Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Well Inspection 65 Beelzebub Road
REQUEST FOR ORGANICS/RADIATION WATER EXAMINATION STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH LABORATORY PO BOX 1689,HARTFORD,CONNECTICUT 06144 10 CLINTON STREET,HARTFORD,CONNECTICUT 06106 Organic Chemistry Section: (860) 509-8647/Special Chemistry Section: (860)509-8535 Bottles Received Accession Label South Windsor Healthealth Dept. ept. Dr.Gerald Schwartz 1540 Sullivan Ave. ❑ PUBLIC PRIVATE South Windsor,CT 06074 . .., E GO1NPLi=TED�B1(� OLLECTaORR0.� "am Town Date Collected ` Time Collected Number = (MMIDDIYYYY)FoR/M/ �6 ' i (MinuryTime) � Hrs Name of Ublitx or Property Owner Collectors Sample Number ®s Kold Source Address of Sample Collection 6 L 8 1(�OM IT Collected By Collectors Title Q NV Collectors Phone Number Town and State of Sample Collection Zip Code REMARKS Additional Information:Complaints, Requests,Treatments Etc.) _ WATER TEST REQUEST y F t :. 55 ORGANICS RADIATION ❑ 100J EPA 524.2 VOLATILE ORGANICS ❑ 916R EPA 900.0 GROSS ALPHA ❑ 01 OH EPA 504.1 EDB AND DBCP ❑ 917R EPA 900.0 GROSS BETA ❑ 1830 EPA 525.2 SEMI-VOLATILE ORGANICS ❑ 919R EPA 903.0 RADIUM 226 1060 EPA 505 ORGANOCHLORINE PESTICIDES ❑ 918R EPA 903.0 RADIUM 228 ❑ 1760 EPA 515.3 CHLORINATED HERBICIDES ❑ 915R EPA 913.0 RADON 222 ❑ 1780 EPA 531.1 CARBAMATES&CARBAMOYLOXIMES ❑ 920R EPA 908.0 URANIUM ❑ 1790 EPA 547 GLYPHOSATE ❑ 151 R EPA 905.0 STRONTIUM 89 ❑ 1810 EPA 549.2 DIQUAT ❑ 152R EPA 905.0 STRONTIUM 90 ❑ 1840 EPA 8260b VOLATILE ORGANICS ❑ 155R EPA 902.0 IODINE 131 100H CT ETPH ❑ 511 R EPA 906.0 TRITIUM ❑ OTHER ❑ 504R EPA 901.1 GAMMA ❑ OTHER Rev.42009 REQUEST FOR ORGANICS/RADIATION WATER EXAMINATION STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH LABORATORY PO BOX 1689,HARTFORD,CONNECTICUT 06144 10 CLINTON STREET,HARTFORD,CONNECTICUT 06106 Organic Chemistry Section: (860) 509-8547/Special Chemistry Section: (860)609-8535 Bottles Received Accession Label D06074 South Windsor health Dept. Dr.Gerald Schwartz ❑ PUBLIC PRIVATE 1540 Sullivan Ave. South Windsor,CT 06074 - Town Date Collected / Time Collected L 1 Number (MM/DD/YYYY) HM (W. taryri—)/ 3 Hr$ Name of Utili or Property Owner Collector's Sample Number P � I ) 10111 Source Address of Sample Collection gON -r l 4 EEL. E Rd I) Collected By Collector's Title Collectors Phone Number Town and State of Sample Collection ZiR Code 4 IW-�tjlolslaW, l lc�i I I I lddohh - REMARKS Additional Information:Complaints,Requests,Treatments, Etc. g - E o _._ � ,Y s ,.; WATER EST REQUESTg 511F f ORGANICS RADIATION ❑ 100J EPA 524.2 VOLATILE ORGANICS ❑ 916R EPA 900.0 GROSS ALPHA ❑ 01 OH EPA 504.1 EDB AND DBCP ❑ 917R EPA 900.0 GROSS BETA ❑ 1830 EPA 525.2 SEMI-VOLATILE ORGANICS ❑ 919R EPA 903.0 RADIUM 226 V 1060 EPA 505 ORGANOCHLORINE PESTICIDES ❑ 918R EPA 903.0 RADIUM 228 ❑ 1760 EPA 515.3 CHLORINATED HERBICIDES ❑ 915R EPA 913.0 RADON 222 ❑ 1780 EPA 531.1 CARBAMATES&CARBAMOYLOXIMES ❑ 920R EPA 908.0 URANIUM Ll 1790 EPA 547 GLYPHOSATE ❑ 151 R EPA 905.0 STRONTIUM 89 ❑ 1810 EPA 549.2 DIQUAT ❑ 152R EPA 905.0 STRONTIUM 90 ❑ 1840 EPA 8260b VOLATILE ORGANICS ❑ 155R EPA 902.0 IODINE 131 ❑ 100H CT ETPH ❑ 511 R EPA 906.0 TRITIUM ❑ OTHER ❑ 504R EPA 901.1 GAMMA ❑ OTHER Rev.4/2009 REQUEST FOR ORGANICS/RADIATION WATER EXAMINATION 211.Ar STATE OF CONNECTICUT $� DEPARTMENT