ ..------ . . - . - ___..._. ...._ _._. _.- ---.___- - __..____..-- ----------------- _..------- --...-------- c FINISH LEGEND U O N Type MANUFACTURER DESCRIPTION COLOR/ITEM# TYP. LOCATION NOTES C 01 USG DONN DX15116"EXPOSED TEE GRID WHITE BOH, OFFICE AREAS, STAFF LOUNGE RADAR TILE 24"X48"SQUARE EDGE LAY IN ° CC 01 NIA STAINED CONCRETE CUSTOM COLOR RETAIL PATH SEE PROJECT MANUAL FOR SPECIFICATION 2 m m CC 02 N/A SEALED CONCRETE TBD BOH,STAFF AREAS SEE PROJECT MANUAL FOR SPECIFICATION ro 0 CP1 01 MATS INC. SUPREME NOP ROLLED GOODS NATURAL#05 SALES FLOOR s o, 311?1 02 SHAW CONTRACT CARPET "STEPPIN'OU7' NEAT EW24#59412 KHAKI SALES FLOOR i T 0 CT 01 DALTILE CERAMIC TILE x735 ALMOND-3"x 6"TILE RESTROOMS USE GROUT GR-01; INSTALL IN A RUNNING O BOND PATTERN CT 02 AMERICAN OLEAN CERAMIC TILE CH-75 CANVAS-6"x 6"TILE STAFF LOUNGE RESTROOM USE GROUT GR-02 GR 01 TBD GROUT TBD TBD TBD GR 02 TBD GROUT TBD TBD TBD GR 03 TBD GROUT TBD TBD TBD GR 04 TBD GROUT TBD TBD TBD A 01 I MATS INC. WALK OFF GRATE DUALTRACK SUPREME NOP NATURAL#05 INSERTS VESTIBULE RECESSED o MT 01 UTOPIA RAW MILD STEET CLEANED AND SEALED W/PT-09 FIXTURES, STANDARDS, ETC. WIRE BRUSH WELD;WHERE G.C. FURNISHING i B MATCH UTOPIA SAMPLE „ o o °u RECLAIMED SHEET STEEL CLEANED AND SEALED W/PT-09 FIXTURES ONLY MT 02 UTOPIA VJ N MT 03 UTOPIA PAINTED STEEL WHITE PAINT OR MILK PAINT THEN SEALED W/PT-09 PERIMETER WALL STANDARDS ALTERNATE MATERIAL SPEC v z N PL 01 WILSONART LAMINATE PLASTIC LAMINATE 4845-60 TWILIGHT ZEPHYR BIKE COUNTER SURFACE U n rn o o � '5 iW P:1P u 5 PT O1 THE OLD FASHIONED MILK PAINT CO. MILK PAINT LIGHT CREAM SALES AREA WALLS, FIXTURES FOR FINISH SEE PROJECT MANUAL PTABENJAMIN MOORE PAINT GREENBRIER BEIGE HC-79 RETAIL WALLS,BEAMS,COLUMNS, FOR FINISH SEE PROJECT MANUAL CEILING, HVAC, PIPES,JOISTS PT 1 03 1 BENJAMIN MOORE PAINT LOUISBURG GREEN HC-113 FITTING ROOMS, RESTROOMS FOR FINISH SEE PROJECT MANUAL PT 04 CABOT SEMI TRANSPARENT SIDING STAIN COLOR TBD FOOTWEAR WALLS, FIXTURES APPLIED BY OWNERS FIXTURE VENDOR CONTAC VENDOR FOR TOUCH UP KIT IF REQUIRED PT 05 BENJAMIN MOORE PAINT SIMPLY WHITE OC-117 BOH, STAFF AREAS FOR FINISH SEE PROJECT MANUAL PT 06 TBD TRANSPARENT FINISH CLEAR,MATTE GEAR WALLS,CASHWRAP,BIKING WALLS,VARIOUS TRIM AND BASE PT 07 TNEMEC PAINT KINDLING 83BR BEANS,COLUMNS, RAIN PIPES FOR FINISH SEE PROJECT MANUAL PT 08 BENJAMIN MOORE PAINT ACADIA WHITE OC-38 CASHWRAP,RETURNS,FITTING ROOM SEE DRAWINGS FOR LOCATIONS WALLS FOR FINISH SEE PROJECT MANUAL PT 09 HOOD COATINGS PAINT MAGNA SHIELD PRE CATALYZED LAQUER-DULL SATIN SEALER FOR METAL QT 01 MANUFACTURER QUARTZ TILE MINT GREEN#724, V X 1 STAFF AREAS RB 01 ROPPE RUBBER BASE P116 MOSS-RUBBER/COVE BOH, STAFF AREAS BF 01 NEOFLEX RUBBER LFOORING CUSTOM BLEND RUBBER FLOORING J.O.#423-3, 1/8"THICK CAMPING PLATFORM ADD ALTERNATE#5 RT 01 MANUFACTURER RUBBER TILE TBD FIXTURES ONLY SS 01 CORIAN SOLID SURFACE CAMEO WHITE(B) RESTROOM COUNTERS ST 01 VERMONT STRUCTURAL SLATE STONE FLOOR HEATHERMOOR-6"X 6"TILE RESTROOM FLOORS FOR FINISH SEE PROJECT MANUAL USE GROUT GR-03 ST 02 STONEYARD STONE FLOOR HAND INSTALLED; NEW ENGLAND FIELD STONE RETAIL PATH ADD ALTERNATE#2: USE GROUT GR-04 FOR FINISH SEE PROJECT MANUAL ST 03 NIA NEW ENGLAND FIELD STONE ROUND N/A FISH TANK SURROUND BOULDER SIZE MIN. 18"D MAX 36"D WD 01 UTOPIA BARN BOARD FRT GRAY BOARD W/FLAME SEAL FEATURE WALLS SUPPLIED BY OWNER INSTALLED BY GC WDI 02 UTOPIA BARN BOARD BROWN BOARD FIXTURES ONLY SUPPLIED BY OWNER INSTALLED BY GC WD 03 UTOPIA WOOD ROUGH SAWN#2 PINE FIXTURES ONLY WD 04 UTOPIA WOOD RECLAIMED/NON VINTAGE FIXTURES ONLY WD 05 UTOPIA BEAD BOARD VINTAGE FIXTURES ONLY WD 06 UTOPIA WOOD FRT, RE-SAWN AND PLAINED DOUG FIR;W/FLAME SEAL GEAR WALLS,CASHWRAP,BIKING I WALLS,VARIOUS TRIM AND BASE SEE INTERIOR ELEVATIONS WD 07 UTOPIA BARN BOARD GRAY BOARD "WIND BRACES" FIXTURES ONLY SEE DRAWINGS FOR LOCATIONS FOR WALL FINISH ABOVE BASE WD 08 N/A 1/2"PLYWOOD FRT,FSC, INTERIOR SHEATHING, SOFTWOOD,GRADE C PERIMETER WALLS, ETC. WD Og N/A WOOD FRT,FSC, DOUG FIR, FACE GRAIN N/A SEE DRAWINGS FOR WD DIMENSIONS CAULK WHERE TILE BASE WD 10 NANTUCKET BEADBOARD 1/2"THICK SHEET BEADBOARD FRT, FSC, BEADBOARD;2"OC STANDARD BEAD PIS CASHWRAP,RETURNS, RESTROOMS SEE DRAWINGS FOR LOCATIONS MEETS DISSIMILAR MATERIAL WD 11 GEORGIA PACIFIC 3/4"THICK PLYWOOD FRT,T1-11, PINE, ROUGH SAWN, 4"O.C. GROOVES CASHWRAP,BIKE ROOF SEE DRAWINGS FOR LOCATIONS WD 12 N/A 3/4"THICK PLYWOOD FRT,FSC CASHWRAP,BIKE ROOF SEE DRAWINGS FOR LOCATIONS 6"X6"SLATE TILE BASE DF 01 ELMWOOD RECLAIMED TIMBER WOOD FLOOR MIXED HARDWOOD-SKIMMED BARN WOOD-NATURAL RETAIL PATH ADD ALTERNATE#3 (RUSTIC GRADE) FOR FINISH SEE PROJECT MANUAL WM al MCNICHOLS WIRE MESH PART#3658224810, 1/2"OPEN, 120 WIRE DIAM., LOCK RAILINGS AND FIXTURES CRIMP WEAVE, PLAIN STEEL ENTRY MAT _ GLUE DOWN CARPET DOOR 1.7 SCHULTER@-RENO-V SEALANT TO MATCH STONE CONTINUOUS WATERPROOF MEMBRANE GROUT ,'— HEAVY DUTY SADDLE GROUT COLOR (TURN UP WALLS MIN.4") STONE FLOORING I I I i,,. EXISTING CONCRETE STONE FLOORING SLATE FLOOR TILE — EXTRUDED MTL 1.7 5CHULTER@ REND-V i ° Jz, ,y yr SEE FINISH PLAN HEAVY DUTY SADDLE ` �'=— fir ,w . THRESHOLD OVER JOINT FOR LAYOUT CARPET 'Q SEALED CONCRETE °. '_ GROUT I. I I , III J .I . . r . y1' d — ' 7 CARPET TO CONCRETE n THICK MUD SET d d j TT OVERLAP FRAME PAN ° EXISTING CONCRETE e d.F EXISTING CONCRETE •.. ' _ -' p : GLUE DOWN CARPET a : 4 ; •,a e : EXISTING m'• - - CONCRETE SLAB THICK MUD SET DOOR TX 314"DOUBLE BEVEL �. . t- •;tl '. ` ' °`. ' n TILE BASE DETAIL MARBLE TRANSITION STRIP 6" = 1'-0" CERAMIC TILE 3 ENTRY MAT TO STONE xv 02.09.07 SSUE FOR 81D n STONE TO CARPET ` - � _ „ _ — ----.-- -- ---- ,v 6" = 1'-0" 11 �91111�;{ I�1J�MII I�J��11�'•�' ^'r�:° �, i� THIN SET 6 — 1 0 No BY Date Description ENTRY MAT EXISTING CONCRETE ' DOOR L.L. Bean WOOD FLOORING - .'. p,!' - DOOR a COMN CEMENTIOUS UNDERLAYMENT _ 1.7 SCHULTER@-RENO-V e EXTRUDED MTL THRESHOLD OVER JOINT EXTRUDED MTL BUILD-UP AS REQUIRED FOR THRESHOLD OVER JOINT ALIGNMENT OF ALL FLOOR 6 CARPET TO CERAMIC TILE — -,,•, • a`r HEAVY DUTY SADDLE FINISH SYSTEMS " STONE FLOORING o- STAINED CONCRETE INTERIOR EXTERIOR WOOD TRANSITION d , STAINED CONCRETE ry' a ` GROUT :. BOTTOM WEATHER L ,3�" h x CONCRETE THICK MUD SET N d STRIPPING AT E w EXTENT NATURAL CORE W/LOW LUSTER SEALENT TT OVERLAP FRAME EXTERIOR DOOR `a ; . ° EXISTING CONCRETE ' :7', R =;,r;_, r ;a TO EXISTING CONCRETE SEALED CONCRETE PAN .d . e• 's• •.q .-e - a - "i, •d' 'q - 'd ., a • •P SEALED CONCRETE - ' CONCRETE BY LL o- . a +•. ° 21 q 14 ENTRY MAT TO CONCRETE `r n CONCRETE TO EXTERIOR n WOOD TO CONCRETE n STONE TO CONCRETE 2 6" = 1'-0" U 6" = 1'-0„ 6„ = 1'-0" U 6" = 1'-01, STAINED CONCRETE TO CONCRETE �— DOOR 1'-0" ENTRY MAT CONCRETE BY LL The Shops at Evergreen Walk DOOR EXTRUDED MTL 75 Tamarack Ave EXTERIOR INTERIOR THRESHOLD OVER JOINT Building C, Suite 75 EXTRUDED MTL BOTTOM WEATHER South Windsor, CT 06074 WD FLOORING THRESHOLD OVER JOINT STRIPPING AT DOOR EXTERIOR DOOR DOOR SCHLUTER MTL ANGLE r y ENTRY MAT ! FINISH LEGEND AND WD FLOORING ,,Y {a 5 p� UNDERLAYMENT RUBBER QUARTZ TILE ADHERED TO SUB FLOOR ° 5 TT OVERLAP FRAME TRANSITION DETAILS HEAVY DUTY RUBBER TRANSITION STRIP AS 2"X3/4"DOUBLE BEVEL `= r =, v ' TRANSITION STRIP NECESSARY WITH WO FLOORING O MARBLE TRANSITION STRIP ! e. _ ..__ e- ""- a. CEMENTIOUS UNDERLAYMENT CERAMIC TILE s BUILD-UP AS REQUIRED FOR °' N QUARTZ TILE ADHERED ,. GLUE DOWN CARPET e , - - ALIGNMENT OF ALL FLOOR — 4� TO SUB FLOOR I� THIN SET ^n a i''�'k.,^:, r'1'da PAN Checked By: Checker y ' ' ° •e ,,.,.: ' II If °q a _• u /� EXISTING CONCRETE N 9. ° d FINISH SYSTEMS ;. a ° EXISTING CONCRETE d e Job No: 06125.00 a" .N — CEMENTIOUS d _ PAN e .. . • - - _ 'UNDERLAYMENT BUILD UP AS " ° .a EXISTING CONCRETE SLAB a ' ... _ ° - • • '� --- REQUIRED FOR ALIGNMENT . . �a'-" ., - - .° - c : ' z:,� `. • . ' OF ALL FLOOR FINISH 2„ SYS EM '. = a ^ TT OVERLAP FRAME MIN.TRANSITION EXISTING CONCRETE SLAB ^• a• '± ; -': ° n QUARTZ TILE TO CONCRETE _ O WOOD TO CARPET QUARTZ TILE TO CERAMIC TILE ENTRY MAT TO WOOD A603 �-• 6„ = 1'-0„ 11 6" = 1'-0" U 6" = 1'-01, U 6" = 1'-0" 1 EXTERIOR TO ENTRY MAT 6" = 1'-0" _ -_---- --- _._._. .._. __._ . _ _ ..._. _ _ _. _. _ . . .- _--- _ ...... __ _.._. ... . .___ ___ _. . _ _ _ _ .. ... __ --- ._._ . . ._. _.. . __ _.___-- --_____. _ _.__ _ _.__.. _-. .._ ___ __ _. __ .- .... .__ .__ ___..__....... C:1RevitlSWindsor1125-base local-sh(Recovery).rvt 219/2007 12:48:27 PM ------------- ------ ------------- ---- —------- ---------------- --------------- ----------- ------------------- --------------- ---------------- ------ ----------------------------- ---------------- Ru 0 E 0 cm 0 2 1/4" 2X12 JOISTS@ 16"D.C. fzL MITERED 2X12 RIM JOIST BEYOND TRANSITION (TYPICAL FOR WD 12 ALL RAILINGS) WD 11 U GROOVES FACING DOWN o (2)2X12 JOISTS @ STAIR OPENING A �u o a U V cq Cq C> RETURN ALL ENDS TO WALL. CLOSE W/1/4" A Cf tI 2 WELDED PLATE U cl) 0 X 3X3 STL ANGLE HANDRAIL RETURN DETAIL 60, PLYWD WALL FINISH WD OH WD.TREAD&RISER WD 09 WD STRINGER W0 079 1 112' 1 I/Z'O.D. PTD. STL PIPE RAIL PT 02 n)_�STIAIR� LANDING DETAIL 3 0� COUNTERSUNK FASTENER C\1 1/4X3/4"STL.WLL BRACKETS W/"1 1/2"X2 1 1Z'X1A/4"WALL PLATE PT 02 12'-7'�� V -0 BLOCKING BY G.C. STL HANDRAIL BRACKETS 4 0"D.C. MAX A801 rc--\ HANDRAIL ATTACHMENT DETAIL '-f�6- T�-O- STL ANGLE FOR BIKES S CIA 11/2" 1 1/2" 2'- 10" 1 1/2" 1 I/Z' KV 02.09.07 R BID Entry Level CLEAR N, By Date ISSUE FO-77F[e'sanp tion of of, L.L. Bean Bike Sn�Shop Stair Section 111?0'rn 2 z 0 o z LU M 0" < 6 The Shops at Evergreen Walk UP 17 RISERS 1 75 Tamarack Ave FOR BIKES 3X3 STL ANGLE A801 Building C, Suite 75 I South Windsor, CT 06074 CONSTRUCTION DETAILS - BIKE SHOP AREA Checked By: Checker (�)_Bike Shop Stair Handrail Detail BIKE SHOP STAIRS 1 1/2" 1 F.011 Job No: 06125.00 A801 --------- - ----- -- ------- - ------------2/9/2007 12:48:38 PM Cl C m i N U N Q m a m E rn `m m 0 0 N t 0) 'C a d O U ~ U q U.❑� O O N o r pp m q N So Sn� v g v c S u o i i C I 3 - - - - - - - - - - - - - - WOOD FLOORING WDF 01 M 5'-8 1/4" BLACK SAFETY TAPE ,TYP. fo 5'-0 3/4" WDF 01 WOOD FLOORING BLACK SAFETY TAPE,TYP. WOOD TRIM TO MATCH FLOORING 1'-1" 3 112" UP 3/4" 11" SOLID WOOD TREAD TO MATCH i� FLOORING UP VERTICALLY ORIENTED WOOD PLANKS IN RANDOM WIDTHS Wp O6 FRT 3/4"PLYWOOD FRT 2 X 10 WOOD JOISTS FRT 3/4"PLYWOOD SOLID WOOD RISER FRT WOOD SLEEPER — ------ Entry FRT WOOD SLEEPERS,TYP. ,' Ent Level FRT 2 X 10 WOOD JOISTS /,/,,' Entry Level / , Q _ O O' _ On ,''�/ , '/12'- 1 3/4 /' i / /• '' ' , fN 02.09.07-_-ISSUE FOR BID /;' / '' / %%/,%; : ,' � i� �� �>r� No B Date Description — ,% / ,, , ,, , , i i i , / , , , , , , / , / ,, , ♦x , , 0� , , , , .� L.L. Bean PLATFORM EDGE DETAL, TYP. PLATFORM STEP SECTION ' ; ' //' / !,'' %/;' j% //i 1 j, /,' ' 5 n IZ I r' / / ' '/ /3'-91/4";, '/'/', ,' ,10'-3,3/4"; j /i' / UP 71 '� ' '" /" The Shops at Evergreen Walk A802lilt 75 Tamarack Ave HANDRAIL i / '//�/ , !,- /, / Building C, Suite 75 Ent // / ;// / ' / `" ! ' / South Windsor, CT 06074 / , 1 01. /" /i / // / /< CONSTRUCTION / , / ' "P !' = '"-'! DETAILS - PLATFORMS V I '-5 1/2" 4'- 1 1/4" 1 X WD PLANKS @EXPOSED 12 _ SIDES OF RAMP,T YP• 13'-5 1/4" Checked By: Checker WOOD FLOORING ON 3/4" PLYWOOD SUBFLOOR Job No: 06125.00 T-0"T.O. PLATFORM Entry Level ,ON RETE SLAB 0' - of. Entry Level \ T—A802 0' - 0" A802 — — 3 A802 n BOTTOM OF RAMP DETAIL RAMP SECTION, TYP. 6" = 1'-0" 2 1/2" = 1'-0" n HIKING / CAMPING RAISED PLATFORM 1/4 1 0 C:IREVIT PROJECTS\South Windsor1125-base_local_kv.rvt 2/9l2007 1:23:55 PM U C N N N I -U F 0 a ,a a E rn m Io 3X12 FRT RECLAIMED DOUG FIR BEAMS o 2'_6" 2'_6" 2'_6" 2'-6" 2'-6" 1, 2'-6" 2'-6" 2'-6" T-8' IWDI 06 t I a U GC TO INSTALL FRT WD BLOCKING IN WALL BEAMS BEARING ON FR PARTITIONS ") 3X12 FRT RECLAIMED iv DOUG FIR BEAMS 3X12 FRT RECLAIMED GC TO INSTALL FRT ; SIM DOUG FIR BEAMS _ WD BLOCKING IN WALL - 11 WD 06 I WD 06 N 3X3X12"STL ANGLE { A803 BOLTED ST BEAM&WALL 3X3X12"STL ANGLE F , 12 SIM ` o P.OF 4 PER BEAM BOLTED TO BEAM&WALL B.O. BEAM v (TYP. OF 4 PER BEAM) .1 A803 A803 iv Q o 0 0 8 - 0 v :B �� •- N � ' A803 FITTING ROOM FITTING ROOM FITTING ROOM 10 SIDI 0 o c 5 _ ACCESS A803 - N Q) Entry Level 0' - 0.1 I -------------------------------I----- SIM 12 A803 n FR BEAM CONNECTION PLAN DETAIL -ADD ALT. 1 n FR BEAM CONNECTION - SECTION DETAIL -ADD ALT. 1 10 ADD ALT SECTION THROUGH TYP. FR -ADD ALT. 1 n ADD ALT. RCP -WOMEN'S FITTING ROOM -ADD ALT. 1 8 ADD ALT. RCP - MEN'S FITTING ROOM -ADD ALT. 1 U 3" = 1'-0" U 3" = 1'-0" 1/411 = 1'-01, 1/4" = 1'-0" 1/4" = 1'-0" STAIR STEPS AS OCCUR PIPE RAIL AS OCCURS MTL.STANDARDS SET iE FLUSH F&PLYWD.BACK TO n ACCEPTSHELHEL ACCESSORY HARDWARE DEAD BOARD BENCH BACK ACCESSORY HARDWARE MTD.TO STANDARDS b RECLAIMED WOOD RISER/BIN.TBD PIPE RAIL AS OCCURS, SLATS OVER PLYWD SCREW ATTACH TO SIDE SUBSTRATE,VARIOUS RECLAIMED WOOD OF FIXTURE,MT-01 WIDHTS,WD-07 SLATS OVER PLYWD irr RECLAIMED W000 DEAD BOARD BENCH BACK u SUBSTRATE,VARIOUS SLATSOVER PLYWD WIDHTS,WD-0? ba PIPE RAIL AS OCCURS, SCREW ATTACH TO SIDE SUBSTRATE,VARIOUS OF FIXTURE.MT-01 WIOHTS.WD-07 b CABINETRY TO BE _ CABINETRY TO BE VENEER PLYWD w!SOLID SOLID WD.TRIM,PT-0? VENEER PLYWD w1 SOLID W000 EDGES,PT-07 WOOD EDGES,PT-07 STOCK STORAGE CABINETRY TO BE DRAWER(ADD ALTERNATE) — VENEER PLYWD wl SOLID - WOOD EDGES,PT-0? MTL STANDARDS SET ADJ.SHELF ON MTL FLUSH B CK.TO BEAD HARDWARE,COORD.SIZE b WOOD BASE,PT-0? BOARD BACK,TO w/APPAREL FIXTURES,WD-0? <- ?' . ACCEPT SHELF& STL ANGLE TRIM TO ACCESSORY HARDWARE SECURE EDGE OF CARPET SOLID WOOD TREAD WOOD BASE,PT-07 b w/ROUNDED NOSING FIELD-APPLIED SOLID - BEAD BOARD BENCH BACK WD BASE PT-07 b SOLID WOOD RISER(FIN.TED) FLUSHSTANDARDS SET BOAR w/BACK. TO.DEAD SOLI FLOOR JOISTS ON BOARD BACK,TO SOLID WOOD BLOCKS AS ACCEPT SHELF 8 REQUIRED TO ACHIEVE ACCESSORY HARDWARE PLATFORM HEIGHT STOCKSTORAGE DRAWER IPOD ALTERNATE) s FOOTWEAR PLATFORM FIXTURE PLAN SECTION -ADD ALT. 5 n PLATFORM FIXTURE SECTIONS -ADD ALT. 5 s PLATFORM FIXTURE SIDE ELEV-ADD ALT. 5 n PLATFORM FIXTURE ELEVATION -ADD ALT. 5 1/2" = 1'-0" 1/2" = 1'-0" 1/211 = 1'-0" U 1/2" = 1'-01, D C I I 112"THICK,VARIABLE WIDTHS OF W,5",7", RANDOM LENGTHS FROM 1'TO 12' -�-er w-,_.,.,.n:wna sxiu> --+•:..aA.r"n.- _:;n,a uv:urn: r+ sMa:,nr..,a /...vs.rrxaraurz:a.wl ro-'. �e;;x+..wN mc*a=i �M. tasz..w:u..;aava: 1�'•r. w:.xt;raw. n- mv. ..a+"t�4,.n,r•,.-s - a¢�- u , ---------t---- 4j Qy — 1 BOSTIKS BEST MASTIC GLUE ;"-- - ------ -- --- -- - - x wry zr•: - --------- i — --- d � 1/4"FRT PLYWOOD - da EXISTING CONCRETE ----- ---- ------- -- ------ - ----- a ------ - -.--- ---------- - --- ---- — . KV 02.09 ISSUE FOR- -.07 BID -- --- -_ .- -- - -._ - -- - ---Ir-- -- - ----- -- �--- ---- -I — ----- -- - ---- ---- .--- - No By Date Descriptfan A L.L. Bean -- ---- ---- -------- - ---- -- ---------- --- ----- - 101_2 ------------ --------- ' I WOOD FLOOR DETAIL SECTION TYP. -ADD ALT. 3 — - -.-- - -- -- - --- ----- -- � -- - -------- -I -- ; ��col', ..- \ - _.. _. bW`evrS —. — --.— — ___• _ ___. _—.—_-_--- � V / V 1'-1 3/4" -- - ---" - - -- ' -'--- - --- -- -- - - - --- -- - -- - ---- - - - - -- ----- , I _� _ I -I-- sof - ---- ---- -- ---- ---- ----- ------- -- --- -----..----- ----- - ------- - ---- ------ — CD _ (O tO — ♦ N SIM m u iO ( - TYP.@ALL STEPco S--r--iD v' TYP. WD FLOOR CORNER -- ------ --- ------- ---- LD \, -- --- - ---- ------ -- ----- -- -6, -- - - - ---- ---- -- -- - _- - - - - -- - WDFL-01 ----- - --- - - - - - ------ ----- - - - ---- -- ---- - - ----- --- ---- ---- -♦�/ UP - — ` i \�'•-�--- - ----- --- -----,.,_,.�_��.._._�„:_.,.�,:��r__.,_,�_---- -----•-- ----_- --- - - ----- �---------------- ♦ ALIGN The Shops at Evergreen Walk -, 75 Tamarack Ave BuildIn C Suite 75 �. ----- -- -- ------- - - -�- ----Asps- -/- -- -- -- `♦ South Windsor, CT 06074 Ag03- 19'-41/2" --I--I I ~ - --- --I-- --I- - - I - 19'-8 1/2" —I - I -- 7 ' ALIGN FOOTWEAR 7 A803 ♦ FITTING A508 1_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ A803 PLATFORM & F - _ BOTTOM OF RAMP '.. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .10'-43/4"0 _ _ _ _ _ � _ _ _ _ _ _ _ _ _ _ _ 11'-41/4" 6'-T' ROOM BEAMS 10'-10" 11'-7 1/2" 9'-2 112" Checked By: Checker 4'-53/4" 15'-71/2" 9'-7" Job No: 06125.00 --. ------- - -- ' 19'-11 3/4" 23'-7 1/4" IA803 s WOOD FLOOR CORNER PLAN TYP. -ADD ALT 3 FOOTWEAR / KID'S RAISED PLATFORM -ADD ALT. 5 U 3/8" 1 6RevitlS Windsor1125-base-local-sh(Recovery).rvt 2/9/2007 1:56:56 PM f U C N N t° yVMN iv N E INTERIOR CONCRETE SLAB (BY OTHERS) rn m m 0 0 N GRADE BEAM 2 ; (BY OTHERS) S101 a U r--- I-------- ------ ----- ---- = - - - -- - - - ---- I I I I 1 #5 x 1'-6" LONG ® 12" O.C. � � SET 9" INTO PREDRILLED HOLES I -. / I. FILLED w/EPDXY.(T1P. ® PERIMETER) HSS COLUMN I (BY OTHERS) vu j (T.O. SLAB=99'-9%2"), N GRADE,BEAM -- (COORD. w/ARCH.) o v BY OTHERS r� -- - ----� -- -- - L u sill 6"'-"DEPRESSED ONCRETE SLAB- _ - _ SJ L -_ - _ o --------- ---------- - -_- - eg -------- REI F MID-DEP. W2.9x2.9 WWF ;.I E- - T - - -- - - - ¢� m maw B �- J iH (TYPICAL, 1 I ` SEED TAILS)- "{. :' , . 1 i ,li I I I I II I I i y i I .. 1'-6" THICK GRADE BEAM L 0 > o 0 r • j (TYP. @ EXTERIOR �� C Q (� L--L -� = --- --- --=� -------- -- --� --J J CIO PERIMETER) - � C: - - - Q) L- - - _J -- -- ., L -- ----------J � d � c I 1 i 1 n N b-0 I' L O O L VES77BULE GRADE BEAM N C N o V V- N ON TOP OF COL. FIG. (TYP.) FM V U 0 B.O. OF GRADE BEAM 1 - _ � N o -C ELEV = 96'-0" (TYP.) S101 w - ZrzI.L C. C. VESTIBULE SLAB ON GRADE PLAN OFCONN NOTES �i 'No.2478 p`�a 1. COORD. ALL DIMENSIONS WITH ARCH17ECTURAL DRAWINGS 0 5<i p � 2. S✓ - INDICATES SLAB SAWCUT CONTROL JOINT (SEE TYPICAL DETAILS) �SSONA LNG ' 5 HOOKED BARS ENTRY SYS7FM (WHERE ¢ OCCURS, COORD. w/ARCH) ENTRY SYSTEM (WHERE i ® 1P^ p•C w� #5 x 1'-6" LONG ® 12" O.C. OCCURS, COORD. w/ARCH) SET 9" INTO PREDRILLED HOLES 6" DEPRESSED CONCRETE SLAB ON VESTIBULE FILLED w/EPDXY (TYP. O PERIMETER) - 15 MIL VAPOR BARRIER CONT. T/4 DEEP SAWCUT CONTROL JOINT. 15# FELT BOND BREAKER / GRADE REINF. w 6x6-W2.9xWZg / (FILL WI7H JOINT SEALANT). SAWCUTS TO i F_ / FLOOR MAT SYSTEM INTERIOR SLAB MlD-DEPTH BE AT 5'-0" O.C. MAXIMUMU SPA CING WWF ® MID-DEPTH (TYPICAL) 6x6-W2.9xW2.9 WWF \ j (SEE ARCH. DETAILS) / F- (BY OTHERS) L / / (BOTH DIRECTIONS) COORD. w/ ARCH.) T.O. FIN. SLAB X " � I,� • e -x z -x-x x t x 6" CONCRETE SLAB o x-;x-x x -x -` II-II - 24" (2)-#4 CONT Be3=)L r �,� ,y , y _I_I11= 1 -Y -x-x-x n TIES 18" O.0. _ � � 18" CRUSHED 18" CRUSHED _ ° � • y � - • " � Pk P � �''`� ( 18" CRUSHED SLAB THICKNESS (T) a STONE STONE F - STONE 0 1'-6" THICK GRADE r _c? GRADE BEAM NOTE.• rn BEAM (TYP.) * SAW CUT WITHIN 4 HOURS MAXIMUM OF CONCRETE - C I` I I ` ` `� - =�-( (BY OTHERS) PLACEMENT USING AN EARLY-ENTRY SAW. SAW 11 III I YII IINIf= (2)-#5 BARS CONT - ° ° - / o•" 0" VIRGIN SOIL OR ENGINEERED CUTS SHALL CONFORM TO ACI 302.1R "GUIDE FOR TOP, BOT.,(n MID) - HAUNCH SLOPEJI 1 LHAUNCH SLOPE J = I- O° •b° FILL TO FIRM BEARING CONCRETE FLOOR AND SLAB CONS7RUC77ON". �` LI 2 2 -III =� #5CONT IIII=1 �II o0 I=I III III - fT #3 77ES @ 18" O.C. (TYP.) (�-) - - TYPICAL CONCRETE SLAB DETAIL TYPICAL SLAB CONTROL JOINT DETAIL -Y 1'-6" ,- TYPICAL CONCRETE SLAB ON GRADE DETAILS SECTION SECTION Z NO SCALE SCALE: 1/2"=V-0" S101 SCALE: 1/2"=1'-0" S101 1. GENERAL /L FOUNDATIONS GENERAL NOTES ///, CONCRETE KV 02.12.07 ISSUE FOR PERMIT - KV 02.09.07 ISSUE FORBID No B Dete Description 1. ALL WORK SHALL CONFORM TO THE CONNEC77CUT STATE BUILDING CODE AND ITS APPLICABLE 1. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING 'DIG SAFE" AS WELL 1. ALL CONCRETE WORK SHALL CONFORM TO ACI 318 AND 301 REQUIREMENTS THIS SHALL REFERENCED STANDARDS AS ALL APPROPRIATE AGENCIES AND MUNICIPAL177ES TO AVOID DAMAGE TO UNDERGROUND INCLUDE PROPORT70NING OF CONCRETE MIX, CONCRETE' TESTING, PLACEMENT OF CONCRETE; L.L. Bean U77LITIES PRIOR TO THE START OF ANY SITE WORK. AND CURING PROCEDURES 2. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AS THEY RELATE TO NEW CONSTRUCTION. REPORT TO THE 2. BOTTOMS OF ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 4'-0" BELOW FINISH GRADE. 