Loading...
HomeMy WebLinkAboutDesign Recs 178 Chapel Road Town of South Windsor — Health Department 9 1540 Sullivan Avenue, South Windsor, CT 06074-2786 Phone: 860-644-2511 ext. 248 Fax: 860-644-7280 �GSbN C J� DESIGN RECOMMENDATIONS FOR REPAIR OF SEWAGE DISPOSAL SYSTEM PROPERTY OWNER(S): Anne B. Starr STREET ADDRESS: 178 Chapel Road, South Windsor RESIDENTIAL(# of Bedrooms): 2 SEPTIC TANK: Install 1,000 gallon two-compartment septic tank with approved outlet filter if current tank found to be in poor repair during inspection. PUMP CHAMBER(If necessary): A pump chamber equal to or greater than the daily design flow is to be installed. Pump chamber shall have watertight risers/manholes to grade and high level alarm. Approved force main piping to be used as detailed in CT Public Health Code—Technical Standards (Table 2d). Force mains shall be freeze protected by locating pipe below the frost line, allowing back drainage into the pump chamber through a weep hole, or other means (insulation). Licensed electrician to obtain permit from building official for operation of pump. LEACHING SYSTEM: 375 square feet of effective leaching area required. If the system is to be installed in the area of the first pit,the system must be designed with bottom of the system at two (2) inches below original grade due to mottling observed. If the system is to be installed in the area of the second and third pit,the system must be designed with bottom of the system at twelve (12) inches below original grade due to mottling observed. Original topsoil is to be removed and replaced with suitable select fill material. MLSS to be addressed. Separation distances to wetlands to be maintained. SPECIFIC INSTRUCTIONS: 1. Permit application to be completed and permit fees to be paid in full at time of application submission. 2. Installer's construction plot plan(drawn to scale)to be submitted and approved by this office prior to issuance of permit to construct. 3. Plot plan must indicate location of proposed structure, water supply, septic system, embankments, watercourses,property lines, and existing and proposed finished grades. Benchmark to be set and indicated on plan. Note on plan that existing septic system is to be properly abandoned. Wells on adjacent properties must be located and verified to meet minimum separating distances with proposed septic system(in accordance with Table 1 of Connecticut Technical Standards for Subsurface Sewage Disposal Systems). If adjacent properties are served by public water it must be noted on plan. SIGNATURE: DATE: C So 1