HomeMy WebLinkAboutWell Inspection 877 Foster Street Extens (2) STATE OF CONNECTICUT DEPARTMENT OF ENVIRONMENTAL PROTECTION 4D i December 4, 2000 Mr. Alphonse Ambro 877 Foster Street Extension South Windsor, CT 06074 RE: Water Sampling Results for 877 Foster Street, South Windsor, CT Dear Mr. Ambro: Enclosed please find a copy of the laboratory results for the water samples that were collected from your home on October 31, 2000. The water samples were analyzed for the presence of volatile organic compounds (VOCs). As the laboratory results indicate,trace levels of methyl t-butyl ether(MTBE) and trichloroethene were identified in the water sample. The Connecticut Department of Public Health(DPH)has established the drinking water action levels for MTBE and trichloroethene at concentrations of 70 micrograms per liter and 5 micrograms per liter,respectively. Therefore,the water at your home is potable with respect to the constituents tested. If you have any questions regarding the above,please call me at(860)-424-3782. Sincerely, ;ichael P. Senyk Environmental Analyst Permitting,Enforcement and Remediation Division cc: Robert Deptula, Sanitarian, Town of South Windsor (Printed on Recycled Paper) 79 Elm Street • Hartford, CT 06106- 5127 http://dep.state.ct.us An Equal Opportunity Employer Celebratin�Connecticut Coastalsourc�xag�nt:1980-2� I.D. ACCESSION NO. ACCOUNT NO. STATE OF CONNECTICUT Department of Public Health Division of Laboratory Services 10 Clinton St. e4gwvo P.O.Box 1689 INFORMATION Hartford,CT 06144 132SOUTH WINDSOR TELEPHONE:(860)509-8500 ALPHONSE AMBRO F 877 FOSTER ST SOUTH WINDSOR CT DEP—P.E.R.D. POTABLE WATER 79 ELM ST. 10/31/00 10/31/00 11/09/00 L HARTFORD CT 06106 w 12;00 15;27 08*20 RT 406 SAMPLING POINT; KITCHEN TAP COLLECTORS SENYK, M TITLE'. ANALYST PRIVATE WELL TREATMENT; iTE ANALYZED 11/3/00 -------------------------------------------------------- ' ANALYTICAL METHOD'. EPA METHOD 524.2 MEASUREMENT OF ORGANIC COMPOUNDS IN WATER BY CAPILLARY COLUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY. -------------------------------------------------------- :'A 524.2 7INAL RESULT'- COMPOUND QUANTITY (UG/L) ENZENE ND BROMOBENZENE ND BROMOCHLOROMETHANE ND BROMODICHLOROMETHANE ND BROMOFORM ND IRROMOMETHANE ND —BUTYLBENZENE ND EC—BUTYLBENZENE ND lij -C ERT—BUTYLBENZENE ND ARBON TETRACHLORIDE ND HLOROBENZENE ND ca HLOROETHANE ND HLOROFORM ND HLOROMETHANE ND —CHLOROTOLUENE ND —CHLOROTOLUENE ND DIBROMDCHLOROMETHANE ND 1 ,2—DIBROMO-3—CHLOROPROPANE ND 1 ,2—DIBROMOETHANE ND IBROMDMETHANE ND 1 ,2—DICHLOROBENZENE ND 1 ,3—DICHLOROBENZENE ND 1 ,4—DICHLOROBENZENE ND �'3'fDDICHLORODIFLUOROMETHANE ND 1 , 1—DICHLOROETHANE ND CONTI UED RM NO.OL-6A REV.10-99 n STATE OF CONNECTICUT • Department of Public Health Division of Laboratory Services . 10 Clinton St. P.O.Box 1689 INFORMATION Hartford,CT 06144 132SOUTH W I NDSOR TELEPHONE:(860)509-8500 ALPHONSE AMBRO 877 FOSTER ST SOUTH WINDSOR CT DEP—P.E.R.D. POTABLE WATER ,•, 79 ELM ST. 10/31/OC 10/31/00 11/09/0( L HARTFORD CT 06106 � 1''a 00 15 s 27 08:20 ••• COMMENT TEST(S) RESULT(S) 1 ,2—DICHLOROETHANE ND 1 , 1—DICHLOROETHENE ND IS-1 ,2—DICHLOROETHENE ND TRANS—I ,2—DICHLOROETHENE ND 1 ,2—DICHLOROPROPANE ND 173—DICHLOROPROPANE ND �2—DICHLOROPROPANE ND 1 , 1—DICHLOROPROPENE ND IS-1 ,3—DICHLOROPROPENE ND RANS—I ,3—DICHLOROPROPENE ND THYLBENZENE ND EXACHLOROBUTADIENE ND ISOPROPYLBENZENE ND —ISOPROPYLTOLUENE ND ETHYLENE CHLORIDE ND ETHYL T—BUTYL ETHER <0.5 NAPHTHALENE ND PROPYLBENZENE ND STYRENE ND 1 , 1 , 1 ,2—TETRACHLOROETHANE ND o �u 1 , 1 ,2,2—TETRACHLOROETHANE ND CZ TETRACHLOROETHENE ND U TOLUENE ND 1 ,2,3—TRICHLOROBENZENE ND U ' 1 ,2,4—TRICHLOROBENZENE ND Ltd' 1311311—TRICHLOROETHANE ND 1 , 1 ,2—TRICHLOROETHANE ND RICHLOROETHENE <0.5 TRICHLOROFLUOROMETHANE ND 1 ,2,3—TRICHLOROPROPANE ND 1 ,2,4—TRIMETHYLBENZENE ND 1 ,3,5—TRIMETHYLBENZENE ND VINYL CHLORIDE ND M,O,P—XYLENES (TOTAL) ND TE= ND = NONE DETECTED METHOD DETECTION LIMIT IS 0.5 UG/L FOR ABOVE COMPOUNDS. ------ * END OF REPORT ORM NO.OL-6A REV.10-99