2. CONCRETE SHALL HAVE THE FOLLOWING 28 DAY COMPRESSIVE STRENGTH. 4000 PSI ARCHITECT/ENGINEER ALL OBSERVATIONS AND ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 3. FOOTINGS SHALL BE STEPPED AT A MAXIMUM SLOPE OF 2 HORIZONTAL TO 1 VER77CAL, 3. PROVIDE TOTAL AIR ENTRAINMENT OF 69 (t) FOR ALL CONCRETE EXPOSED TO WEATHER. UNLESS NOTED OTHERWISE (SEE TYPICAL DETAILS). 3. IT lS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO PROVIDE FOR A SAFE AND 4. MAXIMUM WATER/CEMENT RAT70 FOR 4000 PSI CONCRETE - WIC = 0.45. PROVIDE A EFFICIENT METHOD OF SHORING AND/OR BRACING THE STRUCTURE DURING ALL 4. REMOVE ALL TOPSOIL, EXISTING FILLS, ORGANIC MATERIALS, AND FROST DISTURBED SOILS HIGH-RANGE WATER REDUCING ADMIXTURE lF REQUIRED TO INCREASE WORKABILITY OF THE CONSTRUC7ON PHASES. SUBMIT AN OUTLINE OF PROPOSED PROCEDURE TO THE PRIOR TO PLACING NEW FOOTINGS. CONCRETE. ARCHI7ECT/ENGINEER BEFORE CONSTRUCTION COMMENCES. 5. ALL BOTTOMS OF F0077NGS SHALL BEAR ON VIRGIN SOIL WITH A MINIMUM BEARING CAPACITY 5. ALL REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A615 AND HAVE THE 4. ALL WORK SHALL BE CON77N000SLY MONITORED AND INSPECTED BY AN INDEPENDENT OF 4000 PSF (TO BE VERIFIED BY A P.E. DURING CONSTRUCTION), OR SHALL BEAR ON FOLLOWING MINIMUM YIELD STRENGTH (UNLESS NOTED 07HERWISE): TESTING AGENCY. SUBMIT ALL TEST AND INSPECTION REPORTS TO A/E FOR REVIEW. ENGINEERED FILL. THE ENGINEERED FILL SHALL BE COMPACTED IN 8" LOOSE LAYERS TO 957 a. MAIN REINFORCING STEEL ...................................................... 60 KSI OF THE SPECIFIED MAXIMUM DRY DENSITY AS ESTABLISHED BY ASTM D-1557-78, METHOD D. b. TIES & STIRRUPS ................................................................... 40 KSl 5. THE TRADE CONTRACTORS SHALL SUBMIT SHOP AND ERECTION DRAWINGS (COLLECTIVELY THE COMPAC77ON SHALL BE DETERMINED BY ASTM DESIGNA77ON D1556-82, D2167-66, KNOW HEREIN AS "SHOP DRAWINGS) FOR REVIEW PRIOR TO PROCEEDING WITH FABRICATION D2922-81, OR OTHER APPROVED NUCLEAR DENSITY TESTING DEVICE. 6. ALL REINFORCING STEEL TO BE WELDED OR DESIGNATED AS "WELDABLE" SHALL CONFORM TO - AND/OR CONSTRUCTION. BOTH ASTM A615 (BILLET-STEEL) AND ASTM A706 (LOW-ALLOY S7FEL) WITH A MINIMUM a. THE SHOP DRAWINGS SHALL BE PREPARED IN ACCORDANCE WITH THE LATEST ED177ON 6. ENGINEERED FILL UNDER SLABS AND FOOTINGS SHALL CONSIST OF GRANULAR SOIL FREE TO YIELD STRENGTH OF 60 KSI. THE WELDING OF REINFORCING BARS SHALL CONFORM TO THE OF THE RESPECTIVE TRADES' CODES OF STANDARD PRACTICE. ALL SHOP DRAWINGS ORGANIC MATTER AND CONFORMING TO THE FOLLOWING LIMITAT70NS ON GRADATION: ANSI/AWS D1.4 WELDING CODE. SHALL BE FULLY DEVELOPED BY THE TRADE CONTRACTORS OR BY AGENTS OF THE a. MAXIMUM SIZE OF PARTICLES ................................................ 3 INCHES CONTRACTORS CADD FILES, PHOTOCOPIES, OR 07HER REPRODUCTIONS OF THE b. RETAINED ON '3/4" SIEVE ......................................................... 309 MAXIMUM 7. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WI7H ASTM A185. CON TRACT DRAWINGS IN WHOLE OR IN PAR T SHALL NOT BE USED BY THE TRADE c. PASSING NO. 100 SIEVE ......................................................... 459 MAXIMUM CONTRACTORS OR THEIR AGENTS FOR THE PREPARA77ON AND DEVELOPMENT OF SHOP d. PASSING NO. 200 SIEVE ........................................................ 89 MAXIMUM 8. UNLESS NOTED 07HERWISE, PROVIDE THE FOLLOWING MINIMUM REINFORCING COVER: DRAWINGS WI THOU T THE EXPRESSED WRITTEN CONSENT OF ODEH ENGINEERS, INC. a. FOOTTNGS ................................................................................ 3 INCHES The Shops at Evergreen Walk b. ELECTRONIC SUBMISSIONS OF SHOP DRAWINGS WILL NOT BE ALLOWED. PRINTED (HARD) 7. FOR PENETRA77ONS THROUGH CONCRETE FOUNDA77ON WALLS EXCEEDING 8"0, REINFORCE WALL b. SLABS ON GRADE (WWF) ....................................................... SEE TYPICAL DETAILS 75 Tamarack Ave COPIES OF SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW. AROUND PERIMETER WITH (4)-#5 BARS, EACH FACE IN A DIAGONAL PATTERN EXTENDING BUildin C, SUite 75 2'-6" BEYOND OPENING. COORDINATE ALL OPENING LOCA77ONS WITH ARCHI7ECT. 9. REINFORCING LAP SPLICES SHALL BE IN ACCORDANCE WITH ACI-318-02 FOR TENSION LAP g SPLICES, CLASS B, UNLESS NOTED OTHERWISE. HORIZONTAL REINFORCING IN PERIMETER South Windsor, CT 06074 8. SUBMIT REINFORCING STEEL SHOP DRAWINGS FOR REVIEW (SEE SECTION "L GENERAL').. WALLS SHALL BE LAPPED 24" MINIMUM. 10. PROVIDE CORNER BARS AT ALL WALL CORNERS & INTERSECTIONS MATCHING HORIZONTAL TYPICAL EXTERIOR REINFORCEMENT WITH 2'-6" MINIMUM LAPS. SLAB ON GRADE 11. PLACE ALL SLABS PER ACI 301 AND ACI 302.1r96 SPECIFICATIONS. UNLESS NOTED DETAILS & GENERAL OTHERMSE, PROVIDE A MIINIESS FU 2FLOOR FLA7NESS Ff=25, AND, AT SLABS ON GRADE, AMINIMU 5. NOTES 12. PROVIDE SAWCUT JOINTS IN ALL SLABS USING AN EARLY-ENTRY SAW WITHIN 4 HOURS OF Checked By: DJO PLACEMENT. PROVIDE SAWCUTS @ 5'-0" O.C. MAX., UNLESS NOTED OTHERWISE. Job No: 06125.00 13. SUBMIT SHOP DRAWINGS FOR REVIEW (SEE SEC77ON "L GENERAL"). S101 i FOR MECHANICAL y 4 1 WORK AT LOWER M102 LEVEL GENERAL NEW NOTES: T r r 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED E WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, m _ _ _ _ E40CD _ G SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY m5 NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION1201 6 DOCUMENTS. NOTIFY ARCHITECT, ENGINEER AND/OR OWNER OF CONFLICTS OR w 12x12 DISCREPANCIES PRIOR TO SUBMISSION OF BID. rn 0 ' a 1 SD-1 1 MZOi1 I 2. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES a 18x12 j f 380 12x12 I ' TO ENSURE A NEAT AND ORDERLY INSTALLATION. COORDINATE INSTALLATION OF 0 50" FLUE UP ! SD-1 I I a J 1 x1 13 1 2 5 3 2 SD-1 DUCTWORK AND PIPING TO AVOID CONFLICTS WITH ELECTRICAL PANELS, LIGHTING O THROUGH ROQF. 500 13 200 I 1 --_- 1�1201 380 60 EXH{�UST FIXTURES, ETC. ( l v - I_- p-1 M201 - 1 - - VENT Up 1 14x14 14x14 14x14 �� t380 THRU f� OF 3. AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW SD-2 SD-2 SD-2 I- - INSTALLATION DURING WORK. REPAIR DAMAGE CAUSED DURING CONSTRUCTION AT 6x1 500 500 t2 500 ��` r�1 NO EXTRA COST TO THE OWNER. '���'�. � t1�201 `.` 36x16 � ��� OU 13 � ` 4. ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE L--1J STOCK -- — -- I-- -- --- LJ - PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. RTU ROOM 1 1 g 1 RTU 6 4 EF 1 5. NEW MECHANICAL EQUIPMENT, DUCTWORK AND PIPING ARE SHOWN AT \ 201 2 I APPROXIMATE LOCATIONS. FIELD MEASURE FINAL DUCTWORK AND PIPING 13 LOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT c THE DUCTWORK AND PIPING WITHIN THE AVAILABLE SPACE. VERIFY THAT FINAL 13 EQUIPMENT LOCATIONS MEET MANUFACTURER'S RECOMMENDATIONS REGARDING 2 v n E 7 SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. S .0 o No o N ( 14 6. REFER TO ARCHITECTURAL DRAWINGS FOR RELATED CONSTRUCTION DETAILS AS 5 o d N v _ 14 _ _ _ _ _ _ _ _ _ _ — _ — — — _ 8 _ q APPLICABLE TO THE HVAC SYSTEM. VERIFY CHASES AND PENETRATIONS SHOWN ON 12x12 —H 18x12 -0 ARCHITECTURAL DRAWINGS THAT ARE INTENDED FOR DUCTWORK AND PIPING MEET 2 - - - - - - - - - - - - I 201 18x12 18x12 18x12 18x12 - T SD-1 SD-1 SD-1 SD-1 SD-1 SD-1 ( -+ REQUIREMENTS. ;E 2 B c p Y - 1 270 430 430 430 430 430 2 v o x 1 �� 1 1 _ 7. COORDINATE LOCATION OF ROOF MOUNTED HVAC EQUIPMENT AND ROOF - '^ m F u' " 1 220 220 220 SD O1 PENETRATIONS WITH THE LANDLORD EXISITNG LOCATIONS. CONTACT ARCHITECT IF ❑ �� 18x12 } 18x12 18x12 18x12 18x12 18x12 ( EXISTING PENETRATIONS ARE NOT AS SHOWN. SD-1 I SD-1 SD-1 SD-1 � 11 1 SD-1 SD-0 8. INSTALL DUCTWORK AND PIPING PARALLEL TO BUILDING COLUMN LINES UNLESS 430 430 ( 430 430 430 430 i M201 OTHERWISE SHOWN OR NOTED. EXISTING �� 1 1 s 1 1 9. OVERHEAD HANGERS AND SUPPORTS FOR EQUIPMENT, DUCTWORK AND PIPING SHALL ELECo CLOSET , 1 ( - n 1 - - - �- BE FASTENED TO TOP CORD OF BUILDING JOISTS OR BEAMS. DO NOT ATTACH 1 / 1 RTU 6 1 1 , HANGERS AND SUPPORTS TO THE ABOVE ROOF. 3 -6 RTU 1 2 3 ( 10. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH LOCATION OF EQUIPMENT 1 EF 4 .` r—� 5 M201 M2011 201 ACCESS PANELS/DOORS TO ENABLE SERVICE OF EQUIPMENT AND/OR FILTER RM �'�, �� 36x24 � � 3 201 ��` 36x24 v v � REPLACEMENT. / II 36x24 ICI �I (TYP.)(TYP.I(TYP.) s 18x12 1— — 18x12 11. SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH f _ L---L`�J 18x12 18x12 L-- — —� 18x12 THE CONTRACT SPECIFICATIONS. FIREPROOF PENETRATIONS THROUGH FIRE RATED 1SD,12 aSD-SD-1 I 5001 0 7 5001 a + RTU 6 5 -1 IN S 00 0 5001 I COMPONENTS IN ACCORDANCE WITH U.L. REQUIREMENTS. 500 500 200 240 M 200 200 4 200 200 240 200 �� 12. COORDINATE THE EXACT MOUNTING SIZE AND FRAME TYPE OF DIFFUSERS, REGISTERS AND GRILLES WITH THE SUPPLIER TO MEET THE CEILING, WALL AND DUCT [�� _ _ _ _ �_ _ _ _ _ _ _ _ _ _ I _ INSTALLATION REQUIREMENTS. - f_ — - — - -- - — - - - - - - �I - - _-1sx12 -- - -li - - - 18x12 -�T - /� - - - - T-- - - - 3 } 18x12 SD-1 11 SD-1 SD 11 I 5 / �/ 1 17J/ 18x12 ( ��� 13. ADJUST LOCATION OF CEILING DIFFUSERS, REGISTERS AND GRILLES AS REQUIRED TO 5001 500 M201 / 500 500 50 5001 ACCOMMODATE FINAL CEILING GRID AND LIGHTING LOCATIONS. (TYP.) (TYP.) (TYP.) 14. LOCATE AND SET THERMOSTATS FOR WIRING IN CONDUIT UNDER DIVISION 16. M201 14 VERIFY EXACT LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. INSTALL 1 FOR MECHANICAL M201 DEVICES 48" AFF TO MEET ADA REQUIREMENTS UNLESS NOTED OTHERWISE ON M102 WORK AT LOWER PLANS. PROVIDE INSULATED BACKING FOR THERMOSTATS MOUNTED ON EXTERIOR -� -� �- \\ ''>;. LEVEL -#- -f- BUILDING WALLS. 18x12 1802 18x12 18x12 V\ SD-1 SD-1 _ _ I \ I 18x12 18x12 15. PROVIDE A MANUAL BALANCING DAMPER IN EACH BRANCH DUCT TAKEOFF FROM •' ,'R'''+ SD-1I SD-1 MAIN SUPPLY, RETURN, OUTDOOR AND EXHAUST AIR DUCTS. 500 500 5001 500 \ ` ' '�•� 500 500 7 I I 've 11 16. PROVIDE A PREFABRICATED 45 DEGREE, HIGH EFFICIENCY, RECTANGULAR/ROUND BRANCH DUCT TAKEOFF FITTING WITH MANUAL BALANCING DAMPER AND LOCKING 1 t 1 1 �`�.,' ;" - QUADRANT FOR BRANCH DUCT CONNECTIONS AND TAKE-OFFS TO INDIVIDUAL M-LO 1 (�1) I �� NL2�0 1 DIFFUSERS, REGISTERS AND GRILLES. 17. BRANCH DUCTWORK TO AIR OUTLETS SHALL BE SAME SIZE AS OUTLET NECK SIZE UNLESS OTHERWISE NOTED. SALES ` 18. RIGID DUCTWORK INSULATION: PROVIDE 2" THICK, 3/4 LB DENSITY INSULATION WRAP s 18x12 18x12 FLoo ON RIGID ROUND, CONCEALED, SUPPLY AIR DUCTS. FURNISH AND INSTALL 1-1/2" oN SD-1 ISD-1 I 18x12I 18x12 THICK, 3 LB DENSITY INTERNAL DUCT LINER ON RECTANGULAR SUPPLY AND RETURN 500 500 } SD-11 @ SD-1 AIR DUCTS. DUCT SIZES ON MECHANICAL PLANS INDICATE CLEAR INSIDE AIRFLOW 500 L o 00 DIMENSIONS, INCREASE SHEET METAL SIZES ACCORDINGLY. EXPOSED ROUND T DUCTWORK IS NOT INSULATED. 18x12 1802 ' SD-1 SD-1 19. PROVIDE THERMAFLEX TYPE G-KM, FLEXMASTER TYPE 8, OR APPROVED EQUAL 500 `\I 500 I FLEXIBLE DUCTWORK. FLEXIBLE DUCTWORK SHALL BE LISTED UNDER UL 181 AS (TYP.) CLASS 1 AIR DUCT AND BE PROVIDED WITH INTEGRAL 1-1/2" THICK, 3/4 LB DENSITY (TYP ) 14 FIBERGLASS INSULATION. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5'-0" IN LENGTH 300 ( 14 18x12 18x12 I 18x12 M201 18x12 AND SHALL BE INSTALLED AND SUPPORTED TO AVOID SHARP BENDS AND SAGGING. M201 SD-1 SD-1 SD-1 SD-1 500 500 _ _ _ _ _ 500 500 _ _ 20. PROVIDE EQUIPMENT VENTS AND FLUES PER EQUIPMENT MANUFACTURERS T� [� - I� LJ � ( 2 RECOMMENDATIONS AND EQUIPMENT SPECIFICATIONS. KEEP PENETRATIONS N THROUGH ROOF A MINIMUM OF 10'-0" FROM HVAC EQUIPMENT FRESH AIR INLETS AND 180 220 220 180 180 220 220 180 2'-0" FROM ROOF PARAPETS. 12x10 J 12x101 120 0 112x10 SD-1 I SD-1 I SD-1f i SD-1 21. PROVIDE A NEW SET OF AIR FILTERS IN UNITS PRIOR TO TESTING, ADJUSTING AND 375 375 12x10 375 375 BALANCING. AND BEFORE TURNING SYSTEM(S) OVER TO OWNER. -•!- -F- SD-1 e I 6 375 ( o 22. INDOOR AIR QUALITY MEASURES: PROTECT INSIDE OF (INSTALLED AND DELIVERED) 1 18x12 18x12 M +_ } DUCTWORK AND HVAC UNITS FROM EXPOSURE TO DUST, DIRT, PAINT AND SD-1 SD-1 12x 12x10 1 12x10 MOISTURE. REPLACE INSULATION THAT HAS GOTTEN WET AT ANY TIME DURING 500 500 1 SD-1 SD-1 1 i8x12 18x12 12x10 � , SD_1 SD-1 ! CONSTRUCTION, DRYING THE INSULATION IS NOT ACCEPTABLE. SEAL ANY TEARS OR _ SD-1 SD-1 -J 375 JOINTS OF INTERNAL FIBERGLASS INSULATION. REMOVE DEBRIS FROM -J 375 375 -J 5001 500 375 I I RTU 6 3�5 CEILING/RETURN AIR PLENUM INCLUDING DUST. AN INDEPENDENT, PROFESSIONAL RTU 6 I I RTU 6 I I �/ 11 p DUCT CLEANING COMPANY SHALL VACUUM CLEAN ANY DUCTWORK CONNECTED TO 7 1 1 M201 HVAC UNITS THAT WERE OPERATED DURING THE CONSTRUCTION PERIOD AFTER NEW ' I I 11 L� J I FILTERS ARE INSTALLED AND PRIOR TO TURNING SYSTEM OVER TO THE OWNER. M201 4 J C J 1 4 23. PAINT EXPOSED METAL SURFACES IN ACCORDANCE WITH SPECIFICATIONS, COLOR AS 1 M ` M ` I- ( SELECTED BY ARCHITECT. 12x10 12X10 12x10 1 /� SO 1 SD-1 8 SD-1 37� + r M201 375 4�20P-til � KEY NOTES: 218x12 (NP ) 18�12 18x12-\\� \\ i 3 12x10 x10 1 PROVIDE 1/2" ALUMINUM MESH SCREEN OVER RETURN DUCT OPENING. RL SD 1 SD-1 % SD-1 SD-1 SD-1 1 500 500 5 p 50� 375 375 375 -1 O2 ROUTE THE REFRIGERANT PIPING DOWN TO IU-1 SERVING SERVER ROOM. �� 1 .I SIZE REFRIGERANT PIPING AS RECOMMENDED BY MANUFACTURER. ROUTE REFRIGERANT PIPING ON ROOF TO CONDENSING UNIT. ROUTE 16"0 SUPPLY DUCT DOWN. REFER TO M102 FOR CONTINUATION. ROUTE 12 0 EXHAUST DUCT DOWN. REFER TO M102 FOR CONTINUATION. - - - - - - - - - - �_ _ 1—J _ No B Date Description FT - _ __ - - _ - _ _ _ _ - - - - - - _ - _ _ _ � © PROVIDE CONDENSATE DRAIN PER DETAIL 3 ON SHEET M201. - - - ' �� O7 ROUTE 12"X12" EXHAUST DUCT DOWN. REFER TO M102 FOR CONTINUATION. L.L. Bean I I ® ROUTE YO COMBUSTION AND VENT UP THROUGH ROOF. REFER TO PLUMBING DRAWINGS. CFI r 7x 11711 IID [PTI 01 h I i I I I I I I I I \.ouo��lmnm,1I!Z iq �F � E �� (C.7 1C.2 C B �� yQ St UPPER LEVEL 3 MECHANICAL FLOOR PLANOM U 016100 1 SCALE: 1/8"=1'-0" L' The Shops at Evergreen Walk South Windsor, CT a n Mechanical Floor n a Plan, Upper Level 0 a 3 v 0 Checked By: MS m a Job No: 06125.00 N O L U m O O O F U N ENGINEER OF RECORD: m 10 1 3 Duane S . Henderson 0 8325 LENEXA DRIVE SUITE 400 LENEXA, K8. 66214-1695 y TEL: 913-307-5300 FAX: 913-307-5400 m WEB: WWW.HENDERSONENGINEERS.COM m 0650001687 0 0 o m 0 m m m J J I U C N N N Q GENERAL NEW NOTES: a REFER TO M1.0 E m m (TYP.) 60 1 1 ioi\ 4 i 1 00 - - - - __ __ - - - - - - - - - - - — - — - — - — - — - - -rLi - - - - - - - - - sa - - - - - - - - - - - - - - -� - - - 5 GENERAL NEW NOTES: O SD-3 80 - �-' - - 150 1 120 160 A�F - O ROUTE THE REFRIGERANT PIPE DOWN TO IU-1 MOUNTED ABOVE DOOR. T OFFICE SAFE TEV a RESTROOM I SIZE REFRIGERANT PIPE AS RECOMMENDED BY MANUFACTURER. t /I RTU-2 SUPPORT 80 80 COM 80 80 N "� EF OFFICE. 2 200 SD-3 u-1 T SD-3 SD-3 _ 1 O2 UNDER CUT THE DOOR 1 REFER TO ARCHITECTURAL DRAWINGS. 50" FLUE UPI MGR. �- 110 225 F 225 \ / 3 ROUTE THE 12"X12" EXHAUST DUCT DOWN. REFER TO M101 FOR CONTINUATION. CO2-RTU-2 2 LOU GE /' 1 D O &- STA ' a � EVER EGRESS �I�COR DOR O4 ROUTE 16"0 SUPPLY DUCT UP. REFER TO M101 FOR CONTINUATIONS. I GH 1 8 TG-1 1 11 IU - -. _ e GU-1 1 I (TYp -2) 1 2xI12 O5 ROUTE 12"0 EXHAUST DUCT UP. REFER TO M101 FOR CONTINUATIONS. "o H CO2-RTU-1 EACHONE OSIDE E251 ,! BO © ROUTE 12"0 EXHAUST DUCT UNDER SLAB. .� C T RTU-1 MEWS OOM D- o u --_----- OF WALL _._...f ...._ ° o v N ^ w STOCK I N 100� O7 MOUNT TWO (2) EXHAUST DUCT VERTICALLY ALONG 12"4 EXHAUST DUCT. y „ o � o , ROOMI \ L! 80 MOUNT THE EXHAUST GRILLE 12" A.F.F. AND 18' BELOW CEILING. 6x SD- U I I \ (r11 EG 1 150 ® TRANSFER GRILLE MOUNTED AS HIGH AS POSSIBLE ABOVE DOOR. cot-RTU-4 "' 100 ___ / ( C O9 ROUTE 3"0 COMBUSTION AND VENT UP THROUGH ROOF. REFER TO PLUMBING w RETURNS / T / �� DTI ITyh -11 1 - 9 DRAWINGS. RTU OM I—I I80 I I O 2x12 SD-4 ( 1) 10 ROUTE 6"0 EXHAUST DUCT UP. REFER TO M101 FOR CONTINUATION. 47�-- _ _�11 �11 - - 2 1 150 -f - — 11 REFER TO PLUMBING DRAWINGS FOR ROUTING OF CONDENSATE PIPING. OMEN OOM EIMER 60 O l�` SD-3 1 70, 1 P EXISTING 1 L. ELEC I M0N0GRA MING SD!4 1D CLOSET / I ROOM 150 (v1) /. TYP. I I I I I CO2-RTU-8 RTU-3 C T RTU-5 CO2-RTU-3 C T 6 I - - - - - - - - - - - - - - - - � - - - - - - - - - - - - +� - - - - - - - - - -lip - - - - - - - - - -� - - - - 5 +EG 2 (TYP.-2) I / BIKE SHOP I I I SALES FLOO I I I I I I I I I I I I I I I I CO2- U 8 CO2-RTU-7 - - - - - �_ - - - - - - - - - - - LJ- - - - - - - - — - — - - T - - - - - - - - - - Ed- - - - - - - - - - - — - —M— - - - - - - - -�� RTU-8 RTU17 I I I I I I I I I I I I I i I I I I I 1 I I I I I I I I I I I I I I I I I I I 1 CO2-RTU-6 �C T RTU-6 I I I MEN'S FITTING RM WOMEN'S CASH WRAP \ UH UH FITTING RM 1 , 2 '7 3 No By Date Description L.L. Bean - — 1 1 - - - - - - - - - - — - - - - - - - - - - - - L-- _- . 11 - — - - - - - - - - - - - - t r -,. CONNC i I pODUppu�nn8lhlgh 4_ No.16100 €A5 o O hih . p O` cJ �� () (Cj.2 C .� �1,11= � The Shops at Evergreen Walk f South Windsor, CT a m m LOWER LEVEL Mechanical Floor a MECHANICAL FLOOR PLAN Plan, Lower Level SCALE: 1/18"=1 '-0" N m 3 N a Checked By: MS m m g Job No: 06125.00 0 N m a L U m O O O F U ENGINEER OF RECORD: m 10 200" 3 Duane S . Henderson a 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 N TEL: 913-307-5300 FAX: 913-307-5400 m WEB: WWW.HENDERSONENGINEERS.COM fO 0650001687 0 0 o m m 0 'c m m m J MECHANICAL LEGEND U AFF ABOVE FINISHED FLOOR c a y CFM CUBIC FEET PER MINUTE m DDC DIRECT DIGITAL CONTROL EXHAUST FAN WITH U I O N EA EXHAUST AIR I BIRDSCREEN Q I GPM GALLONS PER MINUTE ROOFTOP UNIT T IN. WC INCHES OF WATER COLUMN THREADED TEE, WITH EXTENDED o MBH 1000 BTU PER HOUR NIPPLE AND CAP `m GAS OR CD PIPE, 00 MC MECHANICAL CONTRACTOR SECURE EXHAUST FAN TO ROOF / DISCHARGE AWAY FROM SEE FLOOR PLANS o NC NOISE CRITERIA EXTEND DUCTWORK ROOF CURB CURB / SERVICE AREAS OF UNIT OR 1/4"x1-1/2" CADMIUM a OA OUTSIDE AIR OVER TOP OF CURB, WHERE SHOWN ON PLANS PLATED LAG SCREWS GALVANIZED STEEL CLAMP. ROOFTOP ROOF CURB t SECURE DUCTWORK DO NOT CLAMP PIPE TIGHT. HVAC UNIT BY LANDLORD RA RETURN AIR ® PREFABRICATED INSULATED m 18x18x3 TO CURB NAILER " " 16" ROOF/ SA SUPPLY AIR CURB WITH TREATED WOOD WALKWAY MATERIAL + TWO 4" x 4" x 12" PLASTIC e o ` 0 SECURE CURB TO NAILER. FOR BASE SHEET SUPPORT BLOCKS OR CCA 1 U W/ WITH UNLESS NOTED OTHERWISE ROOF WITH SCREWS, Uj N USE A PRODUCT ROT-PROOF TREATED TIMBERS. i Q PINS, OR BOLTS ROOF INSULATION ¢ COMPATIBLE WITH s TOE NAIL BLOCKS TOGETHER _ W/0 WITHOUT o ROOF MEMBRANE. t TO PROVIDE MINIMUM 7 INCH EXISTING PIPING TO BE REMOVED 0 N _ INSTALLATION N TALL T CLEARANCE UNDER PIPES. ION ----- ---- WITH ROOFING EXISTING PIPING SHOWN LIGHT LINE WEIGHT TO REMAIN 1" MINIMUM CONTRACTOR. RETURN ` SUPPLY NEW PIPING SHOWN HEAVY LINE WEIGHT ` AIR DUCT PROVIDE MULTIPLE AIR DUCT ` S OR — HWS — HEATING HOT WATER SUPPLY ROOF TRIMBAS HEETIMBER ` CEILING AS REQUIRED TO ---- HWR ---- HEATING HOT WATER RETURN ROOF DECK REFER TO ROOF INSULATION CANVAS CONNECTION FASTEN ANGLE IRON BLOWTHRU: ACCOMODATE — CWS — CHILLED WATER SUPPLY SECURELY TO DUCT ARCHITECTURAL DRAWINGS A = GREATER OF 4" OR 1 2" PLUS ROOFTOP UNIT DIRECTION OF GRAIN. --" VARIATIONS IN (TYPICAL) / ROOF DECK ROOF ELEVATION. 11 ---- UMM4 2 CWR ---- CHILLED WATER RETURN AND ROOF STRUCTURE COUNTER BALANCED BACKDRAFT TOTAL PRESSURE IN INCHES-WATER COLUMN RL REFRIGERANT LIQUID (UNLESS NOTED OTHERWISE) NOTES '9 u o N o DAMPER, SECURE TO DUCT FROM DRAWTHRU: .9 •� o u RD REFRIGERANT DISCHARGE (HOT GAS) ABOVE TO ALLOW SERVICE OR B = 3" LOCATE SUPPORTS AT 4' SPACING FOR PLASTIC PIPE, & AT FOLLOWING I. LANDLORD TO PROVIDE OPENING THROUGH ROOF AND ROOF DECK -o 0 u N o v SPACING FOR METAL PIPE: 5"=16' 4"=14' 3"=12' 2-1 2"=11' 2"=10' INSULATION NO LARGER THAN REQUIRED TO ALLOW DUCTS TO PASS b o � A RS REFRIGERANT SUCTION REMOVAL OF DAMPER FROM / THROUGH. REFER TO PLANS FOR DUCT SIZES. TRANSITION AS REQUIRED v ^ �1 rn ROOF NOTES: 1-1/2"=9' 1-1/4"=8' 1"=7' 3/4"=6'. PLACE A SUPPORT AS CLOSE AS POSSIBLE IN ROOF CURB TO RTU SUPPLY AND RETURN OPENINGS Y TO EACH ELBOW AND TEE. PLACE BASE SHEETS ON ROOFING BEFORE . PRESSURE GAUGE 1. 