HomeMy WebLinkAboutWell Inspection 82 Felt Road (15) A S r. � Groundwater IM50 & Environmental Services, Inc. 425B Hayden Station Road a Windsor,CT 06095 • Tel(860)688-9023 • Fax(860)688-9278 February 28,2008 Mr. Richard Burrill Wapping Shopping Center,LLC 52 Tallwood Drive South Windsor, CT 06074 Re: Potable Well Sampling Information 291C and 291D Oakland Road(also known as 287C and 297DC, respectively) South Windsor, CT 06074 Dear Mr. Burrill, On behalf of ExxonMobil Environmental Services Company (EMESC), Groundwater and Environmental Services (GES), ExxonMobil's consultant, would like to thank you for allowing GES to conduct sampling of your drinking water wells on February 8,2008. The water samples from your wells were tested for the presence of a number of volatile organic compounds found in gasoline, including methyl tertiary butyl ether (MTBE). For your information, the tests were conducted utilizing Environmental Protection Agency (EPA) approved methods and a copy of the laboratory report is enclosed. The laboratory results indicate no presence of MTBE or any other compound found in gasoline in your well water. As you know, the tests conducted on your drinking water well are part of an ongoing groundwater investigation being conducted under the direction of the Connecticut Department of the Environmental Protection (CT DEP). Please note; the sampling frequency of your well, as requested by the CT DEP, is quarterly. Therefore,the next sampling event is scheduled for May 2008. Again,thank you for your patience and cooperation. If you have any questions regarding the test results or the investigation in the area or if you notice changes in the taste, smell or appearance of your water, please feel free to call the toll free ExxonMobil Information Line at 1-877-346-0302 or, if you prefer, we suggest you contact Kevin Neary with the DEP at 860-424-3947 or Robert Deptula, the Environmental Health Officer for the Town of South Windsor, at 860-644-2511 ext. 248. Sincerely J-hn D. Moss aren L. Harris Project Hydrogeologist Senior Project Manager Enclosure cc: Kevin Neary-Connecticut Department of the Environmental Protection Robert Deptula-Town of South Windsor C.Fredrick Shaw-Town of South Windsor Jeff Folger-Town of South Windsor Walter Summers-Fire Marshal Town of South Windsor FnvirnnmPnta!Sntutions and i iability MananPmant r �. e-Harrlcopy 2.0 Autonnated Report ® New England ,tortes — Oi/i U8 Technical Report for ---------------- ExxonMobil GESCT:01-QQA Z49 Oakland Rd., South Windsor CT PO#4509333735 WBS#08 Accutest Job Number: M7078Z Sampling Date: OZ/08/08 Report to: Groundwater& Environmental Services JMoss@gesonline.com ATTN: John Moss Total number of pages in report: 20 V.,µ AC C044) moo` O� e x Reza and , ,e • � Lei" Test results contained within this data package meet the requirements Lab Director of the National Environmental Laboratory Accreditation Conference and/or state specific certification programs as applicable. Client Service contact: Kristen Blanchard 508-481-6200 Certifications:MA(M-MA136) CT(PH-0109) NH(250204) Rl(00071) ME(MA136) FL(E87579) Y E A R S NY(23346) NJ (MA926) NAVY USACE without the written approval of Accutest Laboratories. This report shall not be reproduced,except in its entirety, a . Test results relate only to samples analyzed. ®• Marlborough,MA 01752 tel:508 481-G200 • fax:508-481-7753 httip-//www.accutest.com ute�co 1 of 20 New England 495 Tech Center West • Building 1 uTEST M70782 T-.,. ".:, T- Sections: Table of Contents Section1• Sample Summary................................................................................................... 3 Section2: Case Narrative/Conformance Summary .............................................................. 4 Section3: Semple Results ............................... ........................................................................ 5 3.1: M70782-1: 291 C OAKLAND RD ............................................................................... 6 Section4: Misc. Forms ............................................................................................................ 8 4.1: Chain of Custody ........................................................................................................... 9 4.2: RCP Form ...................................................................................................................... 11 4.3: Sample Tracking Chronicle ........................................................................................... 12 Section 5: CC/MS Volatiles -QC Data Summaries .............................................................. 13 5.1: Method Blank Summary ................................................................................................ 14 5.2: Blank Spike Summary ................................................................................................... 16 5.3: Duplicate Summary ....................................................................................................... 18 5.4: Surrogate Recovery Summaries ..................................................................................... 20 ® 2 of 20 12A.cc_ UTEsr. i 5 Accutest Laboratories Sample Summary ExxonMobil Job No: M70782 GESCT:01-QQA 249 Oakland Rd., So th Windsor CT Project No: PO#4509333735 Client Matrix Sample ID Sample Collected Received Code Type Number Date Time By 291C gAKLAND RD M70782-I_; 02/08l0 g 13:20 KGA 02/11/08 DW Drinking Water ® 3 of 20 M70782 ` "'"' ®AA LMES Lab o i- a t o r i es SAMPLE DELIVERY GROUP CASE NARRATIVE Client: ExxonMobil Job No M70782 Site: GESCT:01-QQA 249 Oakland Rd.,South Whidsor CT Report Date 2/18/2008 10:21:52 AM 1 Sample was collected on 02/08/2008 and were received at Accutest on 02/11/2008 properly preserved,at 0.9 Deg.C and intact. These Samples received an Accutest job number of M70782.A listing of the Laboratory Sample ID,Client Sample ID and dates of collection are presented in the Results Summary Section of this report. Except as noted below,all method specified calibrations and quality control performance criteria were met for this job.For more information,please refer to QC summary pages. Volatiles by GCMS By Method EPA 524.2 REV 4.1 Matrix AQ Batch ID: MSK820 0 All samples were analyzed within the recommended method holding time. All method blanks for this batch meet method specific criteria. Sample(s) M70778-1DUP were used as the QC samples indicated. W MSK820-BS for 1,2,3-Trichlorobenzene:Outside control