Loading...
HomeMy WebLinkAboutWell Correspondence 575 Foster Street (2) UAquatek Labs 3 Research Drive-Woodbridge, CT 06525 Water Analysis Report TEST ID: E031116084 DATE SAMPLED: 3/11/2016 TO: VANGUARD HOME INSPECTION 711 SAMPLE POINT: WELL TANK 87 BUTTONBALL LANE NO TREATMENT GLASTONBURY, CT 06033 SAMPLED BY: AL NAPIER PROPERTY LOCATION: 575 FOSTER STREET- SOUTH WINDSOR , CT BACTERIA ABSENT PRESENT LIMITS REF METHOD Coliform(Total) G ❑ ABSENT P SM 9223 E.Coli(Fecal) G ❑ ABSENT P SM 9223 Chlorine(Total) G ❑ ABSENT SM 4500-CI G PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL REF METHOD pH 7.2 SU 6.4-10 S 0 SM 4500-H B Turbidity 1.30 NTU 5 0.10 SM 2130 B Color ND CU 15 S 5 SM 2120 B Odor 1 TON 2 S 0 SM 2150 CHEMICALS RESULT UNITS LIMITS MRL REF METHOD Flouride ND mg/L 4 P 0.3 EPA 300.0 Chloride 19 mg/L 250 P 3 EPA 300.0 Nitrite Nitrogen ND mg/L 1 P 0.1 EPA 300.0 Nitrate Nitrogen 2.6 mg/L 10 P 1 EPA 300.0 Sulfate 13 mg/L 250 S 4 EPA 300.0 Calcium 20 mg/L NONE 0.5 SM 3111 B Magnesium 3 mg/L NONE 0.5 SM 3111 B Hardness 60 mg/L 200 S 4 SM 2340 B Sodium 9.4 mg/L 100 S 0.5 SM 3111 B Copper ND mg/L 1.3 S 0.04 SM 3111 B Iron 0.08 mg/L 0.3 S 0.04 SM 3111 B Manganese ND mg/L 0.05 S 0.04 SM 3111 B RADON WATER SINGLE RESULT UNITS LIMITS MRL REF METHOD Radon Water Single 733 pCi/L 5000 S 51 SM 7500-RN CONCLUSION: Based on the above results, this water was safe for drinking purposes at the time of collection. P=Primary limit,used to judge potability S=Secondary limit,recommended but not required L"- ^ „ MRL=Minimum Reportable Level /�/' *Limit exceeded David M.Graham,Ph.D. ND=None Detected Laboratory Director CT License#PH-0466,Aquatek Labs R=Reference Lab Work Page 1 of 1 for test# E031116084