Loading...
HomeMy WebLinkAboutWell Inspection 150 Felt road (7) REGroundwater & Environmental Services, Inc. 425B Hayden Station Road • Windsor, CT 06095 Tel(860)688-9023 Fax(860)688-9278 February 28,2008 Mr. Daniel Katzbek 150 Felt Road ® 5 two South Windsor, CT 06074 $py�WindGS AGENCY - Re: Potable Well Sampling Information GoE v�Tcors0s 150 Felt Road South Windsor, CT 06074 Dear Mr. Katzbek, On behalf of ExxonMobil Environmental Services Company (EMESC), Groundwater and Environmental Services (GES), ExxonMobil's consultant, would like to thank you for allowing GES to conduct sampling of your drinking water well on February 8,2008. The water sample from your well was tested for the presence of a number of volatile organic compounds found in gasoline, including methyl tertiary butyl ether (MTBE). For your information, the tests were conducted utilizing Environmental Protection Agency (EPA) approved methods and a copy of the laboratory report is enclosed. The laboratory results indicate no presence of MTBE or any other compound found in gasoline in your well water. l _ � t Jtichlgroethylene [TCE]),,a cic�xi?a� hydrocarbon.commonly used as a:so,vent,-was�eeelg� a t ate" . etrat on of 0 e44 parts per brllioqppb). The Connecticut Drinking Water Standards for this compound is 5 pp . As you know, the tests conducted on your drinking water well are part of an ongoing groundwater investigation being conducted under the direction of the Connecticut Department of the Environmental Protection (CT DEP). Please note; the sampling frequency of your well, as requested by the CT DEP, is quarterly. Therefore,the next sampling event is scheduled for May 2008. Again,thank you for your patience and cooperation. If you have any questions regarding the test results or the investigation in the area or if you notice changes in the taste, smell or appearance of your water, please feel free to call the toll free ExxonMobil Information Line at 1-877-346-0302 or, if you prefer, we suggest you contact Kevin Neary with the DEP at 860-424-3947 or Robert Deptula, the Environmental Health Officer for the Town of South Windsor,at 860-644-2511 ext.248. Sinc7el , Violin D. Moss Kar rris Project Hydrogeologist Senior Project Manager Enclosure cc: Kevin Neary-Connecticut Department of the Environmental Protection Robert Deptula Town of South Windsor C. Fredrick Shaw-Town of South Windsor Jeff Folger-Town of South Windsor Walter Summers -Fire Marshal Town of South Windsor Environmental Solutions and Liability Management e-Hardcopy 2.0 Aratorrrated.Report ® New England 12aaccu-rEsY�: - — --- __ zip - '� L_ �t � .a R�— - --— 02/1$/08 Technical Report for ExxonMobil GESCT:01-QQA 249 Oakland Rd., South Windsor CT PO#4509333735 WBS#08 Accutest Job Number: M70780 Sampling Date: 02/08/08 Report to: Groundwater & Environmental Services JMoss@gesonline.com ATTN: John Moss Total number of pages in report: 20 a�o`��v�N accoRaA�c YI _ . o • . K01�• Test results contained within this data package meet the requirements Z7a Z of the National Environmental Laboratory Accreditation Conference Lab Director and/or state specific certification programs as applicable. Client Service contact: Kristen Blanchard 508-481-6200 Certifications:MA(M-MA136) CT(PH-0109) NH(250204) RI(00071) ME(MA136) FL(E87579) Y E A R S NY(23346) NJ(MA926) NAVY USACE This report shall not be reproduced,except in its entirety,without the written approval of Accutest Laboratories. Test results relate only to samples analyzed. New England • 495 Tech Center West • Building 1 • Marlborough,MA 01752 • tel:508-481-6200 • fax:508-481-7753 • http://www.accutest.com ® 1 of 20 ©Ary_I 17=CT Sections: Table of Contents Q Section1: Sample Summary ................................................................................................... 