HomeMy WebLinkAbout90 Wendy Drive *Wf*, -
S.
Town of South Windsor — Health Department
1540 Sullivan Ave.,South Windsor,CT 06074—Mailing Address
1530 Sullivan Ave.,South Windsor,CT 06074—Office Address
Phone Number: (860)337-6173, Fax Number: (860)6"-1930
B100a APPLICATION
(for building conversion,change of use,building addition,accessory structure and lot line change)
Standard application review time is 5-10 days,if soil testing is needed,additional time will be required to complete the
review process.
Street Address of Pro sed Activity/Structure
Owner iNarne Mailing Address Telephone
App cant Name(if different than owner) Mailing A dress Telephone
Describe the proposed structure or activity with dimensions:
Residential Number of existing bedrooms
Non-residential Please describe
Property served by on-site well? Y N If No,List name of water company
Property served by septic system?6) N Age of system Date last pumped
Plot plan—attach a scaled drawing showing property lines and dimensions, location and size of existing and proposed
structures, and site features such as driveways,wells and septic systems, drains and water courses.
Building plan—attach a sketch/floor plan of the proposed structure,addition or renovation showing existing and proposed
rooms with door and window locations.
Soil test data(deep test pits and percolation test) are required for the review of this application.
If the data is NOT available,you will need to schedule an appointment with the health department for soil testing.
As property owner or duly authorized representative of the property owner of the above referenced property.I agree to allow the health
department staff to enter the above referenced property as part of this B 100a application review process.I further agree that this
authorization to enter the subject property may extend through a period of time ending with the final B 100a application approval and affirm
such with my signature below.
E
Applicant Signature: Date: ��
FOR OFFICE USE ONLY: i
Approved: oY N By: `� ] Ab S , - Date• Z 1
Comments/Conditions: 4 g 0ol r Add ikiOtA Q^t, . Y1d cLP C_AL
FEE PAID: % CHECK# DATE PAID:
Rev.7/16/18
FOR OFFICE USE ONLY
Application Complete: Notes:
Form:
Plot Plan:
Building Plan:
Info Needed:
Soil Data Available: Notes:
Test Pits:
Perc Test:
Need Soil Data Y N
Activity Code Complying Area found Y N
Building Conversion: Will proposed change result in expanding system? Y N
Change in Use: Notes:
Addition w/ Increase:
Addition w/o Increase:
Addition w/o Increase OR potential repair area found that meets the following:
1. Replacement area provides 50%of ELA Y N
2. Replacement area provides 50%of MLSS Y N
3. No exception(s)to well separation distance Y N
4. Does not reduce the potential repair area Y N
5. Does not increase design flow of building Y N
Accessory Structure Code complying area? Y N
Potential repair area identified? Y N
Lot size reduction Code complying area? Y N
Lot line change
General info Will this negatively impact existing SSDS? Y N
Will this negatively impact existing well(s)? Y N
Area separation distances approved: Y N
Notes:
Page i of 1
x' Volume 520 Page N° 095
SCHEDULE A DESCRIPTION
90 Wend rive
South WWindsor, CT.
4 "
A certain piece or parcel of'land, with the buildings thereon,
F situated in the Town of South Windsor, County of Hartford and
State of Connecticut, located on the southerly side of Way
Drive, being Lot No. 38 an a trap entitled •Property of ROLLING
PARR HOMES, INC., South Windsor, Conn. Scale 1" - 60' January 14,
1957", which map is on file in the Town Clerk's Office in said i
Town of South Windsor, to which reference may be had, and being
more particularly bounded and described as follows, to wits
NORTHERLY: by Wendy Drive, one hundred one (101) feet;
EASTERLY: by Lot No. 39 on said map, one hundred $ !
sixty (160) .feet; Lr
SOUTHERLY: by Lot No. 26 on said map, One hundred'*
�j twenty-six (126) feet;
t
WESTERLY: by June Drive, One hundred thirty-five {1331 �
feet; and t ,
NORTHWESTERLY: by a curve connecting the easterly line of
June Drive with the southerly line of Wendy
Drive, thirty-nine and twenty-seven ?
fone-hundredths (39.27) feet.
I
Said premises. are also known as 92 Wendy Drive, South Windsor,
Connecticut.
V9R mom
Volume: 520" Page: 94 File Number: 001607 'Seq: -
t04N Sf4< O-P �.
s 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074
4'tioSOR.coN�` TELEPHONE (860) 644-2511
February 7, 2019
GAP Carpentry Services, LLC
Attn:Gary Pelletier
549 Ellington Rd.
South Windsor,CT 06074
B-100 APPLICATION
Street address:90-92 Wendy Dr. Town:South Windsor,CT 06074
Dear Mr. Pelletier:
On February 7,2019,this department received an application proposing an addition to the property listed above.
Based on the information provided and paperwork in our files this request has been approved under the following
conditions:
Maintain a minimum 10 feet distance from the existing septic tanks and leach fields from the proposed addition.
Please note that the "proposed deck"on the submitted drawing was not part of the application and is not covered
under this approval letter. The separation distance to septic systems for accessory structures is 10 feet. If the
structure is without full wall,frost protected footings the distance shall be reduced to 5 feet.
Approval is being granted under Section 19-13-13100a of the CT Public Health Code. This approval is given with the
understanding that you will provide proper care and maintenance of the existing system(the septic tank is to be
pumped every 3 years).
THE OWNER IS RESPONSIBLE TO SEEK PROPER AUTHORIZATION FROM ALL TOWN AGENCIES PRIOR TO START OF
CONSTRUCTION.
Should you have any questions,please do not hesitate to contact this office at(860)337-6173.
Sincerely,
Heather Oatis,REHS
Environmental Health Officer
cc:South Windsor Building Official
South Windsor Town Planner