HomeMy WebLinkAboutWell Inspection 517 Miller Road (2) STATE OF CONNECTICUT
DEPARTMENT OF ENVIRONMENTAL PROTECTION
QV/ y�51 -
��4NS/V�
f
August 9, 2000
Nicole Peters
517 Miller Road
South Windsor, CT 06074
RE: Water Sampling Results for 517 Miller Road, South Windsor, CT
Dear Mrs. Peters:
Enclosed please find a copy of the laboratory results for the water samples that were collected
from your house on July 21,2000. The water samples were analyzed for the presence of volatile
organic compounds(VOCs).
As the laboratory results indicate,the chemical compound 1,1,1-trichloroethane and chloroform
were identified in the water sample at concentrations of 0.6 micrograms per liter(ug/1)and 0.8
ug/1,respectively. The Connecticut Department of Public Health(CTDPH)has established the
drinking water action level for 1,1,1-trichloroethane at a concentration of 200 ug/1. The CTDPH
has not established a drinking water action level for chloroform. Therefore,the water supply at
your home is potable with respect to the constituents tested.
Please be apprised that an environmental consulting firm contracted by the Town of South
Windsor will be monitoring your drinking water supply in the future.
If you have any questions regarding the above,please call me at(860)-424-3782.
Sincerely,
Michael P. Senyk
Environmental Analyst
Permitting, Enforcement and Remediation Division
cc: Robert Deptula, Sanitarian, Town of South Windsor
(Printed on Recycled Paper)
79 Elm Street • Hartford, CT 06106-5127
http://dep.state.ct.us
An Equal Opportunity Employer
0^braHng Connecticut Coastal Resource anag�ent:�-2-
STATE OF CONNECTICUT
Department of Public Health
Division of Laboratory Services 6NR4-517MILLE 1 b 12507b A00142 0
10 Clinton St.
P.O.Box 1689 INFORMATION
Hartford,CT 06144
TELEPHONE:(860)509-8500 132SOU7 H WINDSOR
517 MILLER RD.
SOUTH WINDSOR CT
DEP—P.E.R.D, POTABLE WATER
0
o, i5 14', 16 12;24
""—7(1-)(T/---.
0
79 ELM ST. 07�2 11 CNI 7/21/00 08/02/()('
L HARTFORD CT 06106
FI
NAL REPORT
SAMPLING POINT: KITCHEN SINK
COLLECTOR: SENYK, M. TITLEZ ANALYST
PRIVATE WEUL TREATMENT:
ATE ANALYZED 7/31/00
ANALYTICAL METHOD, EPA METHOD 524.2
MEASUREMENT OF ORGANIC COMPOUNDS IN WATER BY
CAPIl.-LARY C.,0LUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY.
PA 524.2 FINAL RESULT:
COMPOUND QUANTITY (UG/L)
BENZENE ND
BROMOBENZENE ND
BROMOCHLOROMETHANE ND
BROMODICIALOROMETHANE ND
BROMOFORM ND
BROMOMETHANE ND
N--BUTYLBENZENE ND
SEC—BUTYLBENZENE ND
TERT—BUTYLBENZENE ND
10 CAR)3ON TETRACHLORIDE ND
4- CHLOROBENZENE ND
0 CHLOROETHANE ND
!ep S%
CHLOROFORM 0.8
CHLOROMETHANE ND
2--CHLOROTOLUENE ND
oaP 4—CHLOROTOLUENE ND
DIBROMOCHLOROMETHANE ND
1 ,2—DIBROMO-3—CHLOR.OPROPANE ND
1 ,2—DIBROMOETHANE ND
DIBROMOMETHANE ND
1 ,2—DICHLOROBENZENE ND
1 ,3—DICHLOROBENZENE ND
174--DICHLOROBENZENE ND
DICHLORODIFLUOROMETHANE ND
1 , 1-DICHLOROETHANE ND
CONTINUED
1M NO.OL-6A REV.10-99
STATE OF CONNECTICUT •
Department of Public Health
Division of Laboratory Services NR;517MILLE 116125076 IA00142 0
10 Clinton St. INFORMATION
P.O.Box 1689
Hartford,CT 06144
TELEPHONE:(860)509-8500 132SOUTH WINDSOR
IN R 0,'5 17 M I L 7LE
517 MILLER RD.
SOUTH WINDSOR CT
DEP—P.E.R.D. P01"ABLE WATER
7 21(_j� _
7r 14, 16 12:24
1:4-M�����
79 ELM ST. 07/21/0C 07/21/00 08/02/0
L HARTFORD CT 061o6
WFINAL REPORT
1 ,2—DICHLOROETHANE ND
1 , 1--DICHLOROETHENE ND
CIS-1 ,2—DICHLOROETHENE ND
TRANS-1 ,2—DICHLOROETHENE ND
1 ,2—DICHLOROPROPANE ND
1 ,3—DICHLOROPROPANE ND
4.,2--1.-ICHL0ROPROFANE ND
Irl—DICHLOROPROPENE ND
CTS-1 ,3—DICHLOROPROPENE ND
TRANS-1 ,7—DICHLOROPROPENE ND
ETHYLBENZENE ND
HEXACHLOROBUTADIENE ND
ISOPROPYLBENZENE ND
4--ISOPROPYLTOLIJENE ND
METHYLENE CHLORIDE ND
METHYL T—BUTYL ETHER ND
NAPHTHALENE ND
PROPYLBENZENE ND
STYRENE ND
1 , 1 . 1 .2—TETRACHLOROETHANE ND
1 , 1r2y2—TETRACHLOROETHANE ND
TETRACHLOROETHENE ND
TOLUENE ND
IY2,3—TRICHLOROBENZENE ND
1r2r4—TRICHLOROBENZENE ND
1 , 1 , 1—TRICHLOROETHANE 0.6
1 , 1 ,2—TRICHLOROETHANE ND
pp TRICHLOROETHENE ND
bw, 00 TRICHLOROFLUOROMETHANE ND
1 ,2,3—TRICHLOROPROPAIME ND
1r2,4—TRIMETHYLBENZENE ND
1r3r5—TRIMETHYLBENZENE ND
VINYL CHLORIDE ND
M r O r P—X%YLENES (TOTAL) ND
NOTE; ND = NONE DETECTED
METHOD DETECTION LIMIT IS 0.5 UG/L FOR ABOVE
COMPOUNDS.
------ END OF REPORT
:ORM NO.OL-6A REV.10-99