Loading...
HomeMy WebLinkAbout344 Beelzebub Road UAquatek Labs 3 Research Drive-Woodbridge, CT 06525 Water Analysis Report TEST ID: B050118306 DATE SAMPLED: 4/30/2018 TO: PRIME HOME INSPECTIING, LLC 597 SAMPLE POINT: KITCHEN NO TREATMENT SAMPLED BY: ARTHUR ANNECHARIO PROPERTY LOCATION: 344 BEELZEBUB ROAD-SOUTH WINDSOR , CT BACTERIA ABSENT PRESENT LIMITS REF METHOD Coliform(Total) G 0 ABSENT P SM 9223 E.Coli(Fecal) G ❑ ABSENT P SM 9223 Chlorine(Total) G ❑ ABSENT - SM 4500-CI G PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL REF METHOD pH 8.0 SU 6.4-10 S 0 SM 4500-H B Turbidity 0.45 NTU 5 0.10 SM 2130 B Color ND CU 15 S 5 SM 2120 B Odor 0 TON 2 S 0 SM 2150 CHEMICALS RESULT UNITS LIMITS MRL REF METHOD Fluoride ND mg/L 4 P 0.3 EPA 300.0 Chloride 29 mg/L 250 P 3 EPA 300.0 Nitrite Nitrogen ND mg/L 1 P 0.1 EPA 300.0 Nitrate Nitrogen 1.9 mg/L 10 P 1 EPA 300.0 Sulfate 7 mg/L 250 S 4 EPA 300.0 Calcium 33 mg/L NONE 0.5 EPA 200.7 Magnesium 4 mg/L NONE 0.5 EPA 200.7 Hardness 98 mg/L 200 S 4 SM 2340 B Sodium 7.0 mg/L 100 S 0.5 EPA 200.7 Copper ND mg/L 1.3 S 0.04 EPA 200.7 Iron ND mg/L 0.3 S 0.04 EPA 200.7 Manganese ND mg/L 0.05 S 0.04 EPA 200.7 RADON WATER SINGLE RESULT UNITS LIMITS MRL REF METHOD Radon Water Single 503 pCi/L 5000 S 51 SM 7500-RN CONCLUSION: Based on the above results, this water was safe for drinking purposes at the time of collection. P=Primary limit,used to judge potability S=Secondary limit,recommended but not required / /� MRL=Minimum Reportable Level �Iel ai4a�--.0, W Limit exceeded Michael F. Berman, Ph.D. ND=None Detected Laboratory Director CT License#PH-0466,Aquatek Labs R=Reference Lab Work Page 1 of 1 for test# B050118306