OF PUBLIC HEALTH LABORATORY PO BOX 1689,HARTFORD,CONNECTICUT 06144 10 CLINTON STREET, HARTFORD,CONNECTICUT 06106 Organic Chemistry Section: (860)509-85471 Special Chemistry Section: (860)609-8535 Bottles Received Accession Label D06074 South Windsor Health Dept. Dr.Gerald Schwartz 1540 Sullivan Ave. 0 PUBLIC PRIVATE South Windsor,CT 06074 ,_•. �.._ R�_������',��, �.: ��ECOMRLfi'ED.,�3Y,��OLLEC�''�f!2*���� ���-� �` �- �, Town Date Co11e�Yd � �>© / _ d ' Time Collected �j Number MM/DD/ / (Mirrtary Time) I H rS Name of Utili or Pro ert Owner Collectors Sam to Number 6S P O 1 Source Address of Sample Collection c-° 19 Collected By Collector's Title V Collectors Phone Number Town and State of Sample Collection Zip Code 1"§01skd"I W-jw�-SW-J MOM+ REMARKS Additional Information:Complaints, Requests,Treatments, Etc. ORGANICS RADIATION ❑ 100J EPA 524.2 VOLATILE ORGANICS ❑ 916R EPA 900.0 GROSS ALPHA ❑ 010H EPA 504.1 EDB AND DBCP ❑ 917R EPA 900.0 GROSS BETA ❑ 1830 EPA 525.2 SEMI-VOLATILE ORGANICS ❑ 919R EPA 903.0 RADIUM 226 ly 1060 EPA 505 ORGANOCHLORINE PESTICIDES ❑ 918R EPA 903.0 RADIUM 228 ❑ 1760 EPA 515.3 CHLORINATED HERBICIDES ❑ 915R EPA 913.0 RADON 222 ❑ 1780 EPA 531.1 CARBAMATES&CARBAMOYLOXIMES ❑ 920R EPA 908.0 URANIUM ❑ 1790 EPA 547 GLYPHOSATE ❑ 151 R EPA 905.0 STRONTIUM 89 ❑ 1810 EPA 549.2 DIQUAT ❑ 152R EPA 905.0 STRONTIUM 90 ❑ 1840 EPA 8260b VOLATILE ORGANICS ❑ 155R EPA 902.0 IODINE 131 CT ETPH ❑ 511 R EPA 906.0 TRITIUM ❑ OTHER ❑ 504R EPA 901.1 GAMMA 0 OTHER Rev.4/2009 REQUEST FOR ORGANICS/RADIATION WATER EXAMINATION STATE OF CONNECTICUT Wr DEPARTMENT OF PUBLIC HEALTH LABORATORY PO BOX 1689,HARTFORD,CONNECTICUT 06144 10 CLINTON STREET,HARTFORD,CONNECTICUT 06106 Organic Chemistry Section: (860) 609-8647/Special Chemistry Section: (860)509-8535 Bottles Received Accession Label D06074 South Windsor Health Dept. Dr.Gerald Schwartz ❑ PUBLIC PRIVATE 1540 Sullivan Ave. South Windsor,CT 06074 - r- a ?05- OECOIUIPL )=DBYCOLLE_CXDRR � ��� `� �< �. s Town =' ' - Date Collected o '-7 /551/F�� � Time Collected I H rs Number MM/DD/ MirrtaryTime Name of UtilitX or Property Owner Collectors Sample Number tb�s�--IW I Tc-H I 1 17 Source Address of Sample Collection b Collected B Collectors Title V, Collectors Phone Number Town and State of Sample Collection ZipCode eKo - 6yy - I ► © lo © -TM REMARKS Additional Information:Complaints, Requests,Treatments,Etc. K _. ER.TST REQI�EST n3f ORGANICS RADIATION ❑ 100J EPA 524.2 VOLATILE ORGANICS ❑ 916R EPA 900.0 GROSS ALPHA ❑ 01OH EPA 504.1 EDB AND DBCP ❑ 917k EPA 900.0 GROSS BETA ❑ 1830 EPA 525.2 SEMI-VOLATILE ORGANICS ❑ 919R EPA 903.0 RADIUM 226 1060 EPA 505 ORGANOCHLORINE PESTICIDES ❑ 918R EPA 903.0 RADIUM 228 ❑ 1760 EPA 515.3 CHLORINATED HERBICIDES ❑ 915R EPA 913.0 RADON 222 ❑ 1780 EPA 531.1 CARBAMATES&CARBAMOYLOXIMES ❑ 920R EPA 908.0 URANIUM ❑ 1790 EPA 547 GLYPHOSATE ❑ 151 R EPA 905.0 STRONTIUM 89 ❑ 1810 EPA 549.2 DIQUAT ❑ 152R EPA 905.0 STRONTIUM 90 ❑ 1840 EPA 8260b VOLATILE ORGANICS ❑ 155R EPA 902.0 IODINE 131 ❑ 100H CT ETPH ❑ 511 R EPA 906.0 TRITIUM ❑ OTHER ❑ 504R EPA 901.1 GAMMA ❑ OTHER Rev.4/2DD9 SOWN Sfq o � F Tim O-P siou� � C U 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 SOR•CO TELEPHONE (860)644-2511 August 2,2011 Joseph&Faye Bond 65 Beelzebub Road South Windsor,CT 06074 Dear Mr.