Loading...
HomeMy WebLinkAboutApproved Design 2995 Ellington ROad SEPTIC SYSTEM DESIGN: SELECT FILL: / / \ W W RESERVE AREA DESIGN CRITERIA EXISTING HOUSE LOT 1. THE FILL SHALL BE INSTALLED TO EXISTING GROUND ELEVATION. 0 z 2 DESIGN PERCOLATION RATE: 12.86 MIN IN 2. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN THREE (3) INCHES. / z (a REQUIRED EFFECTIVE LEACHING AREA = 900 SF 3. UP TO 45% OF THE DRY WEIGHT OF THE REPRESENTATIVE SAMPLE MAY BE RETAINED ON THE #4 - GST 6212 SIEVE (THIS IS THE GRAVEL PORTION OF THE SAMPLE). - Maw References: W ~ DESIGN: 1 90 ROW ( ) 4. THE MATERIAL THAT PASSES THE #4 SIEVE IS THEN RE WEIGHED AND THE SIEVE ANALYSIS u / S ! 1. "Subdivision Plan Tall Oaks Acres 2995 & 2999 Ellington Road n RESTARTED. y> j South Windsor, Connecticut Prepared For: Stephen & Elizabeth 0 a n MINIMUM LEACHING SYSTEM SPREAD CALCULATION (MLSS) EXISTING LOT 5. THE REMAINING SAMPLES SHALL MEET THE FOLLOWING GRADATION: i \ Wisneski 2985 Ellington Road South Windsor, CT 06074 Scale: L>1 c „ HF: 30 (SLOPE=8.4% & RECEIVING SOIL DEPTH=18 ) I I 1 =50' Date: 11-17-15 Rev. 2-22-16" Class A-2 by Design ° FF: 2 / \ Professionals, Lawrence R. Geissler, Jr., L S. a PF: 1.5 Sieve Size % Passina Wet Sieve % Passing Dry Sieve 4 100 100 MLSS= HF x FF x PF = 30 x 2 x 1.5 = 90±FT (90FT PROVIDED) #10 70 - 100 70 - 100 #40 10 - 50 (SEE NOTE BELOW) 10 - 75 I U SANITARY DESIGN CRITERIA LOT 1 #100 0 - 20 0 - 5 PROPOSED RESIDENTIAL USAGE: 4-BEDROOM SINGLE FAMILY HOUSE #200 0 - 5 0 - 2 5 �' ( s ,�,i, a 1500 GPD ' W/ 100-200GAL TUB (NO GARBAGE GRINDER): � ������� NOTE: PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE DESIGN PERCOLATION RATE: < 10.1 MIN/IN PERCENT PASSING THE 100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. ' PE NT # REQUIRED EFFECTIVE LEACHING AREA = 660 SF DESIGN: 1,500-GALLON CONCRETE SEPTIC TANK WITH 2-72' ROWS THE RESPONSIBILITY FOR THE PREPARATION OF A LEACHING AREA UTILIZING "SELECT MATERIAL" IS THAT a a r 7 2 E LEACHING GALLERIES W DISTRIBUTIOIN BOX IN CENTER OF THE LICENSED INSTALLER. THE INSTALLER SHALL TAKE THE NECESSARY STEPS TO PROTECT THE (4 X1 X8 CONCRETE ) / of LEACHING AREA PROVIDED: 72' x 2 x 5.9 SF LF = 840 SF > 660 SF UNDERLYING NATURALLY OCCURRING SOILS FROM OVERCOMPACTION AND SILTATION ONCE EXPOSED. 