limits.Associated samples are non-detect for this compound. The Accutest Laboratories of New England certifies that all analysis were performed within method specification.It is further recommended that this report to be used in its entirety.The Accutest Laboratories of NE,Laboratory Director or assignee as verified by the signature on the cover page has authorized the release of this report(M70782). Monday,February 18,2008 Page 1 of I n 4 of 20 ®ACCUTEST MM79') :-..n.,.o..r.. New England Se :an 3 �A m -- — ----= ---- -- Sample Results Report of Analysis 5of20 ®ACCtJ'TUST' F Accutest Laboratories Report of Analysis Page I of 2 Client Sample ID: 291 C OAKLAND RD Lab Sample ID: M70782-1 Date Sampled: 02/08/08 Matrix: DW-Drinking Water Date Received: 02/11/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT File ID DF Analyzed By Prep Date Prep Batch Analytical Batch Run#1 K23070.1) 1 02/13/08 RT n/a n/a MSK820 Run#2 Purge Volume Run#1 5.0 ml Run#2 VOA List CAS No. Compound Result MCL RL Units Q 71-43-2 Benzene ND 5.0 0.50 ug/l 108-86-1 Bromobenzene ND 0.50 ug/1 74-97-5 Bromochloromethane ND 0.50 ug/1 75-27-4 Bromodichloromethane ND 0.50 ug/I 75-25-2 Bromoform ND 0.50 ug/1 74-83-9 Bromomethane ND 0.50 ug/1 104-51-8 n-Butylbenzene ND 0.50 ug/1 135-98-8 sec-Butylbenzene ND : 0.50 ug/I 98-06-6 tert-Butylbenzene ND 0.50 ug/I 108-90-7 Chlorobenzene ND 100 0.50 ug/l 75-00-3 Chloroethane ND ' 0.50 ug/1 67-66-3 Chloroform ND 0.50 ug/l 74-87-3 Chloromethane ND 0.50 ug/1 95-49-8 o-Chlorotoluene ND 0.50 ug/I 106-43-4 p-Chlorotoluene ND 0.50 ug/1 56-23-5 Carbon tetrachloride ND 5.0 0.50 ug/l 75-34-3 1,1-Dichloroethane ND 0.50 ug/1 75-35-4 1,1-Dichloroethylene ND 7.0 0.50 ug/I 563-58-6 1,1-Dichloropropene ND 0.50 ug/l 96-12-8 1,2-Dibromo-3-chloropropane ND 0.20 0.50 ug/I 106-93-4 1,2-Dibromoethane ND 0.050 0.50 ug/l 107-06-2 1,2-Dichloroethane ND 5.0 0.50 ug/l 78-87-5 1,2-Dichloropropane ND 5.0 0.50 ug/1 142-28-9 1,3-Dichloropropane ND 0.50 ug/1 594-20-7 2,2-Dichloropropane ND 0.50 ug/l 124-48-1 Dibromochloromethane ND 0.50 ug/I 74-95-3 Dibromomethane ND 0.50 ug/1 75-71-8 Dichlorodifluoromethane ND 0.50 ug/1 10061-01-5 cis-1,3-Dichloropropene ND 0.50 ug/l 541-73-1 m-Dichlorobenzene ND 0.50 ug/I 95-50-1 o-Dichlorobenzene ND 600 0.50 ug/l 106-46-7 p-Dichlorobenzene ND 75 0.50 ug/1 ND= Not detected J= Indicates an estimated value MCL= Maximum Contamination Level (40 CFR 141) B= Indicates analyte found in associated method blank E= Indicates value exceeds calibration range N= Indicates presumptive evidence of a compound 6 of 20 ®ACCLrMlST _ spa Accutest Laboratories page 2 of 2 :A Report of Analysis Client Sample ID: 291C OAKLAND RD Date Sampled: 02/08/08 Lab le ID: M70782-1 Date Received: 02/11/08 Matrix:x: DW -Drinking Water percent Solids: n/a Method: EPA 524.2 REV 4.1 Project: GESCT:O1-QQA 249 Oakland Rd., South Windsor CT VOA List CAS No. Compound Result MCL RL Units Q s-1,2-Dichloroethylene ND 100 0.50 ug/l 156-60-5 tran 70 0.50 ug/I 156-59-2 cis-1,2-Dichloroethylene ND ND 0.50 ug/I 10061-02-6 trans-1,3-Dichloropropene ND 700 0.50 ug/l 100-41-4 Ethylbenzene ND 0.50 ugh 87-68-3 Hexachlorobutadiene ND 0.50 ug/I 9g-82-8 Isopropylbenzene ND 0.50 ug/I 99-87-6 p-Isopropyltoluene ND 5.0 0.50 ug/I 75-09-2 Methylene chloride 0.50 ug/I 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/I 91-20-3 Naphthalene ND 0.50 ug/I 103-65-1 n-Propylbenzene ND 100 0.50 ug/l 100-42-5 Styrene ND 0.50 ug/I 630-20-6 1,1,1,2-Tetrachloroethane ND 200 0.50 ug/I 71-55-6 1,1,1-Trichloroethane 0.50 ug/I 79-34-5 1,1,2,2-Tetrachloroethane ND ND 5.0 0.50 ug/I 79-00-5 1,1,2-Trichloroethane 0.50 ug/l 87-61-6 1,2,3-Trichlorobenzene ND ND 0.50 ug/I 96-18-4 1,2,3-Trichloropropane 70 0.50 ug/l 120-82-1 1,2,4-Trichlorobenzene ND ND 0.50 ug/I 95-63-6 1,2,4-Trimethylbenzene 0.50 ug/l 108-67-8 1,3,5-Trimethylbenzene ND ND 5.0 0.50 ug/l 127-19-4 Tetrachloroethylene ND 00 0.50 ug/I 108-88-3 Toluene ND 5.0 0.50 ug/1 79-01-6 Trichloroethylene ND 0.50 1 75-69-4 Trichlorofluoromethane ND 2.0 0.50 ug/l 75-01-4 Vinyl chloride NO 0.50 ug/I rn,p-Xylene ND 0.50 ug/I 95-47-6 o-Xylene ND 10000 0.50 ug/l 1330-20-7 Xylenes(total) Run#1 Run#2 Limits CAS No. Surrogate Recoveries . 78% 70-130% 2199-69-1 1,2-Dichlorobenzene-d4 92% 70-130% 460-00-4 4-Bromofluorobenzene J= Indicates an estimated value B= Indicates analyte found in associated method blank ND= Not detected N = Indicates presumptive evidence of a compound MCL= Maximum Contamination Level (40 CFR l41) E= Indicates value exceeds calibration range 7 of 20 New England AWOL %ftop 12a►ccusT Section 4 } Misc. Forms Custody Documents and Other Forms Includes the following where applicable; • Chain of Custody • RCP Form • Sample Tracking Chronicle ® 8 of 20 4 _ _ OIt CI1STOi--�Y ,--------__-•--- - CHAIN r�7o782 --- .+ 495'(cah Ccnlerw s601d*.1 n - -- A'tA11175� M1I 9.34991"".11 Marlboro, ;T o.33 ` __..�--' •��,.... . � L,j'T�sJ'T •nza_Lnzlw rr I � i;ACC L n r,r F n, . paca l Inlamalnn - `� i ' ... - Pro ram Northeast Clienll(ta din Intom+alion Tonal Laborato 710N Ra PratoctNama: ; O(ONMOBILCORPORA Wlnds0i'01-o0A Mobil-S. ,- I Amms c""""Y"I", oma shoal -- 2qg Oakland Road s+a Joundwater&Envlronmenlal Services Ina•W NE act city - I 125 6 Ha den Station Road vP g,Windsor stau l 06095 ExxonM"bx Gonlacl: -•'I Connceclicu a.man Me Caruso - �IndSpf lael Phonam M. iStyilU5.50Al PuxanMobll Cpn - .. Jactconatl: 'rana;5' Was# - . John Use "'-� •� 1 .Plan o . � pw s"oadwrlo , OA Litt.s _ .3 Fars `ll s 960 660.9278 Prom N60933373 ricc----7 a 80o 220-6119 ex1.35'10 6.i1 _ -.._..�... FEs CoiWHion sol S 1`I Sen s Mntdx � ._ . - it Sam13e N Fisitl N 1 Point of Coxection //;; j' _-�,�- oataoctvaaNa^ - NDWATERCLASSI 1cCATfQ7d_--- GA G! SPCa app paYa O f'. ''� Q Gommarclai"A" t.r d Tana 0a5MtC5s Ja'1 " ❑N • TUmar""" lag"ryA � _ �--�-� Mds""W"t - ❑ RCP STANDARDS Cammarclal"e" ❑ ._._--�� L=---+aid.to sdstrwcc N sP ram9orya CT I�s pat NOSH j NJ aaducsd ❑5 to winos - LL.--�•--'' �NJ F. �spaYRUSH ,"yam ERGENCY ---�_�- Olsa t'-I2paY ENEnGENCY --- LOP arcial it wly V' .si!`..c.,ve.:.Y �-1 1 pat ENERGENCY �_ F• _- '"yN "SSCSSFon.in .➢.�Y%..�3 Y: �/\1•V /l.`'. ��--•-� than d la-��-•u��,a X-- I�JO1M` vaEabie'AALa0 n1 dlaaluwaach lime.