Loading...
HomeMy WebLinkAboutFloorplans 935 Sullivan Avenue _ o o 0 0 0 0 rn D o o � o o F_ 0- - - 0 0 . o I I I I 9 0 00 00 00 0 I i I i 0 I0 o 00 (7) 0 I 0 I 0 0 0 CA � I • -0 D c y ti 0V I 0 N -I . � _ P::: N 0 E-J:::: [i, 0 V � o 0 �� v 0 Io .O cra v - . .--..._.-.....--.r-----....-.,.......... 00 oo ATER I 3m 0 0 0 o I I 0 I I I oN I 0 i � o _ 000 _ o i I jjj 0 o (D 00 0 WATE .._..._.._........-_.. ---- I 0 0 0 00 0 I 0 0 0 O I I I 0 0 0 c o { CD m D CIO # I I f ~ 0 0 0 ( I 0 0 0 0 00 0 I I1 r INC0 0 00 -.AT-_E ._------.-.- 0 Wr I ( w I I N I ( w N O O ( o p 1 - WATE m —.._._. .--_-_._-_--.-_.._--.... I :�:D z - I ' z w L__j I N H W OD w I � 48(4)24 1111111148(024111 48 c+�24 36(+)24 I I o I Q 0 � � o 0 . 2 4 ' INJill� 4 8 4 8 — Cn © (V rn t P P P 4� Ca ? CO c o CO N j N IV N N N N try O C7D {a {a 4, P 1 I I �,(f) O _ C7D I 48(+)24 48(+)24 48(+)24 48 +)24 48(,)24 L � I I RD FT� > cj� � cj� o ICI r vJ CU m MEXICALI FRESH,,.MEX GRILL PROJECT # 1365 Drawn by Revisions o �,� _ CROMUUELL CONSULTING, INC. THIS DOCUMENT INCLUDING THE Checked by _ 27 Glen Street, Suite 5, Stoughton, MA. 02072 IDEAS AND DESIGNS INCORPORATED • WINDSOR, CT - Phone (781)344-7691 Fax(781)344-7694 HEREIN ARE THE PROPERTY OF t FOOD SERVICE EQUIPMENT SCHEDULE aslosizo�3 cROMwELL CONSULTING, INC. AND SHALL NOT BE USED IN WHOLE Date Printed OR PART WITHOUT WRITTEN NOTICE LAYOUT 0412412014 FROM CROMWELL CONSULTING, INC. 1 2 3 4 5 6 7 8 i 0 Wv L-i r U z f— Z W Q Cl:'- 10 O . OZCD a- U = Z c.� � � zz � Z0 � — w � � zw n cn — Oz ryz z cn LL J _ z � cnl A � , cn ~ tn = Z 0 -► zwl- ow = w Li SCHEDULE OF EQUIPMENT Llja � 0 UzQJ � � © � zzQ � . ITEM QT. DESCRIPTION ELECTRICAL WATER WASTE GAS EXHAUST MAKE-UP MANUFACTURER MODEL REMARKS V) Q iz 0 Q O i # - s F- <s p W tz w I— L = U cnOt_U) w ¢ Q w L w z n w w __j, a- O O Lt- O O � � cn L, w O CL w O a > c) I - ¢ Y) 0 U) 1 1 WALK-IN REFRIGERATOR 20,0 - - 120 1 JB DFA - - - - - - - - - - - - - - - - - - 2 1 REFRIGERATOR EVAPORATOR - - - JB DFA - - - - - 3/4" FS - - - - - - - - - - 3 1 REFRIGERATOR CONDENSER - - - - JB „ 4 1 REFRIGERATOR EVAPORATOR - - - - JB - DFA - - 3 4° FS - - - - - - - - - - - 5 1 REFRIGERATOR CONDENSER 15.0 - - 120 1 JB - - - - - - - - - - - - - - - - - - - - - 6 1 FREEZER EVAPORATOR - - - - JB - DFA - - - - 3 4° FS - - _ _ _ _ _ _ _ _ ELECTRICIAN TO WRAP DRAIN WITH HEAT TAPE 7 1 FREEZER CONDENSER - - - - JB - - - - - - - - - - - - - - - - - - - - - 8 1 BEER COOLER EVAPORATOR - - - - JB - DFA - - - - - 3 4" FS - - - - - - - - - - - - - 