&Mrs.Bond, In response to your request,on July 20,2011 this department collected samples of the water supplied by the private well located on your property at 65 Beelzebub Road in South Windsor. The samples were delivered to the State of Connecticut Department of Public Health laboratory to be analyzed,using EPA method 505,for the detection of organohalide pesticides and commercial polychlorinated biphenyls (PCB)products in the water. According to the laboratory report,the compounds chlordane(technical)and dieldrin were not detected in your potable water supply. I have enclosed a copy of the report for you to review. Please do not hesitate to contact me if you have any questions at 860-644-2511 ext.248. Sincerely, 4SerR ,BS,HHS Environmental Health Officer Enc.CT Department of Public Health laboratory report(report date 7/26/11) cc: MaryAnne Danyluk,CT DEEP,Remediation Section, Bureau of Waste Management ::::::::::::::IiisFi::;:::::::::::::::::::::::::::::::::::: Fq:.wCA.701A::: .'.}::;::::::(�t\'iiL7.1.U7�4:7:::C�1[ ::::::Y.�T'i/ :•i:•i:•iii::: }}yy i STATE OF CONNE TICUT '��'��'���`�• NR:100 18025766 D06074 0 11 Department of Public Health Laboratory :<;::;:::;:::;:.....;::::::::>..... >::>::::>::>:....:.............:..;..:..:;...::::::::>::»::; ::>: <::<:>::>::>:;:» Clinical Testing License:CL-0197 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 JOSEPH BOND Hartford,CT 06144 Telephone(860)509-8500 65 BEELZEBUB SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH GERALD SCHWARTZ MD 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 13:37 15:19 15:42 FINAL REPORT W SAMPLE :.:::::.•:::::::::::.::•:::: ::: ::...........:........................#................................................................................................................:...................................:. SAMPLING POINT: WATER TANK COLLECTOR: SHERRY ROY TITLE: ENV ** PESTICIDES METHOD ---------------------------------------------- ANALYTICAL METHOD - EPA METHOD 505 ANALYSIS OF ORGANOHALIDE PESTICIDES AND COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB) PRODUCTS IN WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY ----------------------------------------------- Date Extracted 07/25/2011 ,Date Analyzed 07/25/2011 . RESULTS Compound Result MDL PQL Aldrin ND 0.005 0.03 Alachlor ND 0.079 0.3 Atrazine ND 0.415 * 1.4 Alpha Chlordane ND 0.004 0.03 Gamma Chlordane ND 0.008 0.03 Chlordane(Technical) ND 0.070 0.3 Dieldrin ND 0.007 0.03 Endrin ND 0.005 0.03 Heptachlor ND 0.008 0.03 Heptachlor Epoxide ND 0.008 0.03 Hexachlorobenzene ND 0.007 0.03 Hexachlorocylopentadiene ND 0.007 0.03 Lindane ND 0.008 0.03 Methoxychlor ND 0.036 0.14 Cis-Nonachlor ND 0.006 0.03 Trans-Nonachlor ND 0.005 0.03 Simazine ND 0.827 ** 1.4 Toxaphene ND 1.357 3.0 Aroclor 1016 ND N/A N/A ,. Aroclor 1221 ND N/A N/A Aroclor 1232 ND N/A N/A Aroclor 1242 ND N/A N/A Aroclor 1248 ND N/A N/A *** CONTINUED *** FORM NO. OL-6A REV.3-00 100 STATE OF CONNECTICUT �c:':::::>:::>s:>:::::'111��ESS#.f�i•�1:i+t:':�::�< �•'•[,ti'.