Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Floorplans 855 Sullivan Avenue
(OWNER WOULD LIKE TO REPLACE TWO COUNTERTOP COOLATTA MACHINES WITH 342) ' _----_ U ® -- - 30 BASKETS 24 BASKETS a (� (�® a ELECTRIC PANELS 7 0 430 12 BASKETS I J= i 340 1 ❑ DONUTS BAKERY p ICE ® ® � ® ® LEGEND: CD w p I 1 P11 ® I _ 1 BAGELS EXISTING STUD WALL, C�j J Hand SANDWICH STATION I-1 - 6'-0" COOLATTA 6'-0" COFFEE L.._._...J 2x4 R 2x6 STUD C� W/ DELFIELD UCR Sink 13'-2 3/4" WALL ® 16" O.C. ® E)% U PREP. AREA ® � � ' SERVING AREA • �� 2x4 OR 2x6 STUD �ii ii� ii i NEW STUD WALL, 7'-0" SPECIALTY ICED WALL ® 16 O.C. (I o ICE CADDY UNDER OFFEE 2'-8" 2'-8" 1'-0" 2'-8" I.C. DISPENSERS REWER 5'-0" COFFEE CASH 5'-0" COFFEE CASH FILLER CASH 5'-0" COFFEE a o C ® ®® � S ® ° e C �° " PEPSI PEPSIOFFICE° �AT� 0 C°oL£R c°°LER GENERAL NOTESL _ ® ® a�� ® ® ® ® G45M- G45M- - �la --- ----- - ----� y I d o w� 1. GENERAL CONTRACTOR SHALL REFER TO WRITTEN SPECIFICATIONS FOR �77 = i� m¢�¢o ADDITIONAL INFORMATION NOT CONTAINED IN THE DRAWINGS. DISPLAY J 2. GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING AT SHELVING, 3 € ' 4'_0" o cwa COMPARTMENT SINK, T & S SPRAY BRACKET, POT RACK, HAND SINKS, MOP " CLEAR SINK, FAUCETS, TIME CLOCK, GRAB BARS, LAVATORIES, HAND DRYERS, MIRRORS, PAPER TOWEL DISPENSERS, SOAP DISPENSERS, OTHER ACCESSORIES, ETC. 3. REFER TO THE 'K' DRAWING(S) FOR INFORMATION REGARDING THE EQUIPMENT AND EQUIPMENT LAYOUT. T 2 2 0 4. GENERAL CONTRACTOR SHALL INSTALL 2"x8" BLOCKING FOR SANDWICH STATION, rr■` 1 ELECTRIC TOP OF BLOCKING ® 4'-4" A.F.F. ALSO BLOCKING FOR VDU MONITORS. rrrrlrlrrIr 4 :�4 �in 5. ALL TOILET WALLS AND OFFICE WALLS TO HAVE ALUMINUM FACED FIBERGLASS LLI SALES AREA m X ROOM INSULATION. ,..., Q z {ZD SEATS) FY r¢-0 6. SEE SITE PAN PROVIDED BY OWNER FOR NUMBER AND LOCATION OF THE a, O 1- € ! I FOLLOWING SITE FURNISHINGS (ALL BY WAUSAU TILE): TABLE WITH SEATING Q - 2'-8" iv -----� EXTER€Oft 3SEATING TABLE WITH SEATING3139D3, TRASH CAN NEXT TO n #TF1020A5, TRASH CAN WITH CHUTE NEXT TO Z Q �► O N� 1 DRIVE-THRU AREA #TF1021A5, GROUNDSKEEPER SMOKING MANAGEMENT cn Fmz € +�1 12"� U T L RECEPTACLE, COLOR: BEIGE, #2570-88. (OPTIONAL) " cn m to �1 H.W. �N€S 7• PROVIDE FIRE EXTINGUISHERS, TYPE ABC, WALL HUNG, TOP ® 5 0 A.F.F. (BY V i L-----J HTR. 1 d01N 01 G.C.). - NUMBER AND LOCATION AS DETERMINED BY LOCAL CODE. © _'-IJ CO m 