3 Section 2: Case Narrative/Conformance Summary.............................................................. 4 Section3: Sample Results ............................................................... ..................................... 5 3. : M70780-1: 150 FELT RD ............................................................................................ 6 Section4: Misc. Forms ............................................................................................................ 8 4.1: Chain of Custody ........................................................................................................... 9 4.2: RCP Form ............................................................................................................ ...... 11 4.3: Sample Tracking Chronicle ........................................................................................... 12 Section 5: GUMS Volatiles -QC Data Summaries .............................................................. 13 5.1: Method Blank Summary ................................................................................................ 14 5.2: Blank Spike Summary ................................................................................................... 16 5.3: Duplicate Summary ....................................................................................................... 18 5A Surrogate Recovery Summaries ..................................................................................... 20 ® 2of20 - P.2 A rurq r-r==T Accutest Laboratories Sample Summary ExxonMobil Job No: M70780 GESCT:01-QQA 249 Oakland Rd., South Windsor CT Project No: PO#4509333735 WBS#08 Sample Collected Matrix Client Number Date Time By Received Code Type Sample ID M707804 02/08/08 14:14 KGA 02/11/08 DW Drinking Water 150 FELT RD ® 3 of 20 In nrrt rrccrr Ed 12 Sir. Lab o r a t o r i e s SAMPLE DELIVERY GROUP CASE NARRATIVE Client: ExxonMobil Job No M70780 Site: GESCT:01-QQA 249 Oakland Rd.,South Windsor CT Report Date 2/18/2008 10:31:54 AM 1 Sample was collected on 02/08/2008 and were received at Accutest on 02/11/2008 properly preserved,at 0.9 Deg.C and intact. These Samples received an Accutest job number of M70780.A listing of the Laboratory Sample ID,Client Sample ID and dates of collection are presented in the Results Summary Section of this report. Except as noted below,all method specified calibrations and quality control performance criteria were met for this job.For more information,please refer to QC summary pages. Volatiles by GCMS By Method EPA 524.2 REV 4.1 Matrix AQ Batch ID: MSK820 ■ All samples were analyzed within the recommended method holduig time. . All method blanks for this batch meet method specific criteria. Sample(s) M70778-1DUP were used as the QC samples indicated. ra MSK820-BS for 1,2,3-Trichlorobenzene:Outside control limits.Associated samples are non-detect for this compound. The Accutest Laboratories of New England certifies that all analysis were performed within method specification.It is further recommended that this report