100% RESERVE AREA PROVIDED: 2-72' ROWS (4'X1'X8' CONCRRETE LEACHING GALLERIES) cL&P 26374 A CALCULATION MLSS LOT 1 / UM LEACHING SYSTEM SPREAD MINIM HF: 28 (SLOPE=9,7% & RECEIVING SOIL DEPTH=24") I FF. 2 / I E \ PF: 1.2 (TP'-15 PERC RATE = 5.2 MIN/IN) S=1''O�L { ? ! 68±FT 72FT PROVIDED MLSS= HF x FF x PF 28 x 2 x 1.2 ( ) SEPTIC; TANK I I I I € 1 1 SANITARY DESIGN CRITERIA LOT 2 / J 5 ARRO C-3-15p0 HIV/ 3 INUR HOES PROP. WATER TAP LOCATION J / I I I t INSTA .ZABEL 1 SERIES EjNT Flt� I ( + PROPOSED RESIDENTIAL USAGE: 4-BEDROOM SINGLE FAMILY HOUSE / I D (COORD. W/CT WATER) �\ / / � ,, ON � ;PIPE� W 100-200GAL TUB NO GARBAGE GRINDER): 1500 GP / ( / DESIGN PERCOLATION RATE: < 10.1 MIN IN f .17 IN I , + /. ," L MIT OF W RANDS (T?P) { I ( /" ,� // / / 7 { I # S f REQUIRED EFFECTIVE LEACHING AREA = 660 SF 1,500-GALLON CONCRETE SEPTIC TANK WITH 1-64' ROWS ( I AN S REGU tED AREA ; (CUR-TECH CTL-24 CHAMBERS) W/ DISTRIBUTIOIN BOX AT END 64'-26h"x76"wx6'I ? I CUR-TECH CTL-24 I I I f Z LEACHING AREA PROVIDED: 64 x 13.0 SF/LF = 832 SF > 660 SF / RESERVE AREA PROVIDED: 56' ROW (CUR-TECH CTL-24 CHAMBERS) CHAMBERS 1= ! BOT. EL=346.0 299.9 Ellington IRala RESERVE LEACHING AREA PROVIDED: 56' x 13.0 SF/LF = 672 SF > 660 SF rya _ 89,848 S. 2. 6 Ac. , I D BOX 1105� C. ° Upland ! MINIMUM LEACHING SYSTEM SPREAD CALCULATION (MLSS LOT 2 �_ (IN) N/F I ,` i I Stephen J. Wisneski Jr. RESTRICTIVE LAYER DETERMINED BY TEST PIT TP-3A, MOTTLING AT 2.4 FL=347.83 (OUT) / , I p 12 ? I I CONSERVATION E SEhfENT l ( _ & Elizabeth A. Wisneski RECEIVING SOIL DEPTH= 26" (STRUCTURE HT.) + 18" (GW SEPARATION) = 44 INCHES - / , 2B -4 PVC SCH 40 , 40 FAVOR OF`TO of o0TH HF: 24 (SLOPE=5.0f% & RECEIVING SOIL DEPTH=44") / '� 1 l i IVINDSOR I S 2.62% I I (Vol 2487, Pg. 250) FF: 2 PF: 1.2 TP-15 PERC RATE = 5.2 MIN/IN) - ( PROP. UTIUTY POLE i MLSS= HF x FF x PF = 24 x 2 x 1.2 = 58FT (64FT PROVIDED) LOCATION COORD. / ` , ' LlM/T 0 CONSERVA7IN a ( / t` I FASEMEW T 3(TY:1) W/EVERSOURCE CL&P 9 , PROP. HOUSE 26373 / P1• = 4 BEDROOM' r V / O; I � FI==353. PROP. WATER TAP LOCATION u� a/ BSMT DECK _ / � FF 344.0; .S �, I ( � tg A� CONTECH C-46 NW 3" DIA. PIPE INLETS (COORD. W/CT WATER) � `3 t i G t` !r J ' I i ' � 1 i � S t � �� � � ( � N FILTER FABRIC OR EQUAL COMMON FILL I FL-349.11' r AND TOPSOIL ,r 7P 4 GARAGE 9-12"x48"x8' CONC. 'v e° a ..,A - �'' ', l A + i tiF 3 5 FF>�351.4 .� } INSTALL PER 44 CHAMBERS BOT. EL 354.0 �,� \ti �G , \ ' I MANUFACTURER'S a a.a' d ° a a . 