@-I's• -TIA data a must ba dolt./+ Y w .a':,rK o Emer an SarrtPtt C,,-dy s `'-.1O' t 7l Slv 3 I 6 - I7p7$2: C11ain Of Custody page I Of 2 ism Lrrr-osT lab reports missing RCP data Page 1 of I Kathy Revane From: Mark Warren Sent: Friday,February 15,2008 3:50 PM To: Kathy Revane Subject:FW:lab reports missing RCP data From:John Moss fmailto:JMoss@gesonline.com] Sent:Friday,February 15,2008 3:22 PM To:Mark Warren Subject:lab reports missing RCP data Mark, Here is a list of lab reports recently received without RCP details: M70778 M70779 M70786 M70785 M70780 M70784 M70783 M70782✓.. M70781 RCP analysis was requested in the comments section of each chain of custody. Please let me know if that data package can be included with each report. Thank you, John John D.Moss Project Hydrogeologist Groundwater and Environmental Services,Inc. 425E Hayden Station Road Windsor,CT 06095 -3 PH:800-220-6119 Ext.3540 G7 J FX:860-688-9278 N jmoss@gesonline.com Confidentiality Notice:This transmission(including any attachments)may contain confidential information belonging to Groundwater&Environmental Services,Inc.and is intended only for the use of the party or entity to which it is addressed.If you are not the intended recipient,you are hereby notified that any disclosure,copying,distribution,retention or the taking of action in reliance on the contents of this transmission is strictly prohibited.If you have received this transmission in error,please n immediately notify the sender and erase all information and attachments.Thank You.®® Q� to rr C7 tJ 2:115/2008 , Laboratory Analysis N QAIQC Certification Form client: ExxonMobil Laboratory Name: Accutest New England GESCT:01 aQ A 249 Oakland Rd.,South Project Number: PO#4509333735 WBS#0 Project Location: Windsor CT Sampling Date(s): 218/2008 M70782-1 Laboratory Sample ID(s)• report package, were all the requirement to No For each analytic method referenced in this laboratory pas specified in the CT Yes QC performance criteria foilo guldel es, specified QAI p outside of acceptable 1 explain any criteria falling DEP method-specific Reasonable Confidence Protocol 1-51 documents)? Yes No the laboratory.in a condition consistent With samples received by document(s)? Were all Samp No 2 .Yes that described on the associated chain-of-custoe� ture(4°C t 2°)? les received at an appropriate temp Yes ri,- No 3 Were Samp Reasonable erformance criteria specified in the CT DEP. Were all QA/aC p Yes , No 4 Confidence Protocol documents achieved? ecified or referenced on the chain-of-custody? f 5 a)Were reporting limits sp Yes �' No M'`_ b)Were these reporting limits met? t report package, Yes No For each analytical method referenced in this laboratory ecific were results reported for th constituents e Reasonable Cotified in the me nfidence Protocol documents? 6 e lists presented in 1.2 analyt Yes � No Are project sp ecific matrix spikes and laboratory duplicates included in this 7 data set? exception of question#7),additional with the excep the data Note:For all questions to which the response was"N° ( sWer to question#1 is"No -ra ed al pac mation must be provided i aments for"Reasonable Conf dence' . package does not meet the require that,to the best of my knowledge and belief I,the undersig personal ains and penalties of perjury roviding the information contained in this ned,attest under p onsible for p and based upon my p inquiry of those resp analytical report,such information is accurate and complete. Position: Lab Director Authorized 2/18/2008 Signature: =ezaTan Date: Printed Name: i1 of 20 Accutest Laboratories Internal Sample Tracking Chronicle w ExxonMobil Job No: M70782 GESCT:01-QQA 249 Oakland Rd., South Windsor CT Project No: PO#4509333735 WBS#08 Sample Number Method Analyzed By Prepped By Test Codes I WE-M-11.11 M70782-1 EPA 524.2 REV 4.1 13-FEB-08 17:55 RT V524STD Page I of 1 ® 12 of 20 New England a ii t�r 3. Section 5 GC/ MS Volatiles QC Data Summaries Includes the following where applicable: • Method Blank Summaries • Blank Spike Summaries • Matrix Spike and Duplicate Summaries • Surrogate Recovery Summaries ® 13 of 20 Method Blank Summary Page 1 of 2 Job Number: M70782 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-MB K23054.D 1 02/13/08 RT n/a n/a MSK820 cn 3 The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70782-1 CAS No. Compound Result RL Units Q 71-43-2 Benzene NO 0.50 ug/1 108-86-1 Bromobenzene ND 0.50 ug/l 74-97-5 Bromochloromethane -ND 0.50 ug/1 75-27-4 Bromodichloromethane ND 0.50 ug/l 75-25-2 Bromoform ND -` 0.50 ug/l 74-83-9 Bromomethane ND 0.50 ug/l 104-51-8 n-Butylbenzene NO 0.50 ug/l 135-98-8 sec-Butylbenzene .ND 0.50 ug/l 98-06-6 tert-Butylbenzene .ND 0.50 ug/l 108-90-7 Chlorobenzene ND . 0.50 ug/l 75-00-3 Chloroethane ND 0.50 ug/1 67-66-3 Chloroform ND 0.50 ug/l 74-87-3 Chloromethane ND 0.50 ug/l 95-49-8 o-Chlorotoluene ND 0.50 ug/l 166-43-4 p-Chlorotoluene ND 0.50 ug/l 56-23-5 Carbon tetrachloride ND 0.50 ug/1 75-34-3 1,1-Dichloroethane NO 0.50 ug/l 75-35-4 1i1-Dichloroethylene ND 0.50 ug/l 563-58-6 1,1-Dichloropropene 'ND 0.50 ug/1 96-12-8 1,2-Dibromo-3-chloropropane ND 0.50 ug/l 106-93-4 1,2-Dibromoethane ND 0.50 ug/1 107-06-2 1,2-Dichloroethane NO 0.50 ug/l 78-87-5 1,2-Dichloropropane ND 0.50 ug/l 142-28-9 1,3-Dichloropropane ND 0.50 ug/l 594-20-7 2,2-Dichloropropane NO 0.50 ug/l 124-48-1 Dibromochloromethane NO 0.50 ug/l 74-95-3 Dibromomethane ND 0.50 ug/l 75-71-8 Dichlorodifluoromethane ND 0.50 ug/l 10061-01-5 cis-1,3-Dichloropropene NO 0.50 ug/1 541-73-1 m-Dichlorobenzene ND 0.50 ug/l 95-50-1 o-Dichlorobenzene ND' 0.50 ug/l 106-46-7 p-Dichlorobenzene NO 0.50 ug/l 156-60-5 trans-1,2-Dichloroethylene ND 0.50 ug/l 156-59-2 cis-1,2-Dichloroethylene NO 0.50 ug/l 10061-02-6 trans-1,3-Dichloropropene NO 0.50 ug/l 100-41-4 Ethylbenzene ND 0.50 ug/1 ® 14 of 20 In Ar v--iJ'TEQ2 Method Blank Summary Page 2 of 2 Job Number: M70782 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-MB K23054.D 1 02/13/08 RT n/a n/a MSK820 to 1 The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70782-1 CAS No. Compound Result RL Units Q 87-68-3 Hexachlorobutadiene ND 0.50 ug/I 98-82-8 Isopropylbenzene ND 0.50 ug/l 99-87-6 p-Isopropyltoluene ND 0.50 ug/l 75-09-2 Methylene chloride ND 0.50 ug/I 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/I 91-20-3 Naphthalene ND 0.50 ug/I 103-65-1 n-Propylbenzene ND 0.50 ug/I 100-42-5 Styrene NII 0.50 ug/l 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/l 71-55-6 1,1,1-Trichloroethane ND 0.50 ug/I 79-34-5 1,1,2,2-Tetrachloroethane ND 0.50 ug/l 79-00-5 1,1,2-Trichloroethane ND 0.50 ug/I 87-61-6 1,2,3-Trichlorobenzene ND 0.50 ug/l 96-18-4 1,2,3-Trichloropropane ND 0.50 ug/I 120-82-1 1,2,4-Trichlorobenzene ND 0.50 ug/I 95-63-6 1,2,4-Trimethylbenzene ND 0.50 ug/l 108-67-8 1,3,5-Trimethylbenzene NO. 0.50 ug/I 127-18-4 Tetrachloroethylene ND 0.50 ug/l 108-88-3 Toluene ND 0.50 ug/l 79-01-6 Trichloroethylene 'ND 0.50 ug/l 75-69-4 Trichlorofluoromethane ND,: 0.50 ug/I 75-01-4 Vinyl chloride ND 0.50 ug/l m,p-Xylene ND 0.50 ug/l 95-47-6 o-Xylene ND 0.50 ug/l 1330-20-7 Xylenes(total) ND 0.50 ug/l CAS No. Surrogate Recoveries Limits 2199-69-1 1,2-Dichlorobenzene-d4 79% 70-130% 460-00-4 4-Bromofluorobenzene 92% 70-130% ® 15 of 20 Blank Spike Summary Page I of 2 Job Number: M70782 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-BS K23052.D 1 02/13/08 RT n/a n/a MSK820 ca iv The C reported here applies to the following samples: Method: EPA 524.2 REV 4.1 Q P PP g P M70782-1 Spike BSP BSP CAS No. Compound ug/l ug/l % Limits 71-43-2 Benzene 5 4.7 94 70-130 108-86-1 Bromobenzene 5 4.9 98 70-130 74-97-5 Bromochloromethane 5 4.9 98. -_ .