HomeMy WebLinkAbout637 Deming Street UAquatek Labs
3 Research Drive-Woodbridge, CT 06525
Water Analysis Report
TEST ID: B030618302
DATE SAMPLED: 3/5/2018
TO: PRIME HOME INSPECTIING, LLC 597 SAMPLE POINT: KITCHEN
AFTER TREATMENT
SAMPLED BY: JASON LIMA
PROPERTY LOCATION: 637 DEMING STREET- SOUTH WINDSOR , CT
BACTERIA ABSENT PRESENT LIMITS REF METHOD
Coliform(Total) G ❑ ABSENT P SM 9223
E.Coli(Fecal) G ❑ ABSENT P SM 9223
Chlorine(Total) G ❑ ABSENT SM 4500-CI G
PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL REF METHOD
pH 7.2 SU 6.4-10 S 0 SM 4500-H B
Turbidity 3.80 NTU 5 0.10 SM 2130 B
Color 9 CU 15 S 5 SM 2120 B
Odor 0 TON 2 S 0 SM 2150
CHEMICALS RESULT UNITS LIMITS MRL REF METHOD
Fluoride ND mg/L 4 P 0.3 EPA 300.0
Chloride 37 mg/L 250 P 3 EPA 300.0
Nitrite Nitrogen ND mg/L 1 P 0.1 EPA 300.0
Nitrate Nitrogen ND mg/L 10 P 1 EPA 300.0
Sulfate 5 mg/L 250 S 4 EPA 300.0
Calcium 67 mg/L NONE 0.5 EPA 200.7
Magnesium 14 mg/L NONE 0.5 EPA 200.7
* Hardness 224 mg/L 200 S 4 SM 2340 B
Sodium 10.0 mg/L 100 S 0.5 EPA 200.7
Copper ND mg/L 1.3 S 0.04 EPA 200.7
* Iron 1.91 mg/L 0.3 S 0.04 EPA 200.7
* Manganese 0.88 mg/L 0.05 S 0.04 EPA 200.7
RADON WATER SINGLE RESULT UNITS LIMITS MRL REF METHOD
Radon Water Single 1276 pCi/L 5000 S 51 SM 7500-RN
CONCLUSION: Based on the above results, this water was safe for drinking purposes at the time of collection.
COMMENTS:* Filtration and/or conditioning are recommended.
P=Primary limit,used to judge potability
S=Secondary limit,recommended but not required
MRL=Minimum Reportable Level �� 3e�
Limit exceeded Michael F. Berman, Ph.D.
ND=None Detected Laboratory Director
CT License#PH-0466,Aquatek Labs
R=Reference Lab Work
Page 1 of 1 for test# B030618302