to be used in its entirety.The Accutest Laboratories of NE,Laboratory Director or assignee as verified by the signature on the cover page has authorized the release of this report(M70780). Monday,.February 18,2008 Page 1 of 1 ® 4 of 20 ®ar-r_i rr crr ® New England GACC _ Lai:,orxtnries - _ '-! Section Sample Results Report of Analysis ® 5 of 20 Accutest Laboratories Report of Analysis Page I of 2 Client Sample ID: 150 FELT RD Lab Sample ID: M70780-1 Date Sampled: 02/08/08 Matrix: DW-Drinking Water Date Received: 02/11/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT File ID DF Analyzed By Prep Date Prep Batch Analytical Batch Run#1 K23068.1) 1 02/13/08 RT n/a n/a MSK820 Run#2 Purge Volume Run#1 5.0 ml Run#2 VOA List CAS No. Compound Result MCL RL Units Q 71-43-2 Benzene ND 5.0 0.50 ug/1 108-86-1 Bromobenzene ND 0.50 ug/I 74-97-5 Bromochloromethane ND 0.50 ug/I 75-27-4 Bromodichloromethane ND 0.50 ug/1 75-25-2 Bromoform ND 0.50 ug/I 74-83-9 Bromomethane ND 0.50 ug/I 104-51-8 n-Butylbenzene ND 0.50 ug/1 135-98-8 sec-Butylbenzene ND' 0.50 ug/1 98-06-6 tert-Butylbenzene ND 0.50 ug/1 108-90-7 Chlorobenzene ND 100 0.50 ug/1 75-00-3 Chloroethane ND-' 0.50 ug/l 67-66-3 Chloroform ND 0.50 ug/1 74-87-3 Chloromethane ND:' 0.50 ug/1 95-49-8 o-Chlorotoluene ND 0.50 ug/1 106-43-4 p-Chlorotoluene ND 0.50 ug/1 56-23-5 Carbon tetrachloride ND 5.0 0.50 ug/I 75-34-3 1,1-Dichloroethane ND 0.50 ug/I 75-35-4 1,1-Dichloroethylene ND 7.0 0.50 ug/I 563-58-6 1,1-Dichloropropene ND 0.50 ug/1 96-12-8 1,2-Dibromo-3-chloropropane ND 0.20 0.50 ug/1 106-93-4 1,2-Dibromoethane ND 0.050 0.50 ug/I 107-06-2 1,2-Dichloroethane ND 5.0 0.50 ug/1 78-87-5 1,2-Dichloropropane ND 5.0 0.50 ug/I 142-28-9 1,3-Dichloropropane ND 0.50 ug/I 594-20-7 2,2-Dichloropropane ND 0.50 ug/I 124-48-1 Dibromochloromethane ND 0.50 ug/1 74-95-3 Dibromomethane ND 0.50 ug/1 75-71-8 Dichlorodifluoromethane ND 0.50 ug/1 10061-01-5 cis-1,3-Dichloropropane ND 0.50 ug/1 541-73-1 m-Dichlorobenzene ND 0.50 ug/l 95-50-1 o-Dichlorobenzene ND 600 0.50 ug/1 106-46-7 p-Dichlorobenzene ND 75 0.50 ug/1 ND= Not detected J= Indicates an estimated value MCL= Maximum Contamination Level (40 CFR 141) B= Indicates analyte found in associated method blank E= Indicates value exceeds calibration range N= Indicates presumptive evidence of a compound ® 6 of 20 I arrd i r=ca"s- Accutest Laboratories Report of Analysis Page 2 of 2 Client Sample ID: 150 FELT RD Lab Sample ID: M70780-1 Date Sampled: 02/08/08 Matrix: DW -Drinking Water Date Received: 02/11/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:0I-QQA 249 Oakland Rd., South Windsor CT VOA List CAS No. Compound Result MCL RL Units Q 156-60-5 trans-1,2-Dichloroethylene ND' 100 0.50 ug/I 156-59-2 cis-1,2-Dichloroethylene ND - 70 0.50 ug/I 10061-02-6 trans-1,3-Dichloropropene `ND 0.50 ug/I 100-41-4 Ethylbenzene ND 700 0.50 ug/I 87-68-3 Hexachlorobutadiene `ND 0.50 ug/I 98-82-8 isopropylbenzene ND 0.50 ug/I 99-87-6 p-Isopropyltoluene ND,_ 0.50 ug/I 75-09-2 Methylene chloride ND ` 5.0 0.50 ug/I 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/I 91-20-3 Naphthalene ND 0.50 ug/I 103-65-1 n-Propylbenzene ND 0.50 ug/I 100-42-5 Styrene ND 100 0.50 ug/I 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/I 71-55-6 1,1,1-Trichloroethane ND 200 0.50 ug/I 79-34-5 1,1,2,2-Tetrachloroethane ND 0.50 ug/I 79-00-5 1,1,2-Trichloroethane ND 5.0 0.50 ug/I 87-61-6 1,2,3-Trichlorobenzene ND 0.50 ug/I 96-18-4 1,2,3-Trichloropropane