8. IF A LARGER OFFICE IS REQUIRED, EXPAND TOWARD BOH, NOT FOH. Q 2 m to t PL M 9• BEVERAGE REFRIGERATOR TO BE 54 HIGH WHEN NOT PLACED AGAINST WALL ' " " 12" -• y 10.HANDICAP REQUIREMENTS: O j X p THE GENERAL CONTRACTOR WILL ACQUAINT HIMSELF WITH THE HANDICAPti- TOI T F�F) € ��,--;;� c9 STORAGE REQUIREMENTS OF THE APPLICABLE STATE AND THE AMERICAN DISABILITIES ACT _ Q I f L-_- �� 1 ��� �� (ADA) AND INSURE THAT THIS FACILITY WILL BE ACCESSIBLE. THE FOLLOWING IS pQ Z #ir € 1 A PARTIAL LIST OF REQUIREMENTS: uj 3: COOLER 1. AISLES MINIMUM 36" WIDE. § a t •1 I ; TOIL �€ FREEZER2. CURB CUTS V STI B U LE € I -- #2 € • 6 X 6 3. MAX. SLOPE OF05%EORA1: HANDICAP PARKING N'ALL PARKING LOTS AND ON SIDEWALKS, ALL g `� � € / � V 6 X 6 � � 1 c __jLj Li Li �� �� € i 1` / OTHER AREAS NTH GREATER SLOPE WILL BE CONSIDERED A RAMP. Ld 7'-2" 4• SIDEWALKS WILL BE A MINIMUM OF 4'-0" WIDE, WITH A 5'x5' PAD IN FRONT I€ € ��` �� 2 2 REF OF EXTERIOR OUTSWINGING DOORS PER CODE. - 4 4 5• RAMPS HAVE TO HAVE A MAXIMUM SLOPE OF 1:12 WITH HANDRAILS AT 34" „ AND 19" ABOVE THE FLOOR ON BOTH SIDES AND TO EXTEND BEYOND THE Q TOP AND BOTTOM OF THE RAMP A MINIMUM OF V-6". AS- BUILT FLOOR PLAN 6• ALL DOORS WILL HAVE A MINIMUM OF V--6" CLEAR ON THE LATCH (PULL) SIDE OF THE DOOR. (EXCEPT IN CERTAIN STATES WHERE IT WILL BE --- SCALE: 1 4" = 1'•-0" 2'-0") / 7• DOOR MATS AND THRESHOLDS TO BE A MAXIMUM OF 1/2" HIGH. 8. DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42" ABOVE THE FLOOR. �/� 9. DOORS TO HAZARDOUS AREAS TO HAVE KNURLED HANDLES. ,�t� .•'S;p' •. � 10. TOILETS: o v o r"*'""�""' �"'T"T-'� - ELECTRIC PANELS A. LAVATORY TO HAVE LEVER HANDLES, SPRING FAUCETS OR SELF n 1 I I I D- 29-1/�" O O_ no 1 DI I I DI PLY 1 H-78-3/Q• pO ICE METERING FAUCETS. I RACK I I Fi1CIf I B. A COAT HOOK 54" ABOVE THE FLOOR WILL BE MOUNTED ON THE o 4-J._J._8 9-JL-JL-� BACK SIDE OF THE HANDICAP STALL DOOR. ^J�3 '# E F. ! as y^� O pe s; C. LOCATE THE WATER CLOSET 18 FROM THE CENTER LINE OF THE �F •�•• (�' ► �_____ __- __-- -__ _ _ ___ _---- S Sink COOLATTA - -- -----��B_ Y_2-}__ _ __ ___ FIXTURE TO THE WALL. THE SEAT WILL BE 17" TO 19" ABOVE THE I T-6" optional FLOOR TO THE TOP OF SEAT. j= D/T COFFEE STATION COOLATTA STN. EXISTING --� PREP. AREA D. PROVIDE TWO 42" LONG x 1 1/2" OUTSIDE DIAMETER PENNED GRAB IU SERVING AREA (NO WORK) BARS, 1 1/2" FROM THE WALL WITH ONE BEHIND AT 