-I 70-130 75-27-4 Bromodichloromethane 5 4.9 98= =:`: 70-130 75-25-2 Bromoform 5 4.9 98 70-130 74-83-9 Bromomethane 5 5.0 100 :' 70-130 104-51-8 n-Butylbenzene 5 4.9 98 70-130 135-98-8 sec-Butylbenzene 5 4.9 98 70-130 98-06-6 tert-Butylbenzene 5 4.9 98 , 70-130 108-90-7 Chlorobenzene 5 4.8 ,96: ;;: _; 70-130 75-00-3 Chloroethane 5 4.8 96 70-130 67-66-3 Chloroform 5 4.9 98, . ' 70-130 74-87-3 Chloromethane 5 5.0 .100 70-130 95-49-8 o-Chlorotoluene 5 4.8 96 ---= 70-130 106-43-4 p-Chlorotoluene 5 4.9 98 70-130 56-23-5 Carbon tetrachloride 5 4.9 98 70-130 75-34-3 1,1-Dichloroethane 5 5.0 100 70-130 75-35-4 1,1-Dichloroethyl ene 5 5.2 I04 70-130 563-58-6 1,1-Dichloropropene 5 4.8 _96 70-130 96-12-8 1,2-Dibromo-3-chloropropane 5 5.2 104 70-130 106-93-4 1,2-Dibromoethane 5 4.9 98-_ ;;' 70-130 107-06-2 1,2-Dichloroethane 5 5.0 100 70-130 78-87-5 1,2-Dichloropropane 5 4.8 96 70-130 142-28-9 1,3-Dichloropropane 5 4.5 90 70-130 594-20-7 2,2-Dichloropropane 5 4.6 92 70-130 124-48-1 Dibromochloromethane 5 4.9 98 70-130 74-95-3 Dibromomethane 5 5.1 102''- 70-130 75-71-8 Dichlorodifl uoromethane 5 3.6 72 70-130 10061-01-5 cis-1,3-Dichloropropene 5 4.8 96 70-130 541-73-1 m-Dichlorobenzene 5 4.9 98; 70-130 95-50-1 o-Dichlorobenzene 5 5.1 102 70-130 106-46-7 p-Dichlorobenzene 5 5.2 104 70-130 156-60-5 trans-1,2-Dichloroethylene 5 4.6 92 70-130 156-59-2 cis-1,2-Dichloroethylene 5 4.5 90 70-130 10061-02-6 trans-1,3-Dichloropropene 5 5.2 104 70-130 100-41-4 Ethylbenzene 5 4.8 96. 70-130 ® 16 of 20 Blank Spike Summary Page 2 of 2 Job Number: M70782 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-BS K23052.13 1 02/13/08 RT n/a n/a MSK820 iu The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70782-1 Spike BSP BSP CAS No. Compound ug/l ug/1 % Limits 87-68-3 Hexachlorobutadiene 5 5.4 108 70-130 98-82-8 Isopropylbenzene 5 4.9 98 70-130 99-87-6 p-Isopropyltoluene 5 5.0 100 70-130 75-09-2 Methylene chloride 5 4.6 .92 70-130 1634-04-4 Methyl Tert Butyl Ether 5 5.1 _102:;. 70-130 91-20-3 Naphthalene 5 5.5 110- 70-130 103-65-1 n-Propylbenzene 5 4.9 98_.._ 70-130 100-42-5 Styrene 5 4.7 94_.,,. 70-130 630-20-6 1,1,1,2-Tetrachloroethane 5 4.8 96 70-130 71-55-6 1,1,1-Trichloroethane 5 4.7 94 70-130 79-34-5 1,1,2,2-Tetrachloroethan e 5 5.1 102 70-130 79-00-5 1,1,2-Trichloroethane 5 4.9 98 70-130 87-61-6 1,2,3-Trichlorobenzene 5 6.6 132* . 70-130 96-18-4 1,2,3-Trichloropropane 5 4.7 94 70-130 120-82-1 1,2,4-Trichlorobenzene 5 5.2 104 70-130 95-63-6 1,2,4-Trimethylbenzene 5 4.8 96 70-130 108-67-8 1,3,5-Trimethylbenzene 5 4.9 98 70-130 127-18-4 Tetrachloroethylene 5 4.9 98 70-130 108-88-3 Toluene 5 4.8 96 70-130 79-01-6 Trichloroethylene 5 4.6 92 70-130 75-69-4 Trichlorofluoromethane 5 4.8 `96 70-130 75-01-4 Vinyl chloride 5 4.7 94 , 70-130 m,p-Xylene 10 9.5 95 70-130 95-47-6 o-Xylene 5 4.9 9$ 70-130 1330-20-7 Xylenes(total) 15 14.4 96 70-130 CAS No. Surrogate Recoveries BSP Limits 2199-69-1 1,2-Dichlorobenzene-d4 107% 70-130% 460-00-4 4-Bromofluorobenzene 102% 70-130% (a)Outside control limits. Associated samples are non-detect for this compound. ® 17 of 20 03 mrr-e rr==-r Duplicate Summary Page I of 2 Job Number: M70782 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch M70778-1DUP K23066.13 1 02/13/08 RT n/a n/a MSK820 M70778-1 K23065.13 1 02/13/08 RT n/a n/a MSK820 to The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70782-1 M70778-1 DUP CAS No. Compound ug/l Q ug/l Q RPD Limits 71-43-2 Benzene ND ND nc 30 108-86-1 Bromobenzene ND ND Inc 30 74-97-5 Bromochloromethane ND ND nc 30 75-27-4 Bromodichloromethane ND ND nc 30 75-25-2 Bromoform ND ND nc 30 74-83-9 Bromomethane ND ND ne 30 104-51-8 n-Butylbenzene ND ND nc - 30 135-98-8 sec-Butylbenzene ND ND nc 30 98-06-6 tert-Butylbenzene ND ND m. 30 108-90-7 Chlorobenzene ND ND nc 30 75-00-3 Chloroethane ND ND nc 30 67-66-3 Chloroform ND ND nc 30 74-87-3 Chloromethane ND ND no 30 95-49-8 o-Chlorotoluene ND ND nc 30 106-43-4 p-Chlorotoluene ND ND nc 30 56-23-5 Carbon tetrachloride ND ND nc 30 75-34-3 1,1-Dichloroethane ND ND ne 30 75-35-4 1,1-Dichloroethylene ND ND nc 30 563-58-6 1,1-Dichloropropene ND ND nc 30 96-12-8 1,2-Dibromo-3-chloropropane ND ND ne 30 106-93-4 1,2-Dibromoethane ND ND nc 30 107-06-2 1,2-Dichloroethane ND ND ne 30 78-87-5 1,2-Dichloropropane 0.28 0.25 J 11 30 142-28-9 1,3-Dichloropropane ND ND nc 30 594-20-7 2,2-Dichloropropane ND ND nc 30 124-48-1 Dibromochloromethane ND ND ne 30 74-95-3 Dibromomethane ND ND ne 30 75-71-8 Di chi orodifluoromethane ND ND nc 30 10061-01-5 cis-1,3-Dichloropropene ND ND nc 30 541-73-1 m-Dichlorobenzene ND ND nc 30 95-50-1 o-Dichlorobenzene ND ND nc 30 106-46-7 p-Dichlorobenzene ND ND nc 30 156-60-5 trans-1,2-Dichloroethylene ND ND nc 30 156-59-2 cis-1,2-Dichloroethylene ND ND nc 30 10061-02-6 trans-1,3-Dichloropropene ND ND nc 30 100-41-4 Ethylbenzene ND ND nc 30 B 18 of 20 ra,K r•r.. .ra—man-- Duplicate Summary Page 2 of Job Number:_ M70782 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch M70778-1DUP K23066.13 1 02/13/08 RT n/a n/a MSK820 M70778-1 K23065.D 1 02/13/08 RT n/a n/a MSK820 w The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70782-1 M70778-1 DUP CAS No. Compound ug/l Q ug/l Q RPD Limits 87-68-3 Hexachlorobutadiene ND ND nc. 30 98-82-8 Isopropylbenzene ND ND nc- 30 99-87-6 p-Isopropyltoluene ND ND nc 30 75-09-2 Methylene chloride ND ND nc. 30 1634-04-4 Methyl Tert Butyl Ether ND ND nc 30 91-20-3 Naphthalene ND ND nc 30 103-65-1 n-Propylbenzene ND ND nc 30 100-42-5 Styrene ND ND nc 30 630-20-6 1,1,1,2-Tetrachloroethane ND ND nc 30 71-55-6 1,1,1-Trichloroethane ND ND nc 30 79-34-5 1,1,2,2-Tetrachloroethane ND ND nc 30 79-00-5 1,1,2-Trichl oroethane ND ND nc 30 87-61-6 