HomeMy WebLinkAboutPools Inspection 9999 Chapel Road Town Of South Win dSOi"-Health Department /Routine Inspection 0 Indoor Pool0 Re-inspection /Outdoor Pool
1540 Sullivan Avenue,S.Windsor,CT 06074 0 Complaint 0 Wading Pool
Phone: 860-644-2511 x248 Fax: 860-644-7280 0 Other: IL 0 Whirlpool/Spa
Public Swimming Pool Inspection Report
Name of Facility: I I hodIn< Inspection Date: ��!/
Address: �tiQ i A3�►,C Spr- Phone:
Items marked with X indicate non-compliance with Cr Public Health Code(Section 19-13-1333b). Violations must be corrected by the listed compliance date.
a-4 z'Iftsaving Equipment b-12 Vacuuming
ng buoy<15"inner diameter,attached to
50ft length of%" line Pool vacuumed to maintain cleanliness
i s
Life pole/shepard's crook with blunted ends,a b-13 Accessibility to Pool Area
minimum of 12ft in length putdoor pools surrounded by barrier(>4ft)
b-1 Pool Construction 9.utdoor pool entry gates self-closing and self
latching
,,-,Pool 194bod repair
e Pool access restricted when pool is closed
b-2 S rvisory Personnel
Knowledgeable pool supervisor onsite b-14 " eguards
List of personnel provided to Health Dept. Wa ng signs if no lifeguard on duty(letters
" high)
b-4 Pool Water Clarity
Warning signs visible from all entry points in
6"secchi disk at pool bottom visible
pool area
b-5 Pool Water Disinfection
b-15 First Aid Kit
Automatic Feeder Used
Kit filled,ready for use, materials current
>0.8 mg/liter Free Chlorine
b-5, b-6 Test Kits Amer. Red Cross 24-unit first aid kit or equiv.
b-16 Emergency Telephone
DPD Test Kit onsite(for disinfectant and pH)
Telephone readily available in pool area
b-6 Pool Water pH
b-17 Signs
Value between 7.2 and 7.8 *
b-7 Words and Testing "AII persons shall bathe with water and soap
before entering pool
esidual disinfectant&pH tested prior to daily "Anyone having a communicable disease shall
opening not use the pool"
Daily pool testing records kept(2 times/daily) "Spitting,or blowing the nose in the pool is
b-8 Decks, Dressing,Toilet&Shower Rooms Zj prohibited"
Clean,good repair,well ventilated "Running, boisterous or rough play is
fl.5%chlorine cleaning solution for floors prohibited"
Shower water 90-105 degrees F b-18 fimergency Communications
Adequate toilet facilities Dir ions to nearest telephone and first-aid kit
b-9 Equipment rooms/areas&Equipment osted at entrance
Maintained in good repair,clean/sanitary Telephone numbers (print>.25")of police,fire,
Skimmers,gutters,strainer baskets clean and in hospital and EMS
1/ good repair b-19 Registration
Drain grates compliant Name of owner or owner's agent,address and
b-10 Deck Equipment z location on file k- .
Handrails provided on steps, stepholes,and c-1 -Depth Markers
ladders Markers on rim at min and max depth and
Equipment properly secured points of slope change
b-11 Pool Chemical Storage Markers visible from pool deck and from within
Stored in a cool,dry,clean,well-ventilated area pool
Containers stored tightly closed
Public Swimming Pool Inspection Report
2
c-2 lifeguard stands Comments:
Lifeguard stand raised at least Oft
Lifeguard stand located pool side adjacent to
deep end _7
c-4 Sign Noe, 04514kk
"No diving is permitted off the deck into c v Yc . s
shallow areas of the pool"
Additional Requirements for Public Spas: i \
e-1 Pool Water Disinfection �5 5 �.,er ,c�c�c,M\��5 Srie,•
Free available chlorine residual>1.0 mg/liter when spa in use
e-2 Pool Water Temperature
Water temperature shall not exceed 104
degrees F
e-3 Depth Markers
Minimum 2 markers located on rim or `.
adjacent to pool +k
e-4 Precaution Signs
"Elderly persons and those suffering from
Heart Disease,Diabetes, High or Low Blood
Pressure,shall not enter the spa"
"Unsupervised use by children is prohibited"
"Do not use while under the influence of
alcohol/drugs"
"Do not use alone"
"Observe a reasonable time limit(preferably
less than 15 min.): long exposures may result
in nausea,dizziness,or fainting"
e-5 Oils,Body Lotions,and Soaps
Oils, body lotions&soaps must be removed
prior to spa use
Pool Supervisor: _Is S �'OAIZIW(U Date:
(Print Name)
V'N;� . - 4
(si at re)
Health Inspector: Title: nyirc�nrn2h a �
(signs ure)
DATE OF COMPLIANCE: ('W_ Re-inspection Required: 0 YES •NO
S.Windsor—April 2011