6" FROM THE I� MENUBOARDS WALL AND ONE ADJACENT TO AT 12 FROM THE WALL 33 -36 IZ© 3 0" ESPRESSO 14'-0" COFFEE STATION 5'-6" PARALLEL TO AND ABOVE THE FLOOR. WHEN A TANK PREVENTS HAND-OFF THIS LOCATION OF REAR GRAB BAR INSTALL GRAB BAR 3" ABOVE �co Hot POS STATION THE TANK. '- NEW END PANEL Chocolate NEW 6 HIGH E. LAVATORY TO BE MOUNTED 32" ABOVE THE FINISHED FLOOR TO RIM 1-41 I 11 UP la & 3'--0" GATE _ n go END PANEL- OFFICE WITH KNEE SPACE OF 30" IN WIDTH AND 27" IN CLEAR HEIGHT. © N € � F WORK) I q " F. INSTALL MIRROR 36" ABOVE THE FINISHED FLOOR (TO BOTTOM) AND I ® True+mm-�crr 2 72 TO TOP. I L,s-ttf I G• DISPENSERS TO BE MOUNTED A MAXIMUM OF 42" ABOVE THE FLOOR Z 24-1/8"$44-1 4 I� TO ALL OPERATING OR DISPENSING SLOTS. 0 m 70 O DISPLAYi z O H. TOILET PAPER DISPENSERS MOUNTED 19" TO CENTER UNE ABOVE (n CD VDU O eEV. REF. �-` N, THE FLOOR. Z w 2 8„ (By Pepsi) ¢ 11. ACCESSIBLE PARKING SPACES, PASSENGER LOADING ZONES, RAMPS, AND Ld cl m SIGNAGE SHALL COMPLY WITH THE (ADA). z CONDIMENT 12: F-ON TOILET DOOR(S), SIGNAGE IS REQUIRED WITH RAISED LETTERS AND IN Cr - 1= BRAILLE INDICATING "MEN" OR "WOMEN". MOUNT 5' CENTER AFF OPENING Q Q SIDE OF DOOR. SIMILAR SIGNAGE REQUIRED IF BUTTONS PROVIDED. - Ud 2 2 0 11. FURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETE p ELECTRIC INSTALLATION OF CEMENT BOARD BACKING FOR F.R.P. AND CERAMIC TILE. co I = 4 4 `n TYPICAL SUBSTRATES FOR INTERIOR WALLS SHALL BE AS FOLLOWS: O - " EXISTING ADA CORE DRILLED ROOM A. PREP AREA AND STORAGE AREAS: 0'-0" TO 3'-0": 5/8" DUROCK CEMENT z = TABLE, REPLACE TABLETOP o BOARD, 3'-0" & ABOVE: 5/8" PLYWOOD. SERVICE AREA: 5/8" MIN. PLYWOOD AND CHAIRS WITH NEW. �+ B.. SALES AND SEATING AREAS: MIN. 5/8" GYPSUM BOARD. 12.GENERAL CONTRACTOR TO PROVIDE FOR P.O.S SYSTEM AS SHOWN ON ( •1, � ELECTRICAL DRAWINGS OR, AT A MINIMUM THE FOLLOWING CONDUITS; I E UT L. A. 2 1/2" I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP Clc D)] W.W. MOP WALL TO ABOVE CEILING. Q as"W.TABLE HTR. SINK `� B. FROM A HUB IN THE FRONT LINE CHASE UNDER SLAB TO WALL BEHIND r , I-- DISPLAY RACKS PROVIDE THREE (3) 2" CONDUITS WITH 2'-0" SWEEPS AT V 0 LiENDS. TERMINATE ABOVE THE CEILING. (UNDER FLOOR IF BASEMENT). 48"w.e-to eoarH C. 1" I.D. CONDUIT FROM BEHIND THE DRIVE THRU CASH STATION UP WALL TO .