1,2,3-Trichlorobenzene ND ND nc 30 96-18-4 1,2,3-Trichloropropane ND ND nc- 30 120-82-1 1,2,4-Trichlorobenzene ND ND nc 30 95-63-6 1,2,4-Trimethylbenzene ND ND nc 30 108-67-8 1,3,5-Trimethylbenzene ND ND nc 30 127-18-4 Tetrachloroethylene ND ND nc 30 108-88-3 Toluene ND ND nc 30 79-01-6 Trichloroethylene 1.2 1.2 0 30 75-69-4 Trichlorofluoromethane ND ND nc 30 75-01-4 Vinyl chloride ND ND nc 30 m,p-Xylene ND ND nc 30 95-47-6 o-Xylene ND ND nc 30 1330-20-7 Xylenes(total) ND ND nc 30 CAS No. Surrogate Recoveries DUP M70778-1 Limits 2199-69-1 1,2-Dichlorobenzene-d4 84% 78% 70-130% 460-00-4 4-Bromofluorobenzene 85% 86% 70-130% ® 19 of 20 13ncnt_esr=--c---r_ Volatile Surrogate Recovery Summary Page 1 of I Job Number: M70782 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Method: EPA 524.2 REV 4.1 Matrix: AQ Samples and QC shown here apply to the above method :A Lab Lab Sample ID File ID Sl S2 M70782-1 K23070.D 780 92.0 M70778-1DUP K23066.1) 84.0 85.0 MSK820-BS K23052.1) 107.0 102.0 MSK820-MB K23054.1) 79.0 92.0 Surrogate Recovery Compounds Limits Si = 1,2-Dichlorobenzene-d4 707130%0 S2= 4-Bromofluorobenzene 70-130%-: ® 20 of 20 e-Hardeopy 2.0 Arctonrated RiTport ® New England 02/18/08-- Technical Report for ExxonMobil GESCT:01-QQA 249 Oakland Rd., South Windsor CT PO#4509333735 WBS#08 Accutest Job Number: M70781 Sampling Date: 02/08/08 Report to: Groundwater & Environmental Services JMoss@gesonline.com ATTN:,John Moss Total number of pages in report: 20 Ira 4 � a 0 , L01 a I WI Test results contained within this data package meet the requirements /RezaZand of the National Environmental Laboratory Accreditation Conference Lab Director AND and/or state specific certification programs as applicable. Client Service contact: Kristen Blanchard 508-481-6200 Certifications:MA(M-MA136) CT(PH-0109) NH(250204) RI(00071) ME(MA136) FL(E87579) kYE R S NY(23346) NJ(MA926) NAVY USACE rr--T?--WT- I . This report shall not be reproduced,except in its entirety,without the written approval of Accutest Laboratories. Test results relate only to samples analyzed. New England • 495 Tech Center West • Building 1 • Marlborough,MA 01752 • tel:508-481-6200 • fax:508-481-7753 • http://www.accutest.com ® 1 of 20 ®ACGU'iESIT. M70781 ;. „, '.., ,- Sectiolls: Table of Contents -1 Section1: Sample Summary ................................................................................................... 3 Section2: Case Narrative/Conformance Summary .............................................................. 4 Section3: Sample Results ................................................................................................... .. 5 3.1: M70781-1: 291D OAKLAND RD ............................................................................... 6 Section 4: Misc. Forms O 4.1: Chain of Custody ........................................................................................................... 9 4.2: RCP Form ...... ............................................................................................................ 11 4.3: Sample Tracking Chronicle ........................................................................................... 12 Section s: GUMS Volatiles-QC Data Summaries .............................................................. 13 5.1: Method Blank Summary ................................................................................................ 14 5.2: Blank Spike Summary ................................................................................................... 16 5.3: Duplicate Summary ....................................................................................................... 18 5.4: Surrogate Recovery Summaries ..................................................................................... 20 ® 2 of 20 ®ACCLrMS_T. Accutest Laboratories Sample Summary ExxonMobil Job No: M70781 GESCT:01-QQA 249 Oakland Rd., South Windsor CT Project No: PO#4509333735 WBS#08 Sample Collected Matrix Client Number Date Time By Received Code Type Sample ID M707814 02/08/08 13:35 KGA 02/11/08 DW Drinking Water 291D OAKLAND RD ® 3 of 20 ®/lGCU 'EST M70787 12ALCCUTEsm, L a b o r a t o r i e s SAMPLE DELIVERY GROUP CASE NARRATIVE Client: ExxonMobil Job No M70781 Site: GESCT:01-QQA 249 Oakland Rd.,South Windsor CT Report Date 2/18/2008 10:43:00 AM 1 Sample was collected on 02/08/2008 and were received at Accutest on 02/11/2008 properly preserved,at 0.9 Deg.C and intact. These Samples received an Accutest job number of M70781.A listing of the Laboratory Sample ID,Client Sample ID and dates of collection are presented in the Results Summary Section of this report. Except as noted below,all method specified calibrations and quality control performance criteria were met for this job.For more information,please refer to QC summary pages. Volatiles by GCMS By Method EPA 524.2 REV 4.1 Matrix AQ Batch ID: MSK820 All samples were analyzed within the recommended method holding time. . All method blanks for this batch meet method specific criteria. Sample(s) M70778-1DUP were used as the QC samples indicated. M MSK820-BS for 1,2,3-Trichlorobenzene:Outside control limits.Associated samples are non-detect for this compound. The Accutest Laboratories of New England certifies that all analysis were performed within method specification.It is further recommended that this report to be used in its eutirety.The Accutest Laboratories of NE,Laboratory Director or assignee as verified by the signature on the cover page has authorized the release of this report(M70781). Monday,February 18,2008 Page I of 1 ® 4 of 20 ®A ST.. M70781 - i.,'. ® New England 12ACC4JTEST .. Section 3 Sample Results Report of Analysis ® 5 of 20 ®ACCUTEST. M7n7A1 Accutest Laboratories Report of Analysis Page I of 2 ; Client Sample ID: 291D OAKLAND RD Lab Sample 1D: M70781-1 Date Sampled: 02/08/08 Matrix: DW-Drinking Water Date Received: 02/11/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT File ID DF Analyzed By Prep Date Prep Batch Analytical Batch Run#1 K23069.1) 1 02/13/08 RT n/a n/a MSK820 Run#2 Purge Volume Run#1 5.0 ml Run#2 VOA List CAS No. Compound Result MCL RL Units Q 71-43-2 Benzene ND 5.0 0.50 ug/I 108-86-1 Bromobenzene ND 0.50 ug/I 74-97-5 Bromochloromethane ND 0.50 ug/I 75-27-4 Bromodichloromethane ND 0.50 ug/I 75-25-2 Bromoform ND 0.50 ug/I 74-83-9 Bromomethane ND 0.50 ug/I 104-51-8 n-Butylbenzene ND 0.50 ug/I 135-98-8 sec-Butyl benzene ND 0.50 ug/I 98-06-6 tert-Butylbenzene ND 0.50 ug/I 108-90-7 Chlorobenzene