9 1 IBEER COOLER CONDENSER 10 10 SHELVING UNIT - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - METRO 24" X 48" - ;' i 11 2 SHELVING UNIT METRO 18" X 30" - 12 2 SHELVING UNIT - - - - - - - - - - - - - - - - - - - - METRO 18" X 48" - I i3 2 IS UNIT - --. _ _ _ _ _ _ _ ? __ _ _ _ - _ _ - METRO 18" X 48" 14 10 SHELVING UNIT - - - - - - - - - - - - - - - - - METRO 24" X 48" 15 2 SHELVING UNIT METRO 24" X 36" i 16 1 THREE COMPARTMENT SINK - - - - - - - - 3 2" IIADVANCE TABCO 94-3-54-18R INCLUDE TWIST LEVER WASTE w SUPPORT BRACKETS 17 1 FAUCET - - - - - 1/2" 1/2" 16" - - _ _ _ _ _ _ _ _ - - T&S BRASS B-0230-CC 18 1 UTENSIL SHELF - - - - - - - - - - - - - - - ADVANCE TABCO PS-15-60 ~ 1 19 1 SOILED DISH TABLE - - - - ~ - - _ - 1-1/2° FS - - - - - - - - FABRICATED CUSTOM FABRICATION INCLUDE DOUBLE SIDED SORTING SHELF 20 1 PRE-RINSE FAUCET - - - - - 1/2" 1/2" T&S BRASS B-0133-BC -- I • 21 1 CLEAN DISH TABLE - - - - - - - - - - - - - - - - - - - - - - ADVANCE TABCO DTC-S30-6OR I I 22 1 DISH MACHINE - - - 208 3 DC - - - 1/2" 72" - - 2 -FS - - - - - - - - VENDOR PROVIDED NOT IN FOODSERVICE CONTRACT VERIFY ALL UTILITY REQUIREMENTS WITH OWNER'S VENDOR 23 1 CONDENSATE HOOD - - - - - - - - - - - - - - - - - - 600 10" X 10" 0.075 - - - EAST COAST FIRE AND VENTILATION - FAKS AND CONTROLS BY OTHERS U ti 24 1 WORK TABLE - - - - - - - - - - - - - - - - - _ - - - - - ADVANCE TABCO KSS-306 - Z CCNI rn 25 2 WALL SHELF - - - - - _ - - - - - ADVANCE TABCO WS-12-72 - 26 1 PREP SINK - 1-1 2 FS ADVANCE TABCO 94--21-20-18R INCLUDE TWIST LEVER WASTE < 27 1 IFAUCET - - - - - 1/2" 1/2"1 16° - - - - - - - - - - - - - T&S BRASS B-0231--CC - 28 2 HAND SINK - - - - 1 2" 1 2" 24" 1-1 2° 18" - - - - - - - - - - - - ADVANCE TABCO 7- PS-66 SOAP AND TOWEL DISPENSER BY OWNER J o co 29 1 PLATE CABINET - - - - - - - - - - _ - - - _ _ _ _ _ _ _ _ - ADVANCE TABCO DC-1512 - I x 30 1 MICROWAVE OVEN 13.4 1.0 - 12O 1 S - 62" - - - - - - - - - - - - - - - - PANASONIC NE-1064F - ! U7 a LL 31 1 WALL SHELF ADVANCE TABCO WS-15-24 - Z 32 1 PASS THRU SHELF - - - - - - - - - - - - - - - - - - - - - - - - FABRICATED CUSTOM FABRICATION - Qo 33 1 TWO SIDED GRIDDLE 15.0 1.8 - 120 1 SR - 48" - - - - - - - - - - - - - - STAR GR10E 34 1 WORK TABLE - - - - _ _ _ _ _ _ _ _ _ _ _ w _ _ _ - - ADVANCE TABCO KSS-244 - J 35 1 HEATED CABINET 15.0 11.75 120 i SR - 14" - - - - - _ _ _ _ _ _ _ _ - - CARTER HOFFMAN HL3-18 - i W a) a) co 36 1 HOT WELL UNIT 24.0 5.0 - 208 1 JB - 24" - 1 2" 18" - f 2° FS - - - - - - - - DELFIELD F14EI460 - ~ 37 1 REFRIGERATED SANDWICH UNIT 10.3 - 1 2 115 i SR 14" - _ - - - - - - - - - - - - - - TRUE TSSU-72-18 - c 38 1 WORK TOP REFRIGERATOR 5.0 - 1 5 115 1 SR - 14" - - - - - - - - - - - - - - - TRUE TWT-48 - 10 CD 39 1 REACH-IN REFRIGERATOR 7.6 - 1/3 115 1 SR - 14" - - - - - - - - - - - - - - - - - TRUE T-23 40 1 EXHAUST HOOD 5.0 - - 120 1 JB - DFA - - - _ - _ - - - - - EAST COAST FIRE AND VENTILATION - FANS AND CONTROLS BY OTHERS U x.' 41 1 FIRE SUPPRESSION SYSTEM 5.0 - - 120 1 JB - DFA - - - - - - - - - - - - - - - - - ANSUL R102 - C 42 1 DOUBLE CONVECTION OVEN 2 6A - (2)1/3 2 120 1 SR - s2 14 - - - - - - 3/4'n 100 NAT 12„ - - - - - - BLODGETT ZEPH-100-G DOUBL INCLUDE GAS MANIFOLD FOR DOUBLE OVENS = 43 1 COUNTERTOP RANGE - - - - - - - - - - - - - - 3 4 198 NAT 30 - - - - - - SOUTHSEND HDO-36 - ` 44 1 GRIDDLE - - - - - - - - - - - - 3 4" 120 NAT 30" - - - - - - SOUTHBEND HDG-48 - 45 1 CHAR BROILER _ - - - - - - - - - - - 3 4" 160 NAT 30" - - - - SOUTHBEND HDC-48 - I 46 1 REFRIGERATED STAND 5.7 - 1 5 115 1 SR - 14" - - - - - - - - - - - TRUE TRCB-36 47 1 REFRIGERATED STAND 10.4 -- 1 3 115 1 SR - 14" - - - - - - - - - - - - - - TRUE TRCB-96 48 1 FRYER 0.7 - - 115 1 SR - 14" - - - - - 3 4" 105 NAT 12" - - - - - - PITCO SSH75-•-SSTC--S - I 49 1 STOCK POT STOVE - - - - _ _ _ _ _ _ _ _ 3 4" 120 NAT 12" - - - - - - SOUTHBEND SPR-1 J - 50 OT STAINLESS STEEL WALL PANEL - - - - - - - - - - - - - - - - - - - - FABRICATED CUSTOM FABRICATION _ 51 6 3 4" GAS DISCONNECT HOSE - - - - - - - - - - - - - _ _ - - - - - - _ T&S BRASS HG-4D-36K - fcn 52 - SPARE NUMBER - - - - - - -" - " - - - - -" 53 1 ICE MACHINE 15.0 - - 120 1 DC - 78 3 8 - - - - 1/2" FS - - - - - MANITOWOC ID-1202A f' 54 1 ICE BIN_ - - - - - - - 3 4" F3 - - - - - - - - - - MANITOWOC B-570 - 55 1 WATER FILTER - - - - - - 3 8" - 66" - - - - - - - - - - - 3M CUNO ICE140-S INCLUDE REPLACEMENT FILTER 56 1 FLOOR TROUGH - - - - - - - - - 4" -4" - - - - - - - - - - ADVANCE TABCO FFTG-1236 - M 57 2 MOP SINK - - - - - - - - - 1-1/2* 18" _ _ _ - - _ _ _ _ - ADVANCE TABCO 4-OP-18 - 4 58 2 SERVICE FAUCET - - - - 1/2" 1/2 24" - - - _ - - - - - - T&S BRASS B-0665-BSTR - 59 1 SHELVING UNIT - - - - - - - - - - - - - - - - - - - - - METRO 18" X 24" 60 1 ICE CREAM DIPPING CABINET 5.7 1 4 115 1 SR - 14" - - - - - - - - - - - - - - - - - TRUE THDC-2SF v tno o Q�cli 61 - SPARE NUMBER �o �� 62 - SPARE NUMBER - - - - - - - - - - - - - - - - - - - - - - I ca °' C) `C' 63 1 BAG-IN-BOX SODA SYSTEM 10.O - - 120 1 DR - 48" 1/2" - 