HomeMy WebLinkAboutWell Correspondence 29 Clinton Drive Connecticut Department of ENERGY & r^ qM ENVIRONMENTAL PROTECTION 79 Elm Street • Hartford,CT 06106-5127 www.ct.gov/deep Affirmative Action/Equal Opportu c +kti over Bureau of Water Protection and Land Reuse lygr ��+y' '� Remediation Division S ?Q OUT 1� N�CT /FpSOR William Coleman May 9,2013 T 29 Clinton Drive South Windsor,CT 06074 RE: Drinking Water Sample Results 29 Clinton Drive,South Windsor Dear Mr. Coleman: Please find enclosed copies of the analytical results for the drinking water samples collected from the above-referenced property. The samples were collected from the granular-activated carbon(GAC) filtration system prior to treatment(well head and raw water) and after treatment (after 1st GAC and after 2nd GAC). The water samples were collected by a Department of Energy and Environmental Protection (DEEP) representative on fuly 13th, 2012 and were analyzed for the presence of Volatile Organic Compounds (VOCs) at the Department of Public Health (DPH) Laboratory using EPA test method 524.2 as the result of a historic release in 2007 from the home heating fuel oil above ground storage tank at an adjacent property (see Table 1). In the water samples that were collected, the following compounds were detected at the levels indicated below: Table 1 Residential Well Sampling Results Collected on July 13,2012 WELL HEAD COWQUIVD CONCENTRATION RAW WATER AFTER 15T FILTER AFTER 2ND FILTER STATE MICROGRAMS Ppk .CONCENTRATION CC?NCENTRATION: CONCENTRATION. DRINKING LITER L) {jig/L)' WATER CRITERIA VOCs VOCs VOCs VOCs VOCs Various concentrations concentrations concentrations concentrations Criteria were <any were <any were <any were <any State DWALs State DWALs State DWALs State DWALs 1 29 Clinton Drive,South Windsor , A DEEP representative collected water samples from the granular-activated carbon (GAC) filtration system prior to treatment (raw water) and after treatment (after 1st GAC and after 2nd GAC) on March 26th, 2013. The water samples collected were analyzed for the presence of Extractable Total Petroleum Hydrocarbons (ETPH), hydrocarbon odor and Volatile Organic Compounds (VOCs) at the DPH Laboratory using EPA test method 3520 for CT ETPH,CT SOP for odor, and EPA test method 524.2 for VOCs (See Table 2). In the water samples that were collected, the following compounds were detected at the levels indicated below: Table 2 Residential Well Sampling Results Collected on March 26,2013 RAW WATER STATE CONCENTRATION DRINKING AFTER 1s'FILTER AFTER 2NBILTER COMPOUND lyIICROGRAMS PER WATER CONCENTRATION CONCENTRATION LI ER CRITERIA wg�L) Aµg/L) (µSA) Extractable Total Petroleum <100 <100 <100 250* Hydrocarbons (ETPH) 1-5 Odor,Intensity 1 Not tested 0 units State Guideline Odor, Description Hydrocarbon Not tested Not tested VOCs VOCs VOCs VOCs concentrations concentrations concentrations Various were < any State were < any State were <any State Criteria DWALs DWALs DWALs 2 29 Clinton Drive,South Windsor * Groundwater Protection Criteria (GWPC). Although there is no State drinking water action level for ETPH per se, the reported concentration does not exceed the Department's GWPC needed to clean up groundwater in areas where drinking wells are in use. The criterion is currently 250 µg/L, (based on formal approval from DEEP to use Preliminary Draft 2008 RSRs Revisions to the Groundwater Protection Criteria) and is a health risk based number. A concentration with a "<" (less than) designation signifies that there may be a trace amount of this compound in your well that is below the laboratory detection limit. None of the reported concentrations of ETPH and VOCs for any of the water samples that were collected were found to exceed applicable drinking water criteria or the State's Groundwater Protection Criteria. Although a hydrocarbon odor was detected in the raw water sample, the reported level (1) is within an acceptable range. Based on the results,pre and post filter samples (after first and second GAC filter),your drinking water is potable. The filter system is operating properly satisfactorily. The lab result sheets are attached. If you have any further questions regarding these results,you may contact me at(860) 424-3796. You may also contact the Connecticut DPH's Division of Environmental Epidemiology & Occupational Health at (860) 509-7742 for additional information about the toxicity of specific chemicals found in drinking water. Sincerely, MaryAnne Danyluk Environmental Analyst 2 Remediation Division DEEP/Bureau of Water Protection and Land Reuse Enclosures Copy: QUOINW,Environmental Health Officer,South Windsor Town Hall, 1540 Sullivan Avenue,South Windsor,CT 06074 Karen Steele,45 Clinton Drive,South Windsor,CT 06074 3 t