1"0 MINIMUM PIPE SIZE OR SIZE PER DRAIN TAP IN ROOFTOP 8 quq v p EXHAUST DUCT UP THROUGH UNIT. GRAVEL IF ANY. SET BLOCKS FREE ON BASE SHEETS. STACK BLOCKS 2. LANDLORD TO PROVIDE SLOPED ROOF CURB TO INSTALL ROOFTOP UNIT � snW, ° o ROOF. SEE PLANS FOR AND NAIL THEM TOGETHER WHERE REQUIRED TO ELEVATE PIPING. LEVEL TO ENSURE PROPER DRAINAGE. COORDINATE ROOF SLOPE WITH b o x THERMOMETER SIZE AND LOCATION. INSTALL PIPE TO ALLOW FOR EXPANSION AND CONTRACTION. ARCHITECTURAL. FLASH AND COUNTER FLASH ROOF PENETRATIONS, ETC. TO UNION ENSURE WEATHER TIGHT INSTALLATION. H FLANGE CONNECTION DOWNBLAST EXHAUST 10 ELBOW UP 4 FAN DETAIL ) CONDENSATE DRAIN TRAP 2 SUPPORT OF PIPE ON ROOF 1 ROOFTOP UNIT WITH DUCTWORK DETAIL �� ELBOW DOWN NO SCALE NO SCALE NO SCALE NO SCALE 40 TEE UP TEE DOWN TWO-WAY CONTROL VALVE THREE-WAY CONTROL VALVE SHUTOFF VALVE ROOF ROOF CHECK VALVE PARALLEL TO STRUCTURE BALANCING VALVE WITH PRESSURE PORTS ANGLE OR UNISTRUT / JOIST PARALLEL TO STRUCTURE / � �] TRIPLE DUTY VALVE WITH PRESSURE PORTS 6" HANGER STRAP 6" 6" 1 1 JOIST 6" fyl STRAINER SEE NOTE 1. EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED SEAL CONNECTION �f ANGLE OR UNISTRUT WEATHER TIGHT EXISTING DUCTWORK OR EQUIPMENT SHOWN LIGHT OPTIONAL ROUTING IN LINE WEIGHT TO REMAIN SHEET METAL CONCEALED AREAS STAINLESS STEEL CLAMP INSULATION - PROVIDE NEW DUCTWORK OR EQUIPMENT SHOWN HEAVY 1" MIN SCREWS SEE LOAD RATED ALUMINUM JACKET OVER FASTENERS CONE FLASHING INSULATION EXPOSED PIPE HEAVY LINE WEIGHT NOTE 2. (TYP) PREFABRICATED TO WEATHER (MAX. 36"0) INSULATED CURB OVERSIZED BRANCH DUCT WITH 45' RECTANGLE-ROUND BRANCH 60 MAX WITH TREATED SLOPE GALVANIZED COVER SEAL CONNECTION FITTING AND MANUAL VOLUME DAMPER I WEATHERTIGHT WOOD NAILER ELBOW WITH TURNING VANES ROUND SUPPLY STAINLESS STEEL ROOF AIR DUCT PREFABRICATED CLAMP INSULATED CURB WITH L COLLAR 26 GAUGE GALVANIZED \ ---- TWO PIECE GALV. TREATED WOOD NAILER MANUAL VOLUME DAMPER _PERPENDICULAR TO STRUCTURE D /� \ _ COUNTER FLASHING � STEEL CURB COVER OR \ \ ` INSULATION AND CURB. AS APPROVED BY CURB \ %\\ ROOF 1\ MANUFACTURER RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP \ // \ PERPENDICULAR TO STRUCTURE \\ \ // I GALVANIZED COUNTER TWO PIECE 26 GA. RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN BOTTOM OF STRUCTURE \ LOADS MUST BE INSULATION FLASHING AND CURB SUPPLY AIR DUCT UP RECTANGULAR DUCT \\\ BOTTOM OF THREADED \\/� HUNG WITHIN 6" SUPPLY AIR DUCT DOWN STRUCTURE ROD (TYP) 1 OF PANEL POINTS ------- //�/� PROVIDE 2' CLEAR OPENING ROOF STRUCTURE I — Cfld TWIST STRAP TO ALLOW FOR MOVEMENT. SEE ARCHITECTURAL j LOADS MUST BE 16 GA. GALV. STEEL AND STRUCTURAL EQUIPMENT WITH FLEXIBLE DUCT CONNECTION LOAD RATED � HUNG WITHIN 6" BAND 2" WIDE PLANS FOR DETAILS OF PANEL POINTS ( ) FASTENERS PROVIDE 1" CLEAR ROOF DECK ANGLE OR UNISTRUT (MAX. 24"0) OPENING AROUND PIPE Qom® SIZE, TYPE, CFM OF DIFFUSER, REGISTER OR GRILLE ROUND DUCT TO ALLOW FOR PIPE PROVIDE MSS TYPE 8 NOTE: MOVEMENT 1. USE THREADED ROD FOR ALL DUCTS LARGER THAN 60"0 WIDE. RISER CLAMP FOR 10"0 10"A NOTE: PIPES 6' AND LARGER CSD-1 CSD-1 1. FOR DUCTS LARGER THAN 36"0, USE TWO HANGER RODS, WIRES OR STRAPS 450 450 2 LOOPS METAL SCREWS ENTIRE MAY DUCT.BE OMITTED IF HANGER STRAP IS CONTINUOUS AND TO SUPPORT DUCT FROM EACH SIDE. ROUND AIR DUCT OR PIPE FD FIRE DAMPER (D THERMOSTAT 8 RECTANGULAR DUCT SUPPORT DETAIL (7 )-NO ROUND DUCT SUPPORT DETAIL 6 PENETRATION THROUGH ROOF DETAIL 5 PIPE ROOFPENETRATION DETAILFSDFIRE SMOKE DAMPER TS TEMPERATURE SENSORNO SCALE SCALE NO SCALE NO SCALE SD SMOKE DAMPER VD VOLUME DAMPER O HUMIDISTAT MD MOTORIZED DAMPER NOTE: PROVIDE GREY OR ALUMINIZED DUCT TYPICAL DETAIL REFERENCE TAPE SECURING AND SEALING (TYPICAL) 1 UPPER NUMBER INDICATES DETAIL NUMBER FLEXIBLE DUCT OR EXTERNAL I�/-FASTEN TO STRUCTURE METAL BAND OVER INSULATION INSULATED DUCT M1 LOWER NUMBER INDICATES SHEET NUMBER DUCT INSULATION HIGH EFFICIENCY TAKEOFF EXTERNALLY 45' HIGH EFFICIENCY INSULATED, WITH VOLUME DAMPER AND TAKE-OFF WITH SQUARE DAMPER LOCK WITH EXTENSION CONNECTION POINT OF NEW WORK TO EXISTING TO ROUND FITTING FOIL TAPE AT RT SHEETMETAL DUCT FLEXIBLE DUCT (MAXIMUM INSULATION JOINT _ EQUIPMENT DESIGNATION AND NUMBERJill 1 OF 5'-0" WITH ONE 90' 1= O1 MECHANICAL NOTE DESIGNATION ELBOW) 1" BAND CLAMP SEE NOTE 1. _ m CONNECT TO AIR PRE-INSULATED FLEXIBLE 1 5 DEVICE NECK DUCT AS REQUIRED, SECTION CUT DESIGNATION UNLESS OTHERWISE INSTALL PERMANENTLY FOR FIRE RATED M1 ROUND SUPPLY DUCT ROUND SUPPLY DUCT NOTED FLEX DUCT CEILINGS, PROVIDE IS SAME SIZE AS SEALED AND SUPPORTED FIRE RATED JACKET DIFFUSER NECK TO PREVENT KINKING TO COMPLETELY -� SPLIT DOUBLE SIDED AND SHARP TURNS COVER DIFFUSER TAPE AT 45' ANGLE CONE. SEAL FOIL TO i TO PREVENT LEAKAGE METAL BAND (TYPICAL) CONE WITH FIBER / APPLY BAND OVER DOUBLE REINFORCED FOIL REGISTER (SIZE AS SIDED TAPE TO COMPRESS BALANCING DAMPER WITH CEILING DIFFUSER WITH BACKTAPE SHOWN ON DRAWINGS) AND SEAL FLEX TO OUTSIDE VOLUME DAMPER, FIRE OF COLLAR STAINLESS STEEL QUADRANT LOCK DAMPER OR COMBINATION o0 000� / BAND 1/2" MINIMUM WIDTH) ) (SEE NOTE 3 AND 4) VOLUME/FIRE DAMPER -� AS SCHEDULED NOTES: 1. CUT OPENING IN SHEETMETAL DUCT ACCURATELY. INSTALL 45' LATERAL CEILING No B Date Description 30' `� / 30' TO AVOID VISIBLE OPENINGS AND SECURE FITTING SUITABLY FOR PRESSURE """ CLASS. L.L. Bean INTERGAL VOLUME 2. INSTALL FLEXIBLE DUCT IN AS STRAIGHT A RUN AS POSSIBLE. USE LONG RADIUS DAMPER WITHIN BENDS WHERE POSSIBLE. PULL DUCT TIGHT AT BOTH ENDS AND SECURE WITH THE REGISTER. METAL CLAMPS. NOTES: 1. EXTEND RIGID METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT I 3. PROVIDE EXTENSION RODS TO ACCOMMODATE INSULATION, PULL TO EDGE OF EXCEED 5'-0". PROVIDE RIGID 90' ELBOW WHERE REQUIRED TO KEEP FLEXIBLE INTERGAL VOLUME DUCTWORK AS REQUIRED AND SEAL TO MAINTAIN VAPOR BARRIER. DUCT WITHIN 5'-0" LENGTH LIMITATION. REGISTER (SIZE AS DAMPER WITHIN y SHOWN ON DRAWINGS) THE REGISTER. 4. INSTALL LOCKING QUADRANT TO HANDLE ON BOTTOM OF DUCT FOR EASE OF SERVICE. a 'rOfdNF',,,, oa` ............... 45* LATERAL FLEXIBLE LAY—IN AND SLOT TYPE g,liEly t C . y P�0 ° �a�Fflm G�ery 1 Z REGISTER MOUNTING TO ROUND DUCT DETAIL 1 1 REGISTER MOUNTING TO ROUND DUCT DETAIL 1 O DUCT TAKE OFF DETAIL 9 CEILING DIFFUSER DETAIL _ � NO SCALE NO SCALE NO SCALE NO SCALE _ - ,� No.to700 Q x � a 7 ROUND SUPPLY DUCT t REGISTER (SIZE AS The Shops at Evergreen Walk n SHOWN ON DRAWINGS) I South Windsor, CT SUPPLY AIR DUCT Mechanical Details m _ I AIR FLOW « AIR FLOW o I a I a 3 - v Checked By: MS m INVERTED DUCT COLLAR o 45' ENTRY COLLAR INTERGAL VOLUME Job No: 06125.00 DAMPER WITHIN SUPPLY AIR REGISTER THE REGISTER. WITH INTEGRAL VOLUME 0 DAMPER F U ENGINEER OF RECORD: M201 3 t Duane S . Henderson 5 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 1 4 TYPICAL DUCT MOUNTED REGISTER DETAIL 13 REGISTER MOUNTING TO ROUND DUCT DETAIL TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM s NO SCALE NO SCALE 0650001687 o 0 a m m J HEATING VENTILATING, AND AIR CONDITIONING: U04 y ROOFTOP UNIT SCHEDULE ( NATURAL GAS HEAT) TEMPERATURE CONTROLS o MARK MANUFACTURER MODEL NOMINAL UNIT SUPPLY FAN COOLING COIL HEATING COIL MIN. MCA MOCP V PH DISC. REFR. EER WEIGHT NOTES GENERAL REQUIREMENTS U, �w TONAGE TYPE CFM ESP MIN VFD TH SH EAT LAT MIN. OUTPUT EFF. MIN. NO. O/A TYPE TYPE (LBS) PROVIDE A SYSTEM OF TEMPERATURE CONTROLS INCLUDING THERMOSTATS, t IN BHP Y N) (MBH) (MBH) (DB WB DB WB MBH % STAGES CFM CONTROL PANELS, TIME SWITCHES, OVERRIDE TIMERS, DAMPER MOTORS, AND E RELAYS REQUIRED TO PROVIDE THE DESIRED SEQUENCE OF OPERATION. PROVIDE RTU-1 LENNOX LGA060H 5 SINGLE ZONE 2,000 1 .3 1 .3 N 61 .9 46.4 79.8/66.4 58.2/56.5 100 80 2 500 16 20 480/3 FUSED R-41Oa 12 730 A-N INTEGRATED WIRING DIAGRAMS SHOWING INTERCONNECTIONS BETWEEN FIELD m INSTALLED EQUIPMENT AND PACKAGE WIRING FURNISHED WITH THE HVAC o RTU-2 LENNOX LGA090H 7.5 SINGLE ZONE 3,100 1 .5 2.1 N 89.2 71 .2 78.8/65.8 57.5/56.5 104 80 2 575 24 30 480/3 FUSED R-410a 12.5 1300 A-N EQUIPMENT. N RTU-3 LENNOX 48PGEC14 12.5 SINGLE ZONE 5,000 1 .5 4.2 N 156.9 115.7 79.0/65.9 57.5/55.8 144 80 2 985 32 40 480/3 FUSED R-410a 11 .4 1400 A-N PROVIDE SUPERVISION AND ON-JOB CHECKOUT SERVICE AS REQUIRED TO ENSURE RTU-4 LENNOX 48PGEC14 12.5 SINGLE ZONE 5,000 1 .5 4.2 N 156.9 115.7 79.0/65.9 57.5/55.8 144 80 2 985 32 40 480/3 FUSED R-410a 11 .4 1400 A-N THAT INSTALLATION MEETS REQUIREMENTS OF THE SPECIFICATION. THE SYSTEM a SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FOLLOWING THE ACCEPTANCE RTU-5 LENNOX 48PGEC14 12.5 SINGLE ZONE 5,000 1 .5 4.2 N 156.9 115.7 79.0/65.9 57.5/55.8 144 80 2 985 32 40 480/3 FUSED R-41Oa 11 .4 1400 A-N OF THE SYSTEM BY THE ARCHITECT/ENGINEER. CORRECT DEFECTS OCCURRING a DURING THIS PERIOD AT NO ADDITIONAL COST TO THE OWNER. RTU-6 LENNOX 48PGEC14 12.5 SINGLE ZONE 5,000 1 .5 4.2 N 156.9 115.7 79.0/65.9 57.5/55.8 144 80 2 985 32 40 480/3 FUSED R-410a 11 .4 1400 A-N RTU-7 LENNOX 48PGEC14 12.5 SINGLE ZONE 5,000 1 .5 4.2 N 156.9 115.7 79.0/65.9 57.5/55.8 144 80 2 985 32 40 480/3 FUSED R-410a 11 .4 1400 A-N EQUIPMENT RTU-8 LENNOX 48PGEC14 12.5 SINGLE ZONE 5,000 1 .5 4.2 N 156.9 115.7 79.0/65.9 57.5/55.8 144 80 2 985 32 40 480/3 FUSED R-410a 11 .4 1400 A-N MANUFACTURERS AND MODEL NUMBERS ARE LISTED FOR REFERENCE QUALITY AND FEATURES REQUIRED FOR THE CONTROL DEVICES. PROVIDE CONTROL DEVICES BY BARBER-COLMAN, HONEYWELL, JOHNSON CONTROLS, TRANE OR WHITE RODGERS WITH QUALITY AND FEATURES AS INDICATED. NOTES: LOW VOLTAGE TYPE DAY THERMOSTATS WITH SEPARATE SET POINTS FOR HEATING A. EQUIPMENT SIZED FOR 95 'F AMBIENT TEMPERATURE. AND COOLING SHALL BE HONEYWELL SERIES T8400 OR EQUAL, WITHOUT SUBBASE v, SWITCHES. SEVEN DAY PROGRAMMABLE, OCCUPIED/UNOCCUPIED THERMOSTATS B P. B. PROVIDE MINIMUM EFFICIENCY MERV-8 FILTER. FOR CONTROL OF MULTIPLE STAGES OR MODULATION OF HEATING AND COOLING C. SPECIFIED FAN ESP INCLUDES LOSSES FOR DIRTY FILTERS. SYSTEMS AND FOR CONTROL OF ECONOMIZER SYSTEM SHALL BE HONEYWELL B D. PROVIDE ROOFTOP CURB ADAPTORS TO MATCH ROOFTOP UNIT TO EXISTING CURB. SERIES MODULE. PR THERMOSTAT WITH INTEGRAL SUBBASE AND W7215A ECONOMIZER .1 o No $ E. PROVIDE DRY-BULB ECONOMIZER WITH BAROMETRIC RELIEF DAMPER. THERMO THERMOSTATS. I E HONEYWALL THERMOSTATS STATSAto08 GUARDS FOR PROGRAMMABLE TYPE THERMOSTATS. INSTALL THERMOSTATS AT 48" AFF TO MEET ADA REQUIREMENTS t N p G. PROVIDE WITH TEMPERATURE SENSOR.PROVIDE ACRYLIC, VANDAL-PROOF, LO < S COVER. UNLESS OTHERWISE NOTED ON THE PLANS. b d so H. DIVISION 16 CONTRACTOR TO FURNISH AND INSTALL SMOKE DETECTORS IN SUPPLY AIR DUCT. PROVIDE DAMPER OPERATOR FOR EACH AUTOMATIC DAMPER WITH SUFFICIENT 8 a •� J. DISCONNECT SWITCH FURNISHED BY DIVISION 16 CONTRACTOR. CAPACITY TO OPERATE THE DAMPER UNDER ALL CONDITIONS AND TO GUARANTEE b o TIGHT CLOSE-OFF OF DAMPERS AGAINST SYSTEM PRESSURE ENCOUNTERED. EACH ¢� w w a w 6 K. STARTERS FOR ALL MOTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. OPERATOR SHALL BE PROVIDED WITH SPRING-RETURN FOR NORMALLY CLOSED OR L. COORDINATE SIZE OF CONDUCTOR TERMINATION LUGS WITH CONDUCTOR SIZES SHOWN ON ELECTRICAL DRAWINGS. NORMALLY OPEN POSITION FOR FAIL SAFE OPERATION TO ACCOUNT FOR FIRE, LOW M. PROVIDE DUPLEX RECEPTACLE MOUNTED ON UNIT FOR FIELD WIRING. TEMPERATURES, OR POWER INTERRUPTION AS REQUIRED BY THE SEQUENCE OF OPERATION. DAMPER OPERATORS SHALL BE MANUFACTURED BY BELIMO, JOHNSON N. PROVIDE FIELD MOUNTED CO2 SENSORS FOR WALL MOUNTING. CONTROLS OR APPROVED EQUAL. PROVIDE DUCT TYPE SMOKE DETECTORS WITH UL LISTING (OR HEAT DETECTORS, IF PERMITTED BY CODE) FOR EACH UNIT TO SHUT DOWN SUPPLY FAN UPON ACTIVATION. DUCT FREE SPLIT SYSTEM PROVIDE 120 VOLT E WITH ITCHES HONEYWELLPROGRAMMING SERIES SUP T OR EQUAL PROGRAMMABLE TYPE WITH 7-DAY PROGRAMMING WITH UP TO TWO 'ONS" AND "OFFS" PER DAY. BATTERY BACKUP SHALL PROVIDE 48 HOURS OF MEMORY INDOOR UNIT (ACU) OUTDOOR UNIT (CU) REFR. MCA/MOCP NOTES RETENTION. OVERRIDE TIMER SWITCHES SHALL BE SPRING WOUND, 6-HOUR, MARK SERVICE MANUFACTURER TH(MBH) MODEL CFM F.L.A. V/PH WEIGHT MODEL AMBIENT F.L.A. V/PH WEIGHT SEER TYPE NORMALLY OPEN TYPE. (LBS) (DB) (LBS) SEQUENCE OF OPERATION IU-1/OU-1 SERVER ROOM MITSUBISHI 9.5 MS-A09WA 215 0.95 115/1 23 MU-A090WA 95 0.63 115/1 55 13 R-410a 14/15 A-F ROOFTOP UNIT CONTROL (DRY BULB ECONOMIZERI NOTES: DURING OCCUPIED HOURS, OPERATE ROOFTOP UNIT SUPPLY FAN CONTINUOUSLY AND OPEN OUTDOOR AIR DAMPER TO MINIMUM POSITION TO MAINTAIN MINIMUM VENTILATION. CYCLE STAGE(S) OF COOLING AND HEATING TO MAINTAIN ROOM A. CONTRACTOR SHALL VERIFY EXACT QUANTITY AND SIZE OF REFRIGERANT PIPING. THERMOSTAT SET POINT (75 DEGREES FAHRENHEIT COOLING, 72 DEGREES B. MOUNT INDOOR UNIT ABOVE THE DOOR AS HIGH AS POSSIBLE IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. FAHRENHEIT HEATING). MODULATE DRY BULB TYPE OUTDOOR AIR ECONOMIZER TO MAINTAIN 55 DEGREES FAHRENHEIT SUPPLY AIR TEMPERATURE WHEN OUTDOOR C. PROVIDE INTEGRAL THERMOSTAT. AMBIENT TEMPERATURE REACHES 60 DEGREES FAHRENHEIT OR BELOW. RETURN D. PROVIDE 4" x 4" CCA TREATED WOOD BLOCKS FAR OU-1 SUPPORT ON ROOF. ECONOMIZER TO MINIMUM POSITION WHEN AMBIENT TEMPERATURE IS ABOVE 60 E. PROVIDE REFRIGERANT DRAIN AND POWER CONNECTIONS ON THE SIDE OF THE UNIT. DEGREES FAHRENHEIT. DUCT MOUNTED SMOKE DETECTORS SHALL SHUTDOWN UNIT UPON ALARM. F. PROVIDE ONE POINT OF CONNECTION. G. PROVIDE CONDENSATE PUMP FOR FIELD INSTALLATION. DURING UNOCCUPIED HOURS, CYCLE THE ROOFTOP UNIT SUPPLY FAN AND COOLING OR HEATING SYSTEM TO MAINTAIN UNOCCUPIED SETBACK TEMPERATURE SET POINTS. OUTDOOR AIR DAMPER SHALL BE CLOSED DURING UNOCCUPIED HOURS. PROVIDE FREEZESTAT IN THE SUPPLY AIR DUCT TO SHUT DOWN THE SUPPLY FAN AND CLOSE THE OUTDOOR AIR DAMPER IF TEMPERATURE IN THE SUPPLY DUCT DROPS BELOW 40 DEGREES FAHRENHEIT. FAN SCHEDULE DUCTLESS SPLIT SYSTEM UNIT MARK SERVICE MANUFACTURER MOUNTING MODEL CFM ESP DRIVE MIN. FAN VFD ELECTRICAL NOTES CYCLE THE DUCTLESS SPLIT SYSTEM TO MAINTAIN SPACE THERMOSTAT SET POINTS (EA, RA, SA) (IN) (BELT/DIRECT) HP RPM (Y/N) V/PH (75 DEGREES FAHRENHEIT COOLING). EF-1 EA GREENHECK CEILING SP-B110 100 0.375 DIRECT 80W 950 N 115/1 C VESTIBULE UNIT HEATER EF-2 EA GREENHECK ROOF GB-081 450 0.5 BELT 1/6 1306 N 115/1 A-B,D CYCLE THE CEILING MOUNTED UNIT HEATER TO MAINTAIN SPACE THERMOSTAT SET POINTS. EF-3 EA GREENHECK ROOF GB-081 530 0.5 BELT 1/6 1420 N 115/1 A-C WALL UNIT HEATER NOTES: CYCLE THE WALL MOUNTED UNIT HEATER TO MAINTAIN SPACE THERMOSTAT SET POINTS. A. PROVIDE WITH MINIMUM 18" HIGH ROOF CURB, BIRDSCREEN AND BACKDRAFT DAMPER. GAS UNIT HEATER B. DIVISION 16 CONTRACTOR TO FURNISH DISCONNECT SWITCH. INTERLOCK THE UNIT HEATER WITH RECEIVING DOOR. CYCLE THE UNIT HEATER TO C. INTERLOCK FAN OPERATION WITH WALL SWITCH. MAINTAIN SPACE THERMOSTAT SET POINTS. D. INTERLOCK FAN OPERATION WITH TIME SWITCH. PUBLIC RESTROOM EXHAUST FAN CONTROL OPERATE EXHAUST FAN(S) CONTINUOUSLY. TURN 'ON' AND 'OFF' BY EQUIPMENT CIRCUIT BREAKER. OPERATE EXHAUST FANS CONTINUOUSLY DURING OCCUPIED GRILLE , REGISTER AND DIFFUSER SCHEDULE HOURS AND SHUT DOWN DURING UNOCCUPIED HOURS PROVIDE A 7-DAY TIMECLOCK TO SWITCH EACH SYSTEM BETWEEN OCCUPIED AND UNOCCUPIED OPERATION. MARK MANUFACTURER MODEL FACE MOUNTING FACE SIZE MAX. MAX. PRESS. NOTES STAFF RESTROOM EXHAUST FAN CONTROL TYPE LOCATION IN NC DROP IN. W.C. SD-1 TITUS 301 RL LOUVER DUCT NECK+1 3/4 30 0.1 A,C,D,F,H-K EXHAUST FAN SHALL BE INTERLOCKED WITH RESPECTIVE RESTROOM WALL SWITCH AND BE ENERGIZED WHEN WALL SWITCH IS 'ON' AND DE-ENERGIZED WHEN WALL SD-2 TITUS 30ORL LOUVER DUCT NECK+1 3/4 30 0.1 A,C,D,F,H,J,L SWITCH IS 'OFF'. SD-3 TITUS TMS PLAQUE LAY-IN 24x24 30 0.1 A-D,H BIKE SHOP EXHAUST FAN CONTROL SD-4 TITUS TMS PLAQUE CEILING 24x24 30 0.1 A-D,H,K EXHAUST FAN SHALL BE INTERLOCKED WITH RESPECTIVE RESTROOM WALL SWITCH AND BE ENERGIZED WHEN WALL SWITCH IS 'ON' AND DE-ENERGIZED WHEN WALL SD-5 TITUS TMS PLAQUE CEILING 1202 30 0.1 A-D,H,K SWITCH IS 'OFF'. TG-1 TITUS 350RL LOUVER WALL NECK+1 3/4 30 0.1 A,C-E,G,H,K EG-1 TITUS 350FL LOUVER CEILING NECK+1 3/4 30 0.1 A,C-E,G-K EG-2 TITUS 350FL LOUVER DUCT NECK+1 3/4 30 0.1 1 A,C,D,G,J,L NOTES: A. NECK SIZE SHOWN ON DRAWINGS. B. RADIAL THROW PATTERN UNLESS OTHERWISE SHOWN ON DRAWINGS. - 03.13.07 REV.PER TOWN COMMENTS C. BRANCH DUCT SIZE SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE SHOWN ON DRAWINGS. ® - 02.20.07 ADDENDUM D. BAKED ENAMEL FINISH, MATCH SURFACE, CEILING, OR DUCT COLOR AS INDICATED ON ARCHITECTRUAL DRAWINGS. - 02.16.07 ADDENDUM - KV 02.13.07 ISSUE FOR PERMIT E. FRONT BLADES PARALLEL TO LONG DIMENSION. - KV 02.09.07 ISSUE FOR BID F. PROVIDE VOLUME DAMPER. No B Data DescHptlon G. PROVIDE NECK FOR DUCT CONNECTION. H. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. L.L. BeqpIE C E � V E D J. PROVIDE OPPOSED BLADE DAMPER ADJUSTABLE FROM FACE OF DEVICE. K. ALUMINUM CONSTRUCTION. L. FRONT BLADES . MAC 14 2097 Wlnd9or OUTSIDE AIR CALCULATION PARALLEL TO SHORT DIMENSION South BUILDING DEPARTMENT SYSTEM ROOM CFM/ CFM/ SQFT PEOPLE OA CFM CA CFM PERSON SQFT 1000 SF QUANTITY REQUIRED PROVIDED RTU-1 STOCK ROOM 0.15 2957 444 UNIT HEATER SCHEDULE ( NATURAL GAS) -- -- -- RETURNS -- 0.3 129 -- -- 39 °` OF FC TOTAL 482 500 MARK MANUFACTURER MODEL MIN. MBH OUTPUT MIN.%EFF. GAS,VALVE CFM MOTPOR V PH NOTES ?GOP,�S.HENp�NT/�+G�e RTU-2 EMERGENCY EGRESS -- 0.1 48 -- -- 5 HALL -- 0.1 120 -- -- 12 GU-1 TRANE GPND004 48.6 80 SINGEL 1050 1/30 115/1 A-H _ MEN S ROOM -- -- 180 -- -- -- '4 kie No. MONOGRAMMING ROOM 20 -- 77 7 1 20 NOTES: %��� OFFICE MANAGER 20 -- 100 7 1 20 I yx wS/0 uALEuo"° OFFICE SUPPORTS 20 -- 130 7 1 20 A. MOUNT 10 FEET ABOVE FINISHED FLOOR WITHOUT OBSTRUCTING AIRFLOW. SAFE 20 -- 80 7 1 20 B. PROVIDE WITH UNIT MOUNTED THERMOSTAT. /Z (/7 STAFF LOUNGE 20 -- 193 50 10 200 C. PROVIDE MANUAL SUMMER/WINTER CHANGE-OVER SWITCH. STAFF RESTROOM -- -- 64 -- -- -- D. PROVIDE NECESSARY MOUNTING BRACKET AND ACCESSORIES FOR HORIZONTAL WALL MOUNTING. UTILITY ROOM -- 0.1 180 -- -- 18 E. DISCONNECT SWITCH FURNISHED BY DIVISION 16 CONTRACTOR. WOMEN'S ROOM -- -- 165 -- -- -- F. PROVIDE WITH STAINLESS STEEL HEAT EXCHANGER. The Shops at Evergreen Walk STORAGE -- 0.15 1403 -- -- 210 G. PROVIDE ELECTRONIC OPERATED GAS CONTROL VALVE. 75 Tamarack Ave OFFICE HALL CORRIDOR___F 0.1 473 -- -- 47 H. PROVIDE VERTICAL FACTORY VENT KIT. Building C, Suite 75 TOTAL 573 575 1 1 South Windsor, CT 06074 RTU-3 SALES -- 0.3 3273 -- -- 982 PTOTAL 982 985 Mechanical, RTU-4 SALES -- 0.3 3273 -- 982 UNIT HEATER SCHEDULE ( ELECTRIC) Specifications 982 985 RTU-5 SALES -- 0.3 3273 -- 982 MARK MANUFACTURER MODEL OUTPUT OUTPUT MIN. NO. V PH NOTES 982 985 MBH KW OF STAGES RTU-6 SALES -- 0.3 2957 -- 887 UH-1 QMARK CWH3307 5.1 1 .5 1 277/1 A-B, D MEN'S FITTING ROOM -- 0.2 316 -- 63 UH-2 QMARK EFF4007 13.7 4 1 277/1 A, C-D Checked By: M TOTAL 1 950 985 UH-3 QMARK EFF4007 13.7 4 1 277/1 A, C-D Job No: 06125.00 RTU-7 SALES -- 0.3 3273 1 982 TOTAL 982 985 RTU-8 SALES -- 0.3 2824 1 847 NOTES: WOMEN'S ROOM -- 0.2 449 1 -- -- 90 TOTAL 937 985 A. PROVIDE WITH UNIT MOUNTED THERMOSTAT. 6985 B. PROVIDE NECESSARY MOUNTING BRACKET AND ACCESSORIES FOR WALL MOUNTING. ENGINEER OF RECORD: NOTE: 1 BALANCE THE ROOFTOP UNIT WITH OUTSIDE AIR REQUIREMENTS AS INDICATED. C. PROVIDE NECESSARY MOUNTING BRACKET AND ACCESSORIES FOR CEILING MOUNTING. Duane S . Henderson 2 OUTSIDE VENTILATION SHALL MEET 2003 INTERNATIONAL MECHANICAL CODE. D. PROVIDE FACTORY MOUNTED DISCONNECT SWITCH. 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0650001687 i U C GENERAL NOTES: N I I I I I I I " 1. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE — ----- OF THE WORK. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE TO OBSERVE THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES,SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT E E - - I DOCUMENTS.AL NOTIFYLARCH TECT TOF ANY RCONFLICTS HOR DISCREPANCIES m - - - - - - - - I- - - - - - - - - 7 - - - - - - - - - - - - - 5 ----------- -------- PRIOR TO SUBMISSION OF BID. o / ( ( MGR'S SUPPORT TEAM I EMP. RR I 2. FURNISH A CONSTRUCTION RECORD SET OF "AS-BUILT" DOCUMENTS TO THE r ; OFFICE' —SAFE TEL/C� E PLOYEE / I I ARCHITECT REFLECTING ANY VARIANCES OF INSTALLED PIPING LOCATIONS OFFICEOR EQUIPMENT CONTRARY TO THE CONSTRUCTION DOCUMENTS PREPARED CL - LIDUNGE o )4'S- (ET R)6'S- I BY THE ENGINEER-OF-RECORD AFTER FINAL INSPECTION OF INSTALLED U PLUMBING SYSTEMS. O GU (60 CFH) ----- 1 o1 I��� - - - - 0 ARCHITECT A COPY OF INSPECTION REPORTS AND APPROVAL J o IF7Z I RTU In D ] of WWI I 3 CERTIIIFICATESTFROM RLOCAL AND STATE INSPECTIONS. UT RTU I (136 CFH) 2 �� - \�___� O 4. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED ODES AND THE �� �1 I � � I M LY I EG C I V-I { I-� 1 (113 CFH) L - - - L �J I W u I REQUIREMENTS OF AUTHORITIES HAVINGJURISDICTION AND ALSO MEET ALL I- - L -J - - ------------- - --------- ----- ---------------------- REQUIREMENTS OF THE LANDLORD. (' \\ � I '� I MEWS 5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE '.. L— ( �— — r' L' EE ENLARGED P N RESTROOM REQUIREMENTS. ------1"c --- — —i I i I SHEET P10� 6. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF CONNECTION c STOCK ROOM I \� \ I - I (ETR)6"S BEFORE START OF PROJECT. RETURNS \ �' / I ;I "G(4�I,F') `\ 7. REFER TO HEIGHTS OFRPLUM PLUMBING RES. FOR EXACT LOCATION AND MOUNTING o o 1 1 �� i � i � N 4 _ _ _ _ _ _ _ _ _ �� _ _ _ _ _ _ _ _ _ _ _L _ _ _ _ _ _ _ _ _ _ -I_ _ _ -_ _ _ _ _ �� -� 8. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE U � v � � o —j- - - - 1 L '•, �/ WM ! I I O ROUTING. �o n v o - - vC = � A 9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. b o .°a 3 CN 10. COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS. �3 of-2"GW LU P201 I / MONO- J I 11. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE BEAMS, o I r RAM LNG WOME ' I FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON PLANS. COORDINATE I�To I I ► ROOM ) EST OOM SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, 4 C4 I GAS PIPING ON ROOF / STRUCTURAL CONTRACTOR.AND GENERAL CONTRACTOR BEFORE CONCRETE P�1 ---------- -- i IS INSTALLED. 1 -' 3"G- - 3'G--- ------------- ---- 2 1 2"G- ---------- I 12. CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING I--- -T------------------ �- I --- I ---- - / - - - --I -----F- �(EfR)3i 4°CW ETR HB OVER TO THE OWNER. zCW�I r - - - � S - -� -- --2'Cw - r s —I - > - ern o� ol I , - (ETR)1"CW - ' I�� ��o� �' - I �I C � � ' � 13. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES. 1 ( I JE- -u j ! 1_( Ll RTU (226 CFH) LI 1*1 I 1 14. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT RTU L - - - k_'t 4 L - - - L•'J� I ROUTE PIPING OVER ELECTRICAL PANELS. ! I I 1-1/2"G 3 �1-i 2"G I RTU 1-1/2"G ( 1 15. PAINT ALL EXPOSED GAS AND WATER PIPING USING RUST INHIBITOR PAINT. o o ----4"G-------- --r-3"G--1 (226 CFH) (226 CFH) I PAINT OWNER. COLOR SHALL BE COORDINATED WITH THE ARCHITECT AND / OR (ETR)3"CW - - - - - - -- - - - - -- - - EMP- - - - - - - � - - - - - - -ICI - - - - - - - - - - - - 1 - T- - I �' I /� � I 16. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10' o, o, ( I ! J MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT. I P� GAS PIPING ON ROOF i '• �j�-' I �/ i % \�� � ,o i I i 17. PROVIDE SHIELDED ADAPTER COUPLINGS FOR CONNECTION OF PVC DWV TO \ CAST IRON AT SLAB ON GRADE. SEE DIVISION 15 SPECIFICATION SECTION I �\ BIKE SHOP I "DRAINAGE AND VENT SYSTEMS" FOR MORE INFORMATION. 18. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE. 19. PROVIDE CHECK VALVES IN HOT AND COLD WATER SUPPLIES FOR MOP SINK FAUCETS DOWNSTREAM OF SHUTOFF VALVES. I ! 1 1 I y, ' f I ���:ti:• I � I 3 ! � I ! PLUMBING PLAN NOTES: ��o o ROUTE 4" GAS TO EXISTING BANK OF METERS. PROVIDE 1645 CFH AT 7 I ! LOW PRESSURE. TOTAL DEVELOP LENGTH OF 350' AND PRESSURE DROP OF 0.5 INCH W.C. FIELD VERIFY EXACT LOCATION, CAPACITY & I PRESSURE OF GAS SERVICE WITH LOCAL GAS COMPANY. N COORDNINATE GAS ROUTING WITH LANDLORD AND LOCAL GAS I ! COMPANY. ROUTE 1" GAS DOWN THRU ROOF AND CONNECT TO WATER HEATER. _ O3 CONNECT NEW 2" CW TO EXISTING 2" CW TAP. FIELD VERIFY EXACT I ! ! ! 7 I ! LOCATION AND SIZE OF EXISTING PRIOR TO START OF CONSTRUCTION. rr `y I O4 DO NOT INSTALL ANY PLUMBING PIPES OVER ELECTRICAL PANELS OR ! f I EQUIPMENT. _oo� - -( 2 - - - - - - - - --- - - - - - - - - - - - - - - - - ol- - -- - - � - - TI �--`- -- -- -- I I I oRTU (226 CFH) - RSU (226 CFH) I _ (ETR)HB u� ( I ! r _ \1 1 r �• � �� !MEWS FITTIN \ LJ---1-1/2"G--------- (TYP)(°1 / ---------1-1/2"G----' --I 1C 1-1/2 U----- ! ( P�1 ROOMS \ 6 (22s CFH) \ I I oWOMEN'S FITTING 0 G � I ROOMS - - - - -- - - - - - � - - - - - - - - - - � - - -- - - -' I - - - - - - .} - - - - - - — - - - - �'— - - - - - 3- 1- —'� o; I - -------------- - Y + ETR HB r.._..._. ..__ II 3 � I I I `� scripUon o No B Date De - - - — - o - - - - - - - - - - - - I - - - - - - - - - - - - - - - - moo - - CAI - - - - - - - - - - - - � -o 11 lloo�o 77 g L.L. Bean I I o, � ) ( E D) C.7) C.2) ( C B (,� U,0„1111IIIIII11,ryr, GONNF"...,, �� �� S.HEjy`jri�; ,a Plo,ta70D @ a 1 PLUMBING FLOOR PLAN =�q��A SCALE: 1/8"=1'-0" N ' SSto NGX hhl" 11 ' Illl `\ �1 7 �I The Shops at Evergreen Walk South Windsor, CT a m a Plumbing Floor Plan n 0 0 m a 0 a m 3 9 a Checked By: MS n m 0 Job No: 06125.00 a E a 'o 0 F U ENGINEER OF RECORD: P 10 1 Duane S . Henderson 0 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 m WEB: WWW.HENDERSONENGINEERS.COM fO 0650001687 a 0 o N O C N m m J J Um4 PLUMBING PLAN NOTES: In O1 CONNECT NEW SANITARY PIPE TO EXISTING SANITARY. FIELD VERIFY ¢ i EXACT LOCATION, SIZE AND DEPTH PRIOR TO START OF CONSTRUCTION. E O2 CONNECT NEW 3" VENT TO EXISTING 3" VENT. FIELD VERIFY EXACT R LOCATION AND SIZE PRIOR TO START OF CONSTRUCTION. m o O ROUTE 3/4" CONDENSATE DRAIN LINEDOWN IN WALL AND DISCHARGE o INT ---- ----� --- ---- ---- ---- ---- ---- ---- - rn \, -- - - - - -- - - - - -- - - �_ - - - - - - -I - -- - - - - - -�) - - — - — - - — - - T T -� - T - T I L — - — -I -L---3- � � - - - — I� O4 3 00 COMBUSTION U MIS ISTIONTH RANDPVENTT UP PER CODE. ROOF. U --------------- -------------------------------- I L-2 O (� O5 FOR CONTINUATION SEE PLUMBING SHEET P101. O L--- -- 3L-- ---- WHA x EMP. RR 3 EMP. _ WC-2 (rrF) TELICOM— I FCO WC_2 TELICOM ' " EMPLOYEE — EMPLOYEE /4 LOUNGE 2"VBF4- J It f LOUNGE _ ET 6"S-� �i AP -f IU REFER TO MECH DWGS FOR INFORMATION WCO �\ / Fp ~ WHA Fp % SK ��\ - SK TP-2 X I 1-1/2"CW 0 / P201 -------------- -- �I -- /-- SH !n ro o N o '14 W C7 - - 3/4"HZ Q) W W v n a - I UR I - d 104 N WCO 3/,4"H & CW UR [ p i O U ,� O �'v __________ i u w O 3 ��--4S ti AP �J I n U U w� wu MPF WC-2 WHA WC i �J q / P201 WC \ ? WC^ _ o WCO r FD N I FD SL) F=I 7T_ FTF s•. a I J s WC-1 WCO I - -- 1-1/2"CW - \ ' (�L-1 MEN'S 3/4„HW CP RESTROOM I I 3/4'Hw L-1 3 "WT —3"W-- 3 3 4"Hyy MEWS P201 \� l I� �\ P201 �I L 1 RESTROOM LJ FIID, wco -� — �� 2� - �,� 1"HW / MS UTILITY u �\� UTILITY ALSO MS WC-2 9 \ L c WH t WOMEN'S l --- - \\\ THRU ROOF 1"CW 1"CW-- 2"CW V RESTROOM I ? - - - - -�- - -- - - - - - - - -CI-- - --�- - —i - 2^WF_- r-1 - o�' �-F�F-I - - - - _`l am4�`• - - -- -\-1- - - - - - -- - - - --I ��-2"CJW/ HEADER 0 M \ 1„G(40 CFH) - -\. - - - - ®�Qs of0n - � - - - -- - - - I\4 ) 4 ET WH, -P20 _' 2 1 WC-1 2 W W? P20, P20, 1 3 J N I w l 1"H & GW 2 fp �2„W- DF O MONO- U --/4 5— 2 ? MONO i M i FD c� DF GRAMMIS4,4N & 3 WC-1 I I 3V ' GRAMMIN WC-1 1/2"GW / ROOM I ROOM WOMEN°S I RESTROOM - -2W I WHA TP-1 AP P III FG�O �N I I I I I I I I 5 `(B ) WASTE AND VENT DOMESTIC WATER 2 ENLARGED PLUMBING FLOOR PLAN ENLARGED PLUMBING FLOOR PLAN SCALE: 1/4"=1 '-0" N 4 SCALE: 1/4"=1 '-0" N WCO 2"V O WHA �I (TYP) I 2'v 3/4" FCO 2 W� � SH Zv 2'VBF V 1 C ryCUR O No By Date Description L.L. can WCO SK \ Y � I ` WHA I FD / 1-1/2"CW \ Rs 3,v TP-1 SK low WCO WC-1 Y 2��� I WC-1 i 3�k 4"S � � ETR-3'VfR I ! \ ....., core, zv 2 W 2�r 1'1�� G �� 1/2 T / z"�w �'' �O�,.!iEryVE/0. \ 3'ti l pF // \���- FD 2��� \ _ aP a�Y �O o WC-2 = a ? WCO 1 2 N 1 \R 1 ::Ij /sh 3 / `@ < ' �`$° 3V �4lril I@ �u WCO 2b \\ 3W YY WCo 3/4,�w 3/�,RV� 31k.Gw o Yam/ WC-2 \ WC-2 1°H w V 3 DF `\1 WCO I 4"g z'y � z'y /� \ 1 fC I V �4 Hw Y FCO 3 J v FD / L-1 /•% �,���� Q JS WC-1 � � � 0 WC-2 NI \� 4 3 FCO 1-1/2"CW HEADER 1 MS The Shops at Evergreen Walk 1/2" we 1 South Windsor, CT V "W L-1 O wC 1 Enlarged Plumbing WCO /� WH L , Floor Plan and Riser Y a ti a 2"CW HEADER L-1 1/2 Checked By: MS a V B„O WASTE AND VENT RISER DIAGRAM DOMESTIC WATER RISER DIAGRAM FD Job No: 06125.00 E NOT TO SCALE NOT TO SCALE 1/2'T102 �i ' a 'o 0 0 F 0 9 ENGINEER OF RECORD: C 3 Duane S . Henderson a 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 to TEL: 913-307-5300 FAX: 913-307-5400 m WEB: WWW.FIENDERSONENGINEERS.COM 0650001687 0 o 0 ro a C W m m J J i i PLUMBING FIXTURE SCHEDULE PLUMBING LEGEND: UM4 2 MARK FIXTURE TRIM S DOMESTIC COLD WATER (CW) w PROVIDE THERMOMETER IN TEE PROVIDE AUTOMATIC VACUUM LITTLE GIANT # VCC-20ULS, ABS TANK AND MOTOR ELECTRICAL REQUIREMENTS: 120-VOLT, 1.5 FULL LOAD S DOMESTIC HOT WATER (HW) FITTING I ^� RELIEF VALVE ABOVE TOP OF CP COVER, 1/30 HP VERTICAL TYPE PUMP WITH AMPS. TANK STAINLESS STEEL MOTOR SHAFT, POLYPROPYLENE S --- HOT WATER RECIRCULATION (HWR) m HOT WATER TO FIXTURES IMPELLER, CHECK VALVE, 3/10 GALLON RESERVOIR, rn COLD WATER SUPPLY TO S--VBG- -S PLUMBING VENT BELOW GRADE (VBG) m PIPE UNIONS (TYPICAL) ABOVE TOP WATER HEATER CAPABLE OF 45 GALLONS PER HOUR AT 10' OF m OF TANK (TO FACILITATE REMOVAL OF HAD' SVS PLUMBING VENT ABOVE FLOOR (V) co WATER HEATER) TYPICAL SHUT-OFF VALVE O HAWS MODEL 1011 SELF CONTAINED DUAL PURPOSE N/A S- -VBF- -S PLUMBING VENT BELOW FLOOR (VBF) CHECK VALVE OF DRINKING FOUNTAIN, STAINLESS STEEL FINISH, WALL rn SECURE PIPE HANGER PROVIDE DIELECTRIC PIPE UNION AT MOUNTED, SELF-CLOSING POLISHED CHROME FRONT SSA SANITARY PIPING ABOVE FLOOR (S) .T TO STRUCTURE TANK CONNECTION FOR CONNECTION COLD WATER BRANCH TO MOUNTED PUSH BUTTON VALVES, ONE PIECE S--S--S SANITARY PIPING BELOW FLOOR (S) C REFER TO SPECIFICATIONS OF DISSIMILAR METALS (TYPICAL) - EXPANSION TANK POLISHED CHROME PLATED SHEILDED BUBBLER, � FOR CONNECTIONS ANTI-SQUIRT ANGLE STREAM, 32"X18.5" S W i WASTE PIPING ABOVE FLOOR (W) 0 LINESIZE GAS SUPPLY TO WATER INSTALL ASME TEMPERATURE PROJECTION FROM WALL. HEATER IFS AND PRESSURE RELIEF VALVE MOUNTING HEIGHT: 35 3/4" TO CENTER LINE OF S —W--S WASTE PIPING BELOW FLOOR (W) THREADED STEEL ROD PIPE HANGER NEXT TO ELBOW FURNISHED WITH WATER ADA BUBBLER, 40 3/4" TO CENTER LINE OF FROM CW SUPPLY GAS-FIRED WATER HEATER PER � HEATER STANDARD BUBBLER. SCDS CONDENSATE DRAIN (CD) WITH NUT AND WASHER TO HEATER, NO SPECIFICATIONS AND SCHEDULE S—ACDS AUXILIARY CONDENSATE DRAIN (CD) BOTH SIDES PIPE UNION: DIELECTRIC INTERVENING VALVES BURNER THERMOSTAT AND APPLIANCE CONNECT TO TOP OR SIDE OF ZURN COMPANY #ZB-1400, DURA-COATED CAST N/A REFER TO SPECIFICATIONS IF REQUIRED FOR TANK AS REQUIRED FOR FCO IRON BODY, "LEVEL-TROL" ADJUSTABLE FLOOR S WSi WATER SERVICE (WS) FOR ROD SIZE DISSIMILAR METALS REGULATOR PROVIDED WITH HEATER MODEL FURNISHED (TYPICAL) CLEANOUT, INSIDE CAULK CONNECTION WITH GAS WELDED STEEL EXPANSION GAS COCK AND WATER TIGHT ABS TAPERED THREAD S--o y�� ELBOW UP & ELBOW DOWN IN PIPING CLEVIS HANGER, SHOWN FOR CLARITY TANK WITH POLYPROPYLENE PROVIDE HARD COPPER RELIEF INTERNAL PLUG ADJUSTABLE HOUSING, HEAVY- S-ro S S- 5 TEE UP & TEE DOWN IN PIPING REFER TO SPECIFICATIONS FOR VALVE DISCHARGE PIPE FULL DUN SCORIATED SECURED ROUND TOP, POLISHED J LINING, FDA APPROVED FOR UNION WITH GROUND JOINT I DOMESTIC WATER SERVICE 1 SIZE OF VALVE OUTLET. BRONZE FINISH, INSTALL FLUSH WITH FINISHED OTHER HANGER TYPES FOR PIPE CODE. REFER TO FLOOR BALL VALVE C SERVED & SPACING PROVIDE REDUCER AT EQUIPMENT III TERMINATE OVER APPROVED FLOOR. V N o BUTYL DIAPHRAGM CONNECTION IF REQUIRED:4 RECEPTOR WITH AIR GAP PER S SHUTOFF VALVE .D o u ZURN COMPANY SERIES ZN-415-P, COATED CAST STRAINER: ZURN COMPANY "TYPE B", 5' v a u �I I N PLANS FOR LOCATION. FU IRON FLOOR DRAIN, TWO-PIECE BODY, DOUBLE DIAMETER NICKEL BRONZE FINISH. }--\f--$ CHECK VALVE o u PROVIDE FOR INSULATED PIPING FILL TANK WITH AIR 6" LONG DIRT LEG v C n q DRAINAGE FLANGE, INVERTIBLE NON- WASTE: SIZE AS NOTED ON DRAWINGS, CAST IRON AT EACH HANGER A SECTION OF PRESSURE TO MATCH aj n So HIGH DENSITY INSULATION OR WATER PRESSURE, SET WATER HEATER ON CONCRETE INSTALL DRAIN VALVE PUNCTURING FLASHING COLLAR, WEEPHOLES, P-TRAP UNDER FLOOR. S y+--S STRAINER y v a v STYROFOAM BILLETS THEN OPEN VALVE EQUIPMENT PAD PER SPECIFICATIONS` FURNISHED WITH WATER BOTTOM OUTLET INSIDE CAULK CONNECTION, �� 9 [ REFER TO SPECIFICATIONS FOR HEATER ADJUSTABLE ROUND SUPER-FLO STAINER, 5-- � STRAINER WITH BLOWOFF U 8 MORE INFORMATION FLASHING CLAMP WITH 24N24" 4LB. LEAD RECIRCULATION PUMP P ' M PL' u" REFER TO SPECIFICATIONS, SCHEDULES, AND NOTES FOR MORE INFORMATION. PIPING FLASHING FOR FLOOR DRAINS INSTALLED ABOVE PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. VERIFY SLAB ON GRADE. 1/2" TRAP PRIMER RELIEF/SAFETY VALVE FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. CONNECTION SIZES AND LOCATIONS WITH WATER HEATER FURNISHED. REFER TO FLOOR PLANS CONNECTION. q' PROVIDE INSULATION SHIELD FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION FOR PIPE SIZES AND CONTINUATIONS. PROVIDE SEISMIC STRAP OR BRACING WHEN REQUIRED S 4 WATER HAMMER ARRESTER WITH FOR INSULATED PIPE PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. BY LOCAL AUTHORITIES. PROVIDE HEAT TRAP ON COLD WATER SUPPLY WHEN REQUIRED BY AMERICAN STANDAR #0476.028 "oQUALYN" 20"X17" SLOAN ERF-85-8 LO-FLO FAUCET, BATT. OPERATED S PDI SIZES: A, B, C, D, AND E LOCAL AUTHORITIES. POWER WIRING AND DISCONNECT SWITCH ARE SPECIFIED IN DIVISION 16. L-1 OVAL SELF-RIMMING WHITE VITREOUS CHINA SOLENOID VALVE UTILIZING FOUR "C" BATTERIES, FIXTURE WITH FAUCET LEDGE AND FRONT "OPTIMA" SENSOR, CHROME PLATED CAST BRASS, rnrn THERMOSTATIC MIXING VALVE 3 PIPE HANGER DETAIL 2 SMALL EXPANSION TANK 1 GAS FIRED WATER HEATER OVERFLOW. McGUIRE #155A GRID DRAIN WITH 4" CENTERSET METERING FAUCET WITH 0.5 GPM AERATOR Y PRESSURE GAUGE TAILPIECE, McGUIRE # 2165CCLK LOOSE kEY MIXING VALVE: SYMMONS "4-10" NOT TO SCALE NOT TO SCALE NOT TO SCALE COMPRESSION ANGLE STOP VALVES WITH RISERS AND ESCUTCHEONS, McGUIRE #8872CF 1-1/4" 17 THERMOMETER GAUGE TUBLAR CHROME PLATED BRASS UNION ADJUSTIBLE P-TRAP AND WASTE ARM IWTH CLEANOUT PLUG AND ESCUTCHEON, TRUEBRO MANUAL / AUTOMATIC AIR VENT OR VACUUM RELIEF "HANDI LAV-GAURD" #102 INSTALLATION KIT FOR TURN AWAY WATER AND WASTE PIPES. VALVE ADAPTER(S) AS GAS FIRED ROOF-TOP AIR PIPE REDUCED FROM i S DIRECTION OF FLOW REQUIRED TO CONNECT CONDITIONING UNIT OR BRANCH PIPE SIZE TO UNIT FROM GREASE CONDENSATE DRAIN PIPE MAKEUP AIR UNIT PER CONNECTION SIZE, AT UNIT EXHAUST FAN 2'-0" MINIMUM ELJER "MAYBURNE" 051-2245, 802-0325 SLOAN ERF-85-8 LO-FLO FAUCET, BATT. OPERATED TO STUB ON MECHANICAL PLANS CONNECTION STUB (TYPICAL) L-2 SUPPLIES W/KEY STOP AND 804-1190 TRAP TO SOLENOID VALVE UTILIZING FOUR "C" BATTERIES, WALL HYDRANT EQUIPMENT. PROVIDE 1 4"PVC EXHAUST, 1 MEET ADA ACCESIBLITY, INSULATE EXPOSED DRAIN 'OPTIMA" SENSOR, CHROME PLATED CAST BRASS, CLEANOUT (CO) DRAIN PIPE ONE GAS PRESSURE REGULATOR LINES AND HOT AND COLD WATER STOPS AND 4" CENTERSET METERING FAUCET WITH 0.5 GPM AERATOR NOMINAL PIPE SIZE ONLY IF SHOWN ON PLANS, SCHEDULE 40 PIPING BELOW LAVATORY W/BROCAR TRAP WRAP. MIXING VALVE: SYMMONS "4-10" WALL CLEANOUT (WCO) LARGER THAN SCHEDULES, AND GAS OR CD PIPE, MOUNTING HEIGHT: 34" FLOOR TO RIM. CARRIER: ZURN COMPANY SERIES Z-1231, FLOOR- EQUIPMENT CONNECTION SPECIFICATIONS SEE FLOOR PLANS „,e.. O FLOOR CLEANOUT FCO 1/4"x1-1/2" CADMIUM MOUNT, SINGLE LAVATORY CARRIER W/CONCEALED ( ) SIZE, MINIMUM 3/4" FLASH } PLATED LAG SCREWS GALVANIZED STEEL CLAMP. r L �-4"PVC INTAKE, ARMS, LEVELING AND SECURING SCREWS, ❑o EXTERIOR CLEANOUT (ECO) GROUND JOINT PIPE UNION / WATERTIGHT SEE SCHEDULE 40 STRUCTURAL UPRIGHTS AND BLOCK BASES, PROVIDE TRAP DEPTH AND GAS SHUT-OFF COCK DO NOT CLAMP PIPE TIGHT SEE +// o NOTE 1 o NOTE 2 SECURED TO FLOOR 1/2" BOLTS AND ANCHORS, ® FLOOR DRAIN (FD) SIZE & TYPE GREATER OF STATIC OR FULL SIZE OF BRANCH COORDINATE TWO 4" x 4" x 12" PLASTIC FLASH CHROME PLATED ESCUTCHEONS, FOR INSTALLATION 1/2" PLUS STATIC PIPE. REFER TO PLAN INSTALLATION OF SUPPORT BLOCKS OR CCA M WATERTIGHT AT METAL STUD WALLS. ® FLOOR SINK (FS) SIZE & TYPE PRESSURE IN INCHES FOR SIZE OF BRANCH PIPE. 18N18%3/16" TREATED TIMBERS. TOE OF WATER COLUMN ROOF WALKWAY „ NAIL BLOCKS TOGETHER f-ROOF ROOF CURB FIAT #TSB 3003 36"x24"x12" HIGH PRE-CAST FAUCET SHALL BE AMERICAN STANDARD NO. 01 ROOF DRAIN (RD) SIZE & TYPE BRANCH OFF TOP OF GAS MATERIAL FOR BASE 9 k TO PROVIDE MINIMUM 7 INCH CURB m� r�(p/ MS TERRAZZO FLOOR MOP SINK. CONTRACTOR SHALL 8344.112 EXPOSED TYPE DOUBLE FAUCET, CHROME c� ISOMETRIC FLOOR PENETRATION 6" TALL VENT OPEN TO PIPE MAIN. REFER TO SHEET THAT IS CLEARANCE UNDER PIPES I _ , ��-�\,� llllllllll> F IDID FURNISH AND INSTALL THE SINK, SUPPLY AND PLATED BODY WITH BACK FLOW PREVENTER AND 5 PLANS FOR PIPE SIZES. ATMOSPHERE ONLY COMPATIBLE WITH - � - - � DRAINAGE FITTINGS, AND CONNECT AS DETAILED FEET OF RUBBER HOSE. MOUNT FAUCET 24" ® CONNECT TO EXISTING WHERE REQUIRED BY ROOF CONSTRUCTION ON THE DRAWINGS. ABOVE FLOOR OF SINK. CODE FOR LENGTH OF �- ARRANGE PIPE AND ELBOWS AND LANDLORD. WASTE: DRAIN SHALL BE ZURN CAT. NO. Z-415 DRAIN PIPE TO ALLOW FOR EXPANSION PROVIDE MULTIPLE AND CONTRACTION OF PIPE BASE SHEETS OR CAST IRON FLOOR DRAIN WITH ADJUSTABLE. O PLUMBING PLAN NOTE CALLOUT RUNS - TRIM THE TIMBER DOUBLE DRAINAGE FLANGE WITH WEEPHOLES AND DISCHARGE AWAY FROM ROOF TRUSS, REFER TO FLASHING CLAMP DEVICE. PLUMBING EQUIPMENT DESIGNATION (CONTRACTOR SERVICE AREAS OF UNIT, _ ROOF INSULATION AS REQUIRED TO STRUCTURAL DRAWINGS OR AT ROOF DRAIN OR 6" LONG DIRT LEG FULL ACCOMMODATE 4 ELKAY ILGR-4322-L WITH BASKET STRAINER, CHICAGO FAUCETS NO. 1100 LO-FLO; WITH 1000 O FURNISHED AND INSTALLED) REFER TO PLUMBING DIRECTION OF GRAIN GUTTER IF REQUIRED BY SIZE OF BRANCH PIPE, ( ROOF DECK VARIATIONS IN SK TRAP WITH CLEANOUT, K-7607 SUPPLIES WITH HANDLES; 8" CENTERS; L8 8" SPOUT WITH FIXTURE OR EQUIPMENT SCHEDULES SUPPORT PIPES ON ROOF WITH BOTTOM MINIMUM 3" ROOF ELEVATION KEY STOP. FINISH: HAND BLENDED SATIN FINISH 1.6 GPM LAMINAR FLOW. RT MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR LOCAL AUTHORITIES OR 4"PVC EXHAUST, 4"PVC INTAKE, SHOWN ON PLANS. PER SPECIFICATIONS ABOVE ROOF SCHEDULE 40 SCHEDULE 40 NICKEL BEARING STAINLESS STEEL. \1j FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) NOTES: OMIT CONDENSATE DRAIN ON MAKEUP AIR UNIT. ARRANGEMENT SHOWN IS SCHEMATIC. 