ND 0.50 ug/I 120-82-1 1,2,4-Trichlorobenzene ND: 70 0.50 ug/I 95-63-6 1,2,4-Trimethylbenzene ND 0.50 ug/I 108-67-8 1,3,5-Trimethylbenzene ND 0.50 ug/I 127-18-4 Tetrachloroethylene ND 5.0 0.50 ug/I 108-88-3 Toluene NO, 1.000 0.50 ug/I 79-01-6 Trichloroethylene 064 5.0 0.50 ug/I 75-69-4 Trichlorofluoromethane ND 0.50 ug/I 75-01-4 Vinyl chloride ND 2.0 0.50 ug/I m,p-Xylene ND 0.50 ug/I 95-47-6 o-Xylene ND 0.50 ug/I 1330-20-7 Xylenes(total) ND 10000 0.50 ug/I CAS No. Surrogate Recoveries Run#1 Run#2 Limits 2199-69-1 1,2-Dichlorobenzene-d4 77% 70-130% 460-00-4 4-Bromofluorobenzene .83% 70-130% ND= Not detected J= Indicates an estimated value MCL= Maximum Contamination Level (40 CFR 141) B= Indicates analyte found in associated method blank E= Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound ® 7 of 20 I" A.-%N-62 wwwn.n-w New England 12AC:CC_ LffU Section 4 t it find i :iTiP.S � ��,� ;£r Misc. Forms Custody Documents and Other Forms Includes the following where applicable: • Chain of Custody • RCP Form • Sample Tracking Chronicle ®® 8 of 20 x CHAIN OF .:CUSTODY w. -:495 It•CI Cenl tVea4 Wi .I MACCUTEST 1d IF MAm 2 _—__— '732.329.02M) hAX. 32.32M499/34s0 ni Jaba L.b e /t/Ja`l8� -. a,r:.n,..,r�-'i+ .....—• Nnl kcal Inforumlinn. cuenll Re Drtln In(omtalion _' t k ".,'Ni - I• FaCal Informauon +•'t` _ - _...- _�._. _ ... .- .. E' 'ONMOBIL CORPORATION-Re Tonal Laborawry Program Ndrtheast Consullanls ComWnY Nnntn Project Nwna, _ Groundwater&Environmental ServIces,Inc:-WNE Mobil-S.Windsor#01-00A ' i -.AJarasf .:- slreal .. 425 6 Ha den Station Road -249 Oakland Road cityaLite zip CITY :al 1 Winds6r':- 'Connecticut 06095 S.Windsor C F.- - _ ProJatl Canlecl: Email Esxan ..0 Contact: .John Moss-` mdb a Mary Caruso I ca Sa,ajtlyy����im E OttM b11.ConlDolPM1onap - 'Pfwrap Faap Laaaan lDp- W89p t ' -800 220-61 ex4�540. _860 fi88 9278 01.QQA. •_ - - nFlr POA .4 5cA 333735 U.. i. .--.ACCNest, - • .CuNectien-_. reserva0on IV Sadiple# FIo1d1D/Point of.Colledlon. - -_nme aM1 aiaina Imdinii - i ti'SoTel4 7 S os 141 W 3' 49 ik m r Pm •` .T around ilma(e:mxi SS Jays) - .n'Y.': :�.:s- - -a:•a'v�•.D ncwmawe mlomntum:::: •.--.:�a;:tX .rt r-_.o: t:mm�:eols;rn�.i,u> C,sla-taeuslmas Days aPo wea eY:rbn,e:' - C.nvn—lat"A" -E.FUK�-P-t - ,.�ewynusH ❑,iommaralal^e•• ..Q.ii'YApcaidgai•A'`: GA GROUNDWATER CLASSIhICAT1ON-•._-. - '�3 Day RUSH - - NJ Rd—d -�NYA P C f gory e 70ay EMERDENCY .. :. ❑NJ Fua... _a star,rorms, CT RCP STANDARDS ._Y_-- .-•—.___.. R III 6MONDENCY'- - OIIIer :.IF1�- ...:0 Co clal A R s It Clay _ i :-EMer eh T!A data available EamDleCuslodymust be do umenled beloW each time spmples Chun ae s esslcm Ind.In Courier dbl(Ypry. w — 7. ... - r. nn e, it c - at. .0 M70780: Chain of Custody Page 1 of 2 ® 9 of 20 ®Arm-1 PPRCLT lab reports missing kCP data Page 1 of 1 Kathy Revane From: Mark Warren Sent: Friday,February 15,2008 3:50 PM To: Kathy Revane Subject:FW:lab reports missing RCP data _.._._-........... --..r From:]oho Moss[mailto:]Moss@gesonline.com] Sent:Friday,February 15,2008 3:22 PM To:Mark Warren Subject:lab reports missing RCP data Mark, Here is a list of lab reports recently received without RCP details: M70778 M70779 M70786 M70785 M70780`� M70783 M70782 M70781 RCP analysis was requested in the comments section of each chain of custody. Please let me know if that data package can be included with each report. Thank you, John John D.Moss Project Hydrogeologist Groundwater and