Loading...
HomeMy WebLinkAboutSeptic Inspection 222Main Street Main St t R y p p yvastiwa# r .�IS1 Vl�ES, l�iic 2'7 Corrtn6Ypmr.B L�NfOsda!t„C7#)8'�.t1J'=, prt _ artfai=tiiltbr� P Address:222 Main St. Property Adress Town:South Windsor Town of Property Date:06/27/2013 12:43:16 UTC Date of Inspection Type of Dwelling or Use: Residential Name:Barbara Eddy Name of buyer Phone Number:860-416-5067 Buyers Phone number Mailing Address:250 Roxbery Rd. Buyer's Address Town:New Britain Buyer's Town State:CT Buyer's State Client Email: Gracelovesmom@yahoo.com Name of Buyer's Agent Agent Name:Fred Norman Name of Buyer's Agent Agent Phone Number:860-836-7149 Agent's Phone Number In4pectoes Name:Michael Norcross Company:Wastewater Services,Inc. Company Email:info@wastewaterservicesinc.com RECEIVED Company Phone Number:(860)871-2616 Company Address:21 Courtney drive JAN 2014 Town:Ellington SOUTH WINDSOR HEALTH DEPT. Page 1 State:CT Zipcode:06029 Disclaimer:THIS INSPECTION REPORT INDICATES THE PRESENT CONDITION OF THE PRIVATE ON- SITE SUBSURFACE SEWAGE DISPOSAL SYSTEM BASED ON RECOMMENDED INSPECTION PROCEDURES OUTLINED IN THIS REPORT.THE RESULTS OF THIS INSPECTION DOES NOT GUARANTEE OR WARRANTY FUTURE PERFORMANCE.THE INSPECTION REPORT EXCLUDES AND DOES NOT INTEND TO COVER COMPONENTS THAT ARE INACCESSIBLE(BY REASONABLE HAND DIGGING)OR ARE OTHERWISE NOT OBSERVABLE. Temperature:75 Condition at the time of inspection:Cloudy Inspection revealed:(Indicate one or more of the following): +� System functioning but is not necessarily sized per todays standards,no upgrade required. ✓ Need for component replacement and/or modification. Comments:The 1250 gallon single compartment concrete septic tank appears to be structurally sound.The septic tank was pumped out at the time of the inspection and should be pumped again in one year.The tank is located 22"below grade and needs a riser installed to bring access up to 12"to meet the CT Health Code.The distribution box was exposed and is badly deteriorated allowing sand and silt to enter the leach fields.The leach fields consist of two rows of pipe and stone trenches.The trenches had minimal ponding at the time of the inspection.This system is undersized for todays standards but should function under normal use. Recommendations:Install a new plastic distribution box was and riser over the center cover. Pump out the septic tank yearly Read literature provided Conserve water Note:The recipient of this report should discuss any deficiencies found by this inspection with the Inspector. Are there records of last pumping(s)?: No Copies of Pump out Reports Available:No Repair Permits:No Is a Location Drawing Available?: Yes Source of As-Built:Town Number of Bedrooms:4 Age of System:Tank:25+years. Age of System:Leaching Fields:25+years Number of People Occupying Dwelling: 1 Current Anticipated Occupance:4 Water Supply to Building:Public Water One Tank/One System:Yes Separate Gray&Black Water System:Yes Page 2 Does more than one sewer line leave the foundation?: No Is there a sump pump in the basement?: No Is there an in-home ejector pump?: No Does the kitchen sink have a garbage disposal?: No Is there a water treatment system present?: No Does the washing machine discharge into the septic tank?: No If discharge to a separate drywell,does it appear to be functional?: Yes Is there any Indication that sewage bypasses the septic system?: No 7�rrk]EV6 # h Type of Septic Tank:Single Compartment Tank Construction:Concrete Volume of Tank: 1250 Gallons Tank Condition:Operable Depth Below Grade:Other Depth Below Grade:Other: 22" Depth to Riser:Other Depth to Riser:Other: None '�an'k ��irmpon�nts; Inlet Baffle:Yes Type Component:Inlet Baffle: Full Partition Condition of Inlet Baffle:Operable Outlet Baffle:Yes Type of Outlet Baffle:Cast Center Condition of Outlet Baffle:Operable Effluent Filter:No Compartment Wall:No Inlet Pipe:Yes Type of Inlet Pipe:Cast Iron Condition of Inlet Pipe:Operable Has there been any indication of previous higher than normal levels of septage in the tank?: No Depth of liquid from inside top of tank:8" Was the tank pumped at the time of inspection?: Yes Did sewage flow back into the tank from the leaching fields?: No What was the amount of solid build-up in the tank at the time of inspection?: Excessive Is the system served by a pump and pump chamber?: No Type of System:Trenches Page 3 Is Information available on sqft of leaching System?: No Are there any structure or impermeable surfaces located over or near the leaching area?: No Were there signs of malfunctioning of leachfield?: No Does surface water,roof drains,or sump pump runoff drain onto the leaching area?: No Is there a distribution box present?: Yes Were distribution boxes exposed?: Yes Depth to Distribution boxes:Other Depth to Distribution boxes:Other: 2'10" What was found?: The distribution box was badly deteriorated Depth of leachfields:3' Was the leaching system probed?: Yes What was found?: The trenches had minimal ponding at the time of the inspection Were there any leaching galleries or drywells opened to observe present or past effluent levels?: No Is there an expansion/repair area avaiblable?: Likely Was a more in-depth investigation of leaching system conducted?: No Were there any conditions observed which might limit a repair?: No (Wetlands,ledge outcrops,streams,etc.) Image(1): 9 ``.• t y a` �w1 Page 4 Image(2): F� 1 � I 0 y: k;,� 1, '"'+ T g..- T2 ���� I .' k '3• �', ,.� .+.,.,_. .__. �r.. 4 . 'i��+s.. • I _ss a �v. �s �""� Caption for image(2): Tank Page 5 r � p Caption for Image(3): Distribufion b• ma¥4): �^z - ^»«® ��f2. - \ � : \ A �� \ ` « »^ ° . - � - . :. : � - \ ` � � � « Caption for image) Trench Inspector'sName:Michael Norcross Profession:I License Number:«« Not This form isaresult ofa Connecticut Environmental Health Association Cm&&e«n«m of members of the State A y Public Health,Local SAkms LicensedInstallers,CSew7Dispoa,Association,CT Association¥Realtors and thHome Inspection Industry.■has been Modified bWastewater Services,Inc. Email Report: -wastewaterinc@gmail.com Time Inspection Ended:124E52uc . PoiYered www.doForms.mm Page7 Septic System Loaction for: Z Z /tA N 5-- 1" A g SZAAA9 0 (1UI R W�a�f Point #1 #2 #3 #4 #S #6 #7 #8 A 8 P ri C