ND 100 0.50 ug/I 75-00-3 Chloroethane ND 0.50 ug/I 67-66-3 Chloroform ND 0.50 ug/I 74-87-3 Chloromethane ND 0.50 ug/I 95-49-8 o-Chlorotoluene ND 0.50 ug/I 106-43-4 p-Chlorotoluene ND 0.50 ug/I 56-23-5 Carbon tetrachloride NO 5.0 0.50 ug/I 75-34-3 1,1-Dichloroethane ND 0.50 ug/I 75-35-4 1,1-Dichloroethylene NI) 7.0 0.50 ug/I 563-58-6 1,1-Dichloropropene ND 0.50 ug/I 96-12-8 1,2-Dibromo-3-chloropropane ND 0.20 0.50 ug/I 106-93-4 1,2-Dibromoethane ND 0.050 0.50 ug/I 107-06-2 1,2-Dichloroethane ND 5.0 0.50 ug/I 78-87-5 1,2-Dichloropropane ND 5.0 0.50 ug/I 142-28-9 1,3-Dichloropropane ND 0.50 ug/I 594-20-7 2,2-Dichloropropane ND 0.50 ug/I 124-48-1 Dibromochloromethane ND 0.50 ug/I 74-95-3 Dibromomethane ND 0.50 ug/I 75-71-8 Dichlorodifluoromethane ND 0.50 ug/I 10061-01-5 cis-1,3-Dichloropropene ND 0.50 ug/I 541-73-1 m-Dichlorobenzene ND 0.50 ug/l 95-50-1 o-Dichlorobenzene ND 600 0.50 ug/I 106-46-7 p-Dichlorobenzene ND 75 0.50 ug/I ND= Not detected J= Indicates an estimated value MCL= Maximum Contamination Level (40 CFR 141) B= Indicates analyte found in associated method blank E= Indicates value exceeds calibration range N = Indicates presumptive evidence of a compound ® 6 of 20 ®ACCtJTEST Accutest Laboratories Report of Analysis Page 2 of 2 Client Sample ID: 291 D OAKLAND RD Lab Sample ID: M70781-1 Date Sampled: 02/08/08 Matrix: DW-Drinking Water Date Received: 02/11/08 Method: EPA 524.2 REV 4.1 Percent Solids: n/a Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT VOA List CAS No. Compound Result MCL RL Units Q 156-60-5 trans-1,2-Dichloroethylene ND 100 0.50 ug/1 156-59-2 cis-1,2-Dichloroethylene ND 70 0.50 ug/l 10061-02-6 trans-1,3-Dichloropropene ND. 0.50 ug/1 100-41-4 Ethylbenzene .ND 700 0.50 ug/I 87-68-3 Hexachlorobutadiene ND 0.50 ug/1 98-82-8 Isopropylbenzene ND 0.50 ug/l 99-87-6 p-Isopropyltoluene ND 0.50 ug/1 .75-09-2 Methylene chloride ND 5.0 0.50 ug/I 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/1 91-20-3 Naphthalene ND 0.50 ug/1 103-65-1 n-Propylbenzene ND 0.50 ug/I 100-42-5 Styrene ND 100 0.50 ug/1 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/I 71-55-6 1,1,1-Trichloroethane ND 200 0.50 ug/1 79-34-5 1,1,2,2-Tetrachloroethane ND 0.50 ug/1 79-00-5 1,1,2-Trichloroethane ND 5.0 0.50 ug/1 87-61-6 1,2,3-Trichlorobenzene ND 0.50 ug/l 96-18-4 1,2,3-Trichloropropane ND 0.50 ug/I 120-82-1 1,2,4-Trichlorobenzene ND 70 0.50 ug/1 95-63-6 1,2,4-Trimethylbenzene ND 0.50 ug/1 108-67-8 1,3,5-Trimethylbenzene ND 0.50 ug/1 127-18-4 Tetrachloroethylene ND 5.0 0.50 ug/1 108-88-3 Toluene ND 1000 0.50 ug/1 79-01-6 Trichloroethylene ND 5.0 0.50 ug/1 75-69-4 Trichlorofluoromethane ND 0.50 ug/l 75-01-4 Vinyl chloride ND 2.0 0.50 ug/I m,p-Xylene ND 0.50 ug/1 95-47-6 o-Xylene ND 0.50 ug/1 1330-20-7 Xylenes(total) ND 10000 0.50 ug/1 CAS No. Surrogate Recoveries Run#1 Run#2 Limits 2199-69-1 1,2-Dichlorobenzene-d4 80% 70-130% 460-00-4 4-Bromofluorobenzene 91% 70-130% ND= Not detected J= Indicates an estimated value MCL= Maximum Contamination Level (40 CFR 141) B= Indicates analyte found in associated method blank E= Indicates value exceeds calibration range N= Indicates presumptive evidence of a compound ® 7 of 20 ®ACCUTEST. Me] New England Section 4 - ------------- - t TN T14 iC,Hf415 T R:V Misc. Forms Custody Documents and Other Forms Includes the following where applicable: • Chain of Custody • RCP Form • Sample Tracking Chronicle ® 8 of 20 ®A=LITEBT En CHAIN OF:C U STOD Y IN ACC_ UTERST_ 495 raw came.west pl 1p I: Marlhunh MA 01712 La D n:al n,ins a 132.3_l_ .:1. '... AL.,mi S>i .. 202IN7 FAX.73b}29-1n79d4A11 ,..CIlent/RenodliF,Infonna8on - .. FaciM Inform lion ,"^:: "•-_-- '- _ -„-__ ,.J-._____._.—, __.,_._ .,... :'r_.. •_.%i�;i$:[�i"R .,. nnalptir.,d Iniormali_nn EXXONMOBIL CORPORATION-Regional Lob atory Pro ram Northeast Consmlants Company Nam 111*lNam.: Groundwater&Environmental Services,Inc.-WNE Mobil-S.Windsor 401-QOA Address 91res1 I 425 B Hayden Station Road 249 Oakland Road 1 City slate zip City .Stale i j Windsor Connecticut - 06095 - S.Windsor ProJscl ConlaaL' Exnall EaxonMabilConlacl: J Jon Moss ullil aJ;m Me Caruso - _ Samp E Nama r E—Mabll CDIAW Phone 0 PhanaN Pax Locaeon lDp wasp, - 800 220-0119 ext.3540 860 688-9278 01-00A AFEN roe 14,56q3B AccUlesl collection Semple N p Df Field ID/Point of Collection Dale Tim Sa 8 b Mabee Wiled 3 IT _•}I —_ i f i ?� -�I Turnaramd Tuna Data DEhverOhle NransaNai _ Qsm.lo Bualnaas Deya Append 9y:l DAM: �Cammorclal'A" �PUL L!' �soayausx �Commartial"B" �:�'NYA 'CSteporyA,. ;,;A GROUNDWATER CLASSIFICATION 9 Day RUSH NJ Red...tl ::O NY -Cai...... . , 2D.Y EMERGENCY NJ Full smie o '_i RCP STANDARDS ©2D.YEMERGENCY Other _ 'Poo 10ay EMERGENCY _.../ Other Commarcbl"A"=Rasmus Only r•,Pl Fare en T_/A data available VIA Leblink - S..Plcuslotl moat be documented below each time saxmY las Chan a %sessio cl nD i delivery. T. O w 1 Y`p M70781. Chain of Custody Page 1 of 2 ® 9 of 20 ®ACCUTEST, M70781 'a',^'1!1 lab reports missing RCP data Page 1 of 1 Kathy Revane From: Mark Warren Sent: Friday,February 15,2008 3:50 PM To: Kathy Revane Subject:FW:lab reports missing RCP data From:John Moss[mailto:JMoss@gesonline.com] Sent::Friday,,February 15,2008 3:22 PM To:Mark Warren Subject:lab reports missing RCP data Mark, Here is a list of lab reports recently received without RCP details: M70778 M70779 M70786 M70785 M70780 M70783 M70782 M70781 RCP analysis was requested in the comments section of each chain of custody. Please let me know if that data package can be included with each report. Thank you, John John D.Moss Project Hydrogeologist Groundwater and Environmental Services,Inc. y 425B Hayden Station Road +� Windsor,CT 06095 PH:800-220-6119 Ext.3540 C: FX:860-688-9278 ,.: jmoss@gesonline.com Confidentiality Notice:This transmission(including any attachments)may contain confidential information belonging to Groundwater&Environmental Services,Inc.and is intended only for the use of the party or entity to which it is addressed.If you are not the intended recipient,you are hereby notified that any disclosure,copying,distribution,retention or the taking of action in reliance on the contents of this transmission is strictly prohibited.If you have received this transmission in error,please 3 D Ct� immediately notify the sender and erase all information and attachments.Thank You. as � � 2i 15r2003 p 4'b Laboratory Analysis QA/QC Certification Form tV Laboratory Name: Accutest New England Client: ExxonMobil Q Project Location: GESCT:01-QQA 249 Oakland Rd.,South