Loading...
HomeMy WebLinkAboutWell Inspection 160 Btrook Street Columbia Environmental Laboratory Drinking Water Analysis - Formaldehyde Testing STATE OF CONNECTICUT DEPARTMENT OF HEALTH National Property Inspection CERTIFICATION NUMBER 115 New London Turnpike PH-0314 Glastonbury, CT 06033 April 4, 1994 RE: Lab No. 940406, Inv. No. 94372 SAMPLING LOCATION: 160 Brook Street, South Windsor, Connecticut SAMPLING /DELIVERY TIMES: 1700 4/l/94 1245 4/2/94 Client Sampled STANDARD WATER ANALYSIS STATE OF CONNECTICUT TEST RESULTS RECOMMENDED/MAXIMUM LEVELS pH UNITS 6.7 6.5-9.0 RECOMMENDEDRANGE COLOR UNITS <5 15 RECOMMENDED MAXIMUM ODOR 0-5 3 RECOMMENDED 0 (none) MAXIMUM TURBIDITY NTU 5 RECOMMENDED 0.9 MAXIMUM ALKALINITY mg/L __ NO RECOMMENDED LEVEL CHLORIDE mg/L 31 250 MAXIMUM ALLOWABLE HARDNESS mg/L 6.0 0-60 soft, 61-120 mod. hard 121-180 hard, >181 v. hard AMMONIA AS N mg/L <.05 .050 RECOMMENDED MAXIMUM NITRITE AS N mg/L <.005 1.0 MAXIMUM /' ALLOWABLE NITRATE AS N mg/L 4.5 10.0 MAXIMUM ALLOWABLE DETERGENTS mg/L <0.5 0.5 MAXIMUM ALLOWABLF/�/ IRON mg/L 0 3 RECOMMENDED <0.10 MAXIMUM MANGANESE mg/L .050 RECOMMENDED MAXIMUM SODIUM mg/L 14 20 RECOMMENDED MAXIMUM COLIFORM BACTERIA 1/100 ml MAXIMUM 0/100 ml ALLOWABLE For the parameters analyzed, this is a satisfactory potable drinking water supply. If you have any questions, please feel free to call. Very truly yours, n C. Burrell 2 Lakeview Park West . Columbia, CT 06237 Telephone: (203) 228-0329