HomeMy WebLinkAboutSeptic Inspection 222Main Street Main St t R y
p p
yvastiwa# r .�IS1 Vl�ES, l�iic
2'7 Corrtn6Ypmr.B L�NfOsda!t„C7#)8'�.t1J'=,
prt _ artfai=tiiltbr�
P
Address:222 Main St.
Property Adress
Town:South Windsor
Town of Property
Date:06/27/2013 12:43:16 UTC
Date of Inspection
Type of Dwelling or Use: Residential
Name:Barbara Eddy
Name of buyer
Phone Number:860-416-5067
Buyers Phone number
Mailing Address:250 Roxbery Rd.
Buyer's Address
Town:New Britain
Buyer's Town
State:CT
Buyer's State
Client Email: Gracelovesmom@yahoo.com
Name of Buyer's Agent
Agent Name:Fred Norman
Name of Buyer's Agent
Agent Phone Number:860-836-7149
Agent's Phone Number
In4pectoes Name:Michael Norcross
Company:Wastewater Services,Inc.
Company Email:info@wastewaterservicesinc.com RECEIVED
Company Phone Number:(860)871-2616
Company Address:21 Courtney drive JAN 2014
Town:Ellington
SOUTH WINDSOR
HEALTH DEPT.
Page 1
State:CT
Zipcode:06029
Disclaimer:THIS INSPECTION REPORT INDICATES THE PRESENT CONDITION OF THE PRIVATE ON-
SITE SUBSURFACE SEWAGE DISPOSAL SYSTEM BASED ON RECOMMENDED INSPECTION
PROCEDURES OUTLINED IN THIS REPORT.THE RESULTS OF THIS INSPECTION DOES NOT
GUARANTEE OR WARRANTY FUTURE PERFORMANCE.THE INSPECTION REPORT EXCLUDES AND
DOES NOT INTEND TO COVER COMPONENTS THAT ARE INACCESSIBLE(BY REASONABLE HAND
DIGGING)OR ARE OTHERWISE NOT OBSERVABLE.
Temperature:75
Condition at the time of inspection:Cloudy
Inspection revealed:(Indicate one or more of the following):
+� System functioning but is not necessarily sized per todays standards,no upgrade required.
✓ Need for component replacement and/or modification.
Comments:The 1250 gallon single compartment concrete septic tank appears to be structurally sound.The
septic tank was pumped out at the time of the inspection and should be pumped again in one year.The tank is
located 22"below grade and needs a riser installed to bring access up to 12"to meet the CT Health Code.The
distribution box was exposed and is badly deteriorated allowing sand and silt to enter the leach fields.The leach
fields consist of two rows of pipe and stone trenches.The trenches had minimal ponding at the time of the
inspection.This system is undersized for todays standards but should function under normal use.
Recommendations:Install a new plastic distribution box was and riser over the center cover.
Pump out the septic tank yearly
Read literature provided
Conserve water
Note:The recipient of this report should discuss any deficiencies found by this inspection with the Inspector.
Are there records of last pumping(s)?: No
Copies of Pump out Reports Available:No
Repair Permits:No
Is a Location Drawing Available?: Yes
Source of As-Built:Town
Number of Bedrooms:4
Age of System:Tank:25+years.
Age of System:Leaching Fields:25+years
Number of People Occupying Dwelling: 1
Current
Anticipated Occupance:4
Water Supply to Building:Public Water
One Tank/One System:Yes
Separate Gray&Black Water System:Yes
Page 2
Does more than one sewer line leave the foundation?: No
Is there a sump pump in the basement?: No
Is there an in-home ejector pump?: No
Does the kitchen sink have a garbage disposal?: No
Is there a water treatment system present?: No
Does the washing machine discharge into the septic tank?: No
If discharge to a separate drywell,does it appear to be functional?: Yes
Is there any Indication that sewage bypasses the septic system?: No
7�rrk]EV6 # h
Type of Septic Tank:Single Compartment
Tank Construction:Concrete
Volume of Tank: 1250 Gallons
Tank Condition:Operable
Depth Below Grade:Other
Depth Below Grade:Other: 22"
Depth to Riser:Other
Depth to Riser:Other: None
'�an'k ��irmpon�nts;
Inlet Baffle:Yes
Type Component:Inlet Baffle: Full Partition
Condition of Inlet Baffle:Operable
Outlet Baffle:Yes
Type of Outlet Baffle:Cast Center
Condition of Outlet Baffle:Operable
Effluent Filter:No
Compartment Wall:No
Inlet Pipe:Yes
Type of Inlet Pipe:Cast Iron
Condition of Inlet Pipe:Operable
Has there been any indication of previous higher than normal levels of septage in the tank?: No
Depth of liquid from inside top of tank:8"
Was the tank pumped at the time of inspection?: Yes
Did sewage flow back into the tank from the leaching fields?: No
What was the amount of solid build-up in the tank at the time of inspection?: Excessive
Is the system served by a pump and pump chamber?: No
Type of System:Trenches
Page 3
Is Information available on sqft of leaching System?: No
Are there any structure or impermeable surfaces located over or near the leaching area?: No
Were there signs of malfunctioning of leachfield?: No
Does surface water,roof drains,or sump pump runoff drain onto the leaching area?: No
Is there a distribution box present?: Yes
Were distribution boxes exposed?: Yes
Depth to Distribution boxes:Other
Depth to Distribution boxes:Other: 2'10"
What was found?: The distribution box was badly deteriorated
Depth of leachfields:3'
Was the leaching system probed?: Yes
What was found?: The trenches had minimal ponding at the time of the inspection
Were there any leaching galleries or drywells opened to observe present or past effluent levels?: No
Is there an expansion/repair area avaiblable?: Likely
Was a more in-depth investigation of leaching system conducted?: No
Were there any conditions observed which might limit a repair?: No
(Wetlands,ledge outcrops,streams,etc.)
Image(1):
9
``.• t y
a`
�w1
Page 4
Image(2):
F�
1
� I 0
y:
k;,� 1, '"'+ T g..- T2 ���� I .' k '3•
�', ,.� .+.,.,_. .__. �r.. 4 . 'i��+s.. • I _ss a �v. �s �""�
Caption for image(2): Tank
Page 5
r �
p
Caption for Image(3): Distribufion b•
ma¥4):
�^z
-
^»«® ��f2.
-
\ �
:
\ A
�� \ `
« »^ °
. -
� -
. :.
: � -
\ ` � � � «
Caption for image) Trench
Inspector'sName:Michael Norcross
Profession:I
License Number:««
Not This form isaresult ofa Connecticut Environmental Health Association Cm&&e«n«m of members
of the State A y Public Health,Local SAkms LicensedInstallers,CSew7Dispoa,Association,CT
Association¥Realtors and thHome Inspection Industry.■has been Modified bWastewater Services,Inc.
Email Report:
-wastewaterinc@gmail.com
Time Inspection Ended:124E52uc .
PoiYered www.doForms.mm
Page7
Septic System Loaction for: Z Z
/tA N 5--
1"
A g
SZAAA9
0
(1UI R
W�a�f
Point #1 #2 #3 #4 #S #6 #7 #8
A
8 P ri
C