� W Q ABOVE CEILING, USE 2'-0" SWEEPS AT BOTTOM TO SIDE NEAREST FRAME " STORAGE WALL IF WINDOW BEHIND PROVIDING CHASE AS REQUIRED SO NO WIRING Ld BENDS LESS THAN 2'-0" :5RADIUS. aa•w.e-to-e BOOTH (NO WORK) D. 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE 0 w � /"� ^N OCOOLER CEILING. CENTER 32"x32"x3/4" PLYWOOD BLOCKING IN WALL FOR VDU UNIT. z 0 J > V I 0 ae w.raBLE EXISTING FREEZER NOTE THAT THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU(S) AND ITS F Q J TRASH " EXISTING DEDICATED CPU IS 75'-0" AND ONE TELEPHONE JACK IN OFFICE TO BE AN Q � Z �✓J 4s"W.BOOTH Li LjLj I DN LINE. NQ,TIF�' DUNKIN' DONUTS IF NOT REGIONALLY AVAIABI„�. U -"� Q W 2 2 REF E. OPTIONAL) 2x4 ELECTRICAL BOX IN FRONT LINE CHASE WITH 1 CONDUIT O Z OVER TO HUB AT MAIN CASH STATION. THIS IS FOR COUNTER MOUNTED � 4 4 VDU UNIT AT COFFEE STATION. mm Q W 13.NOTE: "P.O.S.", ALL POWER OUTLETS FOR P.O.S. DEVICES ARE DEDICATED -� CIRCUITS WITH THIRD WIRE ISOLATED GROUND. AN IG IS AN INSULATED WIRE, to SEPARATED FROM ALL OTHER GROUND ORES,MAIN OR OMPLLEX POWER PANEL. NEMA STANDARD RUNNING L5 BACK I.G.F RE BUILDING � I1 ZVESTIBULE SALES AREA \/EXISTING TOILETS RECEPTACLE AND PLUG. USE OF IG DUPLEX OR QUADPLEX OUTLETS: (I.E., • ^ (28 SEATS) HUBBELL IG-5262, IG-5362 OR EQUIVALENT). ry V) PROPOSEDFLOOR PLAN 14 DETERMINEDGC. SHALL PROCEED WITH CONSTRUCTION UNTIL V.D.U. LOCATIONS ARE O 0 W ADDITIONAL NOTES 15.COORDINATE UTILITY LOCATIONS NECESSARY FOR OPTIONAL TRAINING MODULE. I----• SCALE: 1/4" = 1'---0" 16.NOT USED. 1. EXISTING FLOOR TILE TO REMAIN. 17.PROVIDE WATER FILTRATION SYSTEM (BRANCH OFF MAIN UNE) FOR COFFEE Q - NEW MILLWORK TO RECEIVE BASE TO MATCH EXISTING TILE. BREWING EQUIPMENT, ICE MACHINES, POST MIX. LOCATE AS SHOWN. NOTE: - CRACKED TILES ARE TO BE REPLACED WITH MATCHING TILE. CONTRACTOR TO CONFIRM MATCH IN ADVANCE OF PROJECT COMMENCEMENT, 18,NOT USED. 7' MAX. SPACING TABLE TOP PROVIDE P&G DISPENSER W/ DEDICATED WATER SUPPLY ® REPLACE FLOOR TILES DAMAGED DURING CONSTRUCTION AS REQUIRED AND ALL EXISTING CRACKED TILES AS REQUIRED. 19.G.C. WILL BE RESPONSIBLE TO INSTALL ALL INTERIOR GRAPHIC ELEMENTS 4'-0" JANITOR'S SINK, (MOUNT BOTTLE & DISPENSER ABOVE SINK) 2. EXISTING CEILING GRID TO REMAIN. REPLACE TILES WITH NEW AS SHOWN ON SHEET A2. SUPPLED BY THE MILLWORK SUPPLER. & PROVIDE P&G DISPENSER W/ DEDICATED WATER SUPPLY 3• WALK--IN FREEZERL/LCOOLER TO REMAIN POWERED AND FUNCTIONAL THROUGHOUT DURATION OF PROJECT. 