1 ADJUST TO SUIT FIELD CONDITIONS. PROVIDE CONNECTIONS SHOWN IN EQUIPMENT 1. EXHAUST VENT TERMINAL FURNISHED BY WATER HEATER MANUFACTURER O FIAT ADA3636 BARRIER FREE SHOWER, 36"x36" SHOWER VALVE: POWERS MODEL E425-D LO-FLO MECHANICAL OR FIRE PROTECTION NOTE CALLOUT MANUFACTURER'S INSTALLATION INSTRUCTIONS. VERIFY CONNECTION LOCATIONS BEFORE LOCATE SUPPORTS AT 4' SPACING FOR PLASTIC PIPE AND AT THE FOLLOWING AND INSTALLED BY CONTRACTOR. CSHD ADA COMPLIANT. SUPPLY WITH OPTIONAL HAND HYDROGAURD THERMOSTATIC MIXING VALVE, LEVER 1 INSTALLING PIPE RUNS. REFER TO SPECIFICATIONS FOR PIPE AND FITTING MATERIALS AND SPACING FOR METAL PIPE: 5"=16' 4"=14' 3"=12' 2-1/2"=11' 2"=10' 2. INTAKE VENT TERMINAL FURNISHED BY WATER HEATER MANUFACTURER HELD SHOWER HEAD AND SLIDE GUIDE. HANDLE WITH 1.5 GPM FLOW RESITRICTOR, P1 DETAIL REFERENCE INSTALLATION. PROVIDE DIELECTRIC UNION IF CONNECTING DISSIMILAR METALS. FOR PIPE 1-1/2"=9' 1-1/4"=8' 1"=7' 3/4"=6'. PLACE A SUPPORT AS CLOSE AS POSSIBLE AND INSTALLED BY CONTRACTOR. THERMOSTATIC MOTOR COMPENSATES FOR TEMPERATURE SIZE(S) REFER TO FLOOR PLANS, OR CODE REQUIREMENTS FOR HVAC UNIT TONNAGE. SLOPE TO EACH ELBOW AND TEE. PLACE BASE SHEETS ON ROOFING BEFORE GRAVEL IF 3. SUPPORT PVC INTAKE AND EXHAUST PIPES ABOVE ROOF PER MANUFACTURER'S FLUCTUATIONS INDUCED BY WATER PRESSURE AND AFF ABOVE FINISHED FLOOR TEMPERATURE CHANGES. CONDENSATE PIPE AS MUCH AS POSSIBLE TOWARD DISCHARGE, 2% MINIMUM. PROVIDE ANY. SET BLOCKS FREE ON BASE SHEETS. STACK BLOCKS AND NAIL THEM INSTALLATION INSTRUCTIONS. CLFANOUTS IN ENDS AND TURNS OF PIPE PER LOCAL CODE REQUIREMENTS: ADAPTER WITH TOGETHER WHERE REQUIRED TO ELEVATE PIPING. INSTALL PIPE TO ALLOW FOR 4. PVC EXHAUST AND INTAKE SHALL BE INSTALLED A MINIMUM OF 10'-0" RONTEFLOOR INDRAIN LWITH ADJUSTABLE.E ZURN CAT. NODOUBLE CAST AFG ABOVE FINISHED GRADE THREADED CLEANOUT PLUG. PROVIDE MINIMUM 6" CLEARANCE TO ROOF UNDER PIPES. EXPANSION AND CONTRACTION. FROM ANY PARAPET WALL. DRAINAGE FLANGE WITH WEEPHOLES AND FLASHING BFF BELOW FINISHED FLOOR CLAMP DEVICE. BFG BELOW FINISHED GRADE 6 CONNECTIONS TO ROOF—TOP UNIT GAS PIPE SUPPORT ON ROOF �� WATER HEATER EXHAUST AND INTAKE DETAIL PERCISION PLUMBING PRODUCTS MODEL P-1 DR STAINLESS STEEL HINGED ACCESS PANEL, ,2"x18 ON DOWN NOT TO SCALE J NOT TO SCALE y' NOT TO SCALE TP P-2 AUTOMATIC BRASS TRAP PRIMER ACTIVATED CONTAINING BALL SHUT—OFF VALVE, TRAP PRIMER, BY DROP IN BUILDING WATER PRESSURE. MANUFACTURED DISTRIBUTION MANIFOLD. SIZE FFA FROM FLOOR ABOVE TRAP PRIMER FOR NUMBER OF TRAPS SERVED FFB FROM FLOOR BELOW PER MANUFACTURER'S SPECIFICATIONS. ACCESS DOOR SHALL BE FIRE RATED WHEN INSTALLED IN GPM GALLON PER MINUTE PROVIDE 6" HIGH VENT TEE WITH CLEANOUT PLUG RATED WALLS. E INVERT ELEVATION PIPE, OPEN TO THE WATERLESS CO. "SONORA" MODEL #2003 WALL N/A ATMOSPHERE INCREASE TO MINIMUM ONE CUD DRAIN UNIT TFA TO FLOOR ABOVE PIPE SIZE LARGER THAN FINISH: WHITE, VITREOUS CHINS. TFB TO FLOOR BELOW SEE PLAN FOR SIZE AND UNIT CONNECTION, MINIMUM 3/4" MOUNTING HEIGHT: 17" FLOOR TO RIM. DISCHARGE LOCATION VTR VENT THRU ROOF CRANE 1.5 GPF "PLACIDUS" #3-446E OR KHOLER FLUSH VALVE: SLOAN OPTIMA PLUS 8111, LO—FLO, SLOPE PIPE TOWARD WC-1 1.6 GPF "KINGSTON LITE" #K-4330—ET. BATTERY OPERATED INFRARED SENSOR DIAPHRAGM DISCHARGE, MINIMUM 2% 1 DRAIN PAN SUSPENDED FINISH: WHITE, VITREOUS CHINA. TYPE, COURTESY FLUSH BUTTON, DECORATIVE PROVIDE CLEANOUTS IN — BELOW UNIT WC-2 MOUNTING HEIGHT: WC-1, 15" FLOOR TO TOP OF CAP, 1"I.P.S. ANGLE STOP, ADJUSTABLE TAIL TURNS AND ENDS OF PIPE. CID SEAT. PIECE, VACUUM BREAKER FLUSH CONNECTION, USE TYPE 'M" OR "L" HARD MOUNTING HEIGHT: WC-2, 18" FLOOR TO TOP OF WALL AND SPUD FLANGES. COPPER FOR 3/4" AND 1" CD FLEXIBLE CONNECTION WHEN FIXTURE BRANCH CONNECTION SCHEDULE PIPE SIZE, AND TYPE "DWV" ATTACHED TO MOTORIZED SEAT. SEAT: OLSONITE #10CC OPEN FRONT SEAT, COLOR FOR PIPE AND FITTINGS UNIT (6" LENGTH OF TO MATCH FIXTURE. FIXTURE COLD WATER HOT WATER WASTE VENT CARRIER: ZURN COMPANY SERIES Z-1203 CAST LARGER THAN 1" REINFORCED NEOPRENE WATER CLOSET (FV) 1-1/4" -- 4" 2" HOSE WITH HOSE CLAMPS.) IRON CLOSET FITTING SINGLE OR DOUBLE AS TRAP 2" DEEPER THAN FAN OTHERWISE PROVIDE UNION APPLICABLE, COMPLETE WITH VENT AND THREADED URINAL (WATERLESS) -- -- 2" 2" TOTAL STATIC PRESSURE CONNECTIONS, ADJUSABLE CANTILEVER CHAIR, LAVATORY 1/2" 1/2" 2" 1-1/2" (MINIMUM 4" DEEP) TEE WITH CLEANOUT PLUG LEAD GASKET. 1.6 GPF DRINKING FOUNTAIN 1/2" -- 2" 1-1/2" 1"G I ROOF PENETRATION ZURN COMPANY #Z-1446, COATED CAST IRON N/A MOP SINK 1 1/2" 1 1/2" 1 3" 1 2" 1 ly (13 /' GFI� WCO CLEANOUT TEE, HUB AND SPIGOT CONNECTION, RTU �/ 6 CFN) �\ (¢GBRONZ PLUG.COVVEREROUND STAINLESS STEEL WALL ACCESS SINK DRAIN 1/2" 1/2" 2" 2" (136 CFH) \ yyH (40 CFH) PIPING ARRANGEMENT SHOWN IS SCHEMATIC: ADJUST AS REQUIRED TO COVER WITH SCREW. / / AMC �1\ SUIT ACTUAL INSTALLATION CONDITIONS. ROUTE PRIMARY AND SHOWER 1/2" 1/2" 2" 2" ", BRONZE SECONDARY DRAIN PAN CONDENSATE LINES SEPARATELY TO DISCHARGE _ INTO RECEPTOR WHERE SHOWN ON PLANS WITH AIR GAP OF TWO PIPE ( WM MEASOULING70HAMBER? BRONZE BOTTOMASE PLATE,D N/A NOTE: DIAMETERS. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS. PIPE SIZES SHOWN ARE MINIMUM. STAINLESS STEEL TRIM AND BOLTS, THERMOPLASTIC STRAINER, OSCILLATING PISTON MEASURING ELEMENT, STRAIGHT READING HERMETICALLY SEALED REGISTER, No B Date Description \ REGISTRATION IN US GALLONS, MAGNETIC DRIVE, AND 1112rH) (452"CFH) ^�) �1, AIR HANDLING UNIT CONDENSATE DRAIN COMPLIANCE WITH ANSI / AWWA C700. PROVIDE WITH L.L. Bean (626 G (ZZ6/2G NOT TO SCALE REMOTE READING SYSTEM IF / AS REQUIRED. Y/ RTU (226 CFH) CFh) \\\ NOTES: \I, 5 1. FIXTURES IN THIS SCHEDULE OR THEIR APPROVED EQUIVALENT ARE PROVIDED BY THE PLUMBING CONTRACTOR. SUBMIT SHOP DRAWINGS ON EACH OF THESE ITEMS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION RTU I \r J (113/4G G' CFN RTU \ AND INSTALLATION REQUIREMENTS. VERIFY ROUGH-IN REQUIREMENTS WITH MANUFACTURER'S INSTALLATION >\ /3 GFI�) /•\ ) ^ 8 (226 CFH) \> INSTRUCTIONS AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. REFER TO THE ARCHITECTURAL DRAWINGS (113 CFH) / 1 / 57 !! \ / FOR THE PLUMBING FIXTURE MOUNTING HEIGHTS. // (8 ��/J RTU (226 CFH) I`\ �I // TOTAL CONNECTED NATURAL GAS LOAD 2. INSTALL PLUMBING FIXTURES WHERE SHOWN ON PLANS COMPLETE WITH TRAPS, STOPS, AND ALL FITTINGS. x / l Y I / 3. PLUMBING FIXTURES SHALL BE COMPLETELY INSTALLED WITH ALL FITTINGS AND MOUNTING ACCESSORIES. ounai°°°°nuuui� "G� I�) C N) \ / �) �1� /'\ \ I� 1. // MECHANICAL EQUIPMENT 4. FIRMLY ANCHOR ALL PLUMBING FIXTURES AGAINST MOVEMENT; LOCATE IN CENTER OF AREA ALLOWED. o`" FCONNF'4, /1 G GF \\ 3"G GF 1 1/ / 5. SET FIXTURES FOR HAND WASHING OR SHOWERING TO 110 DEGREES F. MAXIMUM HOT WATER TEMPERATURE. �.°��f� """H""' CT '3 JU (226G / (226 2„G / EQUIPMENT ?�P ass er✓pF��'G \1\ RTU (226 CFH) GFN)� DESIGNATION QUANTITY DESCRIPTION CFH (EACH) TOTAL CFH RTU �\ 7 (226 CFH) RTU-1 1 ROOF TOP UNIT 113 113 GAS FIRED HOT WATER HEATERS = r % Y\\Ia� p No.5870Q "GiGfN) \ /'ry,1\ RTU-2 1 ROOF TOP UNIT 136 136 rJ, �O ✓Q �� /353 (2 1/2" RTU-3 1 ROOF TOP UNIT 226 226 MARK LOCATION BTU INPUT GAL/HR ® 90 DEGREE RISE STORAGE CAP MANUFACTURER REMARKS Zg G SS�Q EN as I � ( CFN)\> RTU-4 1 ROOF TOP UNIT 226 226 jai u 1111� W RTU (226 CFH) / RTU-5 1 ROOF TOP UNIT 226 226 / WH JAN 40,000 41 40 GAL A. 0. SMITH MODEL: GPDH-40 ' RTU-6 1 ROOF TOP UNIT 226 226Z/��� /k���) \\\ `\Y / * SET WATER HEATER THERMOSTAT TO 110 DEGREES F. 5 \ / 1 // RTU-7 1 ROOF TOP UNIT 226 226 RTU-8 1 ROOF TOP UNIT 226 226 (1'G (Z26/C„G\ / / WH 1 WATER HEATER 40 40 CFN) \\\ FN/� TOTAL = 1645 EXPANSION TANKS The Shops at Evergreen Walk J, \\ // NATURAL GAS SYSTEM SIZED WITH TOTAL DEVELOPED LENGTH FROM GAS METER TO MOST South Windsor, CT \ / REMOTE PIECE OF EQUIPMENT OF 400' WITH A PRESSURE DROP OF 0.5 INCHES W.C. MARK LOCATION SERVES CAPACITY WORKING SIZE (APPROX) MANUFACTURER REMARKS A \\// (GALLONS) PRESS (PSI) Plumbing Schedules, S CED JAN DOM. HW 4.7 150 12"6x12.5" AMTROL MODEL ST-12 Details and Risers 4"G DOWN TO BANK OF METER BY LOCAL UTILITY COMPANY PLUMBING PIPE MATERIAL SCHEDULE a o PIPING SYSTEM ABBREVIATION PIPING MATERIAL a 3 SANITARY DRAINAGE & VENT (ABOVE GRADE) S, W OR V HUBLESS CAST IRON o SANITARY DRAINAGE & VENT (BELOW GRADE) S, W OR V SERVICE WEIGHT CAST IRON P Q GAS RISER DIAGRAM POTABLE WATER (ABOVE GRADE) CW, HW OR HWR TYPE L HARD DRAWN COPPER Checked By: MS o NOT TO SCALE POTABLE WATER - 2" & SMALLER (BELOW GRADE) CW, HW OR HWR TYPE K SOFT ANNEALED COPPER Job No: 06125.00 0 POTABLE WATER - 3" & LARGER (BELOW GRADE) CW, HW OR HWR DUCTILE IRON E NATURAL GAS (ABOVE GRADE & ON ROOF) G SCHEDULE 40 BLACK STEEL 0 NATURAL GAS (BELOW GRADE) G APPROVED 'PE' PIPE FOR GAS F CONDENSATE DRAIN - 1" & SMALLER CD TYPE M HARD DRAWN COPPER oINDIRECT DRAIN - 1"& SMALLER ID TYPE M HARD DRAWN COPPER t7�T!'�U*4ECD OF MCOf0: P201 INDIRECT DRAIN - 1-1/4" & LARGER ID TYPE DWV HARD DRAWN COPPER l.l`IVIIYL.L.I1 i11.1i I11J 3 Duane S . Henderson o REFER TO SPECIFICATIONS FOR FITTINGS, INSTALLATION REQUIREMENTS AND FURTHER INFORMATION 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 6621 M1-1695 m TEL: 913-307-5300 FAX: 913-307-5400 m WEB: WWW.FIENDERSONENGINEERS.COM 0650001687 0 o 0 a a 'c m m m J POWER PLAN KEYNOTES: ❑ ELECTRICAL SERVICE EQUIPMENT: U14 2 1. INSTALL PANELBOARDS, TRANSFORMERS, TIME CLOCKS, CONTACTORS, AND MISC. EQUIPMENT AS N REQUIRED IN GENERAL NOTES, SPECIFICATIONS AND Q REFER TO ENLARGED TEL/COM RISER DIAGRAM. PROVIDE CLEARANCE PER NEC 110- PLAN THIS SHEET I 26(0) I 01 8 E ❑ BACKWRAP COUNTER: N _ _ _ _ _ _ y - - - - - � - - - - - - - - - - 1 -' - mo 1. PROVIDE 20 AMP, 120V, QUADRAPLEX RECEPTACLE - - - - ABOVE BACKWRAP COUNTER AT EACH END. � o IG IG iG 16 / � i '� ,_ c MOUNTING HEIGHT TO BE DETERMINED BY N T / + ( _ L1B-31,33 OWNER/ARCHITECT. L L1-12 1-14 0 / L1A-39 L A-18 L1A n _1-2 11-4 �G ❑3 CASH REGISTER: / I 1. 20 AMP, 120V, QUADRAPLEX RECEPTACLE AT CASH o L1 B-2,4 / / 12 L1B-2 L1, 6 G L -18 L1A-16 \ WRAP COUNTER FOR UTILITY POWER. LOCATE 0 EPTACLE AT CASH Ll-6 r_____________________ ____� i / 10_______ _ BYCOW OWNER/ARCHITECT. RUN 2 #1N2EHWN ADD 1E#12 GIRD (Iku A DIRECTED /E V1 - 16 IIN NDICATED. TO WALL, UP WALL TO CIRCUIT N ----- 2. 20 AMP, 120V, DEDICATED CIRCUIT RECEPTACLE 17 17 13 ®1 13 J (HUBBELL #IG5362) FOR EACH CASH REGISTER. DO NOT I L16-16 INSTALL WITH ANY OTHER CIRCUITS. LOCATE j 12 ----- ---- - ------- -- --J ---- - 16-1 RECEPTACLE AT CASH WRAP COUNTER AS DIRECTED $ L1 - I BY OWNER/ARCHITECT. RUN 2 #12 THWN AND 2 #12 GIRD r------------ ------- ----- r- ------- --------------- ,-_____ _____ _-___ ____ 'd L \ 1-EQUIPMENT GROUND, 1-ISOLATED GROUND IN RIGID L G L1 B 35 37 ( ) L1B- 8 -_� \ A 37 18 / CONDUIT UNDERGROUND TO COLUMN. ROUTE EMT UP L1 B- \ 61 COLUMN TO CIRCUIT INDICATED. -,- I _ - L1A-9 L1-1 I '• 3. DATA OUTLET FOR CREDIT CARD MACHINE. 0 [ L1B 10,12 ; I Lt-19 V NSS IG \ 13 3 COORDINATE REQUIREMENTS WITH N a N o 0 ❑j DIST.BD. "MDP" _i_ .- __-_R_- _ _ -__ -.-- i �- i I- L1B-13 I \ ❑ � Fc � 1 - OWNER/ � .00 H o o - ------ - ----------- - ' r 21 `/ r Lt 41 OWNER ARCHITECT. S w Vo FACP L1A-7 13 4. DATA OUTLET. COORDINATE REQUIREMENTS WITH o v i - - - - - -` - - / L1A- 2 I IG G 13 21 N - - - - - - - - - - - - - - - — - - - - - - — - - - - - p` 7- � - 4 ) ® TELEPHONE BOARD: u b- -- PIGS - ri - - - - - - - - -I � - - - - - - - - z n v L1-21 C Fcl 1. NEW 4'XS' FIRE RETARDENT PAINTED TELEPHONE " v L u n 4 IG BOARD VERTICALLY. y°� o �°0 13 I 2. QUADRAPLEX RECEPTACLE AT 36" AFF FOR M M F' w L1-41, 3 L1B-15 21 21 13 �� L1B-39,41 EQUIPMENT. IG ❑ I 3. MOUNT FIRE ALARM PANEL AND DEDICATED IO L1-23 L1-37 18 CIRCUIT (IF REQUIRED). 4. PROVIDE RJ131X JACK AND POWER FOR BURGLAR - L1=25 I ' ALARM TO PLUG IN WITHIN 2'-0" OF BURGLAR ALARM. C, F761 IF REQUIRED. PNLBD - H1 Li-39 7 5.EXTEND DEMARC TO TEL/COM ROOM IN (2) TWO 2" ❑j PNLBD - H IG '` - -1 CONDUITS. VERIFY EXACT REQUIREMENTS WITH PNLBD - L1 POS / ( L1A-35 COMMUNICATIONS VENDER. 75KVA TRANSFORMER STACKED ON / L1A-33 14 150KVA TRANSFORMER 14 L1A-14 ❑ SHOW WINDOW RECEPTACLE - CEILING: 1. RECEPTACLES AND COVERPLATES WITH AN "SF" PNLBD - L16 DESIGNATION SHALL BE MOUNTED 12" ABOVE PNLBD - L2 21 WINDOW AT STOREFRONT PARALLEL TO STOREFRONT 21 5 ❑1 PNLBD - L 13 GLASS. COORDINATE LOCATION WITH LOCAL PNLBD-LZA ARCHITECTURAL ELEMENTS. CIRCUIT TO PANEL AS LIGHTING CONTROP PANEL - LCP I INDICATED. WIRE THROUGH TIMECLOCK/CONTACTOR. L1A-1 © UNDERGROUND CONDUIT: 13 21 LIB-17 1. COORDINATE WITH SHELL CONSTRUCTION. /��\� ELECTRICAL CONTRACTOR TO VERIFY LOCATION WITH - - - - -- _ - - — - — - - - - - -- - - - - IG - - - - -`; ,- - — - — - - I - - - L18-20 - - - - - — - -} - - - - - - - - — - - - - G - - — - - - ` J J OWNER PRIOR TO START OF WORK. L1 B-19�\ �/21 13 / 7❑ COMPUTER TERMINAL 6�--� 1. 20AMP, 120V., ISOLATED GROUND/DEDICATED L1-8 / CIRCUIT QUADRAPLEX RECEPTACLE (HUBBELL #IG- / \ � I 5362) MOUNTED AT 18" A.F.F. DO NOT INSTALL WITH L1A-11 \\ 21 L1A-2 15 \� Lt-33 ANY OTHER CIRCUITS. RUN (2) #12 & (2) #12 GRID IN 13 L1A-23 21 \\ \\ I SINGLE 3/4" CONDUIT BACK TO PANEL. - � � � DELIVERY BUZZER SYSTEM: 1. PROVIDE AND INSTALL BUZZER SYSTEM AS y, ,� ( ,• ;^ DETAILED IN DELIVERY BUZZER SCHEMATIC. j \ S 9 2 BOLLARDS BY GENERAL CONTRACTOR, CONDUIT RECESSED INTO CONCRETE SLAB BY GENERAL ': CONCRETE SLAB BY G CONTRACT. L1A-27 \ 10 CORDS BY SL GENERAL CONTRACT.IINTO - •1' �' � POWER ASSIST DOOR OPERATOR: 1. PROVIDE UNDERGROUND CONDUIT WITH STUB-UPS f INTO EACH OF THE THREE BOLLARDS AND A J-BOX �FCI WITH PULL STRING FOR WIRING BY OTHERS. VERIFY •, �Y� ( ` I SWING SCAN SENSOR SYSTEM. 2.VERIFY LOCATIONS WITH OWNER AND REQUIREMENTS WITH OWNER'S VENDOR PRIOR TO WORK. SENSORMATIC: 1. JUNCTION BOX WITH CIRCUIT. 13 21 �� u _� dd d 2. .SENSORMATIC WILL REQUIRE A RECEIVER AT THE ❑ / BASE OF EACH OF THE DOORS AND A CONTROLLER yI- II BOX WHICH WILL NEED TO BE MOUNTED ABOVE THE IG SYSTEM. IN THE BACK OF THE HOUSE (EXIT MAN DOOR 1 AND DOCK DOOR MOUNT DIRECTLY ABOVE THE - - — - — - - - - - - - - - — -IG - - - - — - - - - - T - - - - - — - - - - - - — - — - - - - - - G — - - - - - � ) �____ - DOORS. IN THE FRONT OF THE HOUSE MOUNT ON L1A-17 I I 6 I INTERIOR VESTIBULE PLATFORM CEILING, TO BE ..Vf ]6 3.CAB ES FROM THE RECEIVER TO THE CONTROLLER TO BE CONCEALED WITHIN THE STOREFRONT FRAMING PANELS. IG 4.DEDICATED CIRCUIT, 120V, 10, TO J-BOX LOCATED ON CEILING. INSTALL 3/4" EMPTY CONDUITS WITH PULL ;�- -✓ I WIRE FOR INSTALLATION OF SENSORMATIC 5 EQUIPMENT BY OTHERS. INSTALL SENSORMATIC PANELS IN CONCRETE SLAB AND CONDUITS FROM PANELS TO ABOVE CEILING. VERIFY ALL L1A-31 REQUIREMENTS WITH SENSORMATIC MANUFACTURER. I 13 MOUNT RECEPTACLES ® 15' AFF, ABOVE TRIM, AND OUTLETS ATTACHED TO LADDER RACK HORIZONTAL ORIENTED. L1-20 ABOVE CABINETS,TYP.FOR ALL 13 14 MOUNT RECEPTACLES @ 15' AFF, ABOVE TRIM, AND I I 3 I VERTICAL ORIENTED. 20 I �\ L1 B-10•\ ❑11 IG 29 21 14 _ 15 RECEPTACLE LOCATED ON SECOND FLOOR. 3 7 9 11 27 I I 16 DEDICATED CIRCUIT, 120V, 10. TO J-BOX LOCATED ---- i ON CEILING. FOR INSTALLATION OF ALARMEXIT - -- - - - - - -T- - - — G 24 3 19 L1 -8 DEVICE. ALL REQUIREMENTS WITH ` / L1B-19 G 31 h MANUFACTURER. 24 28 22 L1A-5 1 / L1-15 L1A-13 I9 6 i \ / 12 I L1A-29 III 17 BIKE LIFT LOCATIONS, KEEP CLEAR TO 12'-6" WITH 34 L1A-3 L1A-10 L1A-X IG L1A-12 22 220V POWER IN CLG, TYP. - 5 1 _1-13 G l 6 11 5 18 J-BOX WITH DEDICATED 208V, 10 CIRCUIT FOR 30 ^ _ 9 ` Lt-27,29,31 HAND DRYER MOUNTED 48" AFF. COORDINATE EXACT 36 \ 13 2 ' V LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. � - ' � J SF 21 L1A-15 L1 -12 ' � \ I /,�\ 6 - - - - _T- - - - - - - - - - - - - - SF - - - - - - - - - - - -'--It - - - - - - - - - - - - - - - - - - - - , - 3- - - ❑ E J-BOX FOR SECURITY PANEL LOCATION 11 \ INSIDE CABINET. COORDINATE WITH SF 19 32 i 3g -" - fI _ 8 - I' -I OWNER/ARCHITECT PRIOR TO ROUGH-IN. No B Date Description - - - - - - - - - - - - - - I - - - - - - r -' - - - - - -Wpz - - -- - - - - "- - - 20 TELE/COM ROOM: 26 - — - — - - - - - - - - - -I— - - - - II L1-1,3,5 - I- - - L - II I I II II I �I I II ` SHALL WALLSINTHE COVERED WITH 3/4TELECOMMUNICATIONS NIIC TIONSRADE ROOMPLYW L.L. Bean L1-7,9,11 PAINTED ON ALL SIDES AND EDGES WILL FIRE- RETARDANT PAINT. COORDINATE REQUIREMENTS L1-22,24,26 L1-34,36,38 WITH OWNER/ARCHITECT. LEI ITT M Ed Q� [� CLxx1 2.ONE DOUBLE DUPLEX RECEPTACLE PER 6' OF L1-28,30,32 WALL SPACE. A MINIMUM OF (1) ONE DOUBLE DUPLEX RECPTACLE PER WALL. COORDINATE I t REQUIREMENTS WITH OWNER/ARCHITECT. 3.ON EACH OF THE (3) THREE LADDER RACKS, TO ENLARGED TEL COM ROOM PLANTHE RIGHT OF EACH EQUIPMENT RACK, FACING \ THE BACK OF THE ROOM ABOVE THE CABINETS, (1) rnc:a� RDINATE tF ) ® (C.7 ��2 C B ) A $a�4�corv,v� 2 ONE DOUBLE DUPLEX RECEPTACLE FOR A TOTAL OF a� / " �� \' REQU REMENTS WITH(3) THREE COWNERO�RCHITECT. �# ��(''4 00 G: 4. ON (2) TWO LADDER RACKS (#1 & #2), AT THE BASE OF EACH RACK INSTALL (1) ONE DOUBLE m = s;!t DUPLEX RECEPTACLE FOR A TOTAL OF (2) TWO = �"- RECEPTACLES. COORDINATE REQUIREMENTS WITH n °e No.19731 OWNER/ARCHITECT. ELECTRICAL POWER PLAN 5. ON LADDER RACKS (#3), AT THE BASE INSTALL SCALE: 1/8"=V-0" %t,N 0 (1) ONE DOUBLE DUPLEX RECEPTACLE FACING THE BACK WALL. COORDINATE REQUIREMENTS WITH OWNER/ARCHITECT. 21 LOCATE DEVICES FOR TELEVISION PER ARCHITECT AND OWNER. VERIFY PRIOR TO ROUGH-IN. N O O z The Shops at Evergreen Walk s South Windsor, CT a Electrical Power N O o Pan m a 0 a m 3 v b Checked By: OM w 0 Job No: 06125.00 0 0 N O O V 0 O O O F U ENGINEER OF RECORD: E 1 On' 1 3 Craig R . Lanham 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWN.HENDERSONENGINEERS.COM 0650001687 o 0 0 N O O C 0 m J J 0 LIGHTING PLAN GENERAL NOTES: 204 N 1 LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANSI I I I N I - I I I I I 2. SEE.ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT - — - — - LOCATION AND QUANTITY OF LIGHTING FIXTURES. >- - - — - — - — - — - — - _ - - - - - - — _ 3. EMERGENCY AN E ❑Lpj❑g❑❑❑ - - - ___ _�__ __ _ — _ _ D EXIT LIGHTS SHALL BE INSTALLED AND21 - — - CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE ° I I I �❑ L_- AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT - 0 Q I FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) N J� �y it �IC' WOR ROO FE K i WITH BATTERY BACKUP.NL EMPLOYE GE SHOWER RM r L4 L4 L4 I L4 EM L4 NL NL N 4. CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED CEILING Pz` -C4 Z25 L4 •� Z2, =� -r- ___ L4 L4 L4 EM L I PLAN NOTES ON ARCHITECTURAL DRAWINGS. (C E PF, l - H26 Z25 _ Z ❑ _. :.,e•¢t I 5. DO NOT MOUNT LIGHTING DIRECTLY TO ROOF DECK. MOUNT OO M ;______ _ ALL LIGHT FIXTURES ON UNISTRUT RUN BETWEEN TOP L X1 I RES HALL CHORDS OF STRUCTURE OR DIRECTLY TO STRUCTURE. 4 L4 I Xt I � -J x1Mr -------T-------r---------------i-1____ -------,------- _______ X1 6. LIGHTING CONTROL ZONES ARE INDICATED BY 'Zxx' WHERE I Z25 I i - - - t4 ----Z25- L4 i .______ _____ L4 Z2 THROUGH xx' IS HLIGHTI GE ZONE NCONTROLRZZONE ASANDCATEDU PER I LIGHTING CONTROL DESIGNER Z25 L1 �1 1 L4 M N'S RESTROOM H-2 Z20 ' RETURN$ Z20 _ \ j ------- L4 RETU NS ST I _ L1 Z20 L1 Z20 I I B a L4 Z25 I TI CL I o B i Z25 1 11-4 Z25 L4\ EM L4 r — - — - — - - — - — - — - — - — - — — - - — - — - — - — - — ------Ll --- -T-----' o Ll -1B - - - - - - I - - - - - -1A - - - _ Z20, ❑ NL L4 Z25 L4� v N O q g 0 Z20 1 Z20 1 A— EM — - - - Q�� 9 u V Fn A Z20 I P1 \ / O N a H-4 Z23 Z23 I O �� v o v ❑ L4 I I RESTROOM WM N's o• ; 25� L1 -r J F I L1 ;-- 4 Z25 I --Z25 L4 Z r; NIC �� Z20-- ; - P1 Z23 ❑ Z23 EEI P1 I -�--r—r H-6 MONOGRAMMING RM 20 t I,M�,�� � L c/ I � (�/�H-1 ,_ `Y,^' ) .Y.""�> Z21/Z22 L1Pi 1 I f EM P1 EM Z20 L1 ��;�,�..����EM V NL I EM P1 1 �Cf X1 NL I f— Z20 A NL IEM H-12 I i X1Ll l — - — - — - - -Z20 - - -` - - - Z23 _ - - - - - —� `� � � � I _ - EM ❑ I l�J - 3 NL V V Ll Z20 ---- P1 f H-8 EM I ?C, Z2C Z23Pi 224 ; Pi A NL � PlA LLLJJJ I �-- I y) Z24 Gil r L P1A \ i L-NPL�A L � j EM r , I � � �J I -J L�J L1 , Qj `-J I 24 v r i r�j, Pi I "s� L 'L t� I Z23 I j NL P1 I - L1 -, r- r ill L� EM I t' e,2 I - Z � I I O T", I Z2D L L J P A NLA P1 - 8 -X EM J ,.I I L1 _ I P1A NL I Z24 ) r P1A P14 I I I Z24 Z24 i z20 L--- __ �-j� — I � I I 1?( � P1A I R1a �I-�—�, •- z2o Z23 1 t1 x1 P1 M P1 Z2 724 V Z24 E I 4 I I - E Z23 P1A X1 Li NL —J - - --r - - - P1 —Z24 _ c ) c ! I - - - - - - - - - - - - �� - - - - - - - - - - - - �J _. NL Pi EMLl Pi \ - - - - - - � Z20 r Z24 I rr l� �/� \ Z2C EM P1 Pi C NL EM Pi NL Xl PZl 101A Z23 r ` V/ p1 YJ Z23 r L1 P1 I 4 Z24j[ P 3 OO I ' EM L L1 20 a ,- ' 23 V, Z20 I r ' 1 J X1 ) EN'S FITTING ROOM .-' J I Lt V L1 Ll L j IZ23?{ I Z20 Z20 1j�1 P1A Pi P1A o� f " Z20 I CASE� Ll NL EM NL EM I %cl�f! EM Y L1A L-- � EM I l 1 Z20 ! ' Lt EM M L I � Ll � � I r , y, � Z23 I ZLl NL ;' NL t\r L1 5� ILI Z23 �0 —X7 t •� ., Z20 Z20 y __ , -T -T - Z20 v x1 , r r j p T T i 1 11 ❑ - ' r---r —r---1 1 - - O CASH WRAP CLST' I ' ' Z20 L1 I N — - — - — - - eo— - - - - - - - - - - - - - - - -0 - - - - - - L1 Z20 g❑ C3 -VEST B II G __ ___ NL E i 03.13.07 REV.PER TOWN COMMENTS — � T T -I -T T -1 T _T _ — ® 02.20.07 ADDENDUM �A - 02.16.07 ADDENDUM — - — - — ----- -----------_—_-- PERMIT--_- — - — _ - — - KV 02.1 .07 ISSUE FOR PERM - --r - - - - - - - - - - - - - - - - - - -�— - - - - - - KV 02. .07 ISSUE FOR BID 17 -r- — - — - -- - — - — - — - — - — - — WOMEN'S ITTING ROOM No By Date DescAption I , IQ I I I L.L. Bean MAR 1 q 2007 D South Windsor F BUILDING D TMENT Aq. UPPER LEVEL ELECTRICAL LIGHTING PLANTFS•:�€SSE 1 ems! raaC a `. `' SCALE: 1/8"=1'-0" N S /Z-4� The Shops at Evergreen Walk 75 Tamarack Ave Building C, Suite 75 South Windsor, CT 06074 Electrical Lighting Plan, Upper Level I Checked By: OM Job No: 06125.00 ENGINEER OF RECORD: Craig R . Lanham E102 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0650001687 U d I I I I N OFFICE: OFFICE I QUN MGR. SUPPORT SAFE TEL/ I STAFF T I , I ' COM VENbING MACHINE/ LOUN E E - - - - - - - h __.