�[.T:°:1���>:)k'fi"•r U... :...::::..:.. ..:...::. K NR:100 18025766 D06074 0 12 Department of Public Health Laborato ry Clinical Testing License:CL-0197 10 Clinton St. 132SOUTH WINDSOR 1 P.O.Box 1689 JOSEPH BOND Hartford,CT 06144 Telephone(860)509-8500 65 BEELZEBUB SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH GERALD SCHWARTZ MD 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 13:37 15:19 15:42 .. ........... ;: FINAL REPORT W SAMPLE :::::::::> .:::::'.:::s>:::........... r ....................................................................................... S1J 3...........................................................................:.......................:...........................:..................... ..::... :::::::.:::::::::.::::::::....::................................................................... ........................................................................................................:::::::::.:....................::::::....... Aroclor 1254 ND N/A N/A Aroclor 1260 ND N/A N/A Butachlor ND N/A N/A Propachlor ND 0.165 0.3 Metolachlor ND N/A N/A Metribuzin ND N/A N/A p,p' -DDE ND N/A N/A p,p' -DDD ND N/A N/A p,p' -DDT ND N/A N/A ND = None Detected (Result Less Than The PQL) PQL = Practical Quantitation Limit MDL = Method Detection Limit All values expressed in ug/L (ppb) Values are calculated based on a Signal/Noise Ratio 5:1 according to CFR Part 136 Appendix B * The 2.2 multiple of the MDL for this compound excee the federal upper control limit (UCL) of 0.22 **The 2.2 multiple of the MDL for this compound exceed the federal upper control limit (UCL) of 0.154 ****QUALITY ASSURANCE NOTE**** he recovery of Propachlor, Simazine, and Atrazine in the Laboratory Fortified Sample Matrix were elow the acceptance criteria due to a matrix interference. Results for these analytes are questionable. ------ ** END OF REPORT ** FORM NO. OL-6A REV.3-00 100 ::ii::i::i::Ii�Y:i::i::::::i::i:::}4iy;}:i::i::�Ri9.'i:G�33.O7A:::f7/.�Y.:i::i::� ��`i�:tJ�' i::.' t':�{y�.XJ ?�;i :::;:j:i;};iv:: �:• : STATE OF CONNECTICUT :..:::...................................................:...................................:...:.. NR:101 18025767 ID06074 0 1 Department of Public Health Laborato >::>;»:»::»:;:>::;::s;:;:::>::s..:...: •::•:::>::::>::>:::::>: Clinical Testing License:CL-0197 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 JOSEPH BOND Hartford,CT 06144 Telephone(860)509-8500 65 BEELZEBUB SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH GERALD SCHWARTZ MD 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 13:38 15:19 15:42 ........ .. FINAL REPORT ::>::>::>#:>::>:s::::>::::> #... SAMPLING POINT: CARBON FILTER #1 COLLECTOR: SHERRY ROY TITLE: ENV ** PESTICIDES METHOD ---------------------------------------------- ANALYTICAL METHOD - EPA METHOD 505 ANALYSIS OF ORGANOHALIDE PESTICIDES AND COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB) PRODUCTS IN WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY ---------------------------------------------- Date Extracted 07/25/2011 Date Analyzed 07/25/2011 RESULTS Compound Result MDL PQL Aldrin ND 0.005 0.03 Alachlor ND 0.079 0.3 Atrazine ND 0.415 * 1.4 Alpha Chlordane ND 0.004 0.03 Gamma Chlordane ND 0.008 0.03 Chlordane(Technical) ND 0.070 0.3 Dieldrin ND 0.007 0.03 Endrin ND 0.005 0.03 Heptachlor ND 0.008 0.03 Heptachlor Epoxide ND 0.008 0.03 Hexachlorobenzene ND 0.007 0.03 Hexachlorocylopentadiene ND 0.007 0.03 Lindane ND 0.008 0.03 Methoxychlor ND 0.036 0.14 Cis-Nonachlor ND 0.006 0.03 Trans-Nonachlor ND 0.005 0.03 Simazine ND 0.827 ** 1.4 Toxaphene ND 1.357 3.0 Aroclor 1016 ND N/A N/A Aroclor 1221 ND N/A N/A Aroclor 1232 ND N/A N/A Aroclor 1242 ND N/A N/A Aroclor 1248 ND N/A N/A *** CONTINUED *** FORM NO. OL-6A REV.3-00 100 #JK''•::::::::>?::: :::: :s //:.