Environmental Services,Inc. 425E Hayden Station Road J Windsor,CT 06095 PH:800-220-6119 Ext.3540 FX:860-688-9278 00 jmoss@gesonline.com n Confidentiality Notice:This transmission(including any attachments)may contain confidential information belonging to Groundwater&Environmental Services,Inc.and is intended only for the use of the party or entity to which it is addressed.If you are not the intended recipient,you are hereby notified that any disclosure,copying,distribution,retention or the taking of action in reliance on the � 9 contents of this transmission is strictly prohibited.If you baee received this transmission in error,please "® try immediately notify the sender and erase all information and attachments.Thank You. o 2/1512008 t - Laboratory Analysis QA/QC Certification Form IV Laboratory Name: Accutest New England Client: ExxonMobil Q Project Location: GESCT:01-QQA 249 Oakland Rd.,South Project Number: PO#4509333735 WBS#08 Windsor CT Sampling Date(s): 2/8/2008 Laboratory Sample ID(s): M70780-1 For each analytical method referenced in this laboratory report package, were all specified QA/QC performance criteria followed(including the requirement to 1 explain any criteria falling outside of acceptable guidelines,as specified in the CT Yes No DEP method-specific Reasonable Confidence Protocol documents)? Were all samples received by the laboratory in a condition consistent with 2 that described on the associated chain-of-custody document(s)? Yes No r 3 Were samples received at an appropriate temperature(4°C t 2°)? Yes No M' Were all QA/QC performance criteria specified in the CT DEP Reasonable 4 Confidence Protocol documents achieved? Yes No 5 a)Were reporting limits specified or referenced on the chain-of-custody? Yes No IM b)Were these reporting limits met? Yes C No For each analytical method referenced in this laboratory report package, 6 were results reported for all constituents identified in the method-specific Yes Mn No analyte lists presented in the Reasonable Confidence Protocol documents? Are project-specific matrix spikes and laboratory duplicates included in this 7 data set? Yes No Note: For all questions to which the response was"No" (with the exception of question#7),additional information must be provided in an attached narrative. If the answer to question#1 is "No",the data package does not meet the requirements for"Reasonable Confidence". I,the undersigned,attest under pains and penalties of perjury that,to the best of my knowledge and belief and based upon my personal inquiry of those responsible for providing the information contained in this analytical report,such information is accurate and complete. Authorized Signature: Position: Lab Director Printed Name: Reza Tand Date: 2/18/2008 ® 11 of 20 Accutest Laboratories Internal Sample Tracking Chronicle w ExxonMobil Job No: M70780 GESCT:01-QQA 249 Oakland Rd., South Windsor CT Project No: PO#4509333735 WBS#08 Sample Number Method Analyzed By Prepped By Test Codes 474 M70780-1 EPA 524.2 REV 4.1 13-FEB-08 17:01 RT V524STD Page 1 of 1 ® 12 of 20 New England ®ACX Section 5 GUMS Volatiles QC Data Summaries Includes the following where applicable: • Method Blank Summaries • Blank Spike Summaries • Matrix Spike and Duplicate Summaries • Surrogate Recovery Summaries ® 13 of 20 Method Blank Summary Page 1 of 2 Job Number: M70780 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-MB K23054.13 1 02/13/08 RT n/a n/a MSK820 