Loading...
HomeMy WebLinkAboutApplication 178 Chapel Road �° °"' °;•<� Town of South Windsor — Health Department 1540 Sullivan Ave., South Windsor, CT 06074— Mailing Address 1530 Sullivan Ave., South Windsor, CT 06074—Office Address Phone Number: (860) 337-6173, Fax Number: (860) 644-1930 APPLICATION FOR APPROVAL TO CONSTRUCT A SUBSURFACE SEWAGE DISPOSAL SYSTEM / l Application/Permit#: To the Director of Health,Town ,,f: J o �'^ W ��sw Date: 3 z- '7 Application is hereby made for an approval to construct a subsurface sewage disposal system for a: (Residential Buildin Restaurant,Retail Building,etc.) located at: •iJel 17 (Str et Address,Lot Number,Subdivision Name,Map,Block,Lot,etc.) New System �/f Addition_ Repair Other Owner Jrss,<< A //I e s Address /7 f �h./�� "' Tel.No. Installer J(/./�5 / s'euRTCr Address L t °�� ^� D/ Tel.No. Installer License No. In accordance with detailed information stated below: Application fee paid Signed (Owner or duly authorized rep esentative) ------------------------------------------------------------------------------------------------------------------------------------- GENERAL INFORMATION Soil Tests Conducted(Date): 3o y Lot size sq.ft. Area of Special Concern (Y/N): f yes,Reason(s): Basis of Design(#of Bedrooms,Restaurant Seats,Building Size,etc.): Z r?<<�r Engineered Plan Required(Y/N): /U` If yes,Name of Engineer: Address of Engineer: Design Plan Approved(Y/N): n Date of Approved Plan: Revision Date: Type of Water Supply �' '✓/ �/e // If well,has location been approved(V110: Well Driller's Name: Address: OFFICE U ON Approval to Construct issue `by: / v Date: irector of He or Registered Sunitu an) Signature: Title: //L b' Ov-_S RECE11 D APR 0 3 2017 SOUTH WINDSOR HEALTH DEPT. Jessica Magalhaes `\ 178 Chapel Rd 9s.000 97.60 South Windsor CT 151+ TP3 a 5 50' Design Criteria: �C N E \ 2 Bedroom house, 1-10min/in perc, 30" o M restrictive layer, 3.5% slope N d D Perc 2 \ MLSS- 30x1.Ox1.2=36' f n \ \ \ BM o \\ Proposed: 100.00 0 7' \ TP2 Install a new 1000 gallon septic tank and a new 1000 gallon pump chamber Silt Fence with a 1/3hp effluent pump with an 8.00 p97.60 9 alarm. Install 2-54' rows of Quick Fours with 2"sch40 pvc o stone for a total of 388sgft.Trench bottoms to be 12" into grade max and fp. installed in select septic sand. All topsoil will be removed prior to filling with select sand. .�' O 1000 Gallon Pump Chamber All separating distances will be met. slope 3.596 O •1000 Gallon Tank o Risers to grade 4"sch40 pvc 1/4"per ft RECEIVED t = 0 i 2017 SOUTH WWNDSOR HEALTH DEPT. Cc Deck #178 2 Bdrm Driveway Plan By: Andrew Coleman Well Skips Wastewater Services Inc Lic# 5839 178 Chapel Rd South Windsor Riser Above Grade Pump Chamber Detail Union Meyers ME3F11 1/3hp Effluent Pump 7"Tether, 20gal/inch, 140 Gal/Dose 1 ep H le m C7 0 Check Valve Alarm Alarm Float Pump On m Stop/Start Float Pump Off RECEIVED �,po 0 1 2017 SOUTH WINDSOR FILTH DEFT.