HomeMy WebLinkAbout655 John Fitch Blvd. (2) STATE OF CONNECTICUT - FOCUSED FOOD SERVICE INSPECTION REPORT - DEPARTMENT OF PUBLIC HEALTH
Establishment:LENA'S RESTAURANT Inspection Date:16-Nov-2017rime: 1:22 pm Re-inspection
ddress/Cit :0655 JOHN FITCH BOULEVARD,South Windsor Health Dept:South Windsor Class: 3
Based on an inspection this day,the items marked DNC identify the violations in operation or facilities which must be corrected by the date specified on page 2.
RISK FACTOR ITEMS:Listing is not inclusive of all possible debitable items KEY:C[compliant] N/O[not observed] N/A[not applicable]
DNC does not comply] O Jotherl RTE read -to-eat
01.Approved source,wholesome,nonadulterated 24c. Adequate clisnwasner sanitizer/Tinal rinse temp
01 a. Approved shellfish,finfish,meat and poultry USDA approved C roper sanitizing procedure
Food cans in good condition(not dented,rusty,bloated, 27377Sanitizing Between raw animal origin and ready-to-eat fo0
leaking)
c. Wholesome,nonadulterated foods,sae o• er
Commercial products no home grown or canned o0 25.Clean Wiping Cloths
25a. Cloths and/or sponges in good repair and clean C
e. Potentially hazardous foods receive a proper empera ure
o. Other aping c o s in ane ze ep s ir between uses 1-DNC
Z00. 1Uther
03.Hazardous Food Meets Temperature Requirements
03a. Hot holding greater than or equal to 140F(whole beef or pork C 26.Food-contact Surfaces Clean
roasts 130F) 26a. Food equipment clean,utensils clean,equipment interiors 2-DNC
Cold holding less than or equal o 45F clean
c. roper cooling o00 Single use gloves changed when soiled
c. oo -con ac su aces clean
Proper re-heating o 00
e. roper internal cooking and consumer advisory posted o. er
o. Other
30. Hot and cold water under pressure,provided as required
38.Handwashing Accessories Provided
04.Maintain Product Temp,Thermometers Provided 38a. Soap/paper towels/drying device available C
04a. Food thermometer available and accurate C
Dispenser(s)working-soap paper towels
roper food thermometer for product
c. Handwash sin s clean waste receptacle at handwaShsin .
c. Thermometers appropriately placed in cooler units
o. utner
o. Other
07.Food Protection 60. Qualified Food Operator
07a. Produce washed C 61. Designated Alternate
Raw meats not stored/prepared near ready-to-eat foo s 2-DNC 62• JWritten documentation of training program
c. ood covered properly 2-DNC e T011owing in orma ion is not debitable and does not attect your score.
Adequate splash guars sneeze guar KEY:QFO[qualified food operator],DA[designated alternate],
e.
PHF[potentially hazardous food], FB[foodborne]
o unau orize personnel
PHFs are hot held at:(Deg.F)
o pooling of eggs not cooked immediately PHFs are cold held at:(Deg.F)
U/0. JUther Are internal cooking temperatures taken?
09.Handling of Food Minimized To what temperature do you cook poultry(Deg.F)?
09a. No unnecessary handling RTE and/or cooked foods with bare C To what temperature do you cook ground beef(Deg.F)?
hands To what temperature do you cook pork(Deg.F)?
inimize oo an ing,o er an rea y-o-ea,withbare
hands To what temperature do you cook roasts(Deg.F)?
c. Adequate utensil(s)Tor dispensing Tood/ice 2-DNC To what temperature do you cook OTHER(Deg.F)?
o. Other Describe re-heating procedures:
Are temperatures recorded/logged for cold holding foods/equipment?
12.Personnel With Infection Restricted 12a. Food workers have no exposed infected lesions/burns C Are foods cooked in advance and cooled?
ersonne with infection restricted
Are leftovers saved?
