HomeMy WebLinkAbout80 West Road UAquatek Labs
3 Research Drive-Woodbridge, CT 06525
Water Analysis Report
TEST ID: A032717301
DATE SAMPLED: 3/27/2017
TO: CORNERSTONE NEWINGTON 568 SAMPLE POINT: NONE SPECIFIED
NO TREATMENT
SAMPLED BY: DENNIS SYLVESTER
PROPERTY LOCATION: 80 WEST STREET - SOUTH WINDSOR , CT
BACTERIA ABSENT PRESENT LIMITS REF METHOD
Coliform(Total) G ❑ ABSENT P SM 9223
E.Coli(Fecal) G ❑ ABSENT P SM 9223
Chlorine(Total) G ❑ ABSENT SM 4500-CI G
PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL REF METHOD
pH 7.8 SU 6.4-10 S 0 SM 4500-H B
Turbidity 1.80 NTU 5 0.10 SM 2130 B
Color ND CU 15 S 5 SM 2120 B
Odor 1 TON 2 S 0 SM 2150
CHEMICALS RESULT UNITS LIMITS MRL REF METHOD
Fluoride ND mg/L 4 P 0.3 EPA 300.0
Chloride ND mg/L 250 P 3 EPA 300.0
Nitrite Nitrogen ND mg/L 1 P 0.1 EPA 300.0
Nitrate Nitrogen ND mg/L 10 P 1 EPA 300.0
Sulfate 59 mg/L 250 S 4 EPA 300.0
Calcium 34 mg/L NONE 0.5 EPA 200.7
Magnesium 2 mg/L NONE 0.5 EPA 200.7
Hardness 94 mg/L 200 S 4 SM 2340 B
Sodium 14.8 mg/L 100 S 0.5 EPA 200.7
Copper ND mg/L 1.3 S 0.04 EPA 200.7
Iron 0.11 mg/L 0.3 S 0.04 EPA 200.7
Manganese ND mg/L 0.05 S 0.04 EPA 200.7
Arsenic 0.004 mg/L 0.010 P 0.003 EPA 200.9
Uranium(Mass) 1.70 fag/L 30 P 1.00 EPA 200.8
RADON WATER SINGLE RESULT UNITS LIMITS MRL REF METHOD
Radon Water Single 587 pCi/L 5000 S 51 SM 7500-RN
CONCLUSION: Based on the above results, this water was safe for drinking purposes at the time of collection.
P=Primary limit,used to judge potability
S=Secondary limit,recommended but not required
MRL=Minimum Reportable Level
*Limit exceeded Michael F. Berman, Ph.D.
ND=None Detected Laboratory Director
CT License#PH-0466,Aquatek Labs
R=Reference Lab Work
Reference Laboratory:ENVIRONMENTAL CONSULTING LAB
1005 BOSTON POST ROAD
MADISON,CT 06443
PH-0535
Page 1 of 1 for test#A032717301