ur 3 The C reported here applies to the following samples: Method: EPA 524.2 REV 4.1 Q P PP g P M70780-1 CAS No. Compound Result RL Units Q 71-43-2 Benzene ND 0.50 ug/l 108-86-1 Bromobenzene ND 0.50 ug/l 74-97-5 Bromochloromethane ND -' 0.50 ug/l 75-27-4 Bromodichloromethane ND 0.50 ug/l 75-25-2 Bromoform ND 0.50 ug/1 74-83-9 Bromomethane ND_ __ 0.50 ug/l 104-51-8 n-Butylbenzene ND 0.50 ug/l 135-98-8 sec-Butylbenzene ND 0.50 ug/l 98-06-6 tert-Butylbenzene ND 0.50 ug/l 108-90-7 Chlorobenzene Nb 0.50 ug/l 75-00-3 Chloroethane ND 0.50 ug/l 67-66-3 Chloroform N_D 0.50 ug/l 74-87-3 Chloromethane ND 0.50 ug/l 95-49-8 o-Chlorotoluene ND 0.50 ug/l 106-43-4 p-Chlorotoluene ND 0.50 ug/l 56-23-5 Carbon tetrachloride ND 0.50 ug/l 75-34-3 1,1-Dichloroethane ND 0.50 ug/l 75-35-4 1,1-Dichloroethylene ND 0.50 ug/l 563-58-6 1,1-Dichloropropene ND 0.50 ug/l 96-12-8 1,2-Dibromo-3-chloropropane ND 0.50 ug/l 106-93-4 1,2-Dibromoethane ND 0.50 ug/l 107-06-2 1,2-Dichloroethane ND 0.50 ug/l 78-87-5 1,2-Dichloropropane ND 0.50 ug/l 142-28-9 1,3-Dichloropropane ND 0.50 ug/l 594-20-7 2,2-Dichloropropane ND 0.50 ug/l 124-48-1 Dibromochloromethane ND 0.50 ug/l 74-95-3 Dibromomethane ND 0.50 ug/l 75-71-8 Dichlorodifluoromethane ND 0.50 ug/l 10061-01-5 cis-1,3-Dichloropropene ND 0.50 ug/l 541-73-1 m-Dichlorobenzene ND 0.50 ug/l 95-50-1 o-Dichlorobenzene ND 0.50 ug/l 106-46-7 p-Dichlorobenzene ND 0.50 ug/l 156-60-5 trans-1,2-Dichloroethylene ND 0.50 ug/l 156-59-2 cis-1,2-Dichloroethylene ND 0.50 ug/l 10061-02-6 trans-1,3-Dichloropropene ND 0.50 ug/l 100-41-4 Ethylbenzene ND 0.50 ug/l ® 14 of 20 Method Blank Summary Page 2 of 2 Job Number: M70780 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-MB K23054.D 1 02/13/08 RT n/a n/a MSK820 cn i The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 P M70780-1 CAS No. Compound Result RL Units Q 87-68-3 Hexachlorobutadiene NO. _ 0.50 ug/I 98-82-8 Isopropylbenzene ND 0.50 ug/I 99-87-6 p-Isopropyltoluene ND 0.50 ug/I 75-09-2 Methylene chloride ND 0.50 ug/I 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/I 91-20-3 Naphthalene NO 0.50 ug/I 103-65-1 n-Propylbenzene Np 0.50 ug/I 100-42-5 Styrene NO 0.50 ug/I 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/I 71-55-6 1,1,1-Trichloroethane NO 0.50 ug/I 79-34-5 1,1,2,2-Tetrachloroethane NO 0.50 ug/I 79-00-5 1,1,2-Trichloroethane NO 0.50 ug/I 87-61-6 1,2,3-Trichlorobenzene NO . 0.50 ug/I 96-18-4 1,2,3-Trichloropropane ND,;...^ 0.50 ug/I 120-82-1 1,2,4-Trichlorobenzene N13. `'0.50 ug/l 95-63-6 1,2,4-Trimethylbenzene NO 0.50 ug/l 108-67-8 1,3,5-Trimethylbenzene NO 0.50 ug/I 127-18-4 Tetrachloroethylene ND 0.50 ug/I 108-88-3 Toluene NO = 0.50 ug/I 79-01-6 Trichloroethylene NO 0.50 ug/I 75-69-4 Trichlorofluoromethane NO 0.50 ug/I 75-01-4 Vinyl chloride NO 0.50 ug/I m,p-Xylene NO 0.50 ug/l 95-47-6 o-Xylene NO 0.50 ug/I 1330-20-7 Xylenes(total) NO 0.50 ug/l CAS No. Surrogate Recoveries Limits 2199-69-1 1,2-Dichlorobenzene-d4 79% 70-130% 460-00-4 4-Bromofluorobenzene 92% 70-130% ® 15 of 20 Blank Spike Summary Page I of 2 Job Number: M70780 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-BS K23052.13 1 02/13/08 RT n/a n/a MSK820 trs iv The C reported here applies to the following samples: Method: EPA 524.2 REV 4.1 Q P PP g P M70780-1 Spike BSP BSP CAS No. Compound ug/l ug/l % Limits 71-43-2 Benzene 5 4.7 94 70-130 108-86-1 Bromobenzene 5 4.9 98; 70-130 74-97-5 Bromochloromethane 5 4.9 98 70-130 75-27-4 Bromodichloromethane 5 4.9 .08: 70-130 75-25-2 Bromoform 5 4.9 98, 70-130 74-83-9 Bromomethane 5 5.0 100 70-130 104-51-8 n-Butylbenzene 5 4.9 98 70-130 135-98-8 sec-Butylbenzene 5 4.9 9.8` 70-130 98-06-6 tert-Butylbenzene 5 4.9 A 70-130 108-90-7 Chlorobenzene 5 4.8 =96 ' 70-130 75-00-3 Chloroethane 5 4.8 96. 