Project Number: PO#4509333735 WBS#08 Windsor CT Sampling Date(s): 2/8/2008 Laboratory Sample ID(s): M70781-1 For each analytical method referenced in this laboratory report package, were all specified QA/QC performance criteria followed(including the requirement to 1 explain any criteria falling outside of acceptable guidelines,as specified in the CT Yes No j DEP method-specific Reasonable Confidence Protocol documents)? Were all samples received by the laboratory in a condition consistent with 2 that described on the associated chain-of-custody document(s)? Yes No 3 Were samples received at an appropriate temperature(4°C t 2°)? Yes ' No 4 Were all QA/QC performance criteria specified in the CT DEP Reasonable Confidence Protocol documents achieved? Yes No 5 a)Were reporting limits specified or referenced on the chain-of-custody? Yes No b)Were these reporting limits met? Yes No For each analytical method referenced in this laboratory report package, 6 were results reported for all constituents identified in the method-specific Yes J No Ll analyte lists presented in the Reasonable Confidence Protocol documents? 7 Are project-specific matrix spikes and laboratory duplicates included in this data set? Yes No Note: For all questions to which the response was"No" (with the exception of question#7),additional information must be provided in an attached narrative. If the answer to question#1 is "No",the data package does not meet the requirements for"Reasonable Confidence". 1,the undersigned,attest under pains and penalties of perjury that,to the best of my knowledge and belief and based upon my personal inquiry of those responsible for providing the information contained in this analytical report,such information is accurate and complete. Authorized Signature: / Position: Lab Director Printed Name: Reza Tand Date: 2/18/2008 11 of 20 ®ACCt.O MST. M70781 . -.,^,, ;. Accutest Laboratories Internal Sample Tracking Chronicle P. ExxonMobil Job No: M70781 GESCT:01-QQA 249 Oakland Rd., South Windsor CT Project No: PO#4509333735 WBS#08 Sample Number Method Analyzed By Prepped By Test Codes M70781-1 EPA 524.2 REV 4.1 13-FEB-08 17:28 RT V524STD Page 1 of 1 ® 12 of 20 New England ®AC:CUTFST i s i,u r a i,•r a e s .. .-t Section 5 --- ----� � _--___..._. �..��s ��:� �to ��t�_��.��x�`����-- ------------ -•-------- GC/MS Volatiles QC Data Summaries Includes the following where applicable: • Method Blank Summaries • Blank Spike Summaries • Matrix Spike and Duplicate Summaries • Surrogate Recovery Summaries ® 13 of 20 M70701 . ,. .,1 .I. Method Blank Summary Page I of 2 Job Number: M70781 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-MB K23054.D 1 02/13/08 RT n/a n/a MSK820 cn tea, The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70781-1 CAS No. Compound Result RL Units Q 71-43-2 Benzene ND 0.50 ug/l 108-86-1 Bromobenzene ND-.:: 0.50 ug/l 74-97-5 Bromochloromethane ND 0.50 ug/1 75-27-4 Bromodichloromethane ND 0.50 ug/l 75-25-2 Bromoform ND 0.50 ug/l 74-83-9 Bromomethane ND 0.50 ug/l 104-51-8 n-Butylbenzene ND 0.50 ug/l 135-98-8 see-Butyl benzene ND 0.50 ug/l 98-06-6 tert-Butyl benzene ND 0.50 ug/l 108-90-7 Chlorobenzene ND 0.50 ug/I 75-00-3 Chloroethane ND 0.50 ug/l 67-66-3 Chloroform ND 0.50 ug/l 74-87-3 Chloromethane ND 0.50 ug/1 95-49-8 o-Chlorotoluene ND 0.50 ug/l 106-43-4 p-Chlorotoluene ND 0.50 ug/l 56-23-5 Carbon tetrachloride ND. ` 0.50 ug/l 75-34-3 1,1-Dichloroethane ND 0.50 ug/l 75-35-4 1,1-Dichloroethylene ND 0.50 ug/l 563-58-6 1,1-Dichloropropene ND 0.50 ug/1 96-12-8 1,2-Dibromo-3-chloropropane ND 0.50 ug/l 106-93-4 1,2-Dibromoethane ND 0.50 ug/l 107-06-2 1,2-Dichloroethane ND 0.50 ug/l 78-87-5 1,2-Dichloropropane ND 0.50 ug/l 142-28-9 1,3-Dichloropropane ND% 0.50 ug/l 594-20-7 2,2-Dichloropropane ND 0.50 ug/l 124-48-1 Dibromochloromethane ND 0.50 ug/l 74-95-3 Dibromomethane ND 0.50 ug/l 75-71-8 Dichlorodifluoromethane NE- 0.50 ug/l 10061-01-5 cis-1,3-Dichloropropene ND 0.50 ug/l 541-73-1 m-Dichlorobenzene ND 0.50 ug/l 95-50-1 o-Dichlorobenzene ND 0.50 ug/l 106-46-7 p-Dichlorobenzene ND 0.50 ug/l 156-60-5 trans-1,2-Dichloroethylene ND 0.50 ug/l 156-59-2 cis-1,2-Dichloroethylene ND 0.50 ug/l 10061-02-6 trans-1,3-Dichloropropene ND 0.50 ug/l 100-41-4 Ethylbenzene ND 0.50 ug/l ® 14 of 20 QACCUTEST M7n7nI ....,., .,�., :P. Method Blank Summary Page 2 of Job Number: M70781 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-MB K23054.D 1 02/13/08 RT n/a n/a MSK820 s The QC reported here applies to the following samples Method: EPA 524.2 REV 4.1 M70781-1 CAS No. Compound Result RL Units Q 87-68-3 Hexachlorobutadiene ND 0.50 ug/l 98-82-8 Isopropylbenzene ND 0.50 ug/l 99-87-6 p-Isopropyltoluene ND 0.50 ug/I 75-09-2 Methylene chloride ND 0.50 ug/I 1634-04-4 Methyl Tert Butyl Ether ND 0.50 ug/l 91-20-3 Naphthalene ND 0.50 ug/l 103-65-1 n-Propylbenzene ND 0.50 ug/l 100-42-5 Styrene NID 0.50 ug/l 630-20-6 1,1,1,2-Tetrachloroethane ND 0.50 ug/I 71-55-6 1,1,1-Trichloroethane ND 0.50 ug/l 79-34-5 1,1,2,2-Tetrachloroethane NEI 0.50 ug/l 79-00-5 1,1,2-Trichloroethane ND 0.50 ug/l 87-61-6 1,2,3-Trichlorobenzene ND 0.50 ug/l 96-18-4 1,2,3-Trichloropropane ND 0.50 ug/l 120-82-1 1,2,4-Trichlorobenzene ND 0.50 ug/l 95-63-6 1,2,4-Trimethylbenzene ND 0.50 ug/l 108-67-8 1,3,5-Trimethylbenzene ND 0.50 ug/l 127-18-4 Tetrachloroethylene ND 0.50 ug/l 108-88-3 Toluene ND 0.50 ug/l 79-01-6 Trichloroethylene ND 0.50 ug/l 75-69-4 Trichlorofluoromethane ND 0.50 ug/l 75-01-4 Vinyl chloride ND 0.50 ug/l m,p-Xylene ND 0.50 ug/l 95-47-6 o-Xylene ND 0.50 ug/l 1330-20-7 Xylenes(total) ND 0.50 ug/l CAS No. Surrogate Recoveries Limits 2199-69-1 1,2-Dichlorobenzene-d4 79% 70-130% 460-00-4 4-Bromofluorobenzene 92% 70-130% Ell 15of20 ®ACC T.UTEB_ M70781 . :,i o.:P. Blank Spike Summary Page I oft Job Number: M70781 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-BS K23052.1) 1 02/13/08 RT n/a n/a MSK820 trr iv The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70781-1 Spike BSP BSP CAS No. Compound ug/I ug/l % Limits 71-43-2 Benzene 5 4.7 94 70-130 108-86-1 Bromobenzene 5 4.9 98 70-130 74-97-5 Bromochloromethane 5 4.9 98 70-130 75-27-4 Bromodichloromethane 5 4.9 98 70-130 75-25-2 Bromoform 5 4.9 98 - 70-130 74-83-9 Bromomethane 5 5.0 100 70-130 104-51-8 n-Butylbenzene 5 4.9 98 70-130 135-98-8 sec-Butyl benzene 5 4.9 98 70-130 98-06-6 tert-Butylbenzene 5 4.9 98 70-130 108-90-7 Chlorobenzene 5 4.8 96 70-130 75-00-3 Chloroethane 5 4.8 96 70-130 67-66-3 Chloroform 5 4.9 98 70-130 74-87-3 Chloromethane 5 5.0 100 70-130 95-49-8 