HomeMy WebLinkAboutWell Inspection 890 Foster Street Extens (3) STATE OF CONNECTICUT
DEPARTMENT OF ENVIRONMENTAL PROTECTION
QW gM�1
►11�Mt1yG
f
November 30, 2000
Mr. Ken Hebert
890 Foster Street Extension
South Windsor, CT 06074
RE: Water Sampling Results for 890 Foster Street Extension, South Windsor, CT
Dear Mr. Hebert:
Enclosed please find a copy of the laboratory results for the water samples that were collected
from your home on November 9, 2000. The water sample was analyzed for the presence of
volatile organic compounds (VOCs).
As the laboratory results indicate,no VOCs were detected in the water sample. Therefore,the
drinking water at your home is potable with respect to the constituents tested.
Please be apprised that the Connecticut Department of Environmental Protection(CTDEP)may
periodically monitor your drinking water supply.
If you have any questions regarding the above,please call me at(860)-424-3782.
Sincerely,
Michael P. Senyk
Environmental Analyst
Permitting,Enforcement and Remediation Division
cc: Robert Deptula, Sanitarian, Town of South Windsor
{Printed on Recycled Paper)
79 Elm Street • Hartford, CT 06106- 5127
http://dep.state.ct.us
A Eual Opportunity Employer
Cekbr.t�ingC.nnec�utlCoaslal Resource Management:1980-2000
• rSTATE OF CONNECTICUT •
Department of Public Health
Division of Laboratory Services :8 —FO*a 16126351 AOC1142 d
10 Clinton.St: 77
L_
•• •
P.O.Box 1689
Hartford,CT 06144 132SOUTH W I NDSOR
TELEPHONE:(860)509-8500 HEBERt KEN
F 890 FOSTER ST'
SOUTH WINDSOR CT
DEP-P.E.R.D. POTABLE WATER
79 ELM ST. 711 (c,
/OD 11/09/00 11/2D/(
L HARTFORD CT 061Db � 15: 17 131-52
REPORT COMMENT
FINAL .REPORT
TEST(S) RESULT(S)
SAMPLING POINT OUTSIDE TAP
COLLECTOR; RICHARDS, GIL TITLE: E.A.
PRIVATE WELL. TREATMENT:
DATE ANALYZED 11/14/00
__------------------ -.-_-_-----____-_..-_----__------------
ANALYTICAL METHOD: EPA METHOD 524.2
MEASUREMENT OF ORGANIC COMPOUNDS IN WATER BY
CAPILLARY COLUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY.
--------------------------------------------------------
EPA 524.2 INAL RESULT;
RECEIVED COMPOUND QUANTITY (UG/L)
ENZENE ND
NOV 2 12000 ROMOBENZENE ND
RQMOCHLOROMETHANE ND
ROMODICHLOROMETHANE ND
WATER MANAGEMENT BUREAU ROMOFORM ND
ROMOMETHANE ND
--BUTYLBENZENE ND
EC-BUTYLBENZENE ND
ERT-BUTYLBENZENE ND
ARBON TETRACHLORIDE ND
HLOROBENZENE ND
HLOROETHANE ND
HLOROFORM ND
HLOROMETHANE ND
-CHLOROTOLUENE ND
-CHLOROTOLUENE. ND
IBROMOCHLOROMETHANE ND
,Z-DIBROMO-3-CHLOROPROPANE ND
2--DI BROMOETHANE ND
IBROMOMETHANE ND
r 2--D I CHLOROBENZENE ND
.3--DICHLOROBENZENE ND
r4—DICHLOROBENZENE ND
ICHLORODIFLUOROMETHANE ND
, I--DICHLOROETHANE ND
***. CONT I UED
FORM NO.OL-6A REV.10-99
STATE OF CONNECTICUT •
Department of Public Health
Division of Laboratory Services
10 Clinton St
P.O.Box 1689 INF•• ON
Hartford,CT 06144 132SOUTH W I NDSOR
TELEPHONE:(860)509-8500 HEBER r KEN
-I 890 FOSTER ST
SOUTH WINDSOR CT
DEP-P.E.R.D. POTABLE WATER k,Mmmmmmmmmw COLLECTED RECEIVED
, -
79 ELM ST. 11/09/00 11/09/00 11/20/0(
L HARTFORD CT 04106 1030 15. 17 13:52
•.• COMMENT
F NAL REPORT
TEST(S) RESULT(S)
r2--DICHLOROETHANE ND
r1-DICHLOROETHENE ND
IS-1r2-b,ICHLOROETHENE ND
RAMS-1r2-DICHLOROETHENE ND
r2-DICHLOROPROPANE ND
r3-DICHLOROPROPANE ND
2,2-DICHLOROPROPANE ND
r1-DICHLOROPROPENE ND
IS-1r3-DICHLOROPROPENE ND
RANS-1r3-DICHLOROPROPENE ND
THYLBENZENE ND
EXACHLOROBUTADIENE ND
SOPROPYLBENZENE ND
-ISOPROPYLTOLUENE ND
ETHYLENE CHLORIDE ND
ETHYL T-BUTYL ETHER ND
APHTHALENE ND
ROPYLBENZENE ND
TYRENE ND
rlr1r2-TETRACHLOROETHANE ND
: lr2r2-TETRACHLOROETHANE ND
ETRACHLOROETHENE ND
OLUENE . ND
r2r3-TRICHLOROBENZENE ND
r2r4-TRICHLOROBENZENE ND
r1r1-TRICHLOROETHANE ND
r1r2-TRICHLOROETHANE ND
RICHLOROETHENE ND
RICHLOROFLUOROMETHANE ND
rZr.3-TRICHLOROPROPANE ND
r2r4-TRIMETHYLBENZENE ND
r3r5-TRIMETHYLBENZENE ND
INYL CHLORIDE ND
rOrP-XYLENES (TOTAL) ND
N TE. ND = NONE DETECTED
M THOD DETECTION LIMIT IS 0.5 UG/L FOR ABOVE
C MPOUNDS.
\ ---------- END OF REPORT
FORM NO.OL-6A REV.10-99