70-130 67-66-3 Chloroform 5 4.9 98" 70-130 74-87-3 Chloromethane 5 5.0 100 70-130 95-49-8 o-Chlorotoluene 5 4.8 96' 70-130 106-43-4 p-Chlorotoluene 5 4.9 98 70-130 56-23-5 Carbon tetrachloride 5 4.9 98 70-130 75-34-3 1,1-Dichloroethane 5 5.0 160 70-130 75-35-4 1,1-Dichloroethylene 5 5.2 104 70-130 563-58-6 1,l-Dichloropropene 5 4.8 96 70-130 96-12-8 1,2-Dibromo-3-chloropropane 5 5.2 104 70-130 106-93-4 1,2-Dibromoethane 5 4.9 98 70-130 107-06-2 1,2-Dichloroethane 5 5.0 100 70-130 78-87-5 1,2-Dichloropropane 5 4.8 96 70-130 142-28-9 .1,3-Dichloropropane 5 4.5 90 70-130 594-20-7 2,2-Dichloropropane 5 4.6 92 70-130 124-48-1 Dibromochloromethane 5 4.9 98 70-130 74-95-3 Dibromomethane 5 5.1 102 707130 75-71-8 Dichlorodifluoromethane 5 3.6 72 70-130 10061-01-5 cis-1,3-Dich loropropene 5 4.8 96 70-130 541-73-1 m-Dichlorobenzene 5 4.9 98 70-130 95-50-1 o-Dichlorobenzene 5 5.1 102 70-130 106-46-7 p-Dichlorobenzene 5 5.2 104 70-130 156-60-5 trans-1,2-Dichloroethylene 5 4.6 92 70-130 156-59-2 cis-1,2-Dichloroethylene 5 4.5 90 70-130 10061-02-6 trans-1,3-Dichloropropene 5 5.2 104 70-130 100-41-4 Ethylbenzene 5 4.8 96 70-130 ® 16 of 20 !�wr+re rr�c�r a K Blank Spike Summary Page 2 of 2 Job Number: M70780 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-BS K23052.D 1 02/13/08 RT n/a n/a MSK820 en i+a The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70780-1 Spike BSP BSP CAS No. Compound ug/1 ug/l % Limits 87-68-3 Hexachlorobutadiene 5 5.4 108 70-130 98-82-8 Isopropylbenzene 5 4.9 98 70-130 99-87-6 p-Isopropyltoluene 5 5.0 100 70-130 75-09-2 Methylene chloride 5 4.6 92 70-130 1634-04-4 Methyl Tert Butyl Ether 5 5.1 102 70-130 91-20-3 Naphthalene 5 5.5 110 70-130 103-65-1 n-Propylbenzene 5 4.9 98 70-130 100-42-5 Styrene 5 4.7 94 70-130 630-20-6 1,1,1,2-Tetrachloroethane 5 4.8 96 70-130 71-5576 1,1,1-Trichloroethane 5 4.7 94 : 70-130 79-34-5 1,1,2,2-Tetrachloroethane 5 5.1 102 70-130 79-00-5 1,1,2-Trichloroethane 5 4.9 98 70-130 87-61-6 1,2,3-Trichlorobenzene 5 6.6 132*a 70-130 96-18-4 1,2,3-Trichloropropane 5 4.7 94_ 70-130 120-82-1 1,2,4-Trichlorobenzene 5 5.2 104 70-130 95-63-6 1,2,4-Trimethylbenzene 5 4.8 96 70-130 108-67-8 1,3,5-Trimethylbenzene 5 4.9 98 70-130 127-18-4 Tetrachloroethylene 5 4.9 98 70-130 108-88-3 Toluene 5 4.8 96 70-130 79-01-6 Trichloroethylene 5 4.6 92 70-130 75-69-4 Trichlorofluoromethane 5 4.8 96 70-130 75-01-4 Vinyl chloride 5 4.7 94 70-130 m,p-Xylene 10 9.5 95 70-130 95-47-6 o-Xylene 5 4.9 98 70-130 1330-20-7 Xylenes(total) 15 14.4 96 70-130 CAS No. Surrogate Recoveries BSP Limits 2199-69-1 1,2-Dichlorobenzene-d4 107% 70-130% 460-00-4 4-Bromofluorobenzene 102% 70-130% (a)Outside control limits. Associated samples are non-detect for this compound. all 17 of 20 w3,ft r% %l wr=CwV- Duplicate Summary Page 1 of 2 Job Number: M70780 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch M70778-1DUP K23066.D 1 02/13/08 RT n/a n/a MSK820 M70778-1 K23065.D 1 02/13/08 RT n/a n/a MSK820 'ta The C reported here applies to the following samples: Method: EPA 524.2 REV 4.1 Q P PP g P M70780-1 M70778-1 DUP CAS No. Compound ug/I Q ug/1 Q RPD Limits 71-43-2 Benzene ND ND ne 30 