-_� - - - - --_� - - - _-_ " _ LIGHTING PLAN GENERAL m _1 _1 / , I _1 1. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON I 05 I ✓ I G N i H-19 R1 R1 R1 R1 R1 R1 t} c R1\ R1 �ZT� — STAFF RESTROOM PLANS. L 2. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT a / I Z18 -18 F LOCATION AND QUANTITY OF LIGHTING FIXTURES. °J U5 — �- - - 2 O ZLLL Z _LLj// ��/////%� � ;__-- os Z17 1 os 6 Z15 - --- ` �/ Z1 X1 3. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND � / /\ M REGRESS CORRIDOR CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE UP AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) Zj3 J O Z83 Rj WITH BATTERY BACKUP. I-------T---------------•------- --------- T-------*-------T------ EM ®�� ------_"---- ------ "'---- 4. CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED CEILING ® I ��'I _ W 3 I - PLAN NOTESON ARCHITECTURAL DRAWINGS.LE __ `---'- -'---`---'--`---'-- ---=--`---`-I-----`- NL EM X _ EM NL — 5. DO NOT MOUNT LIGHTING DIRECTLY TO ROOF DECK. MOUNT \ Z 3 ZM , ALL LIGHT FIXTURES ON UNISTRUT RUN BETWEEN TOP Z10 R3 Z13 R3 EM R3 M E S ROOM Z13 NL CHORDS OF STRUCTURE OR DIRECTLY TO STRUCTURE. o H r _ �. RE7 dVS I ` ;'. I —, -- 1 I UT ITY ROOM s N B �L� N R2 I R3 I- �CC LS L 2 -�- LI- - s� \ I 05 -1- — - — - - --j- - - - - - - \ - - - _r - - - -�[Q- - - - - - - - , - - - - - - - - - - - - - -II - - - - - - - - - _ - - �Z— - O - - � - ; — - - —1 L�. ' u Tu rl�n so \ ✓� H-17 (� DN I �8A�Z11 R3 - ZR3� n o x d �' ❑ \ I J NL a� w � a� aw 5 EM MEWS ROOM 11 EM N IEXISTI ="" �) _ R1 w e - z,� , I R I — MONOGRAMMING GROOM I I , CLOSE XV - -II \\\// - R, I t tl -I J '1- TT 'T -I I ✓� ` H-15 �Zz�� � //EM_L ' \\\ \ UP / Imo; Z9\ Q ; I- I `-- 1 — EI I f J r r T LJ J NIL 1311E �1�' I 'ry4 - hr j SHOP � 8r � , IL �y�` t-� r g pl �\ ✓ rJ LJ �j \I , I �\ l N 1 , '� `-fS�1'•_.f4_ '` L J J _ 2) _ f J � I .; _ S L1A-30 � ; ' L j ;Jv ' � I H-1 M E N'S P3 ��\ '/ �l I �'AS H W RA!— S 1 Z13 �\ ZJ FITTING H-7 s, >� _ RM W4 Z6 \ j S Z4 Z4 j g7 ^ LS Z7 L- Z� LS—Z� L5 Z Z5 H-3 - _ s Z4 L6 L6 VE r j�e- 3 Z4 L6 Z3 ��l SALES ( Q W4 W4 W4 W4 w4 Z5 , 1 z L6 z3 / FLOOR I 81 Z8 z8 z Z W4 Z6Z L5 L J �;t H-5 Z L6 L6 Z3 Z3 W H-9 ZS WOMEN'S <y > Ef 9 Ls FITTING RM Z6 3 W34 � 8 H-11 r P3 Z8 Z8 Z8 Z8 Z Z4 L— Z3 . 1 W4 6 W� — I---,--r---� , - --------- -----j:---,- .---.--- L7 �� I W3 I W4 W4 W4� W4 Z L5 — _ � l � � P2 Z2 I �------L5 Z5 T - - - - - - - '= - '- — - - - — '-� I- Z2 - — P2 - ,I 1 �-.---.- ,---. - ---, I--r--- L5 L 7I L L- � I X1 X7 I' - —1 - - - - - - - - - - - - — - - I - - '- -�d� -I� U—�,�I� No B Date Description H-21 Z, Z, Z, Z, Z, Z, Z, - �� _ -- - Z1 - - - IZ� - - -2, - - - Z, - - - Z - - I �I II II III I��I -�� Il- - - - L.L. Bean P2 P2 P2 P2 P2 P2 EM 2 EM P2 EM P2P2 P2 P2 P2 I NL NL NL � � ;m I I I I I I J ffxfl E C 7 C.2> C �B J o��vnr�..3. 4 D,Io+oacaeso t�,'pae LOWER LEVEL 3 ELECTRICAL LIGHTING PLAN � U SCALE: 1/8"=1'-0" N0. 1 5731 a 0 m i a T L The Shops at Evergreen Walk Y South Windsor, CT m 0 Electrical Lighting a Plan, Lower Level a rn 3 9 m O W n Checked By: OM 0 0 Job No: 06125.00 m w 'o 0 0 F ' U m` c 3 ENGINEER OF RECORD: E103 N Craig R . Lanham m 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 F1, 0 WEB: WWW.HENDERSONENGINEERS.COM N 0650001687 m a 'c m m m J J_ 0 I UM4 LIGHTING PLAN GENERAL NOTES: ca 1. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON A X o I I PLANS. t`C'it OFFICE I WORKROOM SAFE RM EMf�LOYEE LOUNGE I 2. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT i I I I I LOCATION AND QUANTITY OF LIGHTING FIXTURES. m E 21 3. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND ) IF G AL E ----------------------- ------ R1 os -- - - -- 1 I :J AND ALL L LL EMER E EXT N ��❑�❑❑❑ / I I 1 1 R1 Za4 FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) H_lg WITH BATTERY BACKUP. rn 1 SHOWER RM _ 14 os os 4. CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED i CEILING PLAN NOTES ON ARCHITECTURAL DRAWINGS. U 16 QQ os Z1 i os Z1 Z15 X11 X2 1 5. DO NOT MOUNT LIGHTING DIRECTLY TO ROOF DECK. L MOUNT ALL LIGHT FIXTURES ON UNISTRUT RUN BETWEEN ZHLILI /p"Ll 1 e B TOP CHORDS OF STRUCTURE OR DIRECTLY TO STRUCTURE. R ESS HALL EN'S R Z�SJ � Z83 E 6. LIGHTING COT ZONES ARE INDICATEDZxx' WHERE M ESTROOM O xx' IS THE ZONE NUMBER. ROUTE BRANCH YCIRCUIT r ' *-------T-------T ------ 7 LIGHTING LIGHTING CONTROL ZONE AS INDICATED PER WS THROUGH J r---- ------- ------- ------ r- - I - 7 LIG CONTROL DESIGNER. - L_ I___,___L___.___L___,f- 5 'NL X1 I PROVIDE REMOTE BATTERY PACK (BODINE B84C) WITH TEST , 1 - EM EM NL Lj SWITCH AND INDICATOR LIGHT, MOUNTED IN ACCESSIBLE 3 R3 EM R3 LOCATION, INSIDE TENANT SPACE FOR WALL MOUNTED a Z10 RETUR S L T 0 Z13 - NL EXTERIOR LIGHT FIXTURE. 8 L UTI (lf C - S ETURNS ; L R2 R3 � 1 r, ❑ NL Z 2 ft31 1j q — - — - - - _91 - - - - y` 05c I C � 6q °�' � :- - - G MO c�RAMMUA RM R3I N'S RESTROOMw° a w H-17 , I I Z1 t EM I ❑ I - I� -r, ' ( � F 'I J J R1 � 1 R3 NL R3� o n O Ly _ u ' u ' �j--=- ) 1� �Yr-r�1 -- �1--ter— TT — TT LLL__,IILIJ " LLLLLLJJJ H-15 -� `✓^\ T�7 ~ r JI �aF—J L—J L -1 I1 LKE SHOP oy `^ ^ IL LJ LJ L! L.1 LJ I _ i - U`------lU ill LTLJ LrLJ r , - L1A-301-1 f'11111�, �,1. y�Cv/� J I gggGn¢avc➢> H-1 O•'/jam-�(. No. 19731 °°°N ENS FITTING ROOM e , z5 � s�i I ��i H-7 1�H5}i Vltr�ibi S 1 , '' I � � -- - � i P3 L ! I L J S1 Z4 Z5 �' l 51 Z4 L6 % Z I L5 S1 Z4 //�f W ° I W , \ S1 Z4 NL < / �' Z7 Y7 7 Z7 i 7 Z7 L5 e L -5 Z4 EM - --i- - J L5 L5 LS LS Z5 L5 Z4 N Z 4� i I I ; I N Z I VESTIBULE L5 1 r , 3 W1' D P3 Wo11�EN'S FITTING ROOM L5 ' W4 <"�, I L5 ZS I I I I Z7 - - H- - W3 Z ( 03.13.07 REV.PER 4 L6 L6 Z Z YIW Z3 11 - 02.20.07 ADDENDUM TOWN COM /� Z7 L L Z5 W 0 Z3 I EM P2 P2 EM g !// /// Z7 Z7' 7 Z7 , ""��//// W4 I W4 , W4 AA - 02.16.07 ADDENDUM Z5 L5 L5 r---T--r-- NL NL -r---r---, r r —Q - _ - - - _ — _ — _ _ — - _ - - KV 02.13.07 ISSUE FOR PERMIT X1 — X1 KV 02.09.07 ISSUE FOR BID CASH WRAP CLST No B Date Description — - - - - - - - — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 H-g Z1 Z1 Z1 Z1 Z1 Z1 - - - - - - - - - � - - - Z1 Z1 Z1 - - - Z1 - - � - - — � — - � L.L. Bean P2 P2 P2 P2 P2 P2 NEM L I2 EM NL P2 NM P2 P2 P2 P2 P2 7 I HAR 1 4 ZUU' D �+ p South Windsor F E D C.7 C.2 C B A BUILDING DEPARTMENT LOWER LEVEL ELECTRICAL LIGHTING PLANcm 1 SCALE: 1/8"=V-0" N The Shops at Evergreen Walk 75 Tamarack Ave Building C, Suite 75 South Windsor, CT 06074 Electrical Lighting Plan, Lower Level Checked By: OM Job No: 06125.00 ENGINEER OF RECORD: El 04 rEf Craig R . Lanham 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0650001687 GENERAL NOTE: Ui 1. COORDINATE ALL TELEPHONE AND DATA SYSTEM � POWER AND DISTRIBUTION REQUIREMENTS WITH 3/4' OWNER'S TELECOMMUNICATIONS VENDORS. m 3/4"C 3/4"C 3/4"C 2. ALL EQUIPMENT SHALL BE NEW AND LISTED BY AND BEIQ) I 2"C 2 VENkING MACHINE APPROVED BY A TESTING LABORATORY AND SHALL BE 2"G INSTALLED AS PER INSTRUCTIONS INCLUDED IN THE E I I I � � I � ' i I FINISH WHERE APPLICABLE._ _ _ — _ _ _ � _ _ _ _ _ TCH EXISTING TYPE AND m cp -- -- - __ 3. L.L. BEAN REQUIRES THE ELECTRICAL CONTRACTOR TO N !OI FFIC�: STAFF STAFF RESTROOM OFFICE I' PROVIDE CABLE PATHS FROM THE MAIN DISTRIBUTION r I �- I <— FRAME (MDF) TO THE TELECOM ROOM, AND FROM A �' - GR. SUPPORT SAFE TL LOUNGE 1 WORKBOX AT EACH OUTLET LOCATION TO THE NEAREST 4"C 3/4"C REF. ACCESSIBLE CEILING. CABLE PATHS SHOULD BE SIZED BY _ OF THE _______i____ AREATHEATOHBECSERVED,RDING THE SIZETHE ANDDENSITY NUMBER OF THE 3/4"C <I MER EGRESS CORRIDOR CABLES TO BE RUN, AND THE FILL RATIOS OF THE - .. - `- � I I ; _ INTENDED PATHWAY. REFER TO DIV. 17 SPECIFICATIONS. UP / G G / G 4. IE ' -r---__ OUTLETS. ES AND CONDUIT FOR THE COMMUNICATIONS 3 4 I THE CAL CONTRACTOR SHALL PROVIDE ALL — — \ 3 4" BACK BOXES - - TELEDAT SYSTEM PLAN KEYNOTES: I If I ' ll FACP ( I \ {^ - I MEWS ROOM ❑1 TELE/DATA MOUNTED AT 2'-6" AFF TYP FOR DEVICES ON v TVSS �°T®�K BACK WALL OF CASH WRAP. o 1 DIST.BD. "MDP" R®® 3/4 C \ — UTILITY ROOM ❑ 2 " ❑ �- RETu��s r i / 2 TEL COM ROOM. o N o o u 3 d p v N N \ r ❑3 MOUNT TELE/DATA OUTLETS IN CEILING. b v - — - — - — - — - — - — - — - — - —U vp0 v\ n p 6B 3/4„C DN ¢� �, ° a m w B i I ��=. �� (— WOMEN'S ROOM / 2"C (/2"C / MONOGRAMMING ROOM PNLBD — H1 A-Li (J ❑1 PNLBD — EM 3/4"C PNLBD — L1 150KVA TRANSFORMER ST PNLBD — L1A PNLBD — L1 B C / 2 C ❑1 PNLBD — L2 (� _T PNLBD—L2A LIGHTING CONTROP PANEL — LCP 3/4"C 3/4"C 3/4"C _ — — - - - F� - - - — - - - — ' - — - - - - -�I - - - - - - - - - -I - - - - - - - - - - — - - - - - - — -- - - -� 3/ "C �� v UPI BIKE \, SHOP it � / `\lx�Ky4� I I DN Oil � F. I -� I!-. I •�t- - I I /4 C I ' ' 3/4"C - — - — - - - - - - - T - - - - - - T- - - - - - - � T (� - I _ - - I I I 3/4"C 3/ "C I I I I I I i I I I I I I I I MEN'S FITTING \� F`M SALES a ®/� 1 FLOOR CASH WRAP �I,� I I I WOMENS FITTING RM 3{4 I. f — I � 2 C \\ /I 3� 3/4 C �V I� - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3/4"C - I 1"C 1 _�- _ _ - - - _ - - - - - - - - - -- - - - - - - - - -�J I I r r (,I 2"- 4°C LI L� No B Dale Description - - — - - - - -- - — - - -- - - - -,� - - I- �/` 7777f - - ��] -- - - -- - - - - -- - - - - � _ �_��-_,.�.L��II-11 III III g L.L. Bean I - _� i I I 3/ "C Y`(as�F3. LN`iILq Q2/� � -'�a No.1D731 TELEDATA SYSTEMS PLAN SCALE: 1/8"=1'-0" S-� 7 N O O 0 D T The Shops at Evergreen Walk South Windsor, CT a m N TELEDATA SYSTEMS PLAN a 0 a d, 3 v N O m Checked By: OM 0 ,lob No: 06125.00 0 m w s 0 F U ENGIIVEER OF RECORD: E105 3 Craig R . Lanham m° 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0 0650001687 0 0 n o I 'c m m m J J_ 0 ONELINE DIAGRAM KEYNOTES: r N ❑1 PROVIDE LIGHTING CONTROL PANEL "LCP", UL LISTED. PANEL SHALL BE SPECIFIED PER LIGHTING CONTROL DESIGNER. EXISTING - - UTILITY TRANSFORMER EXISTING 480Y/277V, 30, 4W SEC 42,0 OA >> rr �� �� D AVAILABLE FAULT CURRENT S E S M D P ( PER UTILITY COMPANY 1200 AMPS 800 AMPS N 480Y/277V 3PH 4W 480V277V 3PH 4W z 42,000 AIC RATING BUSSED FOR 42,000 AIC RATING rn o (12) 4"C. SERVICE ENTRANCE RATED FUTU SERVICE ENTRANCE RATED CIRCUIT SCHEDULE: a I NEMA 1 NEMA 1 ALL CONDUCTOR SIZES ARE BASED ON _ 75 DEG C RATED TERMINATION AND COPPER T - — - - - - — - - — - - — - — - - CONDUCTORS WITH TYPE THHN/THWN-2 I I - - - - - - - � � INSULATION. 34 30A, 4 10, 1 10G, 1 2" C 153 150A, (3)#1/0, (1)#6G, 1-1/2" C EXISTING EXISTING I 223 225A, (3)#4/0, (1)#4G, 2" C MAIN 1200A BUS (FULL LENGTH) I 800A BUS (FULL LENGTH) 1000A i 224 225A, (4)#4/0, (1)#4G, 2-1/2" C 3P EXISTING EXISTING C 30A / 400A / 400A U FUSES EXISTING 100A FUTURE \ 3P \ 3P \ 3P 404 400A, (2) 2" C, EACH W/ (4)#3/0, (1)#3G o c M M 804 800A, (3) 3" C, EACH W/ (4)-300kcmil, (1)#1/OG ° o .� 0 u EXISTING EXISTING G500 GND, #1/0 COPPER GROUND, 1" C qj n 80OA/3P 10OA/3P \ FUTURE u 6 I G800 GND, #2/0 COPPER GROUND, 1" Ccr 5 v IL] i Uq Wv r v EXISRNG LGT PROVIDE NUMBER OF CIRCUIT AS REQUIRED S o " .n I NEUTRAL BUS I I a •� T • I PRIMARY EXISTING UTILITY CONDUCTORS v w w EXISTING - - GROUND BUS - - - - SECOND EXISTING UTILITY CONDUCTORS - - - - - - - -- - - - - 0 0 o T254 250A, (4)-250kcmil, (1)#2G, 2-1/2" C ao m m EXISTING d o o T255 250A, (4)-250kcmil, (1)#2G, (1)#2 IG, 2-1/2" C M, � � TO MAIN TELEPHONE EXISTING F1 BOARD PNLBD - CH F2 F3 F4 EXISTING TO COLD WATER - SERVICE, FIRE WATER = SERVICE, BUILDING TVSS STEEL, GAS PIPING m EXISTING z 20' MINIMUM LENGTH-7a- CONCRETE ENCASED = ELECTRODE LGT 0 m J Z n. 804 IF F11 5 FS Fil ONE LINE DIAGRAM — "SES—C" 75KVA 11 5i T151150KVA NO SCALE 48OV, 3PH, 3W PRI AF7 3PH, 3W PRI 208Y 120V 3PH, 4W SECL_ ___ 20V 3PH, 4W SEC PRO IDE DbUBLE LUGSE DbUBLE LUGS o .rF8F9TENANT ELECTRICAL SERVICE LOAD SUMMARY TENANT OCCUPANCY TYPE: M SERVICE DESCRIPTION: TENANT SQUARE FOOTAGE: 25,000 480Y/277V, 3PH, 4W LGT LOAD DESCRIPTION Connected Demand Demand KVA I FACTOR KVA 224 F10 HVAC - SUMMER 169.17 90% 152.25 HVAC - WINTER 169.17 90% 0.00 m LIGHTING (PER NEC-220) 75.00 125% 93.75 J J J J J RECEPTACLES 21.42 100%;50% 15.71 0 0 0 0 0 KITCHEN EQUIPMENT 0.00 100% 0.00 m m at m m MOTOR LOADS 11.41 100% 11.41 a- a a- a- a LARGEST MOTOR LOAD 0.53 125% 0.66 SUPPLEMENTAL ELECTRIC HEAT 11.00 100% 11.00 MISCELLANEOUS EQUIPMENT 35.76 100% 35.76 DISPLAY CASE/SIGNAGE 0.00 125% 0.00 SHOW WINDOW / TRACK LIGHTING 75.80 PER NEC 77.88 NEW WORK EXTERIOR LIGHTING 0.00 125% 0.00 TOTAL LOAD 569.26 KVA 1 398.42 TOTAL AMPACITY 684.711 AMPS 1 479.22 SERVICE AMPACITY 8001 AMPS 1 800.00 SPARE CAPACITY I AMPS 1 321 Short-Circuit Calculations The following calculations are based on the Point-to-Point method where: All calculations utilize copper conductors Three Phase: or Single Phase: Transformer. Isc = Isc x M M= 1/(1+f) f = x_ L_x l f =2 x LXI f =1P(sco)x Vp x%Z IS(sca)= Vp x M x IS(sca) C �- C E 100,000xKVA Vs Source Fault Panel (Fault Source I Conduit X'FMR X'FMR Point Point) ((amps) Type Wire Bus Size 'C' value E volts L len th KVA Z f M ISC 1 MDP SES 42000 1 NM 3 Set s of 300 KCMIL 20867 480 1 26 - 0.063 0.94 39511 2 TV SS 1 395111 M 1 Set s of 10 981 480 15 - - 2.180 0.31 12425 3 H 1 39511 M 2 Sets of 3 0 12843 480 20 - 0.111 0.90 35563 4 H1 1 39511 M 2 Sets of 3 0 12843 480 15 - - 0.083 0.92 36483 5 T750 PRIMARY 3 35563 M 1 Sets of 4 0 15082 480 5 - 0.043 0.96 34097 6 L1 T150 SECONDARY 5 34097 M 1 Sets of 250 KCML 12843 208 5 150 5.3 0.021 0.98 6417 7 L1A 6 6417 M 1 Sets of 4 0 15082 208 10 - - 0.035 0.97 6200 8 L1B 1 35563 M 1 Sets of 250 KCML 15082 208 10 75 5.3 19.71 0.05 3434 9 L2 5 34097 M 1 Sets of 252 KCML 15082 228 15 150 5.3 9.449 0.10 6526 10 L2A 9 6526 M 1 Sets of 4 0 15082 208 20 - - 0.072 0.93 6088 11 LCP 3 35563 M 1 Sets of 10 981 277 30 - - 6.800 0.13 4559 No By Date Description L.L. Bean �Iy L,U4,P'(4(ie�•� 's9y Gw i U'Q.m. No. 19731 � v 0 � fC irc`O eoG�oo z�7 S L' The Shops at Evergreen Walk South Windsor, CT a N p Electrical One Line Diagram, Fault a Calculations, Load SummarV w Checked By: OM m 0 Job No: 06125.00 a m W 'o o i 0 F U ENGINEER OF RECORD: E201 3 Craig R . Lanham t rn 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 ^m WEB: WWW.HENDERSONENGINEERS.COM m b 0650001687 I o N b O C m 0 i m J_ �I r] C UOO Q T N E OI N W I O O N L Ol .0 T 0 rn ,ems CJ I a ctl bO yN. r A y, WV n L 0 i I i I PANELBOARD: H (NEW) FAULT CURRENT: 35563 A EQUIPMENT GROUND BUS PANELBOARD: H1 (NEW) FAULT CURRENT: 36483 A EQUIPMENT GROUND BUS BUS AMPS: 400A AIC RATING:65,000 FULLY RATED BUS AMPS: 400A AIC RATING:65,000 FULLY RATED MAIN SIZE/TYPE: MLO SERVES: MAIN SIZE/TYPE: MLO SERVES: VOLTS/PHASE: 4BOY/277V, 3PH, 4W MOUNTING: SURFACE VOLTS/PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION: i LOCATION: STORAGE ROOM SECTION: 1 LOCATION: STORAGE ROOM CKT DESCRIPTION VOLTAMPS PHASE WIRE BKR P P BKR WIRE VOLTAMPS PHASE DESCRIPTION CKT CKT DESCRIPTION VOLTAMPS PHASE WIRE BKR P P BKR WIRE VOLTAMPS PHASE DESCRIPTION CKT NO. A B C NO. AMP AMP NO. A B C NO. NO. A B C NO. AMP AMP NO. A B C NO. 1 LTG-MENS FITTING ROOM 1,000 %/ / / 12 20 1 1 20 12 2,592 /// /// LTG-STOCKROOM,EM 2 LK 1 RTU-1 3,629 % //� %/ / 8,033 ////// %///// RTU-8 2 3 SPARE %/// /// 20 1 1 20 12 // 1,863 / LTG-SALES 1 4 3 �// 3,629 ////i 10 20 3 3 40 8 ///� 8,033 /// 4 LK 5 LTG-CASH WRAP 1,EM W /// // 1,000 12 20 1 1 20 12 / / % // 1,664 LTG-SALES 2 6 5 /// //� 3,629 %///// %// 8,033 6 7 LTG-CASH WRAP 2 1,000 %//// %/ / 12 20 1 1 20 12 1,536 // /// LTG-SALES 3 8 7 RTU-2 5,983 %///// %/ / 1 20 10 3,000 %/ ///// U H-1 8 LK 9 LTG-ENTRY,EM //// i 1,025 %//// 12 20 1 1 20 12 /// 1,920 %///i LTG-SALES 4 10 9 /// 5,983 %/// 10 30 3 1 20 10 ///// 4,000 /// UH-2 10 11 LTG-WOMENS FITTING ROOM %////� % /// 1,000 12 20 1 1 20 12 %//// %//// 1,664 LTG-SALES EM 1 12 LK 11 /// // 5,983 1 20 10 //// %/// 4,000 UH-3 12 13 SPARE ///// %/ / 20 1 1 20 12 1,792 %//// ////i LTG-SALES EM 2 14 LK t 13 RTU-3 8,033 �/ / %/ / 1 /// / SPACE 14 LK 15 LTG-BIKE SHOP,EM %// 1,000 // 12 20 1 1 20 %//// % /// SPARE 16 15 �// i 8,033 %/// 8 40 3 1 ///// /// SPACE 16 17 LTG-RETURNS // /// 1,000 12 20 1 1 20 / /i %/// SPARE 18 17 //// //� 8,033 1 %//i%///// SPACE 18 LK 19 LTG-BACK SUPPORT AREA,EM 3,000 %/ / /// / 12 20 1 1 20 //// %// SPARE 20 19 RTU-4 8,033 % ///%/ / 1 %// SPACE 20 21 SPARE / // 12 20 1 1 20 //// // SPARE 22 i i 21 /// 8,033 /// 8 40 3 1 // / SPACE 22 23 SPARE % // /// 20 1 1 20 % //% / SPARE 24 i 23 / 8,033 1 /// SPACE 24 25 SPARE / 20 1 1 20 / / SPARE 26 25 RTU-5 8,033 /i 1 / i SPACE 26 27 SPARE % 20 1 1 20 //// SPARE 26 i 27 / / 8,033 / � 8 40 3 1 // / i SPACE 28 29 SPARE �� / 20 1 1 20 / / SPARE 30 29 %/// "j/ " 8,033 1 j/ SPACE 30 31 PNLBD L1 B 6,987 / % / 1 20 �// / SPARE 32 i i 31 RTU-6 8,033 / // 1 � / SPACE 32 33 VIA TRANSFORMER / / 8,727 /// OL 125 3 1 20 // / // SPARE 34 33 % 8,033 / B 40 3 1 �// SPACE 34 35 %// / 6,891 1 20 % // % SPARE 36 35 %/// i // 8,033 1 /// / / i SPACE 36 37 TRANSFORMER T150 19,051 / i 1 20 %// i /// i SPARE 38 37 RTU-7 8,033 /i // 1 %/// // / SPACE 38 39 SUB FEED BREAKER % / 18,602 // OL 225 3 1 20 /// /// SPARE 39 i 8,033 8 40 3 1 /// i // SPACE 40 i /// i 18,426 1 20 ////// /// SPARE 42 41 //// ///� 8,033 1 % // / SPACE 42 SUBTOTAL 31,038 29,354 28,317 5,920 3,783 3,328 SUBTOTAL SUBTOTAL 49,777 49,777 49,777 11,033 12,033 12,033 SUBTOTAL TOTAL PHASE A - VA 36,958 LOAD CONN. VA DF LOAD CONN. VA DF TOTAL PHASE A - VA 60,810 LOAD CONN. VA DF LOAD I CONN. VA DF AMPS 133 COOLING 1,306 1.00 REFRIGERATION 1.00 AMPS 220 COOLING 181,463 1.00 REFRIGERATION 1.00 TOTAL PHASE B - VA 33,137 HEATING 1,306 0 SIGN/DISPLAY 1.25 TOTAL PHASE B - VA 61,810 HEATING 181,463 0 SIGN/DISPLAY 1.25 AMPS 120 LIGHTING 25,450 1.25 KITCHEN 1.00 AMPS 223 LIGHTING 1.25 KITCHEN 1.00 TOTAL PHASE C - VA 31,645 RECEPTACLES 18,000 1.0/.5 EXISTING 1.00 TOTAL PHASE C - VA 61,810 RECEPTACLES 1.0/.5 EXISTING 1.00 AMPS 114 MOTORS 13,904 1.00 LARGE MOTOR 1.25 TOTAL DEMAND AMPS 223 MOTORS 1.00 LARGE MOTOR 1.25 TOTAL DEMAND TOTAL PNLBD - VA 101,740 SUPP HEAT 1.00 SHOW WINDOW 8,300 1.25 190,678 VA TOTAL PNLBD - VA 1g4,430 SUPP HEAT 11,000 1.00 SHOW WINDOW 1.25 192,463 VA AMPS 122 MISC EQUIP 43,080 1.00 LTG TRACK 76,200 1.00 229 A AMPS 222 MISC EQUIP 1.00 LTG TRACK 1.00 231 A PANELBOARD NOTES PANELBOARD NOTES LK-LOCK CIRCUIT BREAKER IN THE SON' POSITION OL-SEE ONE LINE DIAGRAM LTG TRACK - TRACK LENGTHI LTG TRACK - TRACK LENGTH SIGN DISPLAY - SIGNAGE & DISPLAY CASEI SIGN DISPLAY - SIGNAGE & DISPLAY CASE - 03.13.07 REV.PER TOWN COMMENTS ® - 02.20.07 ADDENDUM AQ - 02.16.07 ADDENDUM KV 02.13.07 ISSUE FOR PERMIT KV 02.09.07 ISSUE FORBID No B Date DescripBon L.L. Bean E C E � w E 0 MAR 142007 South Wlndnor BUILDING DEPARTMENT of ON P.d�OP.L,1 N0. 