•.�;.Y.�+K }} 1 i�t (..... Y........ 14 R.R i.•.t�l:ii+/.'isi::i....':........7JL�4:1.::.:: ..::,,i:Y.►�'i/ :j:;:jj:: STATE OF CONNECTICUT NR:101 18025767 ID06074 0 1 12 Department of Public Health Laboratory :::::::::::::::::::::::. Clinical Testing License:CL-0197 1 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 JOSEPH BOND Hartford,CT 06144 Telephone(860)509-8500 65 BEELZEBUB SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH GERALDSCHWARTZ MD •::........................................................ ..:::::::::::::::::.�::::::. 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 13:38 15:19 15:42 ;: FINAL REPORT Now : :: .::. .............................................................................................. .................::::::::::::.:::::::::::.:::::.:::. .............................................................................................. Aroclor 1254 ND N/A N/A Aroclor 1260 ND N/A N/A Butachlor ND N/A N/A Propachlor ND 0.165 0.3 Metolachlor ND N/A N/A Metribuzin ND N/A N/A p,p' -DDE ND N/A N/A p,p' -DDD ND N/A N/A p,p' -DDT ND N/A N/A ND = None Detected (Result Less Than The PQL) PQL = Practical Quantitation Limit MDL = Method Detection Limit All values expressed in ug/L (ppb) Values are calculated based on a Signal/Noise Ratio 5:1 according to CFR Part 136 Appendix B * The 2.2 multiple of the MDL for this compound excee the federal upper control limit (UCL) of 0.22 **The 2.2 multiple of the MDL for this compound exceed the federal upper control limit (UCL) of 0.154 ****QUALITY ASSURANCE NOTE**** he recovery of Propachlor, Simazine, and Atrazine in the Laboratory Fortified Sample Matrix were elow the acceptance criteria due to a matrix interference. Results for these analytes are questionable. 1 ------ ** END OF REPORT ** FORM NO. OL-6A REV.3-00 100 ....................... STATE OF CONNECTICUT ....... NR:102 18025768 ID06074 0 i Deparunent of Public Health Laboratory . ... .............. . ..... . ..........: I X... N- .. ......... Clinical Testing License:CL-0197 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 Hartford,CT 06144 JOSEPH BOND Telephone(860)509-8500 65 BEELZEBUB SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH .................. ........ GERALD SCHWARTZ MD 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 13:39 15:19 15:42 FINAL REPORT ...... ... ......... ............................. .............................. ........ .. . .. ......... .... . .. . ..... ............... ... ...... . .......I . .. . . ....... ................ ........ .... .. ... .... .. . . ...... .. .... ............ .............. .. .................... .... ....... .... ......................... ................ ............................ .............. ................ ........ ......... ............ ........................ ............ .................%........................... .......... ...... .... ..X.