'd a e �00 INSTRUCTION ABS PLASTIC FIN REVISIONS 48" 14" 14" BACKFILLED W/ , , 1 ` �, , APPROVED SEPTIC FILL �a CONCRETE CHAMBER � r ' � ' a 1 � + 1 BY: LF TAC CHK• JI I TYPICAL SECTION CUR - TECH CTL- 24 CHAMBER _ �� ' 349 / r� o T 2 FOR L0 N.T.S. �' ,' t / � 1 � / , ! Q0 r / 1 , J � , � i i 1 I k• I �1{ i I 9 � r s � 34'-4"IPv � � APPROVED a , SCH 40 S-2. I o� �, I ��,�a Cl) Of CL&P TOWN OF SOUTH WINDSOR Q) 26372 l;l I °�\ HEALTH DEPARTMENT DATE: I2� GARAGE I 1 I SIG: ��t - �O ass ` \ FF-349.0 � I , �o I LL I FL- I CON SER ATION.EAS' MENT IN FAVQR OF TOWN OUrH [ Q) �U346.0 PROP. HOUSE ; PROP. TREEUNE I ' W/NDSOR i 1 \` Q_ 'v L 360 } 0 4 B Roots ? RECEIVE ° w 1 Q l Lot t 1 I I i N + FF� 51.0 I 1 / D-BOX ( T ' ; !2995 Ellington h�,00'd i FL=354.45 FFw 42.0' / ; Area 62,fi 1 (� / 3ss t / i I '�' 1 212016 < I 1.44 Ac. i I 1 ILn DECK . '4 Ac UPa d < / SOUTH WINDSOR 11'-4" PVC SCH 40 ; I FL=354.45 341.5 HEALTH DEPT. Existing House Lot D-BOX ISM FL=354.62 IN 341.3 2985 Ellington Road Area = 81,835 s.f., FL=354.45 OUT i I °1 1.88 Ac. 36'-2" PVC SDR-21 A , I f i Q0 o FORCE MAIN 3 \ems EXIST SHED 0 ( v -tom °° BE EL40VED � 1 PUMP CHAMBER o i I1I FL-344.97IN CD FL-344.50 OUT a' 2'-4" PVC SCH 40 S-1.0% I �0 345 4 0 1500 GAL SEPTIC TA �� I O I i ARROW AC-3-1500 W/ 3 INLET H N , � ' I�i I � � � INSTALL ZABEL 1800 SERIES EFFLUENT FILTER ON OUTLET PIPE I , Utility Plar FL=345.32 IN FL=345.07 OUT � I1 I I 3 ! TO TH ,.BE` T OF. MY KNOWLEDGE AND BELIEF THIS DATE \ I I € MAAN�F(ALLY CORRECT AS OTED EREON. 12-19-16 -- 0 N This survey and map has been prepared in accordance with. Sections 20-300b-1 thru 20-300b-20 of the �o USS Chit SCALE o y GRAPHIC SCALE =�• t +' ` »- ' Regulations of Connecticut State Agencies - "Minimum Standards for Surveys and Maps in the State of -_:� �a r� � 1 -30 rn Connecticut" as endorsed by the Connecticut Association of Land Surveyors, Inc. It is a broperty Survey so 0 15 30 60 120 2 �W�` @ JOB NUMBER to Horizontal Class A-2 & a Topographic Surve conformi a Resurvey conforming Y n to Class T-2. r��� . u based on vg .�d.�� �O.•��' �`. + ° 2016-074 o • •�� • r� `+ Be a '�t e < / N��O SHEET N ( IN FEET ) \ a This document and copies thereof are valid only if they bear the live signature and emL-Ssed seal of �- der an declaration hereon null 1 inch = 30 ft. s ��� U the designated professional. Unauthorized alterations ren y and void. CU- } i iri