HomeMy WebLinkAboutInspection 99 Mill Pond Drive routine Inspection 0 Indoor Pool
Town of South Windsor-Health Department 0 Re-inspection 'Outdoor Pool
1540 Sullivan Avenue,S.Windsor,CT 06074
0 Complaint 0 Wading Pool
Phone: 860-337-6182 Fax: 860-644-1930 0 Other. 0 Whirlpool/Spa
Public Swimming Pool Inspection Report
Name of Facility: _, ��C1 Inspection Date:
Address: ?q A/4 je-h Phone:
Items marked with an X indicate non-compliance with CT Public Health Code(Section 19-13-1333b). Violations must be corrected by the listed compliance date.
a-4 Life Saving Equipment b-12 Vacuuming
Ring buoy <15" inner diameter, attached to
50ft length of%" line Pool vacuumed to maintain cleanliness
b-13 Accessibility to Pool Area
Life pole/shepard's crook with blunted ends, a Outdoor pools surrounded by barrier(>4ft)
minimum of 12ft in length
b-1 Pool Construction Outdoor pool entry gates self-closing and self-
Pool in good repair ✓ latching
b-2 Supervisory Personnel i Pool access restricted when pool is closed
Knowledgeable pool supervisor onsite b-14 Lifeguards
List of personnel provided to Health Dept. Warning signs if no lifeguard on duty(letters
b-4 Pool Water Clarity >4" high)
6" secchi disk at pool bottom visible Warning signs visible from all entry points in
b-5 Pool Water Disinfection pool area
Automatic Feeder Used )2. A CIA,
b-15 First Aid Kit
>0.8 mg/liter Free Chlorine Kit filled, ready for use, materials current
(/b-5, b-6 Test Kits Amer. Red Cross 24-unit first aid kit or equiv.
DPD Test Kit onsite (for disinfectant and H) b-16 Emergency Telephone
b-6 Pool Water pH Telephone readily available in pool area
b-17 Signs
Value between 7.2 and 7.8 "All persons shall bathe with water and soap
b-7 Records and Testing before entering pool„
Residual disinfectant& pH tested prior to daily / "Anyone having a communicable disease shall
✓ opening v not use the pool"
jZ Daily pool testing records kept / "Spitting, or blowing the nose in the pool is
b-8 Decks, Dressing,Toilet&Shower Rooms 3 v prohibited"
Clean, good repair, well ventilated d "Running, boisterous or rough play is
0.5%chlorine cleaning solution for floors prohibited"
Shower water 90—105 degrees F b-18 Emergency Communications
L Adequate toilet facilities Directions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment ✓ posted at entrance
Maintained in good repair, clean/sanitary
� Telephone numbers (print>.25�,) of police, fire,
Skimmers,gutters, strainer baskets clean and in hospital and EMS
good repair b-19 Registration
Drain grates compliant Name of owner or owner's agent, address and
b-10 Deck Equipment location on file
/ Handrails provided on steps, step holes, and c-1 Depth Markers
ladders arkers on rim at min and max dq,pth and
Equipment properly secured points of slope change
b-11 Pool Chemical Storage Markers visible from pool deck and from within
Stored in a cool, dry, clean, well-ventilated area "Pool
(✓ Containers stored tightly closed
Public Swimming Pool Inspection Report
2
c-2 LifeguarOA45nds Comments:
Life rd stand raise least Oft Filter Type:laz f/�zz
eguard Stan ated pool side cent to
deep en Filter Size:_
c-4 Sign
/ "No diving is permitted off the deck into Flow Gauge (gpm):
shallow areas of the pool"
Additional Requirements for Public Spas: TO rate (vol./flowrate x 60):
e-1 Pool Water Disinfectio -� Filtration rate (gpm/sf):
Free available chlo ' e residual >1.0 mg/liter ,
when spa in u5e Free Chlorine Total: 49' 7
e-2 Pool Wate emperature /
Water mperature shall not excee 04 pH: D
deg es F
e-3 pth Markers
Minimum 2 markers Iota d on rim or
adjacent to pool /
e-4 Precaution Signs
"Elderly perso and those suffering from
Heart Disea ,Diabetes, High or Low Blood
Pressure all not enter the spa"
"Unsu ervised use by children is pro ' ited"
"D of use while under the infl nce of
cohol/drugs"
"Do not use alone"
"Observe a reasona a time limit (preferably
less than 15 mi long exposures may result
in nausea, di mess, or fainting"
e-5 Oils, Bod otions,and Soaps
Oils, dy lotions&soaps must be removed
prio to spa use
Pool Supervisor: ,x % ) A � �, � Date!
,1�. t
(Print Name)
(sign- 14 /
Health Inspector: Title:
(Signature)
DATE OF COMPLIANCE: / " /a"''—Re-inspection Required: YES NO
24e-u�
0
S Windsor—April 2011