19731 c a uu°a X-/z•d7 The Shops at Evergreen Walk 75 Tamarack Ave Building C, Suite 75 South Windsor, CT 06074 Electrical Panel Schedules Checked By: OM .lob No: 06125.00 ENGINEER OF RECORD: E202 Craig R . Lanham 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: WWW.HENDERSONENGINEERS.COM 0650001687 PANELBOARD: L1 (NEW) BUS AMPS: 225A FAULT CURRENT: 6417 A MAIN SIZE/TYPE: 200A MCB AIC RATING:10,000 FULLY RATED EQUIPMENT GROUND BUS PANELBOARD: L2 (NEW) VOLTS/PHASE: 20BY/12OV, 3PH, 4W SERVES: ISOLATED GROUND BUS SECTION: 1 MOUNTING: SURFACE FEED THRU LUGS BUS AMPS: 225A FAULT CURRENT: 6526 A LOCATION: STORAGE ROOM MAIN SIZE/TYPE: 200A MCB AIC RATING:10,000 FULLY RATED EQUIPMENT GROUND BUS CKT DESCRIPTION VOLTAMPS PHASE VOLTS/PHASE: 208Y/120V, 3PH, 4W SERVES: N0. WIRE BKR P P BKR WIRE VOLTAMPS PHASE FEED THRU LUGS v A B C N0. AMP DESCRIPTION SECTION: 1 MOUNTING: SURFACE IG 1 RCPT - POS #1 AMP N0. q g C CKT LOCATION: STORAGE ROOM IG 3 RCPT - POS #2 1,200 %// ///� 12 20 1 1 20 12 720 i NO. CKT DESCRIPTION VOLTAMPS PHASE WIRE BKR P P BKR WIRE VOLTAMPS PHASE � 1,200 %////� 12 20 1 1 ////� RCPT - STOCK N1 NO' A B IG 5 RCPT - POS #3 4 1 LTG-TRACK-1 C N0. AMP AMP N0. q DESCRIPTION CKT IG 7 RCPT - POS #4 12 � i g C /////� /////� 360 UL RCPT - STOCK W7 6 3 LTG-TRACK-2 , 39 IG 9 RCPT - POS #5 1,200 /////� //� 12 20 1 1 20 12 720 i ////� 39 ///// %//// SPARE E 1,200 ////// ///// RCPT - COLUMN E 5 LTG-TRACK-3 , ////� 10 20 1 1 20 i y E IG 11 RCPT - POS #6 / %////� 12 8 RCPT - STOCK ROOM CPU 10 IG 7 LTG-TRACK-4 // � / /// SPARE RCPT - OFFICE MGR 9 LTG-TRACK-5 , 39 ///� 10 20 1 1 2p i , 6 m IG 15 RCPT - P IS #8 1,200 / //� /� 12 20 1 1 20 12 720 i/ 12 IG /////� 39 ///// ///// SPARE o 1,200 / 12 20 1 1 20 12 i i RCPT - OFFICE SUPPORT 1 14 IG 11 LTG-TRACK-6 ///// 10 20 1 1 20 g N IG 17 RCPT - POS #9 i / , /, / - OFFICE SUPPORT 2 16 IG 13 LTG-TRACK-7 39 10 20 1 1 20 i //� SPARE 1,200 12 20 1 1 20 12 i ' i 39 i � ////� SPARE 10 0, IG 19 RCPT - POS RETURNS 1 i /�/� / RCPT - SAFE RM 15 LTG-TRACK-8 , ////� /////� 10 20 1 1 20 i IG 21 RCPT - POS RETURNS 2 i 1,200 ///� 12 20 1 1 20 12 180 i /////� 39 ///%� %//// SPARE 12 2, //� 1,200 //i ////� SECURITY PANEL 20 IG 17 LTG-TRACK-9 , ////// 10 20 1 1 20 i o IG 23 RCPT - POS RETURNS 3 i , i/////i 12 20 1 1 20 12 i / %/////i SPARE 14 0 //540 12 i////// 720 i - TELE/COM RM GEN 1 19 LTG-TRACK-10 ////� 3g 10 20 1 1 20 i i 16 25 RCPT - CEILING STOCK RM 540 ////� i //�� ///� 720 RCPT - TELE/COM RM GEN 2 24 IG i ///� 10 2p 1 1 2p / SPARE //// 12 20 1 1 20 12 720 21 LTG-TRACK-11 i 39 18 IG 27 RCPT - INFO DESK 1 i //// i//,/ RCPT - TELE COM RM GEN 3 23 LTG-TRACK-12 � //� 360 �////, 12 20 1 / / 28 IG SPARE 20 G 29 RCPT - INFO - TELCOM RACK 1A 28 IG 25 LTG-TRACK-13 39 10 20 1 1 2p i , IG 31 RCPT - INFO DESK 3 i /��/� ///,// 360 RCPT - TELCOM RACK 2A 27 LTG-TRACK-14 , 39 � 10 20 1 1 20 /// „ SPARE 24 - TELCOM RACK 3A 30 IG , 12 20 1 1 20 12 i IG 35 RCPT - POS BIKE1,200 12 20 1 1 20 12 /////, 360i - TELCOM RACK 1B 31 LTG-TRACK-16 ///// ////� 39 10 20 1 1 20 i G 37 RCPT - MONOGRAMING i ��//� / 360 RCPT - TELCOM RACK 2B 34 IG 1so //// %///// 1z 20 1 1 zo 12 3so IG 39 RCPT- POS STOCK 1 TELCOM RACK 3B 36 IG G 38 IG // SPARE 32 1,200 SPARE 37 LTG-TRACK-19 ////� ////�i 39 10 20 1 1 20 ////� 34 SUBTOTAL 20 1 1 20 //,j/� ///// SPARE 42 /////� ////// 10 20 1 1 20 i 12,706 13,436 13,920 42 39 LTG-TRACK-20 ///� 39 , / %///// SPARE 36 0 TOTAL PHASE A - VA 16,486 LOAD 3,780 3,240 3,240 SUBTOTAL 41 LTG-TRACK-21 ; /// 10 20 1 1 20 %/////i / /, SPARE 38 8 4 AMPS CONN. VA DF LOAD /////� %///% 39 10 20 1 ///� 40 137 COOLING 1,306 CONN. VA pF SUBTOTAL 1 20 ///� SPARE o TOTAL PHASE B - VA 16,676 ----- -'--'-- 1.00 REFRIGERATION 1.00 585 546 546 42 o HEATIN-.-. -________ 1,306 D SIGN DISPLAY TOTAL PHASE A - VA 585 SUBTOTAL 0 AMPS 139 LIGHTING 1.25 LOAD CONN. VA DF LOAD TOTAL PHASE C -ECETT --------_ 600 1.25 KITCHEN �- AMPS 5 COOLING CONN. VA DF VA 17,160 RECEPTACLES 17820 1.00 TOTAL PHASE B -'- ------- 1.00 REFRIGERATION AMPS ----'-'------ 1.0/.5 EXISTING - VA 546 HEATING 1.00 a v a G n A 143 MOTORS 1,136 1.00 LARGE MOTOR -- - ---- --- -- 1.00 AMPS SIGN/DISPLAY ---- ---- ----- TOTAL PNLBD - VA 50,322 SUPP HEAT 0 1.25 �0 w g o 1.25 TOTAL DEMAND TOTAL PHASE C - VA 546 LIGHTIN- G - 1 716 1.25 KITCHEN J w AMPS 140 MISC EQUIP- --�Ip'-'--_ 1.00 SHOW WINDOW 8,300 1,25 RECEPTACLES 1.00 PANELBOARD NOTES 29,460 1.00 LTG TRACK 56,937 VA AMPS 5 1.0/.5 EXISTING 1.00 MOTORS 1.00 LARGE MOTOR 1.25 PNLBD UA LOADS ARE INCLUDED IN TOTAL DEMAND LOAD FOR THIS PANEL 158 A TOTAL PNLBD A VA 1,677 SUPP HEgT -'-- 1.25 -------,__ 1.00 SHOW WINDOW TOTAL DEMAND G-ISOLATED GROUND PANELBOARD NOTES AMPS 5 MISC EQUIP 1.00 LTG TRACK --- -'-'-- 1.25 ,69645 VA 67,500 1.00 LTG TRACK - TRACK LENGTH 193 A PNLBD L2A LOAD INCLUDED IN TOTAL DEMAND LOAD SIGN DISPLAY SIGNAGE & DISPLAY CASE LTG TRACK - TRACK LENGTH SIGN DISPLAY - SIGNAGE & DISPLAY CASE PANELBOARD: L1A (NEW) BUS AMPS: 225A FAULT CURRENT: 6200 A MAIN SIZE/TYPE: MLO AIC RATING:10,000 FULLY RATED EQUIPMENT GROUND BUS PANELBOARD: L2A (NEW) VOLTS/PHASE: 208Y/12OV, 3PH, 4W SERVES: FIRST FLOOR BUS AMPS: 225A FAULT CURRENT: 6088 A SECTION: 1 MOUNTING: SURFACE FEED THRU LUGS MAIN SIZE/TYPE: MILO AIC RATING:10,000 FULLY RATED EQUIPMENT GROUND BUS CKT DESCRIPTION LOCATION: STORAGE ROOM VOLTS/PHASE: 208Y/120V, 3PH, 4W SERVES: N0. VOLTAMPS PHASE WIRE BKR P P BKR WIRE SECTION: 1 MOUNTING: SURFACE FEED THRU LUGS q B C NO. AMP VOLTAMPS PHASE DESCRIPTION LOCATION: STORAGE ROOM 1 RCPT - WEST WALL 72D � AMP N0. A g C CKT CKT DESCRIPTION VOLTAMPS PHASE WIRE BKR P P BKR WIRE VOLTAMPS PHASE 3 RCPT - SOUTH WALLDUCT DETECTOR-RTU-1-5 A B C NO. AMP DESCRIPTION 5 RCPT - SOUTH DISPLAY AREA /i 12 20 1 1 20 10 %/// � 900 2 1 LTG-TRACK-43 AMP N0. A g C CKT ////� ////� 540 12 20 1 1 20 10 /� i , RCPT-ROOF RTU-1-5 ¢ 3 SPARE 39 ////�' ///%�i 10 20 1 1 20 10 39 N0. 7 RCPT - RETURNS/STORAGE 540 i 12 20 1 1 20 10 /3 0// ///�� ,, 540 RCPT-ROOF RTU-6-8 %//� /�//// //// LTG-TRACK-22 9 RCPT - NORTH WALL i ///,//� 720 %%i%/� 12 20 1 1 20 12 % ////� ////� DUCT DETECTOR-RTU-6-8 11 RCPT - CENTER 8 7 SPARE 20 1 1 20 10 � i/i 720 12 20 1 1 20 12 %i i ,� / ' ' RCPT - SHOW WINDOW SW 10 13 RCPT - ENTRANCE i// / /i//� RCPT - SHOW WINDOW 12 20 1 1 20 12 360 i / 15 RCPT - ENTRANCE � ' - SHOW WINDOW 17 RCPT - FISH TANK //�. � 12 20 1 1 20 12 %//// 360 % //' 14 13 SPARE 20 i 1 20 10 %////i %/////i 39 LTG-TRACK-27 10 19 SPARE �///�� �////i 360 12 20 1 1 20 12 / , !•;�"� /, /, /, RCPT - LOUNGE COMPUTER %///,'ii ////%; 20 1 1 20 10 3g ii i 12 RCPT - REF. LOUNGE 18 15 SPARE , 20 1 1 zo 12 1,zoo 21 RCPT - COLUMN C3 �i�// / �' �'"" 18 17 SPARE 23 RCPT - BIKE SHOP 2ND FLR , 12 20 1 1 RCPT - MW LOUNGE 2p 19 SPARE///�� � "�i 720 12 20 1 1 20 12 / 180 ,i FACP 22 21 ARE % � �///,%%i 20 1 1 20 10 3 i . 39 LTG-TRACK-30 18 25 SPARE 20 1 1 20 10 /1.306/ GU-1 1 1 20 10 / LTG-TRACK-31 27 RCPT - SPORTING GOODS i' i i 24 23 SPARE ////// ,/ ///%/ 39 %/;iij LTG-TRACK-32 20 20 1 1 20 10 � � ////// / IU-1,OU-1 26 25 SPARE 20 1 1 20 10 / � //,� 22 29 RCPT - INFO DESK AREA //// 360 12 20 1 1 20 10 ////�i 1,136 EF-i,EF-2,EFgg / i//��/ 39 LTG-TRACK-33 31 RCPT - WOMENS FITTING RM 72p 12 20 1 1 20 %///� //i 600 LTG-CHANDELIER %////� iii / /////i ////� LTG-TRACK-34 24 33 RCPT - NORTH EAST WALL 35 RCPT - GENREAL USE STOCK RM / i �///�ii �//%�i SPARE 32 31 SPARE i 20 1 1 20 10 � i 28 12 20 1 1 20 / " / 37 RCPT - RESTRONG GFCI 720 12 20 1 1 20 / 34 33 SPARE /////� SPARE 39 RCPT - VM LOUNGE i i 36 20 / 20 1 1 20 i SPARE i//i//i %/////i "'���� 39 %/,�i LTG-TRACK-38 41 RCPT - DRINKING FOUNTAIN /�%/ /� " 72D 12 20 1 1 20 ////j,. 38 37 SPARE 20 1 1 20 LTG-TRACK-39 34 i SPARE 40 39 SPARE //i,�/ %/, /,/� 20 1 1 20 10 3g i i 36 SUBTOTAL 3,240 3,780 4,140 ////// SPARE ///�%i i%////i 20 1 1 20 10 % ///// ////// LTG-TRACK-40 3,586 2,936 2,220 42 41 SPARE i%/� ;i�///i ///�/i 39 �1XZIi LTG-TRACK-41 38 TOTAL PHASE A - S 6,826 LOAD SUBTOTAL 20 1 1 20 10 %//,/// ////� 39 LTG-TRACK-42 40 AMPS CONN. VA DF DIG 57 CONN. VA DF SUBTOTAL 39 COOLING 1,3061 00 TOTAL PHASE 273 42 TOTAL PHASE B - VA 6,716 �- 1.00 REFRERATION 312 LOAD 273 273 SUBTOTAL HEATIN.-____�__._.____- 1,306 0 SIGN DISPLAY CONN. VA AMPS 56 LIGHTING 600 / 1.25 AMPS 3 DF LOAD CONN. VA VA 6,360 - 1'25 TOTAL PHASE B COpLIN---G-------- 1.00 REFRIGERATION DF 1 ; TOTAL PHASE C RECEPTACLES 14 580 KITCHEN -_____________ 1.00 - VA 273 1.00 --------,--____ 1.0/.5 EXISTING HEATING SIGN/DISPLAY I- - AMPS 53 MOTORS 1.00 AMPS 2 LIGHTING Sg7 1.25 KITCHEN 1.25 TOTAL PNLBD - VA 19,902 SUPP HEAT 608 1.00 LARGE MOTOR ----- -528 1 25 TOTAL PHASE C - VA 273 RECEPTA�- 1.00 ---------___ 1.00 SHOW WINDOW �- TOTAL DEMAND AMpS 2 - 1.0/.5 EXISTING AMPS 55 MISC EQUIP 2,280 1.00 LTG TRACK 8,300 1,25 MOTORS 1.00 PANELBOARD NOTES 28,269 VA TOTAL PNLBD - VA 858 --- -�---'-- I LARGE MOTOR 1.00 78 A SUPP HEAT AMPS 2 MISC EQ- UI- p'----- 1.00 SHOW WINDOW 1.25 PANELBOARD NOTES 1.00 LTG TRACK �0 1.00 34,871 VA 97 A LTG TRACK - TRACK LENGTH SIGN DISPLAY - SIGNAGE & DISPLAY CASE LTG TRACK - TRACK LENGTH SIGN PANELBOARD: L1 B (NEW) DISPLAY - SIGNAGE & DISPLAY CASE BUS AMPS: 225A FAULT CURRENT: 3434 A MAIN SIZE/TYPE: 200A MCB AIC RATING:10,000 FULLY RATED EQUIPMENT GROUND BUS VOLTS/PHASE: 208Y/12OV, 3PH, 4W SERVES: FIRST FLOOR SECTION: 1 MOUNTING: SURFACE FEED THRU LUGS CKT DESCRIPTION LOCATION: STORAGE ROOM, ROOM : NO. VOLTAMPS PHASE WIRE BKR P P BKR WIRE VOLTAMIPS PHASE 1 BIKE LIFT 1 A B C N0. AMP AMP N0. A B DESCRIPTION CKT C // IOU i NO. 180 / SENSORMATIC - DOCK 2 5 BIKE LIFT 2 %/%/ �///jam 1,200 10 2p 1 1 20 12 //'/j; 180 //f//� SENSORMATIC-REAR DOOR 7 180 SENSORMATIu-FRONT W 9 BIKE LIFT 3 j�//// 1 200 20 12 180 /////� / SENSORMATIC - FRONT E 6 8 1 200 /� WER 13 RCPTS ASSIST D00 COLUMS SALES 1 20 12 '�// i 1,800 POWER ASSIST DOORS E2 10 15 RCPTS - TV'S 1 ///� //////, 12 20 1 1 20 12 � 12 20 1 1 20 12 j RCPT- TMB 14 17 RCPTS - BIKE SHOP �/ 72D 12 20 1 1 20 12 // 180 //�// SENSORMATIC-OFFICES 19 RCPTS - COLUMN B z 180 ALARM EXIT DEVICE 16 21 WATER HEATER /�i 12 20 1 1 20 12 360 �/j// ��/ RCPTS-TV 18 23 SPARE 180 i;�///� 20 1 1 20 2p . /,ice/� 25 SPARE 20 1 1 20 /i/�i %//i�ii SPARE 22 27 SPARE ��//ii �////%r 20 1 1 20 i , 24 � L Bean /�/i ii%/// 20 1 1 20 - /�/// //////i SPARE 29 SPARE � //%%ice SPARE 26 31 HAND DRYER 20 1 1 20 /��� SPARE 28 33 2 1 20 i 840 %ice//� ; ," �Z// SPARE 30 35 HAND DRYER /� /////i 840 12 20 2 1 2p /� ; ���//� SPARE 32 37 ///// SPARE 39 HAND DRYER 840 i ////�� 1 20 ,� 36 41 //� 840 %/�//� 12 20 2 1 20 i/ SPARE 38 / 840 / //i SPARE 40 SUBTOTAL 1 20 ///%� ///% SPARE 5,340 5,160 4,800 42 TOTAL PHASE A - VA 6,420 LOAD 1,080 2,160 2,160 SUBTOTAL AMPS 54 CONN. VA DF LOAD CONN. VA OF TOTAL PHASE B - V COOLING 1.00 REFRIGERATION n+ re na ti A 7,320 HEATING AMPS 61 LIGHTING 0 SIGN/DISPLAY ---- -'-- 1.25 TOTAL PHASE C - VA 6,960 �- 1.25 KITCHEN 1.25 RECEPTACLES '4Y ----r -- 3,600 1.0 5 �o�� COV/U`� >? oo�La`ram R. LA7i 1.DD y Q'( Q' r•. AMPS 58 /• EXISTING Leo a yy MOTORS 10,800 1.00 LARGE MOTOR ------ ---------- 1.00 ( 4 TOTAL PNLBD - VA 20,700 SUPP HEAT 1,25 0�so 1.00 SHOW WINDOW TOTAL DEMAND u�;e^ No 7r;V1 PANELBOARD NOTES AMPS 57 MISC EQUIP 6,300 1.00 LTG TRACK 1.25 20,700 VA 1.00 57 A $ LTG TRACK - TRACK LENGTH SIGN DISPLAY - SIGNAGE & DISPLAY CASE The Shops at Evergreen Walk South Windsor, CT Electrical Panel Schedules I Checked By: 0m Job No: 06125.00 ENGINEER OF RECORD: E203 Craig R . Lanham I 8325 LETEL 913 307-530040 FAX: 913-307-5400 SUITE 14-1695 : WEB: WWW.HENDERSONENGINEERS.COM 0650001687 U LIGHT FIXTURE SCHEDULE ELECTRICAL SYMBOLS TYPE MANUFACTURER MODEL LAMP VOLTAGE VA DESCRIPTION ABBREVIATIONS (ALL ABBREVIATIONS SHOWN ARE NOT 15 G1 BK LED 120 30 GROUND MOUNTED ADJUSTABLE LED SPOTLIGHT WITH NECESSARILY USED ON THE DRAWINGS. U A G P (CONT.) POWER EQUIPMENT & DEVICES WIRING DEVICES & OUTLETS vw MM-LED-201-9-A-360SL ADJUSTABLE HEAD AND CUT-CONE SNOOT. TO UPLIGHT A AMPERES, AIR (COMPRESSED) cc GENERAL CONTRACTOR PNLSD PANELBOARD Q OR PRE-APPROVED EQUAL TREES AT ENTRY. FINISH TO BE VERIFIED BY ARCHITECT A/C AIR CONDITIONING GFCI GROUND FAULT CIRCUIT INTERRUPTER PROVIDE FURNISH AND INSTALL _ Tt ELECTRICAL SERVICE PANELBOARD (SURFACE OR FLUSH MOUNT) $ SINGLE POLE WALL SWITCH (NO LETTER DESIGNATION) ACC AIR COOLED CHILLER GFR GROUND FAULT RELAY PRV PRESSURE REDUCING VALVE 2 E L1 PRUDENTIAL (4) 32W T8-XL- 277 128 8' PENDANT LINEAR FLUORESCENT DOWNLIGHT WITH ACCU AIR COOLED CONDENSING UNIT G. GND GROUND PT POTENTIAL TRANSFORMER o TERMINAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED SWITCH LETTER DESIGNATIONS AS FOLLOWS: = m R 2 = TWO POLE WALL SWITCH OS OCCUPANCY SENSOR M7-2T8-08-RBL-Y-D1 SERIES SP30-WM-EGO BLADE BAFFLES. GENERAL AMBIENT LIGHTING AT AF AMPERE FUSE GPM GALLONS PER MINUTE P PAN, TILT, 200M o PLYWOOD TERMINAL BOARD FOR TELEPHONE SYSTEM, UNO. SIZE AS NOTED. 3 = THREE-WAY WALL SWITCH P = SPST PILOT LIGHT SWITCH (LIT WHEN ON) 03 OR PRE-APPROVED EQUAL PERIMETER. HANG AT +16'-0" A.F.F. OVER RETAIL. HANGE AFC ABOVE FINISHED CEILING GRS GALVANIZED RIGID STEEL n 4 = FOUR-WAY WALL SWITCH K = KEYED LIGHT SWITCH o AT +14'-0" A.F.F. OVER FITTING ROOMS. FINISH PER AFCI ARC FAULT CIRCUIT INTERRUPTER Q ELM ELECTRICAL DISTRIBUTION PANELBOARD D = DIMMER TYPE SWITCH M = MOTOR RATED SWITCH N AFEA AREA FOR EVACUATION ASSISTANCE H OTY QUANTITY ARCHITECT. PAINTED "LL BEAN GREEN"? ®/ SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD t AFF ABOVE FINISHED FLOOR HD HEAD, HUB DRAIN rn R 6 SIMPLEX RECEPTACLE - NEMA 5-20R, UNO c L1A PRUDENTIAL (2) 32W T8-XL- 277 64 4' PENDANT LINEAR FLUORESCENT DOWNLIGHT WITH AFG ABOVE FINISHED GRADE HOA HAND-OFF-AUTOMATIC RA RETURN AIR a AHU AIR HANDLING UNIT HTG HEATING .209 3/150 MOTOR 6 DUPLEX RECEPTACLE - NEMA 5-20R, UNO a M7-2T8-04-RBL-Y-D1 SERIES SP30-WM-ECO BLADE BAFFLES. GENERAL AMBIENT LIGHTING AT A ANALOG INPUT HTR HEATER RC ROOM CRITERIA Lam) DISCONNECT SWITCH - "200/3/150" DENOTES AMPERES/POLE/FUSE V OR PRE-APPROVED EQUAL PERIMETER. HANG AT +16'-0" A.F.F. OVER RETAIL. RANGE Ac AMPERE INTERRUPTING CURRENT HVU HEATING AND VENTILATING LINT RCP REINFORCED CONCRETE PIPE NF= NON-FUSED CB= CIRCUIT BREAKER (200 3 CB/ / ) 3R= NEMA 3R DOUBLE DUPLEX RECEPTACLE - NEMA 5-20R, UNO RCPT RECEPTACLE 30 3/15/1 ALUMINUM HWP HEATING WATER PUMP AT +14'-0" A.F.F. OVER FITTING ROOMS. FINISH PER AL RD ROOF DRAIN COMBINATION DISCONNECT (SAFETY) SWITCH AND MOTOR STARTER � HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED ARCHITECT. PAINTED "LL BEAN GREEN"? AO ANALOG OUTPUT REV REVISION 30/3/15/1" DENOTES AMPERES/POLE/FUSE/NEMA STARTER SIZE TWIST-LOCK TYPE RECEPTACLE AP ACCESS PANEL I RF RETURN FAN NF= NON-FUSED CB= CIRCUIT BREAKER (30/3/CB/1) ATS AUTOMATIC TRANSFER SWITCH IE INVERT ELEVATION RECEPTACLE INSTALLED 6" ABOVE COUNTER OR BACKSPLASH L2 PRUDENTIAL (2) 32W T8-XL- 277 64 TWO LAMP CROSS SECTION LINEAR FLUORESCENT A1YG AMERICAN WIRE GAUGE IG ISOLATED GROUND RH RELATIVE HUMIDITY, ROOF HOOD ®2 MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED. 3-POLE, UNO. WALL-24-SD-1T8-04-CC-SC-WM SP30-WM-ECO VALANCE WITH SOLID FRONT. PUBLIC BATHROOMS a IN WC INCHES OF WATER COLUMN RHG REFRIGERANT HOT GAS ® MANUAL STARTER CEILING MOUNTED DUPLEX RECEPTACLE LITECONTROL V3 MOUNTED HORIZONTAL OVER STALLS AND IN HALLWAY. RLA RUNNING LOAD AMPS OR PRE-APPROVED EQUAL PAINTED CUSTOM "LL BEAN "GREEN" SAS BUILDING AuroMATION srsrEM J RPM REVOLUTIONS PER MINUTE ©L MAGNETIC CONTACTOR, SIZE, COIL VOLTAGE AND NUMBER OF POLES ® FLOOR MOUNTED DUPLEX RECEPTACLE SO SACKDRAFT DAMPER, SLOWDOWN JB, J-BOX JUNCTION BOX RTU ROOFTOP UNIT AS INDICATED (L= LIGHTING CONTACTOR, P= POWER CONTACTOR) ISOLATED GROUND (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) �? L4 LITHONIA (3) 32W T8-XL- 277 96 INDUSTRIAL (3) LAMP CROSS SECTION LINEAR BFF BELOW FINISHED FLOOR 3 TS TIME SWITCH K epc BELOW FINISHED GRADE o pC 6 EMERGENCY POWER (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) 111116 COLUMBIA SP30-WM-ECO FLUORESCENT WORKLIGHT WITH WIRE GUARD. BOH kemil 1000 CIRCULAR MIS SA SUPPLY AR ❑ PHOTOCELL qj 9 t e 5 OR EQUAL STOCKROOM GENERAL ILLUMINATION.FIXTURE QUANTITY, BFP BOILER FEED PUMP kV KILOVOLT SD SMOKE DETECTOR ��-{( RECEPTACLE INSTALLED VIA DROP CORD '9 B o No BI BINARY INPUT SF SQUARE FEET, SUPPLY FAN �1 INDICATING LIGHT GFCI .0 ;� u N " N SPACING, AND MOUNTING HEIGHT TO BE VERIFIED BY kVA KILOVOLT-AMPS �JjL BKR BREAKER SPOT SINGLE-POLE, DOUBLE-THROW QV RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: U ARCHITECT kVAR KILOVOLT-AMPS REACTIVE PUSH BUTTON C = CLOCK HANGER TYPE IG = ISOLATED GROUND ° 0 ^ N SO BINARY OUTPUT SPSi SINGLE-POLE, SINGLE-THROW kw KILOWATT E = EMERGENCY POWER GFCI = GROUND FAULT CIRCUIT INTERUPTER � °� tl BOD BOTTOM OF DUCT SP STATIC PRESSURE, SUMP PUMP • • STOP-START PUSH BUTTON CONTROL STATION S = SWITCHED WP = WEATHERPROOF .°3 °�' v' Cr L5 LITHONIA (1) 17W T8-XL- 277 17 BARE STRIP LINEAR FLUORESCENT IN ARCHITECTURAL a"i p kWH KILOWATT-HOUR fi s o BOP BOTTOM OF PIPE ss STAINLESS STEEL SANITARY SEWER, b COLUMBIA SP30-WM-ECO MIRROR DETAIL. CHANGING ROOM MIRROR. VERIFY BOS BOTTOM OF STRUCTURE SOIL STACK HE HAND-OFF-AUTO PUSH BUTTON CONTROL STATION o a 9OR EQUAL DETAILS WITH ARCHITECT. COORDINATE LENGTHS BN BRITISH THERMAL UNIT U ST STEAM TRAP . QQ Q POKE THROUGH ¢� w pa w a. L LOUVER ❑-D MUSHROOM-TYPE PUSH BUTTON A A = TYPE, SEE SCHEDULE WITH ARCHITECTURAL DRAWINGS O LAT LEAVING AIR TEMPERATURE STc SOUND TRANSMISSION CLASS C CONDUIT LDS LEAVING DRY BULB srM STEAM W OVERHEAD PADDLE FAN m ♦ TELEPHONE OUTLET - FLOOR OR WALL MOUNTED. 1_6 LITECONTROL (2) 32W TB-XL- 277 64 LINEAR FLUORESCENT STACKLIGHT. MOUNTED CENTERED CD CANDELA IF LINEAR FEET SWBD SWITCHBOARD INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. S-D-0518-T8 SERIES SP30-WM-ECO BETWEEN WOOD JOISTS IN CASH/WRAP AND BIKE CT CURRENT TRANSFORMER LP LOW PRESSURE T ® v TELE/DATA OUTLET - FLOOR OR WALL MOUNTED. CCTV CLOSED CIRCUIT TELEVISION FIRE ALARM OR PRE-APPROVED EQUAL MAINTENANCE. SEE ARCHITECTURAL DETAIL CC V CABLE TELEVISION SYSTEM LRA LOCKED ROTOR AMPS TC/C TEMPERATURE CONTROLS CONTRACTOR INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. LWB LEAVING WET BULB CH TDH TOTAL DYNAMIC HEAD ® V DATA OUTLET - FLOOR OR WALL MOUNTED. CFM CUBIC FEET PER MINUTE FACP - FIRE ALARM CONTROL PANEL (SURFACE OR RECESSED MOUNTED L7 LITECONTROL MOD2 (4) 32W T8-XL- 277 128 LINEAR FLUORESCENT SQUARE FORM WALLBRACKETED CHILLER LWi LEAVING WATER TEMPERATURE TFA TO FLOOR ABOVE r� INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. �— W-D-4428T8-BW-CWM SERIES SP30-WM-EGO DOWNLIGHT WITH BLADE BAFFLES. ABOVE COUNTER AT cKr clRcuIT M TFB TO FLOOR BELOW ( ) OR PRE-APPROVED EQUAL BIKE SHOP MOUNTED TO SOFFIT ABOVE ON INSIDE OF cP CONDENSATE PUMP MAry TL TWISTLOCK MISC ANNUNCIATOR PANEL MULTI-OUTLET SURFACE RACEWAY WITH NEMA 5-20R MASTER ANTENNA TELEVISION SYSTEM ,-, SHOP AREA CRAC COMPUTER ROOM AIR CONDITIONING UNIT MAU MAKE-UP AIR UNIT TT TEMPERATURE TRANSMITTER RA - REMOTE ANNUNCIATOR PANEL FPC - FIRE PUMP CONTROLLER RECEPTACLES 12" ON CENTER, UNO. TWU THROUGH WALL AIR CONDITIONING UNIT RD - REMOTE DIALER GSP - GENERATOR STATUS PANEL CRU COMPUTER ROOM UNIT MAX MAXIMUM ESP - ELEVATOR STATUS PANEL AHSP- AIR HANDLER STATUS PANEL 8 THERMOSTAT cr coourlc TOWER MBH 1000 BTU PER HOUR L8 LITECONTROL WALL/SLOT (1) 32W T8-XL- 277 32 LINEAR FLUORESCENT WALL SLOT. BATHROOM TX TRANSFORMER VE - VOICE EVACUATION PANEL 2018-T8-CWM-ELB SERIES SP30-WM-ECO WET-WALL. CTP CwP CHILLEG TOWER PUMP MCA MINIMUM D WATER PUMP MCC MOTOR COIRCUIT NTROL CMPACITY EMER TU1/'PF TYPUNDICAL ERFLOOR D FIRE ALARM PULL STATION ❑J OR � JUNCTION BOX/OUTLET BOX OR PRE-APPROVED EQUAL CU COPPER, CONDENSING UNIT MCS MAIN CIRCUIT BREAKER U S MULTI-SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER OUTLETS ❑ SMOKE DETECTOR, E = ELEVATOR RECALL A A = TYPE, SEE SCHEDULE P1 DIVERSIFIED ARCHITECTURAL (4) 32W TT 277 128 HIGH-BAY SPUN ALUNIMUM PENDANT (4) COMPACT D MD MOTORIZED DAMPER U/c UNDERGROUND ❑S SD DUCT SMOKE DETECTOR (SD=SUPPLY RD=RETURN)MOP MAIN DISTRIBUTION PANEL UH UNIT HEATER LIGHTING FLUORESCENT DOWNLIGHT WITH INTERNAL REFLECTOR DDC DIRECT DIGITAL CONTROL MFR MANUFACTURER U/S UNDERSIAB ❑H 165 HEAT DETECTOR DBFAL-1 6-PXX-4X32TRT-VOLT- AND LENS. DUAL SWITCHED. GENERAL AMBIENT LIGHTING DI DIGITAL INPUT, DUCTILE IRON MG MOTOR GENERATOR UL UNDERWRITERS LABORATORIES, INC. NUMBER = TEMP RATING, RR = RATE OF RISE, COMB = SMOKE/HEAT CIRCUITING & WIRING CC-CL-REM IN PERIMETER AREAS-EMERGENCY BALLASTS SPECIFIED ON ON DOWN MH MANHOLE UNO UNLESS NOTED OTHERWISE 75 5 DpOr DOUBLE-POLE, DOUBLE-THROW PROJECTED BEAM DETECTOR 3 HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER OF CIRCUITS, PLAN PER ELECTRICAL ENGINEER. STEM LENGTH AND MIN MINIMUM UPS UNINTERRUPTIBLE POWER SUPPLY HASH MARKS INDICATE NUMBER OF CONDUCTORS. INFORMATION AT DPI DIFFERENTIAL PRESSURE INDICATOR MLO MAIN LUGS ONLY 0 WATER FLOW ALARM SWITCH (ALARM) P1 ARROWS ARE CIRCUIT NUMBERS AND PANELBOARD. COLORS TO BE VERIFIED BY ARCHITECT. DPST DOUBLE-POLE, SINGLE-THROW OR MOCP MAXIMUM OVERCURRENT PROTECTION V P1-3,5,7 DS DOWNSPOUT, DUCT SILENCER MSB MAIN SWITCHBOARD v VOLT(S) G3 GATE SWITCH (SUPERVISORY) P1A DIVERSIFIED ARCHITECTURAL (4) 32W TT 277 128 HIGH-BAY GLASS REFRACTOR PENDANT (4) COMPACT DX DIRECT EXPANSION MS/TP MASTER SLAVE/TOKEN PASSING - VAC VOLTS ALTERNATING CURRENT FPS1 PRESSURE SWITCH, LOW AIR. (SUPERVISORY) EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT LIGHTING FLUORESCENT DOWNLIGHT AND LENS. DUAL SWITCHED E COMMUNICATION TRUNK VDC VOLTS DIRECT CURRENT (GREEN INSULATION OR BARE) DBFPR-16-P10-4X32TRT-VOLT- WITH DAYLIGHT. GENERAL AMBIENT LIGHTING IN EA EXHAUST AIR MID MOUNTED VAV VARIABLE AIR VOLUME PV POST INDICATING VALVE (SUPERVISORY) ISOLATED GROUNDING CONDUCTOR IN CONDUIT CC-CL CLERESTORY CENTRAL SPACE-EMERGENCY BALLASTS FAT ENTERING AIR TEMPERATURE MU MAKE-UP VCP VITRIFIED CLAY PIPE (�I,1 GREEN INSULATION WITH YELLOW TRACER) SPECIFIED ON PLAN PER ELECTRICAL ENGINEER. STEM EDB ENTERING DRY BULB VFD VARIABLE FREQUENCY DRIVE �15 FIRE ALARM HORN LENGTH AND CAP COLOR TO BE VERIFIED PER ARCHITECT. EF EXHAUST FAN N vs VENT STACK CONDUIT CONCEALED I r y FIRE ALARM STROBE LIGHT _ EM LIGHT FIXTURE WITH EMERGENCY BATTERY N/A NOT APPLICABLE VTR VENT THROUGH ROOF 15 NUMBER INDICATES CANDELA, 15 CD UNO. _� _ CONDUIT IN/UNDER FLOOR/GROUND CONSTRUCTION EPO EMERGENCY POWER OFF N/C NORMALLY CLOSED P2 LSI ABOLITE STANDARD DOME 1 32W TT 277 32 INDUSTRIAL SPUN ALUMINUM COMPACT FLUORESCENT ESFR EARLY SUPPRESSION FAST RESPONSE NC NOISE CRITERIA IKf 1 FIRE ALARM HORN STROBE COMBINATION —__ ( ) EXPOSED CONDUIT W NUMBER INDICATE CANDELA, 15 CD UNO. — RD 100-32CFL-SERIES DOWNLIGHT PENDANT. PORCH AND ENTRY VESTIBULE. ETR EXISTING TO REMAIN NIC NOT IN CONTRACT W WIRE FLEXIBLE CONDUIT HUNG FROM JUNCTION BOX ON HANG-STRAIGHT SWIVEL. EWB ENTERING WET BULB NL NIGHT LIGHT W/ WITH I L.J FIRE ALARM BELL ON PORCH, COORDINATE SPACING BETWEEN RAFTERS. EVC ELECTRIC WATER COOLER N/O NORMALLY OPEN W/o WITHOUT - - LOW VOLTAGE CABLE EWT ENTERING WATER TEMPERATURE we WET BULB IxL.J FIRE ALARM BELL/STROBE COMBINATION CUSTOM COLOR PER ARCHITECT WP WP = WEATHER PROOF G We WATER COLUMN O CONDUIT TURNING DOWN F oA OUTSIDE AIR OS F FIRE ALARM SPEAKER - CEILING MOUNTED P3 2,000 DEGREES LEXINGTON (1) 32W TT 277 32 DECORTATIVE COMPACT FLUORESCENT PENDANT WITH FACP FIRE ALARM CONTROL PANEL oc ON CENTER WG WATER GONG p WPD WATER PRESSURE DROP FBO FURNISHED BY OTHERS/OWNER CONDUIT TURNING UP PENDANT CUSTOM SHADE: LL BEAN WALLPAPER. FITTING ROOM oRD OVERFLOW ROOF DRAIN o FIRE ALARM SPEAKER/STROBE COMBINATION CONNECTION POINT OR EQUIPMENT TERMINATION Fcu FAN COIL UNIT WP WEATHERPROOF NUMBER INDICATES CANDELA, 15 CD LINO. 70OTDLEXP-CUSTOM HALL OS OCCUPANCY SENSOR Ws WASTE STACK OR PRE-APPROVED EQUAL FD FLOOR FFA FROM FLLOOROOKDRAIN ABOVE P Wr WATERTIGHT. WEIGHT ♦M FIREMANS PHONE JACK EQUIPMENT TERMINATION P4 AS SPECIFIED BY ARCHITECT (6) 1 DOW Al 120 600 DECORATIVE CHANDELIER, FFB FROM FLOOR BELOW p POLE ® FIREMANS PHONE JACK FF FINISHED FLOOR PCR PUMPED CONDENSATE RETURN X M = MASTER PHONE STATION LIGHTING ENTRY, FHC FIRE HOSE CABINET XPMR TRANSFORMER M PDI PLUMBING DRAINAGE INSTIME XP EXPLOSION-PROOF ® AFEA OF REFUGE 2-WAY COMMUNICATION SYSTEM V -0" AFF FL FLOW LINE PDU POWER DISTRIBUTION UNIT M = MASTER PHONE STATION FLUORESCENT LIGHT FIXTURE: a = SWITCHED BY SWITCH FLA FULL LOAD AMPS PH, 0 PHASE A a ° (SEE LIGHT FIXTURE SCHEDULE) A = LIGHT FIXTURE TYPE "A" R1 LITHONIA (3) 32W TB-XL- 277 96 RECESSED 2'X4' TROFFER WITH ACRYLIC LENS IN BOH ACT FLR FLOOR PIV POST INDICATOR VALVE DH MAGNETIC DOOR HOLD-OPEN DEVICE COLUMBIA SP30-WM-ECO CEILINGS. BOH STAFF AREAS FU FURNACE PNL PANEL RL REMOTE INDICATING LIGHT ° PORTFOLIO FVNR FULL-VOLTAGE, NON-REVERSING OR EQUAL ELECTRICAL ONE—LINE & RISER RT REMOTE TEST STATION FLUORESCENT LIGHT FIXTURE WITH NIGHT LIGHT FR FAN SHUTDOWN RELAY R2 LITHONIA (2) 32W T8 277 64 RECESSED 2'X2' TROFFER WITH ACRYLIC LENS IN BOH ACT I 800A SWITCH T 400A DRAWOUT CIRCUIT 0 FLUORESCENT LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY PACK COLUMBIA U SHAPE CEILINGS. SIMILAR TO R1. BOH STAFF AREAS 1 3P RATING AS SHOWN / 3P BREAKER. RATINGS SIGNALING PORTFOLIO \ AS SHOWN, 3 POLE, FLUORESCENT LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED SEPARATELY. � OR EQUAL �lu9�STCCC UNO I�N SIGNALING BELL © LV TRANSFORMER ° (SHADING IMPLIES EMERGENCY BALLAST WITH BATTERY BATTERY PACK) aag4' CON NA"FQ' B SIGNALING BUZZER AD y e F C, R. LA"- 200A FUSED SWITCH 2O0A COMBINATION FUSED >'y LIGHTING TRACK WITH LIGHT FIXTURE TYPES AS INDICATED A��°°°+ Q� ? 99 R3 GOTHAM (1) 32W TT 277 32 RECESSED COMPACT FLUORESCENT DOWNLIGHT. IN 1 AMP RATING AND FUSE AMPS SWITCH/STARTER e e e e MIRROR LIGHTS SEE LIGHT FIXTURE SCHEDULE) LIGHTOLIER BATHROOMS Tq FRS TYPE AS SHOWN FRS OR EQUAL 3 NEMA 1 STANDARD MOUNTING HEIGHTS 5 OA LIGHT FIXTURE - CEILING / WALL MOUNTED. '-o• No.19731 ,°Q I (AFF, AFG, UNLESS NOTED OTHERWISE) A = LIGHT FIXTURE TYPE "A" `9pT 225A CIRCUIT BREAKER 225A COMBINATION CIRCUIT S1 TIED (1) 13W TT 277 13 SURFACE MOUNTED DECOTRATIVE LANTERN WITH OPAL A - 3P RATINGS AS SHOWN, 1 3P BREAKER/STARTER WALL WASHER LIGHT FIXTURE - ARROW INDICATES DIRECTION. OR PRE-APPROVED EQUAL WASPS AND COMPACT FLUORESCENT LAMPING. AT CASH/ I 3 POLE, UNO NEMA 1 ELECTRICAL 48" IA A = LIGHT FIXTURE TYPE "A" ANNUNCIATOR PANELS 4S" WALL MOUNTED LIGHT FIXTURE. T-T TRANSFORMER Dmnw COMBINATION DIGITAL A = LIGHT FIXTURE TYPE "A" S2 TIVOLI COVELUM LED 120 30 LED OR T5 FLUORESCENT CASEWORK LIGHT. FLY FISHING I°.�.1.°+I TX# ® CLOCK OUTLETS (CENTERLINE) 84" OR PRE-APPROVED EQUAL � -°� AS SHOWN RATINGS w w VOLT METER/ AMMETER CONTROLS (CENTERLINE) 48" ®A � EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED. A = LIGHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) BOTTOM) 80" S3 BK (1) 70W PAR30 277 70 POLE AND/OR SURFACE MOUNTED UL LISTED EXTERIOR EXIT SIGNS (WALL MOUNTED, Amp EMERGENCY BATTERY PACK LIGHT FIXTURE - CEILING/WALL MOUNTED. SE-63-BLP-9-1 1-A-XXX CMH GRADE PAR30 METAL HALIDE SPOT FIXTURE WITH SNOOT FDR? FEEDER IDENTIFICATION FIRE ALARM BELLS (EXTERIOR) 144" DO4 I_I OR PRE-APPROVED EQUAL AND GLARE CONTROL HONEYCOMB BAFFLE. TO LIGHT REFER TO FEEDER SCHEDULE FIRE ALARM CONTROL PANEL (DISPLAY) 60" (SEE LIGHT FIXTURE SCHEDULE) MOOSE. MOUNTING LOCATIONS AND REMOTE BALLAST TO GpR GROUND FAULT RELAY FIRE ALARM HORNS/STROBES (CENTERLINE) 84" ®A AFEA (AREA FOR EVACUATION ASSISTANCE) SIGN -CEILING/WALL MOUNTED, ARROWS BE DETERMINED. FINISH TO BE VERIFIED BY ARCHITECT FIRE ALARM PULL STATIONS (HANDLE) 48" AS INDICATED A = LIGHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) _ 03.13.07 REV.PER TOWN COMMENTS KK3 KIRK-KEY INTERLOCK B REMOTE BATTERY BACK-UP. TA AMERLUX 120 PENDANT MOUNTED 2 CIRCUIT TRACK WITH 8'-0" SHUNT TRIP INTERCOM (AFEA ONLY) 36" ❑ ® - 02.16.07 ADDENDUM ( ) ST INTERCOMS 48" � - oz.ls.o7 ADDENDUM HALO SUSPENSION SPACING. BLACK FINISH. GENERAL TRACK AMMETER, RANGE AS PANELS/PANELBOARDS (TOP) 48"72" - KV 02.13.07 ISSUE FOR PERMIT 8'-0", 12'-0", AND 16'-0" LENGTHS. SEE PLAN. FOR 12'0" SPECIFIED OR REQUIRED MISCELLANEOUS - KV 02.09.07 ISSUE FOR BID LENGTHS, USE (3) SUSPENSION POINTS 6'-0" O.C. O AMMETER SWITCH PHOTOCELLS 144" No B Date Description RECEPTACLES (CENTERLINE) 181. 1❑ ELECTRICAL PLAN NOTE CALLOUT T1 AMERLUX (1) 39W T6 MH 120 39 TRACK MOUNTED 39W T6 METAL HALIDE OBJECT FIXTURE O VOLTMETER SWITCH RECEPTACLES (EXTERIOR) 24" L.L. Bean HALO WITH ADJUSTABLE BEAM SPREAD KNOB, CONCENTRIC VOLTMETER, RANGE AS RECEPTACLES (GARAGES) 26" Oj PLUMBING EQUIPMENT DESIGNATION RING BAFFLE, ON/OFF SWITCH AND BLACK FINISH. SPECIFIED OR REQUIRED (CONTRACTOR FURNISHED AND INSTALLED) GENERAL MERCHANDISE LIGHTING RECEPTACLES IN EQUIPMENT ROOMS 48" REFER TO PLUMBING FIXTURE OR EQUIPMENT METERunUTY UTILITY METER (AS REQUIRED BY UTILITY) SCHEDULES REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) 48" W3 TMS (1) 32W CFL 277 32 GOOSENECK BRACKETED COMPACT FLUORSCENT SIGN D WATT-HOUR METER REMOTE INDICATING LIGHT (FINISHED AREAS) CEILING EQUIPMENT DESIGNATION D H100B LIGHT WITH ANGLED REFLECTOR. TO HIGHLIGHT SIGNAGE WH 15 "D" DENOTES DEMAND REGISTER, SAFELY SWITCHES 48" (OWNER FURNISHED, CONTRACTOR INSTALLED) t1AR 14 Mf OR PRE-APPROVED EQUAL AT ENTRY AND BEHIND REGISTERS. FINISH PER ARCHITECT. "15" DENOTES MINUTES OF DEMAND INTERVAL MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR STARTERS 48" CU SQUth WIniJDOr VERIFY 32W BALLAST OPTION WITH MANUFACTURER. -ff'l- CURRENT TRANSFORMER 1 FURNISHED AND INSTALLED BUILDING DEPARTMENT REMOTE BALLAST? RATING AS SPECIFIED OR REQUIRED SWITCHES (CENTERLINE) 48" UNLESS NOTED OTHERWISE) -3& POTENTIAL TRANSFORMER TELEPHONES (PUBLIC) 1 ® 48", 1 ® 36" DETAIL REFERENCE W4 TBD RATING AS SPECIFIED OR REQUIRED 1 (1) 32W CFL 277 32 COMPACT FLUORESCENT DECORATIVE OPAL SCONCE TELEPHONE OUTLETS (CENTERLINE) 18" M1 UPPER NUMBER INDICATES DETAIL NUMBER LOWER I TRANSIENT VOLTAGE SURGE SUPPRESSOR TELEPHONE TERMINAL BOARD BOTTOM 6" NUMBER INDICATES SHEET NUMBER ULTRA LIGHTS 9443-CFL OVER FITTING ROOM DOORS. TO LIGHT FITTING ROOM NSS (BOTTOM) OR PRE-APPROVED EQUAL HALL. FINISH PER ARCHITECT III GROUND CONNECTION TELEVISION OUTLETS 18" W5 TBD (1) 32W CFL 277 32 BATHROOM VANITY COMPACT FLUORESCENT DECORATIVE —ffN GROUND CONNECTION WITH TEST WELL OR PRE-APPROVED EQUAL SCONCE WITH OPAL LENS. MOUNT BETWEEN PUBLIC NOTE: BATHROOM MIRROS. SEE DETAIL PER ARCHITECT �ll GROUND ROD THIS IS A MASTER LEGEND AND NOT ALL -o III LIGHTNING ARRESTER SYMBOLS, ABBREVIATIONS, ETC. ARE EM1 AS SPECIFIED BY ARCHITECT INCLUDED 120/ 25 WALL MOUNTED INTERIOR EMERGENCY EGRESS - CONTACT (OPEN OR CLOSED) NECESSARILY USED ON THE DRAWINGS. 277 LIGHTING UNIT, WHITE FINISH, SELF-DIAGNOSTICS, NI-CAD BATTERY X1 LIGHTOLIER LED INCLUDED 120/ 5 UNIVERSAL MOUNT, EMERGENCY BATTERY, SELF TEST The Shops at Evergreen Walk75 Tamarack Ave LX-U-G-W-E-1 277 DIAGNOSTICS, WHITE WITH GREEN LETTERS Building C, Suite 75 X2 COOPER LIGHTING (2) 26W-TRT 277 52 MOUNT FIXTURE ABOVE DOOR, 10' AFF. PROVIDE South Windsor, CT 06074 SHAPER 90 MIN EMERGENCY BATTERY BACK-UP 682-WP-11"-CFL/2-277V-C LOCATED WITHIN SPACE. Electrical Symbol NOTES: 1. ALL EMERGENCY EGRESS LIGHTING SHALL HAVE A 90 MINUTE MINIMUM BACKUP BATTERY. Legend, Lighting 2. EMERGENCY BATTERY BALLAST SHALL HAVE A 1400 LUMEN MINIMUM OUTPUT. Schedule Checked By: om Job No: 06125.00 ENGINEER OF RECORD: E301 j Craig R . Lanham 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 TEL: 913-307-5300 FAX: 913-307-5400 WEB: VWfW.HENDERSONENGINEERS.COM 0650001687 tt FIRE ALARM GENERAL NOTES: FIRE SPRINKLER GENERAL NOTES: N FILL CUP FIRE ALARM SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL BE 1. SPRINKLER SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL BE ROOF OR CEILING ? RD 1. IN ACCORDANCE WITH NFPA 70 AND NFPA 72. SYSTEM SHALL ALSO IN ACCORDANCE WITH NFPA 13 AND NFPA 24. SYSTEM SHALL ALSO v� NOTIFICATION CIRCUIT MEET ALL APPLICABLE BUILDING CODES, FIRE CODES AND THE MEET ALL APPLICABLE BUILDING CODES, FIRE CODES AND THE UPRIGHT SPRINKLER EXPANSION REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND CHAMBER INSURANCE CARRIER. VERIFY REQUIREMENTS PRIOR TO BID INSURANCE CARRIER. VERIFY REQUIREMENTS PRIOR TO BID aTi SIGNALING LINE CIRCUIT SERVING SUBMITTAL. SUBMITTAL. E BRANCHLINE® SYSTEM INITIATING DEVICES m 2. INFORMATION ON CONTRACT DOCUMENTS IS GENERAL INFORMATION AND FOR 2. INFORMATION ON CONTRACT DOCUMENTS IS GENERAL INFORMATION m BID PURPOSES ONLY. LAYOUT SYSTEM, PERFORM REQUIRED CALCULATIONS AND FOR BID PURPOSES ONLY. LAYOUT SYSTEM, PERFORM REQUIRED o O WATER SUPPLY N AND COORDINATE WITH OTHER TRADES. CALCULATIONS AND COORDINATE WITH OTHER TRADES. NOTIFICATION CIRCUIT 3. PROVIDE ADDITIONAL MATERIALS AND LABOR REQUIRED DUE TO LACK OF 3. PROVIDE ADDITIONAL MATERIALS AND LABOR REQUIRED DUE TO LACK COORDINATION OR TO MEET AUTHORITY HAVING JURISDICTION AND INSURANCE OF COORDINATION AND TO MEET AUTHORITY HAVING JURISDICTION UPRIGHT SPRINKLER NOTIFICATION CARRIER REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. AND INSURANCE CARRIER REQUIREMENTS AT NO ADDITIONAL COST TO SCALE: 1 1 '8"= -0" APPLIANCE THE OWNER. 0 / POWER EXISTING FIRE ALARM REDUCED PRESSURE 4. CONNECT NEW FIRE ALARM EQUIPMENT TO LANDLORD FIRE ALARM PANEL. 120 V PANEL CONTROL PANEL BACKFLOW PREVENTOR PROVIDE ADDITIONAL FIRE ALARM EQUIPMENT, WIRING, RACEWAY, ETC., AS 4. PROVIDE MINIMUM ORDINARY HAZARD GROUP 2 DESIGN CRITERIA (0.20 \ARM10VER (TYPICAL) WITH SUPERVISED REQUIRED FOR A COMPLETE AND OPERATIONAL FIRE ALARM SYSTEM. GPM/SF OVER 1500 SF HYDRAULIC REMOTE AREA) THROUGHOUT OS&Y VALVES BUILDING UNLESS REQUIRED OTHERWISE. INCLUDE HOSE ALLOWANCE 5 CONNECTEDIRTO THEMLANDLORDNT SHALL BE FIRE ALARM SYSTEM. WITH AND AT BASE OF RISER. UPRIGHT DROP (TYPICAL) 5. LIGHT HAZARD DESIGN CRITERIA MAY BE USED IN REAR OFFICES, SPRINKLER DRAIN VALVE 6. PROVIDE AUDIBLE AND VISIBLE NOTIFICATION APPLIANCES AS RESTROOMS AND BREAK AREAS. HEATED AREA UNHEATED AREA INDICATED ON THE DRAWINGS. 6. COORDINATE PIPE ROUTING NEAR ELECTRICAL EQUIPMENT WITH NFPA 7. PROVIDE DUCT DETECTION AND SHUTDOWN FOR AIR 70. Ci FIRE ALARM RISER NOTES DISTRIBUTION SYSTEMS EXCEEDING 2000 CFM. DUCT SMOKE H a BRANCHUNE��O DETECTION SHALL TRANSMIT A SUPERVISORY SIGNAL TO THE 7. COORDINATE SPRINKLER TEMPERATURES NEAR HEAT-PRODUCING o RISER DIAGRAM IS SCHEMATIC IN NATURE. NOT ALL DEVICES ARE SHOWN. FACP. SOURCES WITH NFPA 13. 0 REFER TO PLANS FOR ACTUAL DEVICE AND EQUIPMENT QUANTITIES AND A 2 o u° OUTLET ON BRANCHLINE LOCATIONS. 8 COORDINAIMPAIRMENT. FIRE PROV DE FIRE SYSTEM WATCH AND/ORMODIFICATIONS INTERIM MINIMIZE PROTECTION 8 WRITTEN DOCUMENTATION THATDO NOT CONNECT TO RP PIN G SUPPLY BEEN UNTIL FLUSHPROVIDED WITH AND N DUCT QfTECTORS MAY HAVE INTEGRAL RELAYS FOR AIR HANDLING UNIT PROVIDE ADEQUATELY SIZED DRAIN FOR BACKFLOW PREVENTER MEASURES WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION, PRESSURE TESTED IN ACCORDANCE WITH NFPA 13. ,y "t . SHUT-DOWN AND FIRE/SMOKE DAMPER CONTROL. WIRING FOR THIS FUNCTION INSURANCE CARRIER OR OWNER. a U INSTALL BACKFLOW PREVENTER IN ACCORDANCE WITH LOCAL AND 9. COORDINATE ROUTING OF SPRINKLER PIPING WITH ARCHITECT. `� u m a SUSPENDED ACOUSTICAL HAS NOT BEEN SHOWN. COORDINATE WITH MECHANICAL SYSTEM INSTALLER. CEILING TILE STATE REQUIREMENTS. 9• FORWARD COMPLETED FIRE ALARM CERTIFICATE OF COMPLETION TO REFER TO PLANS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. THE OWNER. 10. FORWARD COMPLETED CONTRACTOR MATERIAL TEST CERTIFICATES as ra a w PENDENT SPRINKLER FIRE ALARM RISER 10. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. TO THE OWNER. SEMI—RECESSED PENDENT SPRINKLER DIAGRAM — ADDRESSABLE SYSTEM FIRE PROTECTION ANTI—FREEZE SYSTEM 11. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 6 SCALE: 1/8"=1 '-0" 5 SCALE: 1/8"=1'-0" (4NO SCALE FIRE PROTECTION PLAN NOTES: Ol LANDLORD PROVIDED FIRE ALARM CONTROL PANEL EARTHQUAKE BRACIING: VENDING MACHINE I EARTHQUAKE BRACING REQUIRED ON SPRINKLER PIPING BY BUILDING O2 LANDLORD PROVIDED MANUAL PULL STATION (VERIFY PROTECTIVE COVER CODE. CONTRACTOR TO VERIFY EARTHQUAKE BRACING INSTALLATION PROVIDED PER LOCAL AUTHORITY REQUIREMENT). MEETS NFPA 13-2002 INCLUDING TIA 02-1 AND MANUFACTURERS - O3 RECOMMENDATIONS. ADDITIONAL BRACING MAY BE REQUIRED DUE TO LANDLORD PROVIDED SMOKE DETECTOR FIELD ADJUSTMENTS, VARYING BRACING ANGLES, DISTANCES TO JOISTS, g g 0 0 0 0 0 0 O O I 0 0 ® EXTEND FIRE PROTECTION MAIN FROM EXISTING STUB-IN PROVIDED BY AUTHORITIES HAVING JURISDICTION, ETC. LANDLORD. VERIFY CONNECTION POINT LOCATION PRIOR TO BID. 0 0 0 0 0 0 I I 0 ( O PROVIDE SPRINKLER BELOW STARIWELL, ROUTE SPRINKLER PIPING TO WATER SUPPLY INFORMATION: � SPRINKLERS IN BIKE SHOP AS INCONSPICUOUSLY AS POSSIBLE INFORMATION DERIVED FROM CALCULATIONS Vv g I BY EFP INC. DATED 01/08/07 115 © ANTI-FREEZE SYSTEM IN THIS LOCATION. REFERENCE DETAIL 4 FOR S — — — — — I ADDITIONAL INFORMATION. SPRINKLER PIPING FROM INTERIOR TO STATIC PRESSURE: 90.0 PSI EXTERIOR AND SPRINKLER PIPING UNDER CANOPY SHALL BE HELD AS RESIDUAL PRESSURE: 70.0 PSI RTU 15 O O q E TIGHTLY AS POSSIBLE TO THE UNDERSIDE OF THE STRUCTURE. AT A FLOW OF: 1135 GPM 1 0 0 0 0 @1 0 I 0 F�101 7 0 0 I i 7 REFERENCE DETAIL FOR LOWER LEVEL SPRINKLER PLAN 0! O O 1 O 75 RTU 115 115 2 I O8 PROVIDE SUPERVISED GATE VALVE AND FLOW SWITCH TO ISOLATE STOCK ROOM 1 E A T Y TE zj ( 0 0 I 0 0 0 0 0 I ( 0 9 PROVIDE MANUAL PULL STATION AND REMOTE ANNUNCIATOR PANEL 75 VERIFY LOCATION WITH LOCAL AUTHORITY PRIOR TO INSTALLATION. I I 2X I O I 1 1 RETURNS I 15 O 0 15 - - - - - - O - - - -0 - - o - - o- - tt- O - - - -0 - -0 - - o O - - - - - O O O O - - O - - - - 15 - I - - - - - t - - - - - - - - - - - - - - - _ O L� O O O — — g i 15 I I� I g MGR'SI SUP ORT TEA tt SAFE TEUCO EMPLPYEE O O O O O O O O O O O OFFICE LOUNGE EMp R O I OFFICE 15 O 115 115 115 30 75 75 O O O O O O O O O O O O 0 0 o -0 15 I 1 1 S I C �, 3 O EN W ? 1 1 ? RTU RE TR OM 2 w IFACP e 2 RTU RTU I ® o W W 3 0 0 0 0 0 0 gp 0 0 0 4 D 0 0 0 0 0 0 0 0 I (D I tt 30 1 1 I il__ O - - - - - - - - - - - - - - - -�- - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - C 0 13 U 1 O O O O I O O O O O O I / \ O O O I O O 1 I I FS I I XE / �\/°E�./,•�./`// ' IIII i ROI � WC 101� /g P 2� 0.187N0i�0 115 115 115 115 IVOMEN SGR ESTR MM O OO O O O O O O O 0 O O E � -'s O O o \ \ 3 REAR OFFICES FIRE PROTECTION PLAN SCALE: 1/8 —1 0 15 .,-- ;, - 03.13.07 REV.PER TOWN COMMENTS ® 02.20.07 ADDENDUM p QA 02.16.07 ADDENDUM 0 o 0 0 0 . KV 02.13.07 ISSUE FOR PERMIT o 0 0 0 o 0 0 0 o 0 CTJ� ISSUE 0 0 No S Date D scrlptlo FORBID l� I - - - - - - - - - - - - - - — - — - - - - - — - - - - - - - - - - - - - - - - - - ]- - - - - - — - — - — - — - - - - - - � - - - - - � - - - L.L. Bean 115 115 115 115 115 5 > I I I I I I O O O O O O O O I O O O O O O O O o BIKE SHOP AND CASH WRAP FIRE PROTECTION PLAN p I I I I I I 20SCALE: 1/8"=1 '-0" MAR 14 2007 8au111 VVIrlomr 0 0 0 0 I 0 -,''� RTU ,0'` 1 0 0 0 0 0 RTU 0 0 0 0 0 BUILDING DEPA RTMENT 8 VS RTU i g D IMEN'S FITTING 6 a jam - FP1 7 1 I I FIRE SPRINKLER LEGEND ROOMS / 0. SEMI-RECESSED PENDENT WITH MATCHING ESCUTCHEON ' �-�� 0 BRASS UPRIGHT SPRINKLER \ C CONCEALED PENDENT SPRINKLER EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL WOMEN'S FITTING DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" 30 ( �CA4iAP \ 115 CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL The Shops at Evergreen Walk \ 0 @ I ROOMS UPRIGHT SPRINKLER SUPPLIED FROM ANTI-FREEZE SYSTEM I EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. 75 Tamarack Ave lx TZ TX D 5 30 CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK 115 ;� O O 15 Z1 PENDENT SPRINKLER SUPPLIED FROM ANTI-FREEZE SYSTEM AND DEMOLffION WITH ALL OTHER DISCIPLINES AND Building C, Suite 75 O O O 0 0 O d O O O O \ Q7 EXISTING CONDITIONS. South WIndSOr, CT 06074 15 Av. FIRE ALARM LEGEND EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A eo— — _ — — _ - - _ - - - - - _ — _ —p _ _ _ _ _ — _ _ — _ — _ — _ _ _9 — _ _ _ _ _ _ _ _ — - _ — _ _ — _ _ THOROUGH KNOWLEDGE OF ALL DRAWINGS AND Fire Protection Plan — — — FA APQ " , 1 X( NUMBER INDICATES CANDELA WALL MOUNTED VISIBLE NOTIFICATION APPLIANCE SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO BECOME FAMILIAR WITH THIS KNOWLEDGE DOES - — --------- r- - 15 NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE _ _ _ _JD I CEILING MOUNTED VISIBLE NOTIFICATION APPLIANCE WORK PROPERLY. NO ADDITIONAL COMPENSATION - - - - - - - - - — - - - - - - - - - - - - — - — - — - — - — - — - — - - - - - - - - - - - - - - - - - - - - — - - - -r - - 9 ® SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT IFNUMBER INDICATES CANDELA OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS 9 I 15 WITH THIS KNOWLEDGE. WALL MOUNTED AUDIBLE/VISIBLE APPLIANCE lx(y I ( 15 NUMBER INDICATES CANDELA; "C" INDICATES CHIME Checked By: Ms n^ CEILING MOUNTED AUDIBLE/VISIBLE APPLIANCE Job No: 06125.00 i I NUMBER INDICATES CANDELA; "C" INDICATES CHIME 15 DUCT MOUNTED SMOKE DETECTOR SD SD INDICATES SUPPLY DUCT FLOW SWITCH �*i('��j��� l� Q TAMPER SWITCH 1 ENGR +�M OF IMCOM: FP1 01 0 FIRE ALARM ANNUNCIATOR PANEL Duane S . Henderson FAAP 8325 LENEXA DRIVE SUITE 400 LENEXA, KS. 66214-1695 1 ROOF DECK LEVEL FIRE PROTECTION FLOOR PLAN TEL: 9: WWW.HENDE FAX: NEERS.7-5400 MANUAL PULL STATION, PROVIDE PROTECTIVE COVER PER LOCAL WEB: WJWJ.HENDERSONENGINEERS.COM SCALE: 1/8"=1'-0" N AUTHORITY REQUIREMENT 0650001687