Loading...
HomeMy WebLinkAboutWell Inspection 980 Foster Street Extens STATE OF CONNECTICUT DEPARTMENT OF ENVIRONMENTAL PROTECTION WnW December 4, 2000 Mr. Dan Savino 980 Foster Street Extension South Windsor, CT 06074 RE: Water Sampling Results for 980 Foster Street,South Windsor, CT Dear Mr. Savino: Enclosed please find a copy of the laboratory results for the water samples that were collected from your home on October 31, 2000. The water samples were analyzed for the presence of volatile organic compounds (VOCs). As the laboratory results indicate,trichloroethene was identified in your water supply at a concentration of 1.0 microgram per liter. The Connecticut Department of Public Health(DPH) has established the drinking water action level for trichloroethene at a concentration of 5 micrograms per liter. Therefore,the water supply at your home is potable with respect to the constituents tested. If you have any questions regarding the above,please call me at(860)-424-3782. Sincerely, Michael P. Senyk Environmental Analyst Permitting, Enforcement and Remediation Division cc: Robert Deptula, Sanitarian, Town of South Windsor (Printed on Recycled Paper) 79 Elm Street • Hartford, CT 06106- 5127 http://dep.state.ct.us An Equal Opportunity Employer ekbrating Connecticut Coastal Resource Management:1980-2000 G/\ • STATE OF CONNECTICUT • Department of Public Health Division of Laboratory Services 10 Clinton St. P.O.Box 1689 IN I-UHIVIA I JUN Hartford,CT 06144 132SOUTH W I NDSOR TELEPHONE:(860)509-8500 DAN SAV I NO F 980 FOSTER ST SOUTH WINDSOR CT DEP-P.E.R.D. POTABLE WATER ,•_ 79 ELM ST. 10/31/0 10/31/00 11/09/00 L HARTFORD CT 06106 -J 10:50 15:27 08:20 ORT MR= SAMPLING POINT: OUTSIDE TAP COLLECTOR: SENYKr M TITLE: ANALYST PRIVATE WELL TREATMENT: 4TE ANALYZED 11/4/00 -------------------------------......__----__---_----------- ANALYTICAL METHOD: EPA METHOD 524.2 MEASUREMENT OF ORGANIC COMPOUNDS IN WATER BY CAPILLARY COLUMN GAS CHROMATOGRAPHY/MASS SPECTROMETRY. ------_.------------------------------------------------------- ZA 524.2 INAL RESULT: COMPOUND QUANTITY (UG/L) ENZENE ND ROMOBENZENE ND ROMOCHLOROMETHANE ND ROMODICHLOROMETHANE ND ROMOFORM ND J ROMOMETHANE ND -BUTYLBENZENE ND m EC-BUTYLBENZENE ND ERT-BUTYLBENZENE ND ,-, ARBON TETRACHLORIDE ND HLOROBENZENE ND HLOROETHANE ND 4, HLOROFORM ND HLOROMETHANE ND -CHLOROTOLUENE ND -CHLOROTOLUENE ND IBROMOCHLOROMETHANE ND 1r2-DIBROMO--3-CHLOROPROPANE ND 1r2-DIBROMOETHANE ND IBROMOMETHANE ND lr2-DICHLOROBENZENE ND 1r3-DICHLOROBENZENE ND 1r4-DICHLOROBENZENE ND I CHLOROD I FLUOROMETHANE ND ttt 1 , 1-DICHLOROETHANE ND CONTINUED * * )RM NO.OL-6A REV.10-99 7 ~ STATE OF CONNECTICUT CCESSION NO. ACCOUNT NO. Department of Public Health Division of Laboratory Services r 10 Clinton St. P.O.Box 1689 INFORMATION Hartford,CT 06144 132SOUTH W I NDSOR TELEPHONE:(860)509-8500 DAN SAV I NO (- 980 FOSTER ST SOUTH WINDSOR CT DEP-P,E.R.D. POTABLE WATER 1 ••• • 79 ELM ST. 10/31/0C 10/31/00 11/09/0( (_ HARTFORD CT 06106 10.50 15.27 08.20 ,�EPORT COMMENT TEST(S) RESULT(S) 1 ,2-DICHLOROETHANE ND 1 , 1-DICHLOROETHENE ND IS--1 ,2-DICHLOROETHENE ND RANS--1,2-DICHLOROETHENE ND 1 ,2-DICHLOROPROPANE ND 1 ,3-DICHLOROPROPANE ND ,2-DICHL:OROPROPANE ND 1 , I-DICHLOROPROPENE ND IS-1 ,3-DICHLOROPROPENE ND RAMS-I ,3-DICHLOROPROPENE ND THYLBENZENE ND EXACHLOROBUTADIENE ND ISOPROPYLBENZENE ND --ISOPROPYLTOLUENE ND ETHYLENE CHLORIDE ND ETHYL T-BUTYL ETHER ND APHTHALENE ND PROPYLBENZENE ND STYRENE ND 1 , 171 ,2-TETRACHLOROETHANE ND fF• 1 ,2r2-TETRACHLOROETHANE ND CW ETRACHLOROETHENE ND TOLUENE ND 1 ,2,3-TRICHLOROBENZENE ND ti 1,2,4-TRICHLOROBENZENE ND o � 1 , 1 , 1-TRICHLOROETHANE ND 1, 1 ,2--TRICHLOROETHANE ND RICHLOROETHENE 1 .0 Q RICHLOROFLUOROMETHANE ND 1 ,2,3-TRICHLOROPROPANE ND 1 ,2,4--TRIMETHYLBENZENE ND 1 ,3,5-TRIMETHYLBENZENE ND VINYL CHLORIDE ND ,O,P-XYLENES (TOTAL) ND NOTE: ND = NONE DETECTED METHOD DETECTION LIMIT IS 0.5 UG/L FOR ABOVE COMPOUNDS. --"--'- * END OF REPORT ORM NO.OL-6A REV.10-99