HomeMy WebLinkAbout955 Strong Road ENVIROTECH LABORATORY, LLC
77 cooR HrLL ROAD -WINDSOR, CONNECTICUT 06095
MART ELLEN DiLUZIO TBLEPMONE
(860) 688-7249
October 10,2016
Mark Donahue
400 Chapel Rd.Unit 3-F
i South Windsor,Ct.06074
i
Dear Sir:
We have the following to report on the sample submitted to this Laboratory on October 7,2016.
Sample Number: 2677
Mark: water sample collected 10/7/16 by Mark Donahue from
Lot No.955,Strong Rd.,South Windsor,CT.
CURRENT MAXIMUM CONTAMINATION
TEST PARAMETERS TEST RESULTS LEVELS
(in mg/L) (MCL)
ODOR NONE No MCL,Recommended:None
TURBIDITY 2 No MCL,Recommended:<5 ntu
COLOR 5. No MCL,Recommended:<50
PH 7.48 Ideal 6.4—10.0
NITRITE NITROGEN < 0.001 MCL is 1.0 mg/L
NITRATE NITROGEN < 1.00 MCL is 10.0 mg/L
CHLORIDE 318 No MCL,Recommended:<250 mg/L
HARDNESS 308 No MCL, > 100 mg/L is hard
IRON 0.13 No MCL,staining>0.30 mg/L
MANGANESE 0.08 No MCL,Action Level>0.50 m
SODIUM 144.4 No MCL,
SULFATE 188.5 No MCL,>256 mg/I.is high
T.COLIFORM BACTERIA ABSENT Must be Absent
Per 100 mLs,membrane filter
E.COLI BACTERIA ABSENT Must be Absent
Per 100 mLs,membrane filter
All parameters analyzed are below the Maximum Contamination Levels (MCL's)for potable water and meet the
drinking water standards established by the Conn.State Health Department. The water is considered extremely hard
since it contains a hardness well over 100 mg/L. The manganese content is above the 0.05 mg/L staining level. The
sodium content is above the recommended 28 mg/L limit established for people on low salt diets. If there are any
questions we would be pleased to discuss them with you.
Very truly yours,
EnviroTech Laboratory,LLC
�r
REcEiVE® C
Maryellen DiLuzio,a member
i OCT PH0464
SO R HEALTH`DEPT.
CPR-9 Rev.7/95 DO NOT fill In
STATE OF CONNECTICUT STATE WELL NO.
DEPARTMENT OF CONSUMER PROTECTION
REAL ESTATE&PROFESSIONAL TRADES DIVISION OTHER NO.
WELL DRILLING COMPLETION REPORT
165 Capitol Avenue,Hartford,Connecticut 06106
LOCATION (No.&Street) (Town) (Lot Number)
OF WELL
OWNER NAME ADDRESS
❑ DOMESTIC BUSINESS a ESTABLISHMENT FARM WELL
TEST
PROPOSED
USE OF WELL PUBLIC SUPPLY INDUSTRIAL AIR CONDITIONING OTHER
CABLE
EQUIPMENT El ROTARY ❑ ARMERCUSSION PERCUSSION OTHER ION
CASING LENGTH(feet) DIAMETER(inches) WEIGHT PER FOOT DRIVE SHOE WAS CASING GROUTED?
DETAILS _ THREADED❑ WELDED ❑ YES ❑ NO 0 YES ❑ NO
YIELD TEST ❑BAILED ❑ PUMPED ❑ COMPRESSEDAiR HOURS YIELD(GPM)
WATER MEASURE FROM LAND SURFACE-STATIC(Specify feet) DURING YIELD TEST(feet) Depth of Completed Well in feet
LEVEL
MAKE LENGTH OPEN TO AQUIFER(feet)
SCREEN
DETAILS SLOT SIZE DIAMETER(Inches) IF GRAVEL Iemeter o we GRAVEL SIZE(inches) (feet) (feet)
PACKED: including gravel pack
(inches)
DEPTH FROM LAND TO SURFACE FORMATION DESCRIPTION Sketch exact location of well with distances,to at least two
FEET TO FEET permanent landmarks
F ,r .
If yield was tested at different depths during drilling,list below
FEET GALLONS PER MINUTE
SOUTH WINDSOR
HEALTH DEPT.
DATE WELL COMPLETED —F-7—PERMIT NO. REGISTRATION NO. DATE OF REPORT LL WELL DRILLER(Signature
LOCAL DIRECTOR OF HEALTH