Loading...
HomeMy WebLinkAbout955 Strong Road ENVIROTECH LABORATORY, LLC 77 cooR HrLL ROAD -WINDSOR, CONNECTICUT 06095 MART ELLEN DiLUZIO TBLEPMONE (860) 688-7249 October 10,2016 Mark Donahue 400 Chapel Rd.Unit 3-F i South Windsor,Ct.06074 i Dear Sir: We have the following to report on the sample submitted to this Laboratory on October 7,2016. Sample Number: 2677 Mark: water sample collected 10/7/16 by Mark Donahue from Lot No.955,Strong Rd.,South Windsor,CT. CURRENT MAXIMUM CONTAMINATION TEST PARAMETERS TEST RESULTS LEVELS (in mg/L) (MCL) ODOR NONE No MCL,Recommended:None TURBIDITY 2 No MCL,Recommended:<5 ntu COLOR 5. No MCL,Recommended:<50 PH 7.48 Ideal 6.4—10.0 NITRITE NITROGEN < 0.001 MCL is 1.0 mg/L NITRATE NITROGEN < 1.00 MCL is 10.0 mg/L CHLORIDE 318 No MCL,Recommended:<250 mg/L HARDNESS 308 No MCL, > 100 mg/L is hard IRON 0.13 No MCL,staining>0.30 mg/L MANGANESE 0.08 No MCL,Action Level>0.50 m SODIUM 144.4 No MCL, SULFATE 188.5 No MCL,>256 mg/I.is high T.COLIFORM BACTERIA ABSENT Must be Absent Per 100 mLs,membrane filter E.COLI BACTERIA ABSENT Must be Absent Per 100 mLs,membrane filter All parameters analyzed are below the Maximum Contamination Levels (MCL's)for potable water and meet the drinking water standards established by the Conn.State Health Department. The water is considered extremely hard since it contains a hardness well over 100 mg/L. The manganese content is above the 0.05 mg/L staining level. The sodium content is above the recommended 28 mg/L limit established for people on low salt diets. If there are any questions we would be pleased to discuss them with you. Very truly yours, EnviroTech Laboratory,LLC �r REcEiVE® C Maryellen DiLuzio,a member i OCT PH0464 SO R HEALTH`DEPT. CPR-9 Rev.7/95 DO NOT fill In STATE OF CONNECTICUT STATE WELL NO. DEPARTMENT OF CONSUMER PROTECTION REAL ESTATE&PROFESSIONAL TRADES DIVISION OTHER NO. WELL DRILLING COMPLETION REPORT 165 Capitol Avenue,Hartford,Connecticut 06106 LOCATION (No.&Street) (Town) (Lot Number) OF WELL OWNER NAME ADDRESS ❑ DOMESTIC BUSINESS a ESTABLISHMENT FARM WELL TEST PROPOSED USE OF WELL PUBLIC SUPPLY INDUSTRIAL AIR CONDITIONING OTHER CABLE EQUIPMENT El ROTARY ❑ ARMERCUSSION PERCUSSION OTHER ION CASING LENGTH(feet) DIAMETER(inches) WEIGHT PER FOOT DRIVE SHOE WAS CASING GROUTED? DETAILS _ THREADED❑ WELDED ❑ YES ❑ NO 0 YES ❑ NO YIELD TEST ❑BAILED ❑ PUMPED ❑ COMPRESSEDAiR HOURS YIELD(GPM) WATER MEASURE FROM LAND SURFACE-STATIC(Specify feet) DURING YIELD TEST(feet) Depth of Completed Well in feet LEVEL MAKE LENGTH OPEN TO AQUIFER(feet) SCREEN DETAILS SLOT SIZE DIAMETER(Inches) IF GRAVEL Iemeter o we GRAVEL SIZE(inches) (feet) (feet) PACKED: including gravel pack (inches) DEPTH FROM LAND TO SURFACE FORMATION DESCRIPTION Sketch exact location of well with distances,to at least two FEET TO FEET permanent landmarks F ,r . If yield was tested at different depths during drilling,list below FEET GALLONS PER MINUTE SOUTH WINDSOR HEALTH DEPT. DATE WELL COMPLETED —F-7—PERMIT NO. REGISTRATION NO. DATE OF REPORT LL WELL DRILLER(Signature LOCAL DIRECTOR OF HEALTH