20•G.C. TO PROVIDE BRUSHED ALUMINUM CORNER GUARDS WITH 2" LEGS TO ALL 0 ro 0 1 X ® POT SINK (HAUNT BOTTLE & DISPENSER ABOVE SINK) IF 4 PACKED AND OBTAIN STAGED CONSTRUCTION ACCORDING SEQUENCE OF PROJECT AND TO FAC1LTi4TE LOADING JOBSTORAGE UNIT. MATERIALS WITHIN STORAGE UNIT ARE TO BE 21 BRONZE COLOR OUTSIDE MYLARCORNERS. RQLL DOWN SHADES ARE OPTIONAL AT GAZING. SHEET X I 0 1 z ¢ EITHER OR BOTH ARE NOT PRESENT. CONSULT DD N ¢ N 27" KNEE CORPORATE SPECS/ CONSTRUCTION MANAGER FOR MORE 5. REPLACE EXISTING LIGHTING WITH NEW AS SHOWN ON SHEET A2. REVIEW EXISTING EMERGENCY AND EXIT LIGHTS FOR CONDITION & REPLACE AS 22.TABLES ARE TO BE FREE STANDING EXCEPT FOR ADA TABLES, AND OTHERS = 19" CLR. CLEARANCE INFO. ALSO SEE NATIONAL ACCOUNTS. REQUIRED. HVAC DIFFUSERS AND GRILLES TO BE REFURBISHED. REPLACE IN APPROXIMATE LOCATION AS EXISTING. NOTED AS TO BE CORE DRILLED. SEE DETAIL ON SHEET K1. QUEUE RAIL D E AIL 2'_9y " 7. GENERAL CONTRACTOR O PLACE ALL NEW EQUIPMENT. 23.NOT TO PACE ALL EXISTING EQUIPMENT AS INDICATED ON EQUIPMENT PLAN. 24.THESESPLANS ARE BASED ON MINIMUM DUNKIN' BRANDS CORPORATE DESIGN PLAN ELEVATION 8. GENERAL CONTRACTOR TO MAKE ALL MECHANICAL, PLUMBING AND ELECTRICAL CONNECTIONS FOR ALL EQUIPMENT AS INDICATED ON EQUIPMENT PAN. REQUIREMENTS. THE STRUCTURAL DESIGN, FOOTING DESIGN, ADA COMPLIANCE 9. GENERAL CONTRACTOR TO DISCONNECT ALL EXISTING EQUIPMENT. AND GENERAL BUILDING REQUIREMENTS HAVE BEEN EVALUATED TO MEET ALL ~ MAXIMUM DISTANCE APART FOR A FIXED ACCESSIBLE TABLE '° EXISTING IF NEEDED FOR MENU BOARDS. IL ON SHEET A2. ALSO SEE BACK BAR ELEVATIONS ON SHEET K1 FOR NEW DIGITAL AND LOCAL CODES. MENUBOARD SYSTEM APPLICABLE VERIFY WITH OWNER AND DDCM 25.NOT USED JOB : D11100 TWO POST QUEING RAIL INSTALLATION SEE DETAIL ON SHEET K1 11. G.C. TO COORDINATE PERMIT, APPROVALS, AND LOCATION OF DUMPSTER AND STORAGE UNIT PRIOR TO STORE CLOSING. 26.OWNER'S MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING SHALL BE 7-0 12. BACK OF HOUSE TO BE THOROUGHLY CLEANED INCLUDING ALL WALLS, FLOORS, RACKS, ETC. VERIFY W/ OWNER AND DDCM. EXISTING HVAC EQUIPMENT AND MODIFYING AS REQUIRED BY NEW HEATING & DATE: 9-27--2011 13. G.C. TO PREPARE ALL WALLS, INCLUDING VESTIBULE, TO RECEIVE WALLCOVERING. COOLING LOADS. SUBMIT SHOP DRAWINGS FOR ARCHITECT APPROVAL BEFORE PC : 308834 ORDERING EQUIPMENT OR BEGINNING WORK. tC.M. R. ANDERSON