%.111'..X:. . ........... ....................I...... ......... ....... SAMPLING POINT: CARBON FILTER #2 COLLECTOR: SHERRY ROY TITLE: ENV PESTICIDES METHOD ---------------------------------------------- ANALYTICAL METHOD - EPA METHOD 505 ANALYSIS OF ORGANOHALIDE PESTICIDES AND COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB) PRODUCTS IN WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY ---------------------------------------------- Date Extracted 07/25/2011 Date Analyzed 07/26/2011 RESULTS Compound Result MDL PQL Aldrin ND 0.005 0.03 Alachlor ND 0.079 0.3 Atrazine ND 0.415 1.4 Alpha Chlordane ND 0.004 0.03 Gamma Chlordane ND 0.008 0.03 Chlordane(Technical) ND 0.070 0.3 Dieldrin ND 0.007 0.03 Endrin ND 0.005 0.03 Heptachlor ND 0.008 0.03 Heptachlor Epoxide ND 0.008 0.03 Hexachlorobenzene ND 0.007 0.03 Hexachlorocylopentadiene ND 0.007 0.03 Lindane ND 0.008 0.03 Methoxychlor ND 0.036 0.14 Cis-Nonachlor ND 0.006 0.03 Trans-Nonachlor ND 0.005 0.03 Simazine ND 0.827 1.4 Toxaphene ND 1.357 3.0 Aroclor 1016 ND N/A N/A Aroclor 1221 ND N/A N/A Aroclor 1232 ND N/A N/A Aroclor 1242 ND N/A N/A Aroclor 1248 ND N/A N/A CONTINUED FORM NO. OL-6A REV.3-00 100 ::::i::::i:::fi Yi:i::::::i :::::::::i::::::::::i 7:iC3. Di•A:i .. STATE OF CONNECTICUT >.:.>:<:>:::::..........:...:..:....:.:...........:....: ...:...............................:..........:..:.......:: ....:: .:::.;'::::.: ; . NR:102 18025768 D06074 0 2 Department of Public Health Laboratory ; :>::>::>::> :>:: >::.,.:...........: : .:::•:•::::::•::::•:::::::::.:::::::::::::::::::. • Clinical Testing License:CL-0197 t 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 JOSEPH BOND Hartford,CT 06144 Telephone(860)509-8500 65 BEELZEBUB SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH GERALDSCHWARTZ MD ::................................................................:.:::.:::::::::.:... 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 13:39 15:19 15:42 .......................... .......................... ................................ > lE# 1t7» FINAL REPORT »>? titt?lEt ... ....................................................... � ....#..}.......................................................v........v...........:.:..:....................::............................................. Aroclor 1254 ND N/A N/A Aroclor 1260 ND N/A N/A Butachlor ND N/A N/A Propachlor ND 0.165 0.3 Metolachlor ND N/A N/A Metribuzin ND N/A N/A p,p' -DDE ND N/A N/A p,p' -DDD ND N/A N/A p,p' -DDT ND N/A N/A ND = None Detected (Result Less Than The PQL) PQL = Practical Quantitation Limit MDL = Method Detection Limit All values expressed in ug/L (ppb) Values are calculated based on a Signal/Noise Ratio 5:1 according to CFR Part 136 Appendix B * The 2.2 multiple of the MDL for this compound excee the federal upper control limit (UCL) of 0.22 **The 2.2 multiple of the MDL for this compound exceed the federal upper control limit (UCL) of 0.154 ****QUALITY ASSURANCE NOTE**** The recovery of Propachlor, Simazine, and Atrazine in the Laboratory Fortified Sample Matrix were below the acceptance criteria due to a matrix interference. Results for these analytes are questionable. ------ ** END OF REPORT ** FORM NO. OL-6A REV.3-00 100 STATE OF CONNECTICUT NR:103 18025769 ID06074 0 1 1 1 Department of Public Health Laboratory >::>::>::»::>;::::::;>;s::>::»::>:c;::::r;::::::::>::».:::........:::::::: :•:•::.:::::::::::::::::::::.::::.::.:::. Clinical Testing License:CL-0197IX 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 