HomeMy WebLinkAboutWell Inspection 911 Foster Street Extens STATE OF CONNECTICUT
DEPARTMENT OF ENVIRONMENTAL PROTECTION
reAwsrpq
r
November 27, 2000
Albert Lebrun
911 Foster Street Ext.
South Windsor, CT 06074
RE: Water Sampling Results for 911 Foster Street Ext., South Windsor, CT
Dear Sir or Madam:
Enclosed please find a copy of the laboratory results for the water samples that were collected
from your home on October 31,2000. The water samples were analyzed for the presence of
volatile organic compounds(VOCs).
As the laboratory results indicate,the chemical compound trichloroethene was identified in your
water supply at a concentration of 4.7 micrograms per liter. The Connecticut Department of
Public Health(DPH)has established the drinking water action level for trichloroethene at a
concentration of 5 micrograms per liter.
Based on the concentration of trichloroethene in your water supply,the Department of
Environmental Protection(DEP)has taken steps to install a granular activated carbon(GAC)
filter system on your water supply. The GAC filter system is an effective means of removing the
trichloroethene from your water supply. The system will be maintained and monitored by the
DEP until such time your home is connected to the municipal water main.
If you have any questions regarding the above,please call me at(860)-424-3782.
Sincerely,
Michael P. Senyk .
Environmental Analyst
Permitting, Enforcement and Remediation Division
cc: Robert Deptula, Sanitarian, Town of South Windsor
( Printed on Recycled Paper)
79 Elm Street • Hartford, CT 06106- 5127
http://dep.state.ct.us
An Equal Opportunity Employer
elebrating Connecticut Coastal Resource Management:1980-2000
STATE OF CONNECTICUT •
Department of Public Health
Division of Laboratory Services ■
10 Clinton St.
P.O.Box 1689 INFORMATION
Hartford,CT 06144 132SOUTH W I NDSOR
TELEPHONE:(860)509-8500 ALBERT LEBRUN
F 911 FOSTER ST
SOUTH WINDSOR CT
DEP-P.E.R.D. POTABLE WATER ,•_ •
79 ELM ST. 10/31/0 10/31/00 11/09/C
L HARTFORD CT 06106 10: 10 15:27 08:20
� REPORT COMMENT
SAMPLING POINT: OUTSIDE TAP
COLLECTOR: SENYK, M TITLE: ANALYST
PRIVATE WELL TREATMENT:
DATE ANALYZED 11/3/00
------------------------------------------------------------
ANALYTICAL METHOD: EPA METHOD 524.2
MEASUREMENT OF ORGANIC COMPOUNDS IN WATER BY
CAPILLARY COLUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY.
---------------------_-___--_-----_---- -------------------
EPA 524.2 INAL RESULT:
COMPOUND QUANTITY (UG/L)
BENZENE ND
ROMOBENZENE ND
ROMOCHLOROMETHANE ND
�q ROMODICHLOROMETHANE ND
— ROMOFORM ND
�� ROMOMETHANE ND
-BUTYLBENZENE ND
)EC-BUTYLBENZENE ND
�O ERT-BUTYLBENZENE ND
ARBON TETRACHLORIDE ND
HLOROBENZENE ND
sgc HLOROETHANE ND
HLOROFORM ND
HLOROMETHANE ND
--CHLOROTOLUENE ND
-CHLOROTOLUENE ND
IBROMOCHLOROMETHANE ND
1 ,2-DIBROMO-3--CHLOROPROPANE ND
1 ,2-DIBROMOETHANE ND
IBROMOMETHANE ND
1 ,2-DICHLOROBENZ.ENE ND
1 ,3-DICHLOROBENZENE ND
1 ,4--DICHLOROBENZENE ND
i ICHLORODIFLUOROMETHANE ND
1 , 1-DICHLOROETHANE ND
CONTI UED
FORM NO.OL-6A REV.10-99
`~ STATE OF CONNECTICUT •
Department of Public Health
Division of Laboratory Services
10 Clinton St.
•- •
P.O.Box 1689
Hartford,CT 06144 132SOUTH W I-NDSOR
TELEPHONE:(860)509-8500 ALBERT LEBRUN
F 911 FOSTER ST
SOUTH WINDSOR CT
DEP—P.E.R.D. POTABLE WATER „•-
79 ELM ST. 10/31/0 10/31/00 11/09/0(
L HARTFORD CT 0610E► � 10: 1p 15;2? 08;20
••• COMMENT
TEST(S) RESULT(S)
1r2—DICHLOROETHANE ND
1r1—DICHLOROETHENE ND
IS-1 .2—DICHLOROETHENE ND
TRANS-1r2—DICHLOROETHENE ND
1r2—DICHLOROPROPANE ND
1r3—DICHLOROPROPANE ND
• r2--DICHLOROPROPANE ND
1r1—DICHLOROPROPENE ND
IS-1r3—DICHLOROPROPENE ND
TRANS—ir3—DICHLOROPROPENE ND
THYLBENZENE ND
EXACHLOROBUTADIENE ND
ISOPROPYLBENZENE ND
--ISOPROPYLTOLUENE ND .
ETHYLENE CHLORIDE ND
ETHYL T—BUTYL ETHER ND
NAPHTHALENE ND
PROPYLBENZ ENE ND
STYRENE ND
p Q 1r1 ► ir2—TETRACHLOROETHANE ND
C4 1r1r2r2—TETRACHLOROETHANE ND
TETRACHLOROETHENE ND
r� ti TOLUENE ND
�•}V 1r2r3—TRICHLOROBENZENE ND
lrZr4—TRICHLOROBENZENE ND
w 1r1r1—TRICHLOROETHANE ND
1rir2—TRICHLOROETHANE ND
TRICHLOROETHENE 4.7
TRICHLOROFLUOROMETHANE ND
1r2r3—TRICHLOROPROPANE ND
1r2r4—TRIMETHYLBENZENE ND
1r3r5—TRIMETHYLBENZENE ND
VINYL CHLORIDE ND
MrOrP—XYLENES (TOTAL) ND
.NOTE; ND = NONE DETECTED
METHOD DETECTION LIMIT IS 0.5 UG/L FOR ABOVE
COMPOUNDS.
------- * END OF REPORT a�
ORM NO.OL-6A REV.10-99