HomeMy WebLinkAboutWell Inspection 1287 Main Street (2) 368476832415A 6887249 P. 02
ENVIRCyTECR T_•ARORA-rORX
'T'IOMING & CONSULTING
77 COOK mjbL RoAn•WINnftoP, CONNUCTSC.UT 0099'
MARVGLLEN piLUZ10 TFLEPHONA
(103) a".7349
September 16, 1994
David Kosheta
188? Main St .
So. Windsor , Ct. 06074
Dear Sir ,
We have* the following to report on the sample submitted to this
laboratory on September 13, 1994.
Sample Number: 31515
Mark: water sample Collected 9/12/94 by Karen Kasheta From
Lot No. 1P87, Main St. , Sao. Windsor * Ct .
Odor none
Turbidity 73 Standard Units
phi 7.91
Alkalinity (a% CaCO3) 76 mg/L
Color ? 200 Standard Units
Ammonia Nitrogen 4 0.01 mg/L
Nitrite Nitrogen < 0.001 mg/L_.
Nitrate Nitrogen { 1 .00 mg/L
Chloride 8 mg/L
Hardness (as CaCCK ) 504 my/L.
Iron (as Fe) 0.72 mg/L
6ACT5RIOLIGICAL EXAMINATION
Number of Coliform Bacteria
per 100 mLs (membrane filter) 0
Based on the above parameters this water is classified safe for
drinking. The water is considered extremely hard since it
contains a hardness we11 over 100 mg/L. The turbidity, color ,
and iron contents are very high . If after regular use of this
well these parameters do not lower, treatment may be necessary.
If there are any questions we would be pleased to discuss them
with you.
Very truly yours,
EnviraTec./h`� Laboratory
Maryellen DiLuzia
c: So. Windsor Building Inspector , John Hogan or John Collins
PH 0464
SEP 16 194 09:40 6887249 PAGE.0102