List products cooled:
c. Communicable disease ot worker reported o local healthDescribe cooling methods:
director
13.Handwashing Facilities,Hands Washed,Clean Is cooling monitored for time and temp?
13a. Handwash facilities in all food prep/dispensing and warewash C Is the monitoring of cooling recorded?
areas Is there a produce washing policy?
Handwash facilities in or immediately adjacent o of a rooms U Describe what is washed and where:
c. Handwash facilities access bl a conven ient to use U Describe illness conditions when you would exclude a food worker from
Personnel nancis washed,clean roper handwash procedure working:
What diseases related to foodborne illness are you required to report to the
e. Handwashing at appropriate times local health department?
T377 u I n er Is there a written illness policy that requires the food worker to report specific
16.Good Hygienic Practices illness conditions and diseases to the QFO?
15a. No eating/No smoking while working C Do you have a paid sick leave policy?
oun s covere a equa e y C Is there a language barrier between inspector and QFO?
c. Proper sink used Tor handwashing IF YES,indicate language spoken by QFO/DA:
Can the QFO/DA read the inspection report?
o. Other Indicate who answered the above questions(Name):
24.Sanitization Rinse(hot water-chemical) Obtain signature of person who received the QFO responsibilities information
24a. Approved sanitizer available/adequate concentration of C at the time of the inspection:Signature on Page 2
sanitizer Indicate the title of the above person:(QFO,DA, Mgr,Cook,Owner,FW-
Food-contact surfaces and utensils used tor potentially type all that apply)
hazardous food sanitized at least every 4 hours
Inspection#A99 Note:This report is a two page form (total of 62 debitable items) Page 1 of 3
STATE OF CONNECTICUT-DEPARTMENT OF PUBLIC HEALTH -410 CAPITOL AVENUE-MS#51 FDP-HARTFORD, CT 06134
FOCUSED FOOD SERVICE INSPECTION REPORT
Local Health Dept:South Windsor Address/City: 1540 Sullivan Ave.
Establishment:LENA'S RESTAURANT Inspection Date:16-Nov-201
ddress: 0655 JOHN FITCH BOULEVARD Owner or Operator:Lena Lonero
ADDITIONAL FOUR POINT ITEMS OTHER ITEMS
KEY: DNC[DOES NOT COMPLY] KEY: DNC[DOES NOT COMPLY]
6.Foods Not Re-served 44. Floors:Floor covering installed,constructed as required,good 1-DNC
Unwrapped foods not re-served C repair,clean
Potentially hazardous foods not re-served 45. Floors graded,drained as required C
11.Toxic Chemicals 46. Floor,wall juncture covered C
Toxic chemicals stored properly,labeled properly,used properly C
Sanitizer concentration not to exceed maximum permitted 47. Mats removable,good repair,clean C
No unnecessary toxics on the premises 48. Exterior walking,driving surfaces,good repair,clean C
Pesticides/rodenticides properly dispensed
9.Water Source Adequate,Safe 49. Walls,ceilings attached,equipment properly constructed,good C
repair,clean.Wall and ceiling surfaces as required
Well/Well head protected from contamination C
Water quality in compliance 50. Dustless cleaning methods used,cleaning equipment properly 1-DNC
Monitoring in compliance stored
1.Sewage Disposal Approved 51. Adequate lighting provided as required C
Sewage disposal operating as required C 52. Room free of steam,smoke odors C
4.No cross connections, back siphonage, backflow
Proper type/installation/backflow prevention device/air gap for: C 53. Rooms and equipment hoods,ducts,vented as required C
ood equipment,soda system carbonator,chemical dispensers,hose 54. Rooms adequate,clean,adequate lockers provided,facilities C
onnections,beverage dispensers,ice and dish machines,toilet tanks clean