FIELD BLANK Hartford,CT 06144 Telephone(860)509-8500 SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH GERALD SCHWARTZ MD 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 00.00 15:19 08:17 .......................... T. ........... FINAL REPORT :::::::::::::::::::::>::::>::>::::> .........................................:...:.:::.:::::::::::::::::......................................................................... ..).................:.::.::::::::::::.:::.:::::.:......................................................................................::::........... SAMPLING POINT: BLANKS COLLECTOR: SHERRY ROY TITLE: ENV ** PESTICIDES METHOD ---------------------------------------------- ANALYTICAL METHOD - EPA METHOD 505 ANALYSIS OF ORGANOHALIDE PESTICIDES AND COMMERCIAL POLYCHLORINATED BIPHENYLS (PCB) PRODUCTS IN WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY ---------------------------------------------- Date Extracted 07/25/2011 Date Analyzed 07/25/2011 RESULTS Compound Result MDL PQL Aldrin ND 0.005 0.03 Alachlor ND 0.079 0.3 Atrazine ND 0.415 * 1.4 Alpha Chlordane ND 0.004 0.03 Gamma Chlordane ND 0.008 0.03 Chlordane(Technical) ND 0.070 0.3 Dieldrin ND 0.007 0.03 Endrin ND 0.005 0.03 Heptachlor ND 0.008 0.03 Heptachlor Epoxide ND 0.008 0.03 Hexachlorobenzene ND 0.007 0.03 Hexachlorocylopentadiene ND 0.007 0.03 Lindane ND 0.008 0.03 Methoxychlor ND 0.036 0.14 Cis-Nonachlor ND 0.006 0.03 Trans-Nonachlor ND 0.005 0.03 Simazine ND 0.827 ** 1.4 Toxaphene ND 1.357 3.0 Aroclor 1016 ND N/A N/A Aroclor 1221 ND N/A N/A Aroclor 1232 ND N/A N/A Aroclor 1242 ND N/A N/A Aroclor 1248 ND N/A N/A *** CONTINUED *** FORM NO. OL-6A REV.3-00 100 ::::::::::::::::fii::::::::::::::::::::::::::::::::;?:::::::t.L''•i'G'.Ridgy\::: i::::::::...(!'\'..iLU7�121•:::4�lSi::A::i:: ::i:::::: :::::::::::::::i::i`•.1Y : STATE OF CONNECTICUT "''' NR:103 18025769 D06074 0 1 12 Department of Public Health Laboratory m Clinical Testing License:CL-0197 10 Clinton St. 132SOUTH WINDSOR P.O.Box 1689 FIELD BLANK Hartford,CT 06144 Telephone(860)509-8500 SOUTH WINDSOR CT 06074 SOUTH WINDSOR DIR OF HEALTH GERALD SCHWARTZ MD .:.>: #.::.;:.>:;I .;:.;: :.;:.::::>::>:< C'4 :::>:.: 1540 SULLIVAN A 07/20/11 07/20/11 07/26/11 SOUTH WINDSOR CT 06074 00:00 15:19 08:17 ...... .. ........ FINAL REPORT ::: :::..::.:::.:....................................: :..:..................................::::::............ :..:::::::::::::::::::::::::::.:::.:.::::::::::.:::#::.:.......................................................................................................................................::::::•:::::. Aroclor 1254 ND N/A N/A Aroclor 1260 ND N/A N/A Butachlor ND N/A N/A Propachlor ND 0.165 0.3 Metolachlor ND N/A N/A Metribuzin ND N/A N/A p,p' -DDE ND N/A N/A p,p' -DDD ND N/A N/A p,p' -DDT ND N/A N/A ND = None Detected (Result Less Than The PQL) PQL = Practical Quantitation Limit MDL = Method Detection Limit All values expressed in ug/L (ppb) Values are calculated based on a Signal/Noise Ratio 5:1 according to CFR Part 136 Appendix B * The 2.2 multiple of the MDL for this compound excee the federal upper control limit (UCL) of 0.22 **The 2.2 multiple of the MDL for this compound exceed the federal upper control limit (UCL) of 0.154 ------ ** END OF REPORT ** FORM No. OL-6A REV.3-00 100