108-86-1 Bromobenzene ND ND nc 30 74-97-5 Bromochloromethane ND ND nc 30 75-27-4 Bromodichloromethane ND ND nd '' 30 75-25-2 Bromoform ND ND ne 30 74-83-9 Bromomethane ND ND nc 30 104-51-8 n-Butylbenzene ND ND ne '" 30 135-98-8 sec-Butylbenzene ND ND nc 30 98-06-6 tert-Butyl benzene ND ND nc : 30 108-90-7 Chlorobenzene ND ND nc 30 75-00-3 Chloroethane ND ND ne 30 67-66-3 Chloroform ND ND nc 30 74-87-3 Chloromethane ND ND nc__ 30 95-49-8 o-Chlorotoluene ND ND nc 30 106-43-4 p-Chlorotoluene ND ND nc 30 56-23-5 Carbon tetrachloride ND ND ne 30 75-34-3 1,1-Dichloroethane ND ND nc 30 75-35-4 1,1-Dichloroethylene ND ND nc 30 563-58-6 1,1-Dichloropropene ND ND ne 30 96-12-8 1,2-Dibromo-3-chloropropane ND ND nc. 30 106-93-4 1,2-Dibromoethane ND ND nc 30 107-06-2 1,2-Dichloroethane ND ND ne 30 78-87-5 1,2-Dichloropropane 0.28 0.25 J 11 30 142-28-9 1,3-Dichloropropane ND ND ne 30 594-20-7 2,2-Dichloropropane ND ND nc 30 124-48-1 Dibromochloromethane ND ND nc 30 74-95-3 Dibromomethane ND ND nc 30 75-71-8 Dichlorodifluoromethane ND ND ne 30 10061-01-5 cis-1,3-Dichloropropene ND ND nc 30 541-73-1 m-Dichlorobenzene ND ND ne 30 95-50-1 o-Dichlorobenzene ND ND ne 30 106-46-7 p-Dichlorobenzene ND ND nc 30 156-60-5 trans-1,2-Dichloroethylene ND ND nc 30 156-59-2 cis-1,2-Dichloroethylene ND ND nc 30 10061-02-6 trans-1,3-Dichloropropene ND ND nc 30 100-41-4 Ethylbenzene ND ND nc 30 18of20 Duplicate Summary Page 2 of 2 Job Number: M70780 . Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed° By Prep Date Prep Batch Analytical Batch M70778-1DUP K23066.1) 1 02/13/08 RT n/a n/a MSK820 M70778-1 K23065.1) 1 02/13/08 RT n/a n/a MSK820 , w The QC reported here applies to the following samples: Method: EPA 524.2REV4.1 M70780-1 M70778-1 DUP CAS No. Compound ug/1 Q ug/1 Q RPD Limits 87-68-3 Hexachlorobutadiene ND ND nc 30 98-82-8 Isopropylbenzene ND ND nc 30 99-87-6 p-Isopropyltoluene ND ND nc 30 75-09-2 Methylene chloride ND ND nc 30 1634-04-4 Methyl Tert Butyl Ether ND ND nc 30 91-20-3 Naphthalene ND ND nc 30 103-65-1 n-Propylbenzene ND ND nc 30 100-42-5 Styrene ND ND nc 30 630-20-6 1,1,1,2-Tetrachloroethane ND ND nc 30 71-55-6 1,1,1-Trichloroethane ND ND nc 30 79-34-5 1,1,2,2-Tetrachloroethane ND ND nc 30 79-00-5 1,1,2-Trichloroethane ND ND nc 30 87-61-6 1,2,3-Trichlorobenzene ND ND nc 30 96-18-4 1,2,3-Trichloropropane ND ND nc 30 120-82-1 1,2,4-Trichlorobenzene ND ND nc 30 95-63-6 1,2,4-Trimethylbenzene ND ND nc,,,.,; 30 108-67-8 1,3,5-Trimethylbenzene ND ND nc`;- 30 127-18-4 Tetrachloroethylene ND ND nc 30 108-88-3 Toluene ND ND nc 30 79-01-6 Trichloroethylene 1.2 1.2 0 30 75-69-4 Trichlorofluoromethane ND ND nc-"`` 30 75-01-4 Vinyl chloride ND ND nc 30 m,p-Xylene ND ND nc- 30 95-47-6 o-Xylene ND ND nc 30 1330-20-7 Xylenes(total) ND ND nc. 30 CAS No. Surrogate Recoveries DUP M70778-1 Limits 2199-69-1 1,2-Dichlorobenzene-d4 84% 78% 70-130% 460-00-4 4-Bromofluorobenzene 85% 860A 70-130% ® 19 of 20 W2...+.+. r rcgmr Volatile Surrogate Recovery Summary Page I of I Job Number: M70780 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Method: EPA 524.2 REV 4.1 Matrix: AQ Samples and QC shown here apply to the above method M :a. Lab Lab Sample ID File ID S1 S2 M70780-1 K23068.D 77.0 83.0 M70778-IDUP K23066.D 84.0.. 85.0 MSK820-BS K23052.13 107.0 102.0 MSK820-MB K23054.13 790 92.0 Surrogate Recovery Compounds Limits S1 = 1,2-Dichlorobenzene-d4 70-130%0 S2= 4-Bromofluorobenzene -70-130%0:' ® 20 of 20 F2Arm-i rr==-r