Proper drain for:food equipment,dish and ice machines 55. Establishment and premises free of litter,no insect/rodent C
5.Toilet Facilities harborage,no unnecessary articles
Toilet facilities adequate,convenient,accessible,designed, C 56. Complete separation from living/sleeping quarters and laundry C
properly installed
OTHER ITEMS 57. Clean/soiled linens stored properly C
58. No live birds,turtles,or other animals(except guide dogs) C
KEY: DNC[DOES NOT COMPLY] 59. Seats 75 or more: Nonsmoking area provided,sign(s)posted C
02. Sources of food-original container,properly labeled C at entrance(s),smoking area indicated by sign(s)
05. Potentially hazardous food properly thawed C Re-inspection
10. Food dispensing utensils properly stored 1-DNC
14. Food worker:Clean outer clothes,effective hair restraints C DEMERIT SCORE
16. Food-contact surfaces designed,constructed,maintained, 2-DNC '4' '3' '2' TV wing
installed,located 0 0 1 4 1 5 1 13 87
17. Nonfood-contact surfaces designed,constructed,maintained, 1-DNC Date Corrections Due: 30-Nov-2017
installed,located Person in Charge: Lena Lonero
18. 1 Single service articles,storage,dispensing C Name, Title,
Manager
19. No reuse of single service article C Signature
20. Dishwashing facilities approved design,adequately C
constructed,maintained,installed,located
21. Equipment and utensils-preflushed,scraped,soaked and C
racked
22. Equipment and utensils-wash water clean,proper C
temperature Inspector: Melissa Pierce[1043]
23. Equipment and utensils-accurate thermometers provided, C Name,Signature,
dish basket,if used Phone Number 860-337-6182
27. Nonfood-contact surfaces of utensils and equipment clean C
28. Equipment/utensils,storage,handling C
32. Proper disposal of waste water C
33. Plumbing location,installation,maintenance C
36. Toilet rooms enclosed with self-closing door C
37. Proper toilet fixtures provided,good repair,clean C
39. Approved garbage/rubbish containers,adequate number, C
covered,rodent proof,clean
40. Garbage/rubbish storage area/rooms,enclosures-properly C
constructed,clean
41. Garbage/rubbish disposed of in an approved manner,at C
approved frequency
42. Vermin Control:No insects/rodents present C
43. Outer openings protected against entrance of insects/rodents C
Inspection#:499 Note:This report is a two page form (total of 62 debitable items) Page 2 of 3
RANSr4�/
_ r
INSPECTION REPORT STATE OF CONNECTICUT
FOOD SERVICE ESTABLISHMENTS DEPARTMENT OF PUBLIC HEALTH
CONTINUATION SHEET
Name of Establishment Town Date of Inspection
LENA'S RESTAURANT South Windsor 16-Nov-2017
INSPECTION REMARKS
FORM#
07b. Raw meat stored above or adjacent to RTE foods
Raw seafood stored above chicken stock/cooked veggies in WIC
07c. Food Protection-Other
Salad mixing bowl nesting in bin of lettuce in reach-in
09c. Cup or container with no handles used as food scoop
Spices
10. In-use utensils stored in hot water bath less than 140°F and/or bath is dirty
Scoop handle sitting in salt
16. Excessive ice build-up in reach-in freezer
17. Non Food-Contact Surfaces
Deteriorated W IF doors; rusty dry storage shelving
25b. Moist wiping cloths not held in required concentrations of approved sanitizing solution between uses
26a. Interior of reach-in refrigerator unclean
Slicer unclean
44. Ice on freezer floor
Floors in WIC deteriorated; sauce spill on WIC floor;floors littered throughout
50. Mops not hung to air dry
Hot hold -meatballs- 162f, marinara 158F, soup 165
Cooking-marinara- 186F
Cold hold -cut tomato-41 F, chicken 37F, sauce 38F, deli meat 35f, meatballs 35F, garlic in oil-37F
WIC-cut tomato 37F chicken stock 36Fpasta 37F
Inspection*499 Note:This report is a two page form (total of 62 debitable items) Page 3 of 3