HomeMy WebLinkAbout661 Avery Street - Life Safety System Te (4) DYNAMARK SECURIrY *Quafity MEMO CENrERS Alarm Systems TM Since 1985 P.O. Box 1170 "Nationally Known, Locally Owned" Tolland, CT 06084-1170 LIC #181641 Tel. (860) 872-4050 Fax (860) 875-0493 Avery Street Christian Reformed Church DynamarkCT@comcast.net 661 Avery Street South Windsor, CT 06074 Date: 5/3/2011 RE: ANNUAL FIRE ALARM TEST Attached is a copy of the "INSPECTION AND TESTING FORM". This form was completed upon testing the fire system in your building, as required annually. A copy must be kept in a file on the property for a minimum of three [3] years and available if asked for by a building official or fire marshal. �A ;"P' Michael G Casieri CC: Fire Marshal WO#2119 Blessed 6e the Lord my roc( my refuge and my fortress, my stronghold, my deliverer, my shiefd in whom I trust. PSALM 144 72-111 INSPECTION TESTING AND MAINTENANCE INSPECTION AND TESTING FORM WO#: 2119 DATE: SERVICE ORGANIZATION PROPERTY NAME(USER) NAME: Dynamark Security NAME: Avery Street Christian Reformed Church ADDRESS: P.O. Box 1170 Tolland,CT 06084-1170 ADDRESS: 661 Avery Street REPRESENTATIVE: Michael G.Casieri South Windsor,CT 06074 LICENSE NO.: 181641 TELEPHONE: (860)644-2731 TELEPHONE: (860)872-4050 CONTACT: David Hiskes CHECK HERE IF MAILING ADDRESS IS DIFFERENT❑ MONITORING ENTITY APPROVING AGENCY CONTACT: CMS CONTACT: South Windsor Fire Marshal TELEPHONE: 1-800-432-1429 ADDRESS: 1540 Sullivan Avenue South Windsor,CT 06074 MONITORING ACCOUNT#: FLRPS1562 TELEPHONE: (860)644-2511 ext.217 TYPE TRANSMISSION SERVICE ❑-McCulloh ❑-Weekly ❑-Multiplex ❑-Monthly ®-Digital ❑-Quarterly ❑-Reverse Priority ❑-Semi-Annually ❑-R F ®-Annually ❑-Other(Specify) ❑-Other(Specify) PANEL MANUFACTURER:Notifier MODEL NO.: SFP 1024 DATE INSTALLED: Unk. CIRCUIT STYLES: B NO.OF CIRCUITS: 10 SOFTWARE REV.: LAST DATE SYSTEM HAD ANY SERVICE PERFORMED: Fire Test 4/6/2010 ALARM INITIATING DEVICES AND CIRCUIT INFORMATION QTY CKT. STYLE 6 B MANUAL STATIONS ION DETECTORS PHOTO DETECTORS 2 B DUCT DETECTORS HEAT DETECTORS I B WATERFLOW SWITCHES 1 B SUPERVISORY SWITCHES 1 B OTHER:ANSUL SYSTEM 72-113 f INSPECTION TESTING AND MAINTENANCE Prima (Main):Nominal Voltage 120v AC ,Am s: 15 Overcurrent Protection Type ,Amps: Location(Panel Number): Basement Panel"C"Circuit#40 Disconnecting Means Location: Circuit Breaker-Panel in Basement b. Secondary(Standby): Storage Battery#1: Amp-Hr.Rating: VDC: AH: Installed: Storage Battery#2: Amp-Hr.Rating: VDC• E AH: <d Installed: Calculated capacity to operate system,in ho rs: 24 1 60 Engine-driven generator-dedicated to fire alarm system: Location of fuel storage: TYPE BATTERY ❑Dry Cell ❑Nickel Cadmium ®Sealed Lead-Acid ❑Lead-Acid []Other(Specify) c. Emergency or standby system used as a backup to primary power supply,instead of using a secondary power supply: ❑Emergency system described in NFPA 70,Article 700 ❑Legally required standby described in NFPA 70,Article 701 []Optional standby system described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701. PRIOR TO ANY TESTING NOTIFICATIONS ARE MADE: YES O I WHO TIME MONITORING ENTITY ❑ BUILDING OCCUPANTS BUILDING MANAGEMENT ❑ ❑ OTHER(SPECIFY) ❑ I ❑ AHJ(NOTIFIED)OF ANY IMPAIRMENTS ❑ I ❑ SYSTEM TESTS AND INSPECTIONS TYPE VISUAL FUNCTIONAL COMMENTS CONTROLPANEL ❑ ❑ INTERFACE EQ. ❑ LAMPS/LEDS ❑ ❑ FUSES ❑ ❑ PRIMARY POWER SUPPLY ❑ TROUBLE SIGNALS ❑ ❑ DISCONNECT SWITCHES ❑ ❑ GROUND FAULT MONITORING ❑ ❑ SECONDARY POWER TYPE VISUAL FUNCTIONAL COMMENTS BATTERY CONDITION ❑ LOAD VOLTAGE ❑ DISCHARGE TEST ❑ CHARGER TEST ❑ SPECIFIC GRAVITY ❑ � H 72-115 INSPECTION.TESTING.AND MAINTENANCE SPECIAL PROCEDURES J COMMENTS: ON/OFF PREMISES MONITORING YES NO TIME COMMENTS ALARM SIGNAL ❑ ALARM RESTORAL ❑ TROUBLE SIGNAL ❑ SUPERVISORY SIGNAL Er ❑ SUPERVISORY RESTORAL ❑ ❑ NOTIFICATION THAT THIS YES NO WHO TIME TESTING IS COMPLETE: BUILDING MANAGEMENT [�- ❑ MONITORING AGENCY ❑ !�� ' BUILDING OCCUPANTS ❑ ❑ OTHER(SPECIFY) ❑ 1 ❑ THE FOLLOWING DID NOT OPERATE CORRECTLY: SYSTEM RESTORED TO NORMAL OPERATION: DATE jj TIME THIS TESTING WAS PERFO D INYC RDANCE WITH APPLICABLE NFPA STANDARDS. NAME OF INS EC OR: �/ � DATE: r SIGNATURE: NAME OF OWNER OR REPRESENTATIVE: E L/ k-,d DATE: ! b SIGNATURE: