HomeMy WebLinkAbout2017-5-12 - 169 Avery Street - Water Potability Test UAquatek Labs
3 Research Drive-Woodbridge, CT 06525
Water Analysis Report
TEST ID: F051317002
DATE SAMPLED: 5/12/2017
TO: OASIS INSPECTION SERVICES, LLC 747 SAMPLE POINT: BATHROOM
NO TREATMENT
SAMPLED BY: ERIC ROWE
PROPERTY LOCATION: 169 AVERY STREET - SOUTH WINDSOR , CT
BACTERIA ABSENT PRESENT LIMITS REF METHOD
Coliform(Total) G ❑ ABSENT P SM 9223
E.Coli(Fecal) G ❑ ABSENT P SM 9223
Chlorine(Total) G ❑ ABSENT SM 4500-CI G
PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL REF METHOD
pH 6.6 SU 6.4-10 S 0 SM 4500-H B
Turbidity 0.50 NTU 5 0.10 SM 2130 B
Color ND CU 15 S 5 SM 2120 B
Odor 0 TON 2 S 0 SM 2150
CHEMICALS RESULT UNITS LIMITS MRL REF METHOD
Fluoride ND mg/L 4 P 0.3 EPA 300.0
Chloride 38 mg/L 250 P 3 EPA 300.0
Nitrite Nitrogen ND mg/L 1 P 0.1 EPA 300.0
Nitrate Nitrogen 3.1 mg/L 10 P 1 EPA 300.0
Sulfate 14 mg/L 250 S 4 EPA 300.0
Calcium 17 mg/L NONE 0.5 EPA 200.7
Magnesium 3 mg/L NONE 0.5 EPA 200.7
Hardness 55 mg/L 200 S 4 SM 2340 B
Sodium 19.1 mg/L 100 S 0.5 EPA 200.7
Copper 0.19 mg/L 1.3 S 0.04 EPA 200.7
Iron ND mg/L 0.3 S 0.04 EPA 200.7
Manganese ND mg/L 0.05 S 0.04 EPA 200.7
CONCLUSION: Based on the above results, this water was safe for drinking purposes at the time of collection.
P=Primary limit,used to judge potability
S=Secondary limit,recommended but not required
MRL=Minimum Reportable Level'
Limit exceeded Michael F. Berman, Ph.D.
ND=None Detected Laboratory Director
CT License#PH-0466,Aquatek Labs
R=Reference Lab Work