HomeMy WebLinkAboutPools Inspection 18000000 chapel road x r Tnwn.of South Windsor—Health Department 'Routine.Inspection 6 Indoor Pool0 Re-inspection !Outdoor Pool
1540 Sullivan Avenue,S.Windsor,CT 06074 0 Complaint 0 Wading Pool
Phone: 860-644-2511 x248 Fax: 860-644-7280 0 Other: 0 Whirlpool/Spa
ii Public Swimming Pool Inspection Report
Name of Facility: CI�oaCwN -Ai I` Inspection Date: 4',)-311
C-4 1 1
_YY
Address: (�® Phone:
Items marked with an X indicate non-compliance with Cr Public Health Code(Section 19-13-1333b). Violations must be corrected by the listed compliance date.
a-4 Life Saving Equipment b-12 Vacuuming
Ring buoy <15"inner diameter,attached to 50ft length of/<"line pool vacuumed to maintain cleanliness
Life pole/shepard's crook with blunted ends,a b-13 Accessibility to Pool Area
minimum of 12ft in length utdoor pools surrounded by barrier(>4ft)
Outdoor pool entry b-1 00l Construction p gates self-closing and self
Pool in good repair latching
b-2 Supervisory Personnel Pool access restricted when pool is closed
Knowledgeable pool supervisor onsite b-14 Lifeguards
List of personnel provided to Health Dept. arning signs if no lifeguard on duty(letters
>4" high)
b-4 Pool Water Clarity Warning signs visible from all entry 6"secchi disk at pool bottom visible v _ g g points in
b-5 Pool Water Disinfection pool area
b-15 First Aid Kit
Automatic Feeder Used>0.8 mg/liter free Chlorine Kit filled, ready for use,materials current
b-S, b- Test Kits mer. Red Cross 24-unit first aid kit or equiv.
DPD Test Kit onsite(for disinfectant and pH) b-16 Emergency Telephone
b-6 Pool Water pH Telephone readily available in:pool area Value between 7.2 and 7.8 b-17 Signs
b-7 Records and Testing "All persons shall bathe with water and soap
entering pool"
/ R before esidual disinfectant&pH tested prior to daily "Anyone having a communicable disease shall
lv opening Daily of use the pool"
.pool testing records kept(2 times/daily) "S "tting,or blowing the nose in the pool is
b-8 Decks,Dressing,Toilet&Shower Rooms rohibited"
Clean,good repair,well ventilated "Running, boisterous or rough play is
0.5%chlorine cleaning solution for floors prohibited"
Shower water 90—105 degrees F b-18 Emergency Communications
Adequate toilet facilities Directions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment posted at entrance
Maintained in good repair,clean/sanitary Telephone numbers(print>.25„)of police,fire,
V_.,- Skimmers,gutters, strainer baskets clean and in hospital and EMS
'good repair b-19 egistration
Drain grates compliant Name of owner or owner's agent,address and
b-10 Deck Equipment location on file
V< Handrails provided on steps, stepholes,and c-1 Depth Markers
ladders rkers on rim at min and max depth and
Equipment properly secured points of slope change
b-11 Pool Chemical Storage Markers visible from pool deck and from within
LX Stored in a cool,dry, clean,well-ventilated area pool
Containers stored tightly closed
Public Swimming Pool Inspection Report
2
c-2 Lifeguard stands — Comments:
Lifeguard stand raised A least Oft ay `
Lifeguard stand located pool side adjacent to
deep end dA --) '-\ 3 0
c-4 Sign
"No diving is permitted off the deck into
shallow areas of the poop"
Additional Requirements for Public Spas: ���
e-1 Pool Water Disinfection �/ 4ot� J b� ,fir C�m`
Free available chlorine residual k-0 mg/liter
when spa in use .lam 11-F
e-2 Pool Water Temperature
Water temperature shall not exceed 104
degrees F
e-3 Depth Markerszrr
Minimum 2 markers located on rim or
adjacent to pool
e-4 Precaution Signs
"Elderly persons and those suffering from
Heart Disease,Diabetes, High or Low Blood
Pressure,shall not enter the spa"
"Unsupervised use by children is prohibited"
"Do not use while under the influence of
alcohol/drugs"
"Do not use alone"
"Observe a reasonable time limit(preferably
less than 15 min.):long exposures may result
in nausea,dizziness,or fainting"
e-5 Oils,Body Lotions,and Soaps
Oils,body lotions&soaps must be removed
prior to spa use
Pool Supervisor: 0A Date:
(Pri t N me)
(Signature)
Health Inspector: Title:_ �✓
(Signature) __�Y
DATE OF COMPLIANCE: VK'nr Am _ Re-inspection Required: 0 YES •NO
S.Windsor—April 2011