48" - - - - - - - - - - - - - - VENDOR SUPPLIED NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY ALL UTILITY REQUIREMENTS WITH OWNER'S VENDOR �� �� ' 64 1 BEER CHILLER SYSTEM - - 120 1 - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - BY OWNER - VERIFY UTLITY REQUIREMENTS WITH OWNER 65 2 REACH-IN REFRIGERATOR 7.9 - 1/3 115 1 SR 14" - - - - - _ _ _ _ _ _ _ _ _ _ _ TRUE T-23G-2 - 66 i CHIP WARMER 12.8 - - 120 1 SR 48" - - - - - - - - - - CARTER HOFFMANN CW4 INCLUDE MOBILE STAND 67 1 TABLE - - - - ~ - - - - - - - - - - _ - ADVANCE TABCO KSS-305 - D 68 1 DROP-IN SINK _ _ T _ - 1/2" 1/2" 24" - 1-1 2" FS - - - - - - - - _ ADVANCE TABCO DI-1-10 _ c� 69 1 DROP-IN HAND SINK 1/2" 1 2" 24" f-1 2` 18" ADVANCE TABCO DI-1-10SP r 70 1 ICE TEA BREWER - - 124 1 SR - 48" 1 4" - 48" - - - - - - - - - - - - - - VENDOR SUPPLIED NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY ALL UTILITY REQUIREMENTS WITH OWNER'S VENDOR I 71 1 SODA ICE DISPENSER 10.0 - - 120 1 SR - 48" - - - - - 1" FS. - - - - - - - - - - VENDOR SUPPLIED NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY ALL UTILITY REQUIREMENTS WITH OWNER'S VENDOR 72 5 POS SYSTEM 15.0 - - 120 1 DR - 48" - - - - - - - - - - - - - - - - BY OWNER NOT IN FOODSERMCE EQUIPMENT CONTRACT REQUIRES DEDICATED POWER SOURCE WIHT ISOLATED GROUND TO BREAKER & CONDUIT FOR DATA AND COMMUNICATION LINES (, 73 1 TABLE - - - - - - - - - - - - - - - - - - - - - - - - ADVANCE TABCO KSS-306 - W 74 - SPARE: NUMBER - - - - - - - - - - - - - - - - - - - - - - - - '� s,'.. 75 1 THREE COMPARTMENT SINK - - - 3 8" 3 8" 14" - - 1-1 2° FS - - - - - - - - - GLASTENDER TSA-36-S - I 76 3 GLASS RACK STORAGE GLASTENDER DBGR-24 - 77 3 BLENDER STATION 15.0 - 120 1 DR 12" 3 8" 3 8" 14" - 1-f 2" FS - - - - - - - - GLASTENDER BSA-12 - 78 3 ICE BIN _ - _ - - - - f" FS - - - - - - GLASTENDER IBA-30-CP10 INCLUDE SINGLE 30" SPEED RAIL 79 3 BOTTLE DISPLAY GLASTENDER LDA-18S - 80 2 HAND SINK - - - - - - 3 8" 3 8" f4" f-f 2" 12" - - - _ - GLASTENDER HSA-12-D - 81 1 GLASS FROSTER 2,6 - 1 5 115 1 SR - 12" - - - - - - - - - - - - - - - - - TRUE T-24-GC 82 1 GLASS FROSTER 4.0 - 1/3 115 1 SR - 12" - - - - - - - - _ _ _ _ _ _ _ _ TRUE T-36-GC - 83 1 BOTTLE COOLER 8.6 - 1/3 115 1 SR - 12° - - - - - - _ _ _ - _ _ - - TRUE: TD-65-24 - 84 1 UNDERCOUNTER REFRIGERATOR 3,9 - 1 6 115 1 SR - 12" - - - - - - - - - - - - - - - - TRUE TUC-27 s 85 1 GLASS WASHER 30.5 - - 208 1 DC - 12" - 3 4° 14" - - 1° FS - - - - - - - - - - VENDOR SUPPLIED NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY ALL UTILITY REQUIREMENTS WITH OWNER'S VENDOR 86 1 PASS-THRU REFRIGERATOR 8.2 - - 120 1 SR 4" - - - - - - - - - - - - - - - - - GLASTENDER PT84 INCLUDE GLASS DOORS, VERIFY FINISH WITH OWNER OPERATOR i ,I t J A B B R E V I A T I O N S K E Y N O T E S o ELECTRICAL PLUMBING GENERAL APPLICATION V VOLTAGE HW HOT WATER AFF ABOVE FINISHED FLOOR ui PH PHASE CW COLD WATER BFF BELOW FINISHED FLOOR MECHANICAL AND ELECTRICAL CONTRACTOR MUST CHECK OWNER'S PRESENT EQUIPMENT BEING RE-USED, _ AMP AMPERAGE DW DIRECT WASTE BTC BRANCH TO CONNECTION EQUIPMENT SUBSITUTED FOR SPECIFIED TYPE OR MANUFACTURER OR THAT EQUIPMENT MARKED (BY VENDOR) V KW KILOWATT IW INDIRECT WASTE DFA DROP FROM ABOVE WHICH IS BEING SUPPLIED BY OTHERS SO THAT THE SERVICE REQUIREMENTS ARE CORRECTLY TYPED, HP HORSEPOWER G GAS CENTERLINE ADEQUATELY SIZED, & ROUGHED IN PROPERLY (LOCATION, HEIGHT & CONNECTION TYPE) SO AS TO SR SIMPLEX RECEPTACLE BTU BRITISH THERMAL UNIT NIC NOT IN CONTRACT MINIMIZE THE AMOUNT OF MATERIALS & FITTINGS NEEDED FOR FINAL HOOK-UP RESULTING IN A NEAT AND Z DR DUPLEX RECPTACLE S STEAM INLET ORDERLY LOOKING JOB. LLI JB JUNCTION BOX SR STEAM RETURN PROJECT PERSONNEL ALL LABOR, SWITCHES, DISCONNECTS & FITTINGS REQUIRED FOR FINAL CONNECTION OF EQUIPMENT AS CP CORD & PLUG FS FLOOR SINK ARCH ARCHITECT NECESSARY TO COMPLY WITH ALL CODES, INCLUDING ALL INTERWIRING TO BE FURNISHED BY ELECTRICAL i_ DC DIRECT CONNECTION FD FLOOR DRAIN ID INTERIOR DESIGNER CONTRACTOR UNLESS STATED OTHERWISE. Al CHANYCAL FFD FUNNEL FLOOR DRAIN MEP MECHANICAL ENGINEERING FIRM ALL 'LABOR, VALVES, TRAPS, TAILPIECES, STRAINERS, PRESSURE REDUCING VALVES, & FITTINGS REQUIRED 0 { CFM CUBIC FEET PER MINUTE WF WATER FILTER FSC FOODSERVICE CONSULTANT FOR FINAL CONNECTION OF EQUIPMENT AS NECESSARY TO COMPLY WITH ALL CODES, INCLUDING ALL INTER- W y' SP STATIC PRSSURE KEC KITCHEN EQUIPMENT CONTRACTOR CONNECTIONS TO BE FURNISHED BY MECHANICAL CONTRACTOR UNLESS OTHERWISE STATED. W FSS FIRE SUPPRESSION SYSTEM MW MILLWORK CONTRACTOR U MECHANICAL CONTRACTOR TO PROVIDE REMOVABLE 12" SECTION OF PIPE IN MAIN GAS SUPPLY LINE IN AN U > ACCESSIBLE AREA FOR INSTALLATION OF EITHER MECH. OR ELEC. CONTROLLED GAS SHUTOFF-VALVE, F-- W T R A D S K Y FURNISHED AS PART OF THE FIRE PROTECTION SYSTEM AND INSTALLED BY THE PLUMBING CONTRACTOR. F� U Lu J GC EC PCco HVAC KECj F' GENERAL ELECTRICAL PLUMBING HEATING,VENTILATION KITCHEN W CONTRACTOR CONTRACTOR CONTRACTOR & AIR-CONDITIONING EQUIPMENT 0 _ CONTRACTOR CONTRACTOR O 1 U �y i FS -2 f SCALE - NONE