Loading...
HomeMy WebLinkAboutSeptic Repair 2504 Ellington Road �O Town of South Windsor — Health Department Sep 24 1g40 Sullivan Avenue, South Windsor, CT 06074 S Z012 Phone: 860-644-2611 ext. 248 Fax: 860-644-7280 H C�w'/VD N DFpT R APPLICATION FOR APPROVAL TO CONSTRUCT A SUBSURFACE SEWAGE DISPOSAL SYSTEM El & A ot-,(.0&k Application/Permit To the Director of Health,Town o£ 50 WJ9' 5())L— Date: -` r Application is hereby made for an approval to construct a subsurface sewage disposal system for a: 91, 96h tr, ` C 1X0 G� -�4 r� (Residential Building,Restaurant,Retail Building,etc.) located at: a �(!q -/A/6?bAI Rd. �(�vr# (Street Address,Lot Number,Subdivision Nam ,Map,Block,Lot,etc.) New System Addition Repair Other Owner fwd VIL&ITO Address ( 50 bWPA-1D'V PJ Tel.No0b_ /q V7-89,51 (AwI hfNf C� Address Tel'. QQ L t Installer ;I YA R�' bb Cot-ynt�r� Te1.No. O�a✓�� ��17 ��� Installer License No. 0®375co' In accordance with detailed information stated below: Application fee paid 10.00 Signed (Owner or duly authorized representative) ------------------------------------------------------------------------------------------------------------------------------------- N6GENERAL INFORMATION Soil Tests Conducted(Date): I Lot size am sq.ft. Area of Special Concern(Y/N): If yes,Reason(s): Basis of Design(#of Bedrooms,Restaurant Seats,Building Size,etc.): Engineered Plan Required(Y/N): If yes,Name of Engineer: Address of Engineer: Design Plan Approved(Y/N): A-�_Date of Approved Plan: '1, Revision Date: Type of Water Supply %N A If well,has location been approved(Y/N): Well Driller's Name: Address: OFFICE USE ONLY Approval to Construct issued by: Jm, •\I /\"-(- Dater (Director of Health r Registered Sanitarian) Signature: Title: Town of South Windsor - Health Department Subsurface Sewage Disposal System Inspection Report PROPERTY LOCATION: DSCH o BOTTOM OF EXCAVATION: DATE: N INITIAL PERCOLATION TEST "FILL CHECK": DATE: INITIAL DEPTH HOLE# DEPTH HOLE# TIME READING TIME READING PERC PERC FINAL INSPECTION: SANITARIAN DATE: 1. SEWER LINE: A. SEWER LINE CEMENTED AT FOUNDATI (Y/N) ................PIPE LENGTH Sy B. PITCH(.25 inches per foot min)REQUIRED LIA c '° FT................PROVIDED FT D. PIPE TYPE&ASTM SPEC. 506,�• L�13 .................................PIPE SIZE(INCHES) L" 2. SEPTIC TANK: 15-[G Lo-t i- I Obo c ; `► A. MANUFACTURER-Xr`C\ -mK►ob0 DATE MFD—r" r*----SIZE.CoW " " 1,2ss-1 GALLONS B. TANK COMPARTMENTS PLACED PROPERLY(Y/N)................................................ I( C. INLET BAFFLE(not in middle of opening). ` ..........OBSERVATION OPENING(slag removal)-&4 D. OUTLET BAFFLE FILTER TYPES RISERS NEEDED(Y/N) SIZE E. TYPE OF PIPE (approved by code) 3 PUMP CHAMBER/GREASE TRAP: A. PUMP CHAMBER MANUFACTURER ...SIZE GALLONS B. TYPE PUMP ............PUMP ALARM CHECKED (Y/N) C. FLOAT CONTROL ELEVATION VERIFIED(Y/N). ....TYPE OF PIPE D. GREASE INTERCEPTOR TANK SIZE GALLONS........MANUFACTURER 4. D BOXES: A. LEVEL(Y/N) SERIAL DISTRIBUTION(High level overflow within top 3")...... C. LEVEL SYSTEM(Ends tied together)(Y/N ) 5. TRENCHES: A. LENGTH OF TRENCH............ 1. 2. 3. 4. 5. 6. B. GALLERIES(stone around all units).1. 2. 3. 4. 5. 6. C. CENTER-TO-CENTER SPACING FILTER FABRIC PRESENT(Y/N) TYPE D. APPROVED AGGREGATE FREE OF SILT DIRT&DEBRIS (Y/N). F. AGGREGATE MEETS PHC SPECIFICATIONS(Y/N) TYPE OF PIPE G. LEACHING SYSTEM DESCRIPTION: 6. SEPARATION DISTANCES CONFORM WITH APPROVED PLAN(Y/N) STRATION DISTANCES FIELD VERIFIED (Y/N) PASS FAIL COMMENTS: } of- U WELL INSPEC : SAN DATE: WELL LOCATION Sanitary Well Cap Rev.April 2012 FINAL INSPECTION ELEVATIONS PROPERTY LOCATION: -S&A W f` TOWN: S, l u"ti or PROPERTY OWNER: P�wr, G:\1❑a r k� f- ow.\ SANITARIAN: Cl�:ln � DATE: LEVEL TO BENCHMARK(ROD READING) BENCHMARK ELEVATION HEIGHT OF LEVEL. Wilij SEWER LINE AT FOUNDATION SEPTIC TANK INLET SEPTIC TANK OUTLET O PUMP/GREASE TRAP INLET PUMP/GREASE TRAP OUTLET D-BOX# 1 INLET 1 G FLOWLINE RIGHT FLOWLINE LEFT OUTLET D-BOX#2 INLET FLOWLINE RIGHT FLOWLINE LEFT OUTLET D-BOX#3 INLET FLOWLINE RIGHT FLOWLINE LEFT OUTLET TRENCH # 1 RIGHT LEFT TRENCH # 2 RIGHT LEFT TRENCH # 3 _ RIGHT LEFT INVERT ELEVATION=Top of Pipe+Diameter of Pipe—Height of Level HEIGHT OF LEVEL=Benchmark+Rod Reading Reference: Paee 2