Loading...
HomeMy WebLinkAboutApplication 410 Burnham Street Town of South Windsor -- Health Department O 1540 Sullivan Avenue, South wlndsor, CT 06074 s Phone: 860-644-2511 ext. 250 Fax: 860-644-7280 4� B100a APPLICATION (for building conversion,change of use,building addition,accessory structure and lot line change) Standard application review time is 5.10 days.if soil testlnQ is needed,additionEwilired to co etc the review rotes. �o Street Address of Proposed Activity/Structure l �2 ff-2.010 Owner Name Mailing Address Te ephone k tau �r �_ to /�urv,� .��` -i S' 9, -20,w Applicant Name (if different than owner) Mailing Address Te etc ArX ' Describe the proposed structure or activity with dimensions: 'er- y Residential Number of existing bedrooms Non-residential _�Please describe ' Property served by on-site well? Y 60 If No,List name of water company fA4 C Property served by septic system?0 N Age of system /q� Date last pumped 7-914 Plot plan attach t scaled drawing showing property lines and dimensions, location and size of a isting and proposed structures,and site features such as driveways, wells and septic systems,drains and water courses Building plan attach a sketch/floor plan of the proposed structure, addition or renovation showing existing and prop )sed rooms with door and window locations. Sol] test data(deep test pils and percolation test) are required for the review of this application. If the data is NOT available, you will need to schedule an appointment with the health de artment`for soil testing As property owner or duly authorized representative of the property owner of the above referenced property, I agree to allow the health department staff to enter the above referenced property as part of this B 100a application review process.I further agree that this authorization to enter the subject pro ay extend through a period of time ending with the final B 100a application a royal and affirm such wish a re bgfow. Applicant Signature: Date: �,i-1 "I ke FOR OFFICE USE ONLY: Approved: (y) N By: Q(L'IW / oa11 1 Date: kk\MWO Com ments/Condit ions: NOV 0 ' 2016 May 2011 SOUTH WINDSOR HEALTH DEPT. E abed 990b68E098 luawdlnb3 '8 lool alge/ Wd60:06 960E LO ^cN PUDELER ENGINEERING, PX Civil Engineering is Land Surveying 201 West Road, South Windsor,CT 06074 Phone: (860)610-0001 Fax: (860)282-7726 October 11, 2016 Town of South Windsor Health Department Heather Oatis, Environmental Health Officer 1540 Sullivan Avenue South Windsor, CT 06074 Re: 430 Burnham Street South Windsor, CT Dear Heather: Able Equipment is proposing a 60' x 40' addition to their building. The addition will house an equipment wash rack and some dry inside storage. The wash bay is a self contained 100%recycled unit that will have no discharge. The unit will be c caned, serviced and maintained quarterly by a service provideder. The present building is on septic and no change in employees or offs space is planned. According to Table 4 of the Septic Design Manual, design flows am, office 200 sq. ft/person x 20 gpd/per person and Industrial building 0.1-gallon/per day R ross area. The existing building is: 364 sq. ft. office—200 x 20 = 40 (10800-368) Sq. ft. x 0.1 = 10410 Total ;084 gl)d The new addition: 60' x 40' x 0.1 = 240 gpd Increase approximately 24% The proposed additional washroom and storage do not increase the building sewage design flow more than 25% E a5ed 990V68ZO98 juawdinb3 g tool atq`d Wb60:06 960Z LO ^oN Nov 07 2016 10:11 AM Able Tool & Equipment 8602894066 page 1 The Public Health Code, Building Conversions, Changes in Use, Additions, effective August 3, 1998, 19-13-B 100A (c) (5) allows up to 50% increase. We are at half this level and no changes in the septic are proposed. Please call if you have any questions. Very truly yours, Kenneth J. Pudeler CT P.E. L.S. #9653 i 149 Rocus St. SpNn9lie/d, MA 01104 413-363-0780 Iz 4f0 Burnham Street South Windsor, CT 06074 860-289-2020 Office 860-289-4066 Fax FAX # Pages incl. / cover 4 Contact: Heather Oatis From: Derek Bauer Company Env. Health Officer RE: Health De t. B100A lication Phone: Date: 1117/16 Fax: 860-644-7260 Hi Heather, Thanks for the email regarding our addition at 410 Burnham. See Application to follow. I will drop off the set of plans at planning dept. - I will be there in next coupl days. Call with any questions. Thanks, Derek Please call with any questions. Thank you, Able Tool & Equipment www abletool.net South Windsor, CT 860-289-2020 Off. 6 a6ed 990t,68Z098 juawdmb3 '8 lool atgb' Wd60:06 Me LO ^oN