o-Chlorotoluene 5 4.8 96 70-130 106-43-4 p-Chlorotoluene 5 4.9 98 70-130 56-23-5 Carbon tetrachloride 5 4.9 98 70-130 75-34-3 1,1-Dichloroethane 5 5.0 100 70-130 75-35-4 1,1-Dichloroethylene 5 5.2 104 70-130 563-58-6 1,1-Dichloropropene 5 4.8 96 70-130 96-12-8 1,2-Dibromo-3-chloropropane 5 5.2 104 70-130 106-93-4 1,2-Dibromoethane 5 4.9 98 70-130 107-06-2 1,2-Dichloroethane 5 5.0 100 70-130 78-87-5 1,2-Dichloropropane 5 4.8 96 70-130 142-28-9 1,3-Dichloropropane 5 4.5 90 70-130 594-20-7 2,2-Dichloropropane 5 4.6 92 70-130 124-48-1 Dibromochloromethane 5 4.9 98 70-130 74-95-3 Dibromomethane 5 5.1 102 70-130 75-71-8 Dichlorodifluoromethane 5 3.6 72 70-130 10061-01-5 cis-1,3-Dichloropropene 5 4.8 96 70-130 541-73-1 m-Dichlorobenzene 5 4.9 98 70-130 95-50-1 o-Dichlorobenzene 5 5.1 102 70-130 106-46-7 p-Dichlorobenzene 5 5.2 104 70-130 156-60-5 trans-1,2-Dichloroethylene 5 4.6 92 70-130 156-59-2 cis-1,2-Dichloroethylene 5 4.5 90 70-130 10061-02-6 trans-1,3-Dichloropropene 5 5.2 104 70-130 100-41-4 Ethylbenzene 5 4.8 96 70-130 ® 16 of 20 CIAC:C MST... MMR1 :.1:,::„s Blank Spike Summary Page 2 of Job Number: M70781 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch MSK820-BS K23052.D 1 02/13/08 RT n/a n/a MSK820 N The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70781-1 Spike BSP BSP CAS No. Compound ug/l ug/l % Limits 87-68-3 Hexachlorobutadiene 5 5.4 108 70-130 98-82-8 Isopropylbenzene 5 4.9 98 70-130 99-87-6 p-Isopropyltoluene 5 5.0 100 70-130 75-09-2 Methylene chloride 5 4.6 92 70-130 1634-04-4 Methyl Tert Butyl Ether 5 5.1 102 70-130 91-20-3 Naphthalene 5 5.5 110 70-130 103-65-1 n-Propylbenzene 5 4.9 98 70-130 100-42-5 Styrene 5 4.7 94 70-130 630-20-6 1,1,1,2-Tetrachloroethane 5 4.8 96 70-130 71-55-6 1,1,1-Trichloroethane 5 4.7 94 70-130 79-34-5 1,1,2,2-Tetrachloroethane 5 5.1 102 70-130 79-00-5 1,1,2-Trichloroethane 5 4.9 98 70-130 87-61-6 1,2,3-Trichlorobenzene 5 6.6 132*a 70-130 96-18-4 1,2,3-Trichloropropane 5 4.7 94 70-130 120-82-1 1,2,4-Trichlorobenzene 5 5.2 104 70-130 95-63-6 1,2,4-Trimethylbenzene 5 4.8 96 70-130 108-67-8 1,3,5-Trimethylbenzene 5 4.9 98 70-130 127-18-4 Tetrachloroethylene 5 4.9 98 70-130 108-88-3 Toluene 5 4.8 96 70-130 79-01-6 Trichloroethylene 5 4.6 .9.2 70-130 75-69-4 Trichlorofluoromethane 5 4.8 96 70-130 75-01-4 Vinyl chloride 5 4.7 94 70-130 m,p-Xylene 10 9.5 95 70-130 95-47-6 o-Xylene 5 4.9 98 70-130 1330-20-7 Xylenes(total) 15 14.4 96 70-130 CAS No. Surrogate Recoveries BSP Limits 2199-69-1 1,2-Dichlorobenzene-d4 107% 70-130% 460-00-4 4-Bromofl uorobenzene 102% 70-130% (a)Outside control limits. Associated samples are non-detect for this compound. ® 17 of 20 12ACCUTF—ST M70781 5 Duplicate Summary Page I of 2 Job Number: M70781 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch M70778-1 DUP K23066.D 1 02/13/08 RT n/a n/a MSK820 M70778-1 K23065.D 1 02/13/08 RT n/a n/a MSK820 w The C reported here applies to the following samples: Method: EPA 524.2 REV 4.1 Q P PP g p M70781-1 M70778-1 DUP CAS No. Compound ug/l Q ug/l Q RPD Limits 71-43-2 Benzene ND ND nc 30 108-86-1 Bromobenzene ND ND nc 30 74-97-5 Bromochloromethane ND ND nc 30 75-27-4 Bromodichloromethane ND ND nc: 30 75-25-2 Bromoform ND ND he 30 74-83-9 Bromomethane ND ND nc 30 104-51-8 n-Butylbenzene ND ND nc" 30 135-98-8 sec-Butyl benzene ND ND ne;: 30 98-06-6 tert-Butylbenzene ND ND ne 30 108-90-7 Chlorobenzene ND ND nc 30 75-00-3 Chloroethane ND ND nc 30 67-66-3 Chloroform ND ND nc, 30 74-87-3 Chloromethane ND ND nc 30 95-49-8 o-Chlorotoluene ND ND nc 30 106-43-4 p-Chlorotoluene ND ND nc 30 56-23-5 Carbon tetrachloride ND ND nc 30 75-34-3 1,1-Dichloroethane ND ND nc 30 75-35-4 1,1-Dichloroethylene ND ND nc 30 563-58-6 1,1-Dichloropropene ND ND nc 30 96-12-8 1,2-Dibromo-3-chloropropane ND ND nc 30 106-93-4 1,2-Dibromoethane ND ND nc 30 107-06-2 1,2-Dichloroethane ND ND ne 30 78-87-5 1,2-Dichloropropane 0.28 0.25 J 11 30 142-28-9 1,3-Dichloropropane ND ND nc 30 594-20-7 2,2-Dichloropropane ND ND nc 30 124-48-1 Dibromochloromethane ND ND nc 30 74-95-3 Dibromomethane ND ND nc 30 75-71-8 Dichlorodifluoromethane ND ND nc 30 10061-01-5 cis-1,3-Dichloropropene ND ND ne 30 541-73-1 m-Dichlorobenzene ND ND nc 30 95-50-1 o-Dichlorobenzene ND ND nc 30 106-46-7 p-Dichlorobenzene ND ND nc 30 156-60-5 trans-1,2-Dichloroethylene ND ND nc 30 156-59-2 cis-1,2-Dichloroethylene ND ND nc 30 10061-02-6 trans-1,3-Dichloropropene ND ND nc 30 100-41-4 Ethylbenzene ND ND nc 30 ® 18 of 20 ®ACCUT -ST. M70781 -- P Duplicate Summary Page 2 of 2 Job Number: M70781 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch M70778-1DUP K23066.1) 1 02/13/08 RT n/a n/a MSK820 M70778-1 K23065.13 1 02/13/08 RT n/a n/a MSK820 The QC reported here applies to the following samples: Method: EPA 524.2 REV 4.1 M70781-1 M70778-1 DUP CAS No. Compound ug/l Q ug/l Q RPD Limits 87-68-3 Hexachlorobutadiene ND ND no 30 98-82-8 Isopropylbenzene ND ND nc 30 99-87-6 p-Isopropyltoluene ND ND no 30 75-09-2 Methylene chloride ND ND no 30 1634-04-4 Methyl Tert Butyl Ether ND ND nc 30 91-20-3 Naphthalene ND ND no 30 103-65-1 n-Propylbenzene ND ND no 30 100-42-5 Styrene ND ND no 30 630-20-6 1,1,1,2-Tetrachloroethane ND ND nc 30 71-55-6 1,1,1-Trichloroethane ND ND no 30 79-34-5 1,1,2,2-Tetrachloroethane ND ND no 30 79-00-5 1,1,2-Trichloroethane ND ND no 30 87-61-6 1,2,3-Trichlorobenzene ND ND no 30 96-18-4 1,2,3-Trichloropropane ND ND no 30 120-82-1 1,2,4-Trichlorobenzene ND ND no 30 95-63-6 1,2,4-Trimethylbenzene ND ND no 30 108-67-8 1,3,5-Trimethylbenzene ND ND no 30 127-18-4 Tetrachloroethylene ND ND no 30 108-88-3 Toluene ND ND no 30 79-01-6 Trichloroethylene 1.2 1.2 .0 30 75-69-4 Trichlorofluoromethane ND ND no 30 75-01-4 Vinyl chloride ND ND no 30 m,p-Xylene ND ND no 30 95-47-6 o-Xylene ND ND no 30 1330-20-7 Xylenes(total) ND ND no 30 CAS No. Surrogate Recoveries DUP M70778-1 Limits 2199-69-1 1,2-Dichlorobenzene-d4 84% 78% 70-130% 460-00-4 4-Bromofluorobenzene 85% 86% 70-130% 19 of 20 ®ACCUTE!S_T. M707R1 Volatile Surrogate Recovery Summary Page I of i Job Number: M70781 Account: MOBILSS ExxonMobil Project: GESCT:01-QQA 249 Oakland Rd., South Windsor CT Method: EPA 524.2 REV 4.1 Matrix: AQ Samples and QC shown here apply to the above method :a. Lab Lab Sample ID File ID Sl S2 M70781-1 K23069.D 80.0 91.0 M70778-1DUP K23066.D 84.0 85.0 MSK820-BS K23052.D .107.0 102.0 MSK820-MB K23054.D 79..0 92.0 Surrogate Recovery Compounds Limits S1 = 1,2-Dichlorobenzene-d4 70-130% S2= 4-Bromofluorobenzene 70-